    Dell Storage Center SCv2000 and SCv2020 Storage System Getting Started Guide Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001 ...

  • Dell SCv2000 - page 2

    Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. Copyright © 201 ...

  • Dell SCv2000 - page 3

    Before You Begin Consider the following best practices before setting up your SCv2000/SCv2020 storage system. • Dell recommends that you use a dedicated SAN network for data transmission when using a Fibre Channel or iSCSI storage system. • Complete the Worksheet to Record System Information in this guide before configuring the storage system. ...

  • Dell SCv2000 - page 4

    Class I laser products are not considered to be hazardous. The laser system and unit are designed so there is never any human access to laser radiation above a Class I level during normal operation, user maintenance or prescribed service condition. 4 ...

  • Dell SCv2000 - page 5

    Worksheet to Record System Information Use the following worksheet to record the information that is needed to install the SCv2000/SCv2020 storage system . Storage Center Information Gather and record the following information about the Storage Center network and the administrator user. Table 1. Storage Center Network Service Tag ________________ M ...

  • Dell SCv2000 - page 6

    IPv4 address for storage controller module 1: port 1 ___ . ___ . ___ . ___ IPv4 address for storage controller module 2: port 1 ___ . ___ . ___ . ___ (Four port I/O card only) IPv4 address for storage controller module 1: port 3 ___ . ___ . ___ . ___ (Four port I/O card only) IPv4 address for storage controller module 2: port 3 ___ . ___ . ___ . __ ...

  • Dell SCv2000 - page 7

    Table 6. Physical WWNs in Fault Domain 1 Physical WWN of storage controller 1: port 1 ________________ Physical WWN of storage controller 2: port 1 ________________ (Four port I/O card only) Physical WWN of storage controller 1: port 3 ________________ (Four port I/O card only) Physical WWN of storage controller 2: port 3 ________________ Table 7. ...

  • Dell SCv2000 - page 8

    • The Dell Storage Center Dell Storage Client Administrator’s Guide describes how to use the Dell Storage Client to manage a Storage Center. Installation and Configuration Before you begin installation, make sure that the site where you plan to install the storage system has standard power from an independent source or a rack power distribution ...

  • Dell SCv2000 - page 9

    Figure 2. Hole Locations in Rack 1. Middle hole of top 1U 2. Top hole of bottom 1U 3. Bottom hole of bottom 1U 6. Slide the storage system chassis onto the rails. Figure 3. Mount the SCv2000/SCv2020 Storage System Chassis 7. Secure the storage system chassis to the rack using the mounting screws within each chassis ear. a. Lift the latch on each ch ...

  • Dell SCv2000 - page 10

    Figure 4. Front Bezel 2. Insert the left end of the bezel into the securing slot until the release latch snaps into place. 3. Secure the bezel with the keylock. Front-End Cabling Front-end cabling refers to the connections between the storage system and host servers. Front ‐ end connections can be made using Fibre Channel, iSCSI, or SAS interface ...

  • Dell SCv2000 - page 11

    3. Connect fault domain 2 to switch 2. a. Connect a cable from storage controller 1: port 2 to switch 2. b. Connect a cable from storage controller 2: port 2 to switch 2. c. (Four-port I/O card only) Connect a cable from storage controller 1: port 4 to switch 2. d. (Four-port I/O card only) Connect a cable from storage controller 2: port 4 to switc ...

  • Dell SCv2000 - page 12

    a. Connect a SAS cable from storage controller 1: port 4 to server 4. b. Connect a SAS cable from storage controller 2: port 4 to server 4. Figure 6. Storage System Connected Directly to Host Servers 1. Server 1 2. Server 2 3. Server 3 4. Server 4 5. SCv2000/SCv2020 storage system 6. Storage controller 1 7. Storage controller 2 Cabling the Ethernet ...

  • Dell SCv2000 - page 13

    Figure 7. Storage System Connected to a Management Network 1. Management network switch 2. SCv2000/SCv2020 storage system 3. Storage controller 1 4. Storage controller 2 Back-End Cabling An SCv2000/SCv2020 storage system can be deployed with or without SC100/SC120 expansion enclosures . If the storage system is installed without expansion enclosure ...

  • Dell SCv2000 - page 14

    NOTE: In an SCv2000/SCv2020 storage system, the top storage controller is storage controller 1 and the bottom storage controller is storage controller 2. 1. If you are installing more than one expansion enclosure, cable the expansion enclosures in series by connecting a SAS cable from the top EMM, port B of one expansion enclosure to the top EMM, p ...

  • Dell SCv2000 - page 15

    Figure 10. Power Cables 3. Secure each power cable to the storage system chassis using the strain relief fasteners. 4. Plug the other end of the power cables into a grounded electrical outlet or a separate power source such as an uninterrupted power supply (UPS) or a power distribution unit (PDU). Turning on the Storage System Turn on the storage s ...

  • Dell SCv2000 - page 16

    NOTE: To discover and configure a Storage Center, the software must be installed on a host server that is located on the same subnet as the storage system 3. Start the software by double-clicking the Enterprise Manager Client shortcut. The Dell Storage Client welcome screen appears. • To discover and configure an uninitialized SCv2000/SCv2020 sto ...

  • Dell SCv2000 - page 17

    Storage Connectivity Configurations Storage Center supports up to 168 drives in one redundant-path SAS chain • An SCv2000 supports up to 13 SC100 expansion enclosures or 6 SC120 expansion enclosures • An SCv2020 supports up to 12 SC100 expansion enclosures or 6 SC120 expansion enclosures Redundant Array of Independent Disks (RAID) Controller Tw ...

  • Dell SCv2000 - page 18

    Power Supplies AC power supply (per power supply) Wattage 580 W (maximum wattage: 584 W) Voltage 100–240 VAC (7.6–3.0 A) Heat dissipation SCv2000 : 65 W at 230 VAC and 99 W at 115 VAC SCv2020 : 65 W at 230 VAC and 99 W at 115 VAC Maximum inrush current Under typical line conditions and over the entire system ambient operating range, the inrush ...

  • Dell SCv2000 - page 19

    Environmental Maximum vibration Operating 0.21 G at 5–500 Hz for 15 min Storage 1.04 G at 2–200 Hz for 15 min Maximum shock Operating Half-sine shock 5 G +/- 5% with a pulse duration of 10 ms +/- 10% (in operational orientations only) Storage Half-sine shock 30 G +/- 5% with a pulse duration of 10 ms +/- 10% (all sides) Altitude Operating 0 to ...

Manufacturer Dell Category Pet Fence

Documents that we receive from a manufacturer of a Dell SCv2000 can be divided into several groups. They are, among others:
- Dell technical drawings
- SCv2000 manuals
- Dell product data sheets
- information booklets
- or energy labels Dell SCv2000
All of them are important, but the most important information from the point of view of use of the device are in the user manual Dell SCv2000.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Dell SCv2000, service manual, brief instructions and user manuals Dell SCv2000. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Dell SCv2000.

Similar manuals

A complete manual for the device Dell SCv2000, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Dell SCv2000 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Dell SCv2000.

A complete Dell manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Dell SCv2000 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Dell SCv2000, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Dell SCv2000, that we can find in the current document
3. Tips how to use the basic functions of the device Dell SCv2000 - which should help us in our first steps of using Dell SCv2000
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Dell SCv2000
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Dell SCv2000 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Dell SCv2000?

Use the form below

If you did not solve your problem by using a manual Dell SCv2000, ask a question using the form below. If a user had a similar problem with Dell SCv2000 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)