    Each Mobrey ultrasonic control system requires a sensor to suit the specific application, plus a control unit. These installation instructions cover the Mobrey control units in the MCU200 series. 1. Sensor installation 2. Control unit installation 3. Applications: 3. 1Gain adjustment 3. 2 Liquid level alarm 3. 3Pump control and latching arms 3. 4Bl ...

  • Emerson MCU200 - page 2

    1 . Sensor Installation When the gap is filled with liquid, the piezoelectric receiver crystal converts the ultrasonic wave into an electrical signal, which is transmitted back to the control unit using a second coaxial cable. Usually the two coaxial cables to the sensor are in one overall sheath. The control unit circuitry is a feedback amplifier ...

  • Emerson MCU200 - page 3

    T wo cables are required per sensor . The RG178 should be used where the cable itself is subject to temperatures exceeding 74°C. 2 . Control Unit Installation All cable connections are made to the terminal blocks along the bottom edge of the pcb (see fig.5). Release the terminal screw before inserting the wire. 2.2 External Connections Protection ...

  • Emerson MCU200 - page 4

    2.3 Switch Settings in MCU200 Series (i) Gain switch (and potentiometer): See section 3. (ii) Frequency selection This slide switch is labelled “FREQ” and is located between the sensor terminal block E2, and the Aux input terminals. This selects the operating frequency of the MCU200 oscillator , which is either 3.7MHz (switch in the 'up&ap ...

  • Emerson MCU200 - page 5

    3.1 Gain adjustment Correct adjustment of the gain (HI/LO switch and potentiometer) is essential for proper operation of any ultrasonic sensor system. This adjusts the gain of the feedback amplifier in the control unit, which produces oscillation of the sensor when the coupling between the ultrasonic crystals is sufficient. Therefore the higher the ...

  • Emerson MCU200 - page 6

    3.3 Pump control and latching alarms The output relay of the MCU200 can be latched into the de- energised state. This latch is achieved by short circuiting the two terminals of the Auxiliary input, labelled as terminals 3 & 4 on the pc board (see figure 5). The relay will remain de- energised while the latching short circuit is applied. Only af ...

  • Emerson MCU200 - page 7

    3.4 Interface Detection 3.4.1. Suspended Solids blanket sludge discharge detection The Mobrey MCU200 control unit can be used in conjunction with a 433S sensor to provide sludge blanket level detection in a settling tank, facilitating the control of automatic desludging. Similarly , in conjunction with a Mobrey sludge pipe using a pair of 488S sens ...

  • Emerson MCU200 - page 8

    3.4.3. Interface detection between two immiscible similar liquids When liquids are ultrasonically very similar - as happens for example with paraffin and water - the procedure in section 3.4.2. produces very little difference between the two “false dry” points. In this case the “reflection” method of interface detection is used. If an ultra ...

Manufacturer Emerson Category Projection Television

Documents that we receive from a manufacturer of a Emerson MCU200 can be divided into several groups. They are, among others:
- Emerson technical drawings
- MCU200 manuals
- Emerson product data sheets
- information booklets
- or energy labels Emerson MCU200
All of them are important, but the most important information from the point of view of use of the device are in the user manual Emerson MCU200.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Emerson MCU200, service manual, brief instructions and user manuals Emerson MCU200. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Emerson MCU200.

A complete manual for the device Emerson MCU200, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Emerson MCU200 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Emerson MCU200.

A complete Emerson manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Emerson MCU200 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Emerson MCU200, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Emerson MCU200, that we can find in the current document
3. Tips how to use the basic functions of the device Emerson MCU200 - which should help us in our first steps of using Emerson MCU200
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Emerson MCU200
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Emerson MCU200 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Emerson MCU200?

Use the form below

If you did not solve your problem by using a manual Emerson MCU200, ask a question using the form below. If a user had a similar problem with Emerson MCU200 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)