    INSTALLATION Heavy-Duty Spectra ® IV Series C3419M (8/06) In-Ceiling Back Box ...

  • Pelco c3419m - page 2

    2 C3419M (8/06) Installation BACK MOUNTING PLA TES  MOUNTING RING  CEILING  1 5 36 4 2 ...

  • Pelco c3419m - page 3

    C3419M (8/06) 3 1. Locate the center point of the mounting location and insert the compass tool. Draw a circle. 2. Cut the circle out of the ceiling. 3. Use the mounting ring as a template and mark the screw hole pattern onto the mounting surface. Prepare the holes. 4. Install the mounting plates. Use the eight 10-32 x 3-inch screws (supplied) and ...

  • Pelco c3419m - page 4

    4 C3419M (8/06) 7 8 VIDEO UTP+ UTP- RX- RX- TX- TX- PWR- PWR+ GND AUX2 GND GND NO NC COM 7 6 5 4 3 2 1 ALARMS AUX1 ...

  • Pelco c3419m - page 5

    C3419M (8/06) 5 7. Install the back box by compressing the spring clips and pushing the back box through the hole. T ighten the screws until you hear a clicking noise. 8. Connect wiring to the circuit board inside the back box. When finished, close the door to the back box and turn on the power . The green LED will light. NOTES: • Aux 1: Maximum ...

  • Pelco c3419m - page 6

    6 C3419M (8/06) TRIM LEASH  BALL STUD  BALL STUD RECEIVER  BARREL KEY LOCK  SWITCH 1 AND 2 11 9 10 ...

  • Pelco c3419m - page 7

    C3419M (8/06) 7 9. Configure DIP switches SW1 and SW2 located on the top of the dome drive. For DIP switch settings, refer to the labels located on the top of the dome drive or to the Switch Settings section of this manual. NOTE: When connecting more than one Spectra dome to a single controller , terminate the unit farthest from the controller . T ...

  • Pelco c3419m - page 8

    8 C3419M (8/06) Switch Settings WARNING: If you are using D-type or P-type control, your system may not operate if the baud rate and address switches are not set correctly . The switches are set at the factory at the defaults for D-type control (2400 baud and address 1). T able D. Switch Settings for SW2 Special Systems Switch Number 123456789 1 0 ...

  • Pelco c3419m - page 9

    C3419M (8/06) 9 T able E. Switch Settings for SW1, P-T ype Control NOTE: For Coaxitron controls, SW1 is not used; set all switches OFF . For D-type control systems, refer to T able F. T able F . Switch Settings for SW1, D-T ype Control NOTE: For Coaxitron controls, SW1 is not used; set all switches OFF . For P-type control systems, refer to T able ...

  • Pelco c3419m - page 10

    10 C3419M (8/06) SPECTRA ADDRESS SWITCH SETTING SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 71 ON ON ON OFF OFF OFF ON OFF 72 OFF OFF OFF ON OFF OFF ON OFF 73 ON OFF OFF ON OFF OFF ON OFF 74 OFF ON OFF ON OFF OFF ON OFF 75 ON ON OFF ON OFF OFF ON OFF 76 OFF OFF ON ON OFF OFF ON OFF 77 ON OFF ON ON OFF OFF ON OFF 78 OFF ON ON ON OFF OFF ON OFF 7 ...

  • Pelco c3419m - page 11

    C3419M (8/06) 11 SPECTRA ADDRESS SWITCH SETTING SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 151 ON ON ON OFF ON OFF OFF ON 152 OFF OFF OFF ON ON OFF OFF ON 153 ON OFF OFF ON ON OFF OFF ON 154 OFF ON OFF ON ON OFF OFF ON 155 ON ON OFF ON ON OFF OFF ON 156 OFF OFF ON ON ON OFF OFF ON 157 ON OFF ON ON ON OFF OFF ON 158 OFF ON ON ON ON OFF OFF ON 1 ...

  • Pelco c3419m - page 12

    12 C3419M (8/06) SPECTRA ADDRESS SWITCH SETTING SW1-1 SW1-2 SW1-3 SW1-4 SW1-5 SW1-6 SW1-7 SW1-8 223 ON ON ON ON ON OFF ON ON 224 OFF OFF OFF OFF OFF ON ON ON 225 ON OFF OFF OFF OFF ON ON ON 226 OFF ON OFF OFF OFF ON ON ON 227 ON ON OFF OFF OFF ON ON ON 228 OFF OFF ON OFF OFF ON ON ON 229 ON OFF ON OFF OFF ON ON ON 230 OFF ON ON OFF OFF ON ON ON 231 ...

  • Pelco c3419m - page 13

    C3419M (8/06) 13 Specifications GENERAL Construction Back Box Aluminum Dome Drive Aluminum, thermoplastic Lower Dome Clear polycarbonate, 0.090-inch thick Cage Thickness 0.12 x 0.30-inch cast stainless steel Cage Color Black, for maximum discreetness Cable Entry (Back Box) 0.75-inch conduit fitting Pan Movement 360° continuous pan rotation V ert ...

  • Pelco c3419m - page 14

    14 C3419M (8/06) The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002/95/EC This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and elect ...

  • Pelco c3419m - page 15

    PRODUCT WARRANTY AND RETURN INFORMA TION WARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below: • Five years on FR/FT/FS Series fiber optic products and TW3000 Series unshielded twisted ...

  • Pelco c3419m - page 16

    W orldwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .pelco.com ISO 9001 Australia | Canada | Finland | France | Italy | Russia | Singapore | Spain | Sweden | The Netherlands | United Arab Emirates | United Kingdom | Unit ...

Manufacturer Pelco Category Cable Box

Documents that we receive from a manufacturer of a Pelco c3419m can be divided into several groups. They are, among others:
- Pelco technical drawings
- c3419m manuals
- Pelco product data sheets
- information booklets
- or energy labels Pelco c3419m
All of them are important, but the most important information from the point of view of use of the device are in the user manual Pelco c3419m.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Pelco c3419m, service manual, brief instructions and user manuals Pelco c3419m. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Pelco c3419m.

Similar manuals

A complete manual for the device Pelco c3419m, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Pelco c3419m by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Pelco c3419m.

A complete Pelco manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Pelco c3419m - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Pelco c3419m, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Pelco c3419m, that we can find in the current document
3. Tips how to use the basic functions of the device Pelco c3419m - which should help us in our first steps of using Pelco c3419m
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Pelco c3419m
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Pelco c3419m in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Pelco c3419m?

Use the form below

If you did not solve your problem by using a manual Pelco c3419m, ask a question using the form below. If a user had a similar problem with Pelco c3419m it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)