    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 1 Not inten ded for mob il e ho me ins tall a tion. The Princess Insert By Blaz e King Model PI 1010A Ins ert Solid Fuel H eate r Residentia l Approved In Canada I n USA Valley Comfort Sy stems Blaze King In dustries 12 90 Commer c ia l W ay 146 A Str ee t Pen ti cto n, B C W a lla W al ...

  • Princess PI 1010A - page 2

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 2 A pproval Labe l PRINCES S INSERT LISTED S OLID FUE L BURN IN G FIREP LA CE INSER T MODE L : PI/1010 A T este d to: R e port No. 142-S-0 5-2 UL 1482 / ULC S628 CER T IFIED IN BO T H UNI TED STA T ES A ND CA N ADA EPA Ce rt . No . 586 PRE VEN T HOUSE F IRES- Instal l and use only in ac ...

  • Princess PI 1010A - page 3

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 3 Dear Custo m e r: Than k you for purchasing the Pr i ncess w ood burning in s ert (hereafter referred to as "stove"). This owner's m anual explains the steps requi red to sa fely assem ble , install, operate, and m a int ain your new stove. Be a responsible stove owner; ...

  • Princess PI 1010A - page 4

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 4 Safet y Notice IF THIS BLA Z E KING STOV E IS N OT PROPERLY INS T ALLED, A HOUSE FIRE MA Y RESU LT. TO REDUC E T H E RISK OF FIRE, FOLLOW THE INSTAL L A TION IN S T RUC T IONS. CON T A CT LOCA L BUI LDING OR FIRE OFF ICIA LS AB OU T RES T RIC T IONS A ND INSTA L LATION INSPEC TIO N RE ...

  • Princess PI 1010A - page 5

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 5 KEEP THI S MA NUAL FOR FU T U RE REFERENCE. Section _______________ _________ ________ ________ ________ ________ ________ ________ _________ ____ P age AP PROV AL LA BEL .................................................................................................................. ...

  • Princess PI 1010A - page 6

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 6 T able Of Content s As se mbly - Ge ne ral ...............................................................................................................................................18 - 20 Ins talla tio n into Fa c tory B u ilt F ire place s ...................................... ...

  • Princess PI 1010A - page 7

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 7 W arrant y BLAZE KIN G LI MITED WO ODST O VE W AR RAN TY - Pri nc ess Insert Blaze Kin g's war ranty policy only ap plies to units s old in the USA or CA N A DA WH AT TH E WA RR ANT Y COVER S : This war r anty con t ains dif fere nt terms wh i ch cove r diffe ren t parts o f the ...

  • Princess PI 1010A - page 8

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 8 Definitions BUILDIN G CODES A ND PERM ITS Mos t areas require a per mi t fro m the c ity or coun ty Building Inspe ctor, Fire Marsh al or Author i ty Having Juris dic- tion. Check l ocal bu ilding codes bef ore beg i nning i ns tallation. After t he i nsta ll a tion i s completed , i ...

  • Princess PI 1010A - page 9

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 9 Definitions COMBUS T ION A I R INTAK E Loca ted on the f ront ri gh t of t he sto v e. Combus t ion air i s draw n into t his ope ning, through the t her m ostat and into the firebo x. In tigh t conte mporary ho m es, us ing outs ide combustion a i r may be des irable. CREOSOTE - FOR ...

  • Princess PI 1010A - page 10

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 10 Definitions FLUE The gene ral term f or a pas sa ge through wh ich f lue ga s es (smoke) pass f ro m the combus t ion cha mber t o the outs ide air. FUEL T H IS ST OVE IS FOR US E WI TH SOL ID WO OD FUE L ONLY. Do not b urn tra sh, paper, pine branc hes or artific ial fire l ogs. S u ...

  • Princess PI 1010A - page 11

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 11 Safet y S A FET Y N OTICE IF T H IS STOV E IS N O T PROPERL Y I N STALLED , A HOUSE FIRE MAY RESU LT. FO R YOUR SAFE TY, FO L - LOW THE I NS TALLAT ION DIREC TIONS . C ONTACT LOCAL BUILD ING OR FI R E OFFICIAL S AB OUT R E- STRICTI ONS AND INSTALL ATION REQU IREMEN T S I N YOUR AREA ...

  • Princess PI 1010A - page 12

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 12 Safet y CHI LDREN Do not al low children to p lay nea r t he sto v e or w i th the contro ls. Severe burns m ay be inflicted by touching th e doo r or door glass , the f ront, sides or top of the sto v e. Train children to stay aw ay f rom the sto v e and nev er leave ch ildren unat ...

  • Princess PI 1010A - page 13

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 13 FU EL THIS W OOD STOVE I S FOR USE W ITH SOLID W O OD FUEL ONLY. NEVER USE GASOLINE, GAS O LIN E- TYPE LAN TERN F UEL, KER OSENE , CHARC OAL LIGHTER FLUID OR SIMILAR LIQUIDS TO STAR T O R 'FRESHEN UP' A FIRE IN T HI S HEA TER. KEEP ALL SUCH LIQ UIDS W ELL AWAY FROM THE HEAT ...

  • Princess PI 1010A - page 14

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 14 Specifications Specification PI 1010 A Min imum he a t o utpu t 6,2 00 Btu/hr Max imu m he at o utp ut 38 ,50 0 Btu/h r Overall e fficiency, w eighted average Me thod , 81 1/2% W ood capacity (appro xim ate) Whi te oa k 60 l bs . Fir 40 lbs . Recommende d w ood length 15 - 16 inches ...

  • Princess PI 1010A - page 15

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 15 WA R NING IMPROPER A SSEMBLY AN D/OR INSTAL LATION OF YOUR BLAZE KING WOODS TO VE OR FA ILURE T O OPERA TE IT ACC ORDING TO THE GUIDELINE S DE T AILED IN THESE INSTRUC TI ONS, W I LL VOID THE STOVE WA RR A NTY, CA N CA USE A HOUSE OR C HIMNEY FIRE, AN D MA Y ENDA NGER YOUR FAMILY. FO ...

  • Princess PI 1010A - page 16

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 16 Prep a ration And Assembl y Min imum Clearances T o Co mbustible s (Measure d from In sert/Stove Sides and Top) CO M B U S TIBL E 22 " (5 59 m m ) SH ROUD 13 1/4" 336 mm 12 1/2 " 317 mm Mantle C learance 7" (17 8 m m) 2 2 " (5 59 mm) 7" (17 8 m m) A A B ...

  • Princess PI 1010A - page 17

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 17 Princess PI1010A INSERT STOVE INSTAL L A TION P ROCEDU RE A FT ER YOU REA D A ND FULLY UNDER STAN D T HE MATERIA L IN T HIS MAN UA L , YO U AR E REA DY T O PROCEED W IT H THE I NS TALLA TI ON O F YOUR S TOVE. Before begi nning the installat i on, thor oughly clea n and inspec t the f ...

  • Princess PI 1010A - page 18

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 18 Assembl y I nstruc tions f or Princes s PI101 0A I nsert There will be local bui lding and f ire codes w hich could affect t his i ns tallat ion. Be sure you check w i th your l o cal building ins pector, fire i nsp ector or other local autho rities hav ing j ur isd iction in your ar ...

  • Princess PI 1010A - page 19

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 19 3) Ex ac t place m ent of the inse rt is de ter mined by the o v erall s hap e of your fireplace o pen ing and s urro und etc. First dete rmine w hether you w i ll need leve ling bo lts ins talled or othe r de vices to ens ure a pro per le vel ins tal- lation o f the unit. This is de ...

  • Princess PI 1010A - page 20

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 20 8) Slide the co mpleted un it into its fina l location. 9) Place the Con v ection de ck on the top o f the firebo x and fasten to the shro ud top us i ng the 2 scre ws pro vided (s ee F ig. 7). 10) Drop the catal ytic the r mometer in place on the top o f t he sto v e. The te mpera t ...

  • Princess PI 1010A - page 21

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 21 CHIMNEYS: FAC T ORY-BU ILT FIRE PL A CE In Canada a n d i n the U. S.A.: If the ins ert is ins talled into a factory bu i lt fire place the ch im ney mus t be l ined from the outlet o f the ins ert to the top of the ch imney w ith a S tainles s Steel li ner w hi ch me ets UL1777 or U ...

  • Princess PI 1010A - page 22

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 22 Operation Your sto v e’s perf ormance (including i ts efficiency, po l lutan t emiss i on l evel and se r vi ce lifet im e) dep end s l argel y on how i t is operated. You, then, are the m ost im porta nt f actor affect ing performance. Read these operation i n - structions care f ...

  • Princess PI 1010A - page 23

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 23 Operation YOUR FIRS T FIRE (continued) There are four co ntrol features to you r new Bl aze King t hat are instru m ental in ge tting you r firs t fire started . 1) The Thermos tat l ocated on the right front corner of the sto v e. Set the T her m ostat on “H igh”. After a bit yo ...

  • Princess PI 1010A - page 24

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 24 A couple of tips: Always hav e your ne xt intended l oad o f woo d ready whe n you open the Front Loading door. Doing so w ill d e- creas e the amoun t of time that the Front Load ing Door i s ope n, allow ing f or the Co m bus tor to re mai n quite hot and also pro v i de a m argin ...

  • Princess PI 1010A - page 25

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 25 Main tenance A SH REMOVA L Ash es m ay be re moved a t any time, but m us t be remo v ed whe n they appro ach t he level of the door openin g. DO NOT re m o ve all as hes f rom t he sto v e as a w oo d fire burn s best w hen m ade on a bed o f ashe s . The f reque ncy w ith which you ...

  • Princess PI 1010A - page 26

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 26 Main tenance GASK ET INSPEC TI ON Insp ect t he gas ket f or phys ical deterioration , missing sections or ob v ious l eaka ge. The sto v e f ront shou ld m a ke a groo v e in the gas ket m a terial - one side o f the groo ve (tow ard the i ns ide) wil l o ften be dark or b l ack, an ...

  • Princess PI 1010A - page 27

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 27 Main tenance CA T ALYTIC COMBUS TO R , REPLA CEMEN T The catalytic ther mometer on top o f the s to ve sho uld read i n the active zon e after t he sto v e has been i n operation f or se v era l hours . If the thermome ter's i ndicator nee dle does not stay abov e t he 1/3 m ark ...

  • Princess PI 1010A - page 28

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 28 Main tenance FAN A SSEMBLY Routine l ubr i cation of t he f an motor i s not required . Periodic c leaning of the f an ass em bly ( including fan blade s ) w ith a soft brus h and v acuum clean er w ill ensu re longer li f e and ma xim um e ff iciency for the f an as s embly. How - e ...

  • Princess PI 1010A - page 29

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 29 T roubleshooting Your Bl aze King i s des i gned to allow a wide selection of heat outpu t l e v els . If you begin t o l os e control of the amount o f heat the sto v e is emitting, deter mi ne the cau se ea rly so that ma jor prob l ems m ay be a voided. The s ix major need s o f a ...

  • Princess PI 1010A - page 30

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 30 T roubleshooting PROBLEM. Too much heat. CA USE SOLU TI ON By-Pas s door left open. C lose the by-pas s door. Ther mostat se t too h igh. Lo wer thermos tat s ett ing. Loa ding doo r gas ket leaking, Re place doo r gas ket admitting e xces s air i nto firebox and/or a djust do or, pa ...

  • Princess PI 1010A - page 31

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 31 T roubleshooting W ood t oo gree n or w et. Use seas one d wood. Combus tor plugge d or coated . Clean co mbustor, s ee pa ge 26 . Combus tor not f unc tioning. Check and test co m busto r If neede d rep lace co m bus tor. See pag e 27. Ther mostat not ope rat ing prope rly. Cons ult ...

  • Princess PI 1010A - page 32

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 32 St a ndard And Replacement Part s STAN DAR D & REPLA CEMENTS PA RTS Par t Nam e Part # Combus tor as s embly, Z4400 G Ther mometer, for sto v e top 034 2C Ther mostat knob 0102 W ood Handle - loading 0121A -byp as s doors 012 1B Fan rheo sta t knob 0137 Fan rh eo sta t 013 6 Fan ...

  • Princess PI 1010A - page 33

    DATE PR INTED: 2/ 8/05 Revision Date: 0 2/01/05 PI-1010 A Page 33 Notes: ...

Manufacturer Princess Category Outdoor Fireplace

Documents that we receive from a manufacturer of a Princess PI 1010A can be divided into several groups. They are, among others:
- Princess technical drawings
- PI 1010A manuals
- Princess product data sheets
- information booklets
- or energy labels Princess PI 1010A
All of them are important, but the most important information from the point of view of use of the device are in the user manual Princess PI 1010A.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Princess PI 1010A, service manual, brief instructions and user manuals Princess PI 1010A. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Princess PI 1010A.

A complete manual for the device Princess PI 1010A, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Princess PI 1010A by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Princess PI 1010A.

A complete Princess manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Princess PI 1010A - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Princess PI 1010A, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Princess PI 1010A, that we can find in the current document
3. Tips how to use the basic functions of the device Princess PI 1010A - which should help us in our first steps of using Princess PI 1010A
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Princess PI 1010A
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Princess PI 1010A in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Princess PI 1010A?

Use the form below

If you did not solve your problem by using a manual Princess PI 1010A, ask a question using the form below. If a user had a similar problem with Princess PI 1010A it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)