    Service Manual A WG710 4 GS/s Arbitrary W aveform Generator 070-A830-51 This document applies to firmware version 3.0 and above. W arning The servicing instructions are for use by qualified personnel only . T o avoid personal injury , do not perform any servicing unless you are qualified to do so. Refer to all safety summaries prior to performing s ...

  • Tektronix 070-A830-51 - page 2

    Copyright  T ektronix Japan, Ltd. All rights reserved. Copyright  T ektronix, Inc. All rights reserved. T ektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material. Specifications and price change privileges reserved. T ektronix Japan, Lt ...

  • Tektronix 070-A830-51 - page 3

      T ektronix warrants that the products that it manufactures and sells will be free from defects in materials and workmanship for a period of one (1) year from the date of shipment. If a product proves defective during this warranty period, T ektronix, at its option, either will repair the defective product without charge fo ...

  • Tektronix 070-A830-51 - page 4

    ...

  • Tektronix 070-A830-51 - page 5

    A WG710 Service Manual i T able of Contents General Safety Summary xi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Service Safety Summary xiii . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Preface xv . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Tektronix 070-A830-51 - page 6

    T able of Contents ii A WG710 Service Manual T rigger Input T ests 4–37 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Event Input and Enhanced Mode T ests 4–41 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4 Clock Frequency and 10 MHz Reference Input T ests 4–48 . . . . . . ...

  • Tektronix 070-A830-51 - page 7

    T able of Contents A WG710 Service Manual iii Replaceable Mechanical Parts Parts Ordering Information 10–1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Using the Replaceable Parts List 10–2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Tektronix 070-A830-51 - page 8

    T able of Contents iv A WG710 Service Manual List of Figures Figure 1–1: Signal timing 1–10 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 1–2: Dimensions 1–15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 2–1: Rear panel power switch, fuse holder , and power connector 2 ...

  • Tektronix 070-A830-51 - page 9

    T able of Contents A WG710 Service Manual  Figure 4–1: Diagnostic menu 4–4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 4–2: Calibration r esult message box (except option 02) 4–6 . . . . . Figure 4–3: EVENT IN connector pins and signals and ground closur e connector 4–9 . . . . . . . . . . . . . . . . . . ...

  • Tektronix 070-A830-51 - page 10

    T able of Contents  A WG710 Service Manual Figure 6–1: Instrument orientation 6–1 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 6–2: External modules 6–12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 6–3: Internal modules (1) 6–13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Tektronix 070-A830-51 - page 11

    T able of Contents A WG710 Service Manual  Figure 10–3: Fr ont Output unit (except option 02) 10–9 . . . . . . . . . . . . . . . Figure 10–4: Fr ont Output unit (for option 02) 10–1 1 . . . . . . . . . . . . . . . . . . Figure 10–5: Chassis 10–13 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fi ...

  • Tektronix 070-A830-51 - page 12

    T able of Contents viii A WG710 Service Manual List of T ables T able 1–1: A WG710 waveform editors 1–1 . . . . . . . . . . . . . . . . . . . . . . . . . T able 1–2: Operation modes 1–4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T able 1–3: Arbitrary waveforms 1–4 . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Tektronix 070-A830-51 - page 13

    T able of Contents A WG710 Service Manual  T able 2–12: Confirmation selection for copy-all and move-all operations 2–38 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . T able 2–13: Setup screen parameter icons 2–41 . . . . . . . . . . . . . . . . . . . . . . T able 2–14: Setup bottom menu buttons 2–41 . . . . . ...

  • Tektronix 070-A830-51 - page 14

    T able of Contents  A WG710 Service Manual ...

  • Tektronix 070-A830-51 - page 15

    A WG710 Service Manual xi General Safety Summary Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. T o avoid potential hazards, use this product only as specified. Only qualified personnel should perform service pr ocedur es. Use Proper Power Cord. Use only the power cord spe ...

  • Tektronix 070-A830-51 - page 16

    General Safety Summary xii A WG710 Service Manual T erms in this Manual. These terms may appear in this manual:   W arning statements identify conditions or practices that could r esult in injury or loss of life.  Caution statements identify conditions or practices that could r esult in damage to this ...

  • Tektronix 070-A830-51 - page 17

    A WG710 Service Manual xiii Service Safety Summary Only qualified personnel should perform service procedures. Read this Service Safety Summary and the General Safety Summary before performing any service procedures. Do Not Service Alone. Do not perform internal service or adjustments of this product unless another person capable of rendering first ...

  • Tektronix 070-A830-51 - page 18

    Service Safety Summary  A WG710 Service Manual ...

  • Tektronix 070-A830-51 - page 19

    A WG710 Service Manual xv Preface The A WG710 Arbitrary W aveform Generator service manual provides informa- tion necessary for servicing the waveform generator to the module level. Manual Structure This manual is divided into main sections that address topics such as Specifica- tions and Theory of Operation . Further , some sections are divided in ...

  • Tektronix 070-A830-51 - page 20

    Preface xvi A WG710 Service Manual Manual Conventions Throughout this manual you will notice the use of certain conventions. Some sections of the manual contain procedures for you to perform. T o keep those instructions clear and consistent, this manual uses the following conventions:  Names of front panel controls and menus appear in the same c ...

  • Tektronix 070-A830-51 - page 21

    Preface A WG710 Service Manual xvii Contacting T ektronix Phone 1-800-833-9200 * Address T ektronix, Inc. Department or name (if known) 14200 SW Karl Braun Drive P .O. Box 500 Beaverton, OR 97077 USA Web site www .tektronix.com Sales support 1-800-833-9200, select option 1 * Service support 1-800-833-9200, select option 2 * T echnical support Email ...

  • Tektronix 070-A830-51 - page 22

    Preface  A WG710 Service Manual ...

  • Tektronix 070-A830-51 - page 23

    A WG710 Service Manual xix Introduction This manual provides information and procedures necessary for properly servicing the A WG710 Arbitrary W aveform Generator , as well as general information critical to safe and effective servicing. T o prevent personal injury or damage to the waveform generator, review the following information before attempt ...

  • Tektronix 070-A830-51 - page 24

    Introduction xx A WG710 Service Manual T ektronix Service Offerings T ektronix provides service to cover repair under warranty as well as other services that provide a cost-effective answer to your service needs. Whether providing warranty repair service or any of the other services listed below , T ektronix service technicians are well trained ser ...

  • Tektronix 070-A830-51 - page 25

    A WG710 Service Manual 1-1 Product Overview Product Description The A WG710 Arbitrary W aveform Generator is a waveform generator that can generate simple and arbitrary waveforms, one-channel differential output arbitrary waveforms, and function generator waveforms. The A WG710 Arbitrary W aveform Generator allows you to create sine, triangle, squa ...

  • Tektronix 070-A830-51 - page 26

    Product Overview 1-2 A WG710 Service Manual T able 1-1: A WG710 waveform editors (Cont.) Editor Description                   ? ...

  • Tektronix 070-A830-51 - page 27

    A WG710 Service Manual 1-3 Specifications This section contains the A WG710 Arbitrary W aveform Generator specifications. All specifications are guaranteed unless labeled T ypical . T ypical specifications are provided for your convenience. Specifications that are marked with the n symbol in the Characteristics column are defined in the Performance ...

  • Tektronix 070-A830-51 - page 28

    Specifications 1-4 A WG710 Service Manual Electrical Specification T able 1-2: Operation modes Characteristics Description Continuous Waveform is continuously output in this mode. When a sequence is defined, waveforms are sequentially or repeatedly output in the order defined by the sequence. The extended sequence functions, such as trigger input a ...

  • Tektronix 070-A830-51 - page 29

    Specifications A WG710 Service Manual 1-5 T able 1-4: Clock generator Characteristics Description PV reference page Sampling frequency 50 kHz to 4 GHz Resolution 8 digits Internal clock 1 n Frequency accuracy " 1 ppm (10 _ Ct o4 0 _ C) (50 _ F to 104 _ F) , for one year after calibration Page 4-48 Phase noise at 1/4 clock output, T ypical (Dat ...

  • Tektronix 070-A830-51 - page 30

    Specifications 1-6 A WG710 Service Manual T able 1-6: Main output (Cont.) Characteristics 3 PV reference page Description Resolution 1m V n Accuracy " 1.5% of offset " 10 mV , (20 mV amplitude, waveform data: 0) Page 4-22 Pulse response (W aveform data: -1 and 1, offset: 0 V , and filter: through) n Rise time (10% to 90%) x 480 ps (amplit ...

  • Tektronix 070-A830-51 - page 31

    Specifications A WG710 Service Manual 1-7 T able 1-7: Filter Characteristics Description T ype Bessel low pass filter , 200 MHz,100 MHz, 50 MHz, and 20 MHz Rise time (10% to 90%), T ypical 20 MHz 50 MHz 100 MHz 200 MHz 17 ns 7n s 3.7 ns 2n s Group delay , T ypical 20 MHz 50 MHz 100 MHz 200 MHz 18 ns 8n s 4.7 ns 3n s T able 1-8: Auxiliary outputs Ch ...

  • Tektronix 070-A830-51 - page 32

    Specifications 1-8 A WG710 Service Manual T able 1-8: Auxiliary outputs (Cont.) Characteristics PV reference page Description 10 MHz Reference clock out Amplitude, T ypical y 1.2 V pkĆpk ,i n t oa5 0 W load, Max 2.5 V pkĆpk , open circuit Impedance 50 W, AC coupling Connector Rear panel BNC connector 4 The characteristics are specified at the end ...

  • Tektronix 070-A830-51 - page 33

    Specifications A WG710 Service Manual 1-9 T able 1-1 1: Auxiliary inputs Characteristics Description PV reference page T rigger input 5 Connector Rear panel BNC connector Impedance 1k W or 50 W Polarity (Trigger mode)/Slope (Gated mode) POS (positive) or NEG (negative) Input voltage range " 1 0V ,i n t oa1k W load " 5V ,i n t oa5 0 W load ...

  • Tektronix 070-A830-51 - page 34

    Specifications 1-10 A WG710 Service Manual Marker output Analog output (Filter:ĂThrough) External T rigger (ĂMarker Skew : 70 psĂtypicalĂĂ) m0 m1 m2 m3 T rigger Holdoff (109.5 clocks + 500 ns) Delay to analog output (21 1.5 clocks + 17 ns) 1 Clock (ĂNormal output : 3Ăns typical, Ă Direct output : - 500ĂpsĂtypicalĂ option 02 : - 1..2ns ty ...

  • Tektronix 070-A830-51 - page 35

    Specifications A WG710 Service Manual 1-1 1 T able 1-12: Event Input Characteristics Description Connector 9Ćpin, D type on the rear panel Number of events 4 bits Input signal 4 event bits and Strobe Threshold TTL level Maximum input 0Vt o+5V( D C+ peak AC) Impedance 1k W , pullĆup to +3.3 V Enhanced mode Minimum pulse width 320 clocks + 10 ns Ev ...

  • Tektronix 070-A830-51 - page 36

    Specifications 1-12 A WG710 Service Manual T able 1-14: Function generatorĂ(FG) Characteristics Description Operation Mode Continuous mode only W aveform Shape Sine, T riangle, Square, Ramp, Pulse, DC Frequency 1.000 Hz to 400.0 MHz Amplitude Range 0.020 V pkĆpk to 2.000 V pkĆpk ,i n t oa5 0 W load Resolution 1m V Offset (except option 02) Range ...

  • Tektronix 070-A830-51 - page 37

    Specifications A WG710 Service Manual 1-13 T able 1-15: Display and timer Characteristics Description Display Display area Horizontal: 130.6 mm (5.14 in) V ertical: 97.0 mm (3.81 in) Resolution 640 (H)  480 (V) pixels Size 16 cm (6.4 in) diag. LCD T able 1-16: AC line power Characteristics Description Rating voltage 100 V AC to 240 V AC, CA T II ...

  • Tektronix 070-A830-51 - page 38

    Specifications 1-14 A WG710 Service Manual T able 1-19: Installation requirement Characteristics Description Heat dissipation Maximum power 220 V A (maximum line current: 3 A rms ,a t5 0H z ) Surge current 30 A (25 _ C) peak for equal to or less than 5 line cycles, after the instrument has been turned off for at least 30 seconds Cooling clearance T ...

  • Tektronix 070-A830-51 - page 39

    Specifications A WG710 Service Manual 1-15 T able 1-21: Mechanical Characteristics Description Net weight (without package) 14.1 kg (31.1 lb) Dimensions (without package) Height 177 mm (6.97 in) 193 mm (7.60 in) with Feet Width 424 mm (16.69 in) 433 mm (17.05 in) with Handle Length 470 mm (18.50 in) 508 mm (20.00 in) with Rear Feet Net weight (with ...

  • Tektronix 070-A830-51 - page 40

    Specifications 1-16 A WG710 Service Manual Certification and Compliances The certification and compliances for the A WG710 Arbitrary W aveform Generator are listed in T able 1–22. See T able 1–23 for installation categories and pollution degree descriptions. T able 1-22: Certifications and compliances Characteristics Description EC declaration ...

  • Tektronix 070-A830-51 - page 41

    Specifications A WG710 Service Manual 1-17 T able 1-23: Installation category and pollution degree descriptions Characteristics Description Installation category T erminals on this product may have different installation category designations. The installation categories are:   CA T III Di ...

  • Tektronix 070-A830-51 - page 42

    Specifications  A WG710 Service Manual ...

  • Tektronix 070-A830-51 - page 43

    A WG710 Service Manual 2-1 Preparation for Use This subsection provides the following information:  Supplying Operating Power  Operating Envir onment  Installation  Repackaging Instructions Supplying Operating Power   T o avoid equipment failur e and potential fir e or personal shock hazar ds, do not exceed the m ...

  • Tektronix 070-A830-51 - page 44

    Preparation for Use 2-2 A WG710 Service Manual T able 2-1: PowerĆcord conductor identification Conductor Color Alternate Color Ungrounded (Line) Brown Black Grounded (Neutral) Light Blue White Grounded (Earthing) Green/Y ellow Green T able 2-2: Power cord identification Plug configuration Normal usage Option number North America 125 V Standard Eur ...

  • Tektronix 070-A830-51 - page 45

    Preparation for Use A WG710 Service Manual 2-3 The A WG710 Arbitrary W aveform Generator operates with any line voltage from 90 to 250 V AC RMS with any line frequency from 48 to 63 Hz. There are two fuses, either of which may be used throughout the line voltage and frequency ranges. The two fuses are not interchangeable as each requires a differen ...

  • Tektronix 070-A830-51 - page 46

    Preparation for Use 2-4 A WG710 Service Manual Installation Before installation, refer to the Safety Summary section at the front of this manual for power source, grounding, and other safety information. V erify that you have the correct operating environment.  Damage to the instrument can occur if it is power ed on at tempe ...

  • Tektronix 070-A830-51 - page 47

    Preparation for Use A WG710 Service Manual 2-5  . If the air flow is r estricted and the internal temperatur e of the AWG710 Arbitrary W aveform Generator exceeds the pr oper operating temperatur e range, the instrument temporarily shuts down to pr otect the internal modules fr om overheating. T o pr event temporary shutdown of the AWG7 ...

  • Tektronix 070-A830-51 - page 48

    Preparation for Use  A WG710 Service Manual  . The second fuse listed in the table on page 2–5 is appr oved under the IEC standar ds. This fuse is used in equipment sold in the Eur opean market. ...

  • Tektronix 070-A830-51 - page 49

    Preparation for Use A WG710 Service Manual 2-7 Check that you have the proper electrical connections. The A WG710 Arbitrary W aveform Generator operates within the following power supply voltage and frequency ranges: Line voltage range 100 - 240 V Line frequency 4 8-6 3H z Maximum power 220 V A Connect the proper power cord from the rear panel powe ...

  • Tektronix 070-A830-51 - page 50

    Preparation for Use 2-8 A WG710 Service Manual T o power on the instrument, push the ON/STBY switch (shown in Figure 2–2) on the lower left side of the front panel. Check that the fan is blowing air out of the instrument.  . The instrument must be warmed up for at least 20 minutes and the clock calibrated to operate at its optimum acc ...

  • Tektronix 070-A830-51 - page 51

    Preparation for Use A WG710 Service Manual 2-9 The instrument automatically runs power-on self tests to check that the instru- ment is operating normally . Check the results of the power-on self tests. If all the diagnostic tests are completed without error , the instrument displays Pass and then the SETUP menu screen. If the system detects an erro ...

  • Tektronix 070-A830-51 - page 52

    Preparation for Use 2-10 A WG710 Service Manual Repackaging for Shipment Use the original packaging material to return the instrument. If the original packaging is unfit for use or is not available, repackage the instrument as follows: 1. Obtain a corrugated cardboard shipping carton with dimensions of at least three inches greater than the instrum ...

  • Tektronix 070-A830-51 - page 53

    Preparation for Use A WG710 Service Manual 2-1 1 Applying and Interrupting Power Refer to the following information when you power on or power off the instrument, or when power is interrupted due to an external power failure. Upon power on, the W aveform Generator runs a power-on self check. If it passes, the A WG710 Arbitrary W aveform Generator d ...

  • Tektronix 070-A830-51 - page 54

    Preparation for Use  A WG710 Service Manual ...

  • Tektronix 070-A830-51 - page 55

    A WG710 Service Manual 2-13 Operating Basics This section provides an overview of the following topics:  The Contr ols and Connectors subsection describes the instrument buttons, controls, connectors, and typical screen displays.  The Menu Operations subsection describes how to use menus and enter numeric and text values.  The Shortcut Con ...

  • Tektronix 070-A830-51 - page 56

    Operating Basics 2-14 A WG710 Service Manual  See Figure 2-5 See Figure 2-4 CLEAR MENU button Bottom and side bezel menu buttons The bottom buttons call up submenu, and the side buttons execute more detailed operations within the submenu. Cancels the current operation and closes the side and submenu. The display can be returned to the top lev ...

  • Tektronix 070-A830-51 - page 57

    Operating Basics A WG710 Service Manual 2-15  TOGGLE button SHIFT button When you push a numeric or unit button while the SHIFT LED is on, the function shown in blue above a key is executed. The SHIFT button toggles on and off. When the instrument displays the File Name Input dialog box, you can input upper case characters when the SHIFT LED ...

  • Tektronix 070-A830-51 - page 58

    Operating Basics 2-16 A WG710 Service Manual TRIGGER controls QUICK EDIT button RUN button VERTICAL controls HORIZONT AL controls Enters the QUICK EDIT mode from the waveform editor . This button allows you to edit waveforms that have immediate effect on the output signal. Use together with the VERTICAL and HORIZONT AL controls for quick edit. Used ...

  • Tektronix 070-A830-51 - page 59

    Operating Basics A WG710 Service Manual 2-17 Power supply fuse holder The 10 A fast blow an d5A( T ) fuse are used for 1 15 V and 230 V systems, respectively . Power connector Connect the provided power cable to this connector . 100/10BASEĆT connector IEEE STD 488 connector Connect to the Ethernet network. KEYBOARD connector DISPLA Y MONITOR OUT c ...

  • Tektronix 070-A830-51 - page 60

    Operating Basics 2-18 A WG710 Service Manual Menu Operations This section describes the A WG710 Arbitrary W aveform Generator menu system and numeric and text input methods. The A WG710 Arbitrary W aveform Generator uses menus to make selections. There are four menu buttons labeled EDIT , SETUP , APPL, and UTILITY shown in Figure 2–7. Pushing a m ...

  • Tektronix 070-A830-51 - page 61

    Operating Basics A WG710 Service Manual 2-19 Pushing a front panel menu button displays the screen and bottom menu items associated with the button. Y ou select a bottom menu item by pushing the button directly below that menu item. Pushing a bottom button displays a side menu, pop-up menu, list, or dialog box. Figure 2–8 through 2–1 1 show exa ...

  • Tektronix 070-A830-51 - page 62

    Operating Basics 2-20 A WG710 Service Manual Use a side menu button to display a side submenu, set a parameter , perform a task, or cancel an operation. T able 2–5 describes the side menu button types. T able 2-5: Side menu elements Menu items Description Menu items Description Executes the displayed funcĆ tion immediately . Cannot be used in th ...

  • Tektronix 070-A830-51 - page 63

    Operating Basics A WG710 Service Manual 2-21 fields. A 1-of-N field contains two or more choices. Only one choice can be selected at a time. Push the OK side button to confirm the dialog box. Push the Cancel side button or the CLEAR MENU button to exit the dialog box without making any changes.   ? ...

  • Tektronix 070-A830-51 - page 64

    Operating Basics 2-22 A WG710 Service Manual Use the use arrow buttons to move the cursor to a desired position. Use y and b arrow buttons to move the cursor up or down in a pop-up menu, make a selection in a dialog box, or move a cursor in the Editor menu. Use a and ' arrow buttons to make a selection in a dialog box, move the input caret whe ...

  • Tektronix 070-A830-51 - page 65

    Operating Basics A WG710 Service Manual 2-23 Numeric Keypad. Figure 2–13 shows the numeric keypad and descriptions of the button functions. The SHIFT button enters a character labeled in blue. Push the SHIFT button and then push the keypad button. The ENTER button enters the current value into the instrument. The DELETE button deletes the charact ...

  • Tektronix 070-A830-51 - page 66

    Operating Basics 2-24 A WG710 Service Manual enter the changes. For example, to enter 200.5 m s, push 2 , 0 , 0 , . , 5 ,  ( SHIFT + 4 ),and ENTER . When you enter a value larger than the maximum value in the parameter range, the parameter will be set to the maximum value. When you enter a value smaller than the minimum value, the minimum value ...

  • Tektronix 070-A830-51 - page 67

    Operating Basics A WG710 Service Manual 2-25                 Figure 2-14: Three type of Input text dialog boxes V erify that the chara ...

  • Tektronix 070-A830-51 - page 68

    Operating Basics 2-26 A WG710 Service Manual 4. Push DRIVE... (side) to change the drive. Use the general purpose knob or y and b arrow buttons to select the drive in the select drive dialog box and push OK (side). 5. Push Up Level (side) to move up a directory . Y ou cannot move up the directory if you are at the highest level directory . 6. Press ...

  • Tektronix 070-A830-51 - page 69

    Operating Basics A WG710 Service Manual 2-27 T able 2-6: T ext input button functions (cont.) Control Description CLR button Clears the entire text field. Numeric buttons Enters numeric characters into the text field. SHIFT button Enters a selected character in upper case. When you push the SHIFT button, the SHIFT LED lights. When the dialog box di ...

  • Tektronix 070-A830-51 - page 70

    Operating Basics 2-28 A WG710 Service Manual T able 2-7: Shortcut controls (cont.) Controls Description HORIZONT AL Displays the Horizontal side menu. This is the same as selecting SETUP (front)  Horizontal (bottom). Adjusts the clock setting. This is the same as selecting SETUP (front)  Horizontal (bottom)  Clock (side), and then turning ...

  • Tektronix 070-A830-51 - page 71

    Operating Basics A WG710 Service Manual 2-29 T able 2-8: A WG710 Arbitrary W aveform Generator file types (cont.) File type Description T ext file Uses the .txt or .TXT file suffix. Contains ASCII text. Created with the equation/text editor . And setting parameter file of APPL Digital Modulation. Setup file Uses the .set or .SET file suffix. Contai ...

  • Tektronix 070-A830-51 - page 72

    Operating Basics 2-30 A WG710 Service Manual  . In the following pr ocedur es, you may have to push the EDIT button twice to exit the editor . When the instrument does not display the file list, push the EDIT button again. If you ar e pr ompted, refer to Saving Files on page 2–33. Y ou can copy files in from a double window or a singl ...

  • Tektronix 070-A830-51 - page 73

    Operating Basics A WG710 Service Manual 2-31 T o move a file in the double window , do the following steps: 1. Push EDIT (front) button and select the file to copy . 2. Push Window (bottom)  W indow (side) to select Double . T wo file windows are displayed. 3. Push Select (side) to select the active window . 4. Push Directory (bottom)  Up Lev ...

  • Tektronix 070-A830-51 - page 74

    Operating Basics 2-32 A WG710 Service Manual Y ou can delete a file or directory by doing the following steps:  . Y ou cannot delete a file or dir ectory if the file or dir ectory is set to ’read only’. Also, you can only delete a dir ectory if the dir ectory is empty . 1. Push EDIT (front). The instrument displays the file list. 2. ...

  • Tektronix 070-A830-51 - page 75

    Operating Basics A WG710 Service Manual 2-33            Figure 2-17: Files and directories with read only attribute Saving files takes place from within each editor screen. Y ou have ...

  • Tektronix 070-A830-51 - page 76

    Operating Basics 2-34 A WG710 Service Manual  . When you exit an editor without saving edited data, the instrument displays the message Save the changes you made? Push the Y es side button to save the waveform data. T o save waveform data to a new file name, push File (bottom)  Save As (pop-up)  OK (side). The instrument opens the ...

  • Tektronix 070-A830-51 - page 77

    Operating Basics A WG710 Service Manual 2-35 3. Push Directory (bottom)  Ar chive (side). The instrument displays the Input archive name dialog box. By default, the name of <directory name>.tar is automatically assigned. If necessary , you can change the name. 4. Push OK button, and the archive file will be created in the current directory ...

  • Tektronix 070-A830-51 - page 78

    Operating Basics 2-36 A WG710 Service Manual Double Windows When the Window bottom button is displayed, you can split the file list in the Edit Screen into two lists as shown in Figure 2–19. This function is called Double W indows.     Figure 2-19: Double windows In Double W indows ...

  • Tektronix 070-A830-51 - page 79

    Operating Basics A WG710 Service Manual 2-37 window . Push the Select side button once more to select Lower for file operation in the lower file list window . The most useful functions in the Double W indows may be those invoked from the File bottom button. The functions available in the File bottom button are described in T able 2–11. T able 2-1 ...

  • Tektronix 070-A830-51 - page 80

    Operating Basics 2-38 A WG710 Service Manual Figure 2-20: Overwrite confirmation T able 2-12: Confirmation selection for copyĆall and moveĆall operations Side menu Description            ? ...

  • Tektronix 070-A830-51 - page 81

    Operating Basics A WG710 Service Manual 2-39 Figure 2-21: File list window examples in which quick view is available Select a file from the file list window using the general purpose knob. Press the SHIFT and ENTER front panel buttons simultaneously . The view window displays the waveform or pattern as shown in Figure 2–22. Figure 2-22: Viewing a ...

  • Tektronix 070-A830-51 - page 82

    Operating Basics 2-40 A WG710 Service Manual Setup Overview The Setup screen is where you load and set up the waveform for output. This section gives you an overview of the Setup screen, how to load a file, how to set the signal output parameters, and how to enable signal output. Refer to The Setup Menu Scr een in the Refer ence section of User man ...

  • Tektronix 070-A830-51 - page 83

    Operating Basics A WG710 Service Manual 2-41 T able 2-13: Setup screen parameter icons Icon Description Icon Description Displays the file name of the waveform, pattern, or sequence file loaded for output. Note: Use the View button to display the loaded waveform. Displays the noise signal level added. Displays the lowĆpass filter setting through w ...

  • Tektronix 070-A830-51 - page 84

    Operating Basics 2-42 A WG710 Service Manual Use the Setup menu to set up parameters for each channel as well as the instrument. Set up the file to load, amplitude, and run mode for each channel. Set up the Horizontal, Run Mode, and T rigger for the instrument. Do the following steps to load a waveform file into the Setup screen: 1. Push the W avef ...

  • Tektronix 070-A830-51 - page 85

    Operating Basics A WG710 Service Manual 2-43 buffer are completely independent. So, you can edit a waveform, pattern, sequence or equation/text while outputting an another waveform or sequence. However , when you push SETUP (front panel)  W aveform/Sequence (bottom)  Edit (side) to copy the waveform in the waveform memory to the edit buffer , ...

  • Tektronix 070-A830-51 - page 86

    Operating Basics 2-44 A WG710 Service Manual Note that the view function always display the waveform in the file that you specified, but not the waveform in the waveform memory . Even when you change the waveform with the editor and update the waveform memory , the view function still displays the waveform before the update unless you do not save t ...

  • Tektronix 070-A830-51 - page 87

    Operating Basics A WG710 Service Manual 2-45 T able 2-15: Setup output parameter operations (cont.) Bottom button Description Side button Horizontal Clock Sets the clock sample rate from 10 kS/s to 200 MS/s. Clock Src Sets the clock source to either Internal or External. When set to Internal, 10 MHz internal reference clock is used. When set to Ext ...

  • Tektronix 070-A830-51 - page 88

    Operating Basics 2-46 A WG710 Service Manual The waveform or pattern file contains only waveform and clock information. When you load a waveform or pattern file, the output signal will use the current instrument setup parameters. T o save you from doing a manual setup procedure each time you load a waveform, the A WG710 Arbitrary W aveform Generato ...

  • Tektronix 070-A830-51 - page 89

    A WG710 Service Manual 3-1 TheoryĂofĂOperation This section presents an overview of the A WG710 Arbitrary W aveform Generator hardware, data structures, and operating modes to allow you to take full advantage of the capabilities of the waveform generator . Figure 3–1 illustrates the waveform generator circuitry . This section describes the hard ...

  • Tektronix 070-A830-51 - page 90

    Theory of Operation 3-2 A WG710 Service Manual Clock 10 MHz Ref Out 10 MHz Ref In T rigger input 1/4 Clock output Event input A WG Board Memory Power supply Analog output Marker 1 Marker 1 Back plane GPIB LAN LAN Conn 100/10 Base T CPU Board Memory Memory Flash disk 10 MB Hard disk 10 GB Fan Fan Fan Connector Board LCD Front panel Monitor output FD ...

  • Tektronix 070-A830-51 - page 91

    Theory of Operation A WG710 Service Manual 3-3 Figure 3–2 shows the main hardware blocks that comprise the A WG710 Arbitrary W aveform Generator . ĂĂĂĂĂVCO EXTĂREF CLOCK (10ĂMHz) 1/4 CLOCK OUT EXT TRIG ĂIN EXT EVENT IN Event control Memory address control Analog output circuit CH1 CH1 MARKER1 MARKER1 22 4 DAC W aveform Ămemory Shift regi ...

  • Tektronix 070-A830-51 - page 92

    Theory of Operation 3-4 A WG710 Service Manual Clock Oscillator . Y ou can select either the internal or external reference clock source by using the SETUP horizontal menu. If you select the external source, the reference signal connected to the 10 MHz REF In connector on the rear panel will be used. The internal clock is from the reference clock o ...

  • Tektronix 070-A830-51 - page 93

    Theory of Operation A WG710 Service Manual 3-5 T able 3-1: Run modes (Cont.) Modes Descriptions %  (' # $ &%!&% * (   )%# %## $ #  %    % #  % ## !  ? ...

  • Tektronix 070-A830-51 - page 94

    Theory of Operation 3-6 A WG710 Service Manual                 ? ...

  • Tektronix 070-A830-51 - page 95

    Theory of Operation A WG710 Service Manual 3-7 Signal Edit Process This subsection describes the signal edit process. Load the desired waveform data to be output into the waveform memory . New waveform data can be created using waveform editors incorporated in the A WG710 Arbitrary W aveform Generator . New data can also be created by combining the ...

  • Tektronix 070-A830-51 - page 96

    Theory of Operation 3-8 A WG710 Service Manual T o edit waveforms, the A WG710 Arbitrary W aveform Generator provides you with W aveform, Pattern, Sequence, Equation, and T ext Editors. See T able 3–2 for a description of those editors. T able 3-2: Editors Editors Descriptions W aveform Editor The W aveform Editor lets you create or edit a wavefo ...

  • Tektronix 070-A830-51 - page 97

    A WG710 Service Manual 4-1 Performance V erification Y ou can perform two types of Performance V erification procedures with this product: Self T ests and Performance T ests . Y ou may not need to perform all these procedures, depending on what you want to accomplish.  V erify that the A WG710 Arbitrary W aveform Generator is operating correctly ...

  • Tektronix 070-A830-51 - page 98

    Performance V erification 4-2 A WG710 Service Manual Conventions Throughout these procedures the following conventions apply:  Each test procedure uses the following general format: T itle of T est Equipment Required Prerequisites Procedure  Each procedure consists of as many steps, substeps, and subparts as required to do the test. Steps, su ...

  • Tektronix 070-A830-51 - page 99

    Performance V erification A WG710 Service Manual 4-3 Self T ests Self T ests use internal routines to confirm basic functionality and proper adjustment. No test equipment is required to do these test procedures. The self tests include internal diagnostics to verify that the instrument passes the internal circuit tests, and calibration routines to c ...

  • Tektronix 070-A830-51 - page 100

    Performance V erification 4-4 A WG710 Service Manual Figure 4-1: Diagnostic menu Push the Execute Diagnostic side button to execute all of the A WG710 Arbitrary W aveform Generator diagnostics automatically .  . Push the Abort Diagnostic button (side menu) to stop a selected diagnos- tic after it is completed. This button does not stop ...

  • Tektronix 070-A830-51 - page 101

    Performance V erification A WG710 Service Manual 4-5 The instrument includes internal calibration routines that check electrical characteristics such as offset, attenuations and filters. Perform calibration to adjust internal calibration constants as necessary . This procedure describes how to do the internal calibration. Equipment required ? ...

  • Tektronix 070-A830-51 - page 102

    Performance V erification 4-6 A WG710 Service Manual Figure 4-2: Calibration result message box (except option 02) V erify that no failures are found and reported in the message box. If the calibration displays Fail as the result, consult a qualified service technician for further assistance. 2. Push the OK side button and then any bottom or menu b ...

  • Tektronix 070-A830-51 - page 103

    Performance V erification A WG710 Service Manual 4-7 Performance T ests This subsection contains a collection of procedures for checking that the A WG710 Arbitrary W aveform Generator performs as warranted. The procedures are arranged in eight logical groupings, presented in the following order: T able 4-1: Performance test items Titles See (perfor ...

  • Tektronix 070-A830-51 - page 104

    Performance V erification 4-8 A WG710 Service Manual The tests in this section produce an extensive, valid confirmation of performance and functionality when the following requirements are met: H The cabinet must be installed on the instrument. H Y ou must have performed and passed the procedures under Self T ests, found on page 4–3. H The wavefo ...

  • Tektronix 070-A830-51 - page 105

    Performance V erification A WG710 Service Manual 4-9 T able 4-2: T est equipment (cont.) Item number and description Purpose Example (recommended) Minimum requirements 10. BNCĆT Connector BNC (male) to BNC (female) to BNC (female) T ektronix part number 103Ć0030Ć00 Signal interconnection 1 1. DualĆBanana Connector BNC (female) to dual banana T ...

  • Tektronix 070-A830-51 - page 106

    Performance V erification 4-10 A WG710 Service Manual The following steps explain how to load files from the Performance Check/Ad- justment disk into the waveform memory and/or sequence memory . 1. Insert the disk into the A WG710 Arbitrary W aveform Generator floppy disk drive. 2. Select SETUP (front)  W aveform/Sequence (bottom)  Load... (s ...

  • Tektronix 070-A830-51 - page 107

    Performance V erification A WG710 Service Manual 4-1 1  . The floppy disk file list displayed on the scr een does not automatically update when you r eplace the diskette with another diskette. T o update the file list, r eselect the floppy disk drive. T able 4–3 lists the sequence and waveform files on the Performance Check/Ad- justme ...

  • Tektronix 070-A830-51 - page 108

    Performance V erification 4-12 A WG710 Service Manual T able 4-3: W aveforms and sequences in performance check disk (cont.) No. Usage Marker setup SETUP menu EDIT menu File name No. Usage Marker setup Offset Ampl Filter Clock Points Form File name 9 TRIG.WFM 1000 1 MHz Through 1ĂV 0ĂV T rigger input 10 PT_EVENT .SEQ Event input 11 PT_STROB.SEQ E ...

  • Tektronix 070-A830-51 - page 109

    Performance V erification A WG710 Service Manual 4-13 A WG710 T est Record Photocopy this test record and use to record the performance test results for your A WG710 Arbitrary W aveform Generator . A WG710 T est Record Instrument Serial Number:ą Certificate Number:ą T emperature:ą RH %:ą Date of Calibration:ą T echnician:ą A WG710 Performance ...

  • Tektronix 070-A830-51 - page 110

    Performance V erification 4-14 A WG710 Service Manual A WG710 T est Record (cont.) Instrument Serial Number:ą Certificate Number:ą T emperature:ą RH %:ą Date of Calibration:ą T echnician:ą A WG710 Performance T est Maximum Outgoing Incoming Minimum Amplitude, Of fset Accuracy and Rise Time (Direct DA Out) CH1 Amplitude 20 mV 1V 17.60 mV 0.978 ...

  • Tektronix 070-A830-51 - page 111

    Performance V erification A WG710 Service Manual 4-15 A WG710 T est Record (cont.) Instrument Serial Number:ą Certificate Number:ą T emperature:ą RH %:ą Date of Calibration:ą T echnician:ą A WG710 Performance T est Maximum Outgoing Incoming Minimum Negative Threshold (set the triggering level to -5 V) No trigger when input voltage vary f r o ...

  • Tektronix 070-A830-51 - page 112

    Performance V erification 4-16 A WG710 Service Manual Operating Mode T ests The following procedures verify the operation of the Cont, T riggered and Gated modes.  . When you output signals fr om the CH1 or CH1 OUTPUT , check that the other OUTPUT ( CH1 or CH1 ) LED is off. If the other OUT- PUT LED is on, push the CH1 or CH1 OUT button ...

  • Tektronix 070-A830-51 - page 113

    Performance V erification A WG710 Service Manual 4-17 Source . .................... C H 1 Coupling .................... D C Slope ...................... Positive Level ...................... +100 mV Mode . ..................... Auto Do the following steps to set the A WG710 Arbitrary W aveform Generator controls and to select the waveform file: 1. ...

  • Tektronix 070-A830-51 - page 114

    Performance V erification 4-18 A WG710 Service Manual Function Generator (AFG310) BNC T Adapter A WG710 Arbitrary Waveform Generator rear panel Output CH2 input CH1 input CH1 output OscilloscopeĂ(TDS784D) SMA (Female)ĆBNC (Male) adapter 50 W SMAĂcoaxial cable 50 W BNCĂcoaxial cable 50 W BNCĂcoaxial cable Figure 4-6: T riggered mode initial tes ...

  • Tektronix 070-A830-51 - page 115

    Performance V erification A WG710 Service Manual 4-19 6. Follow the substeps below to set the A WG710 Arbitrary W aveform Generator controls and to select the waveform file: a. Push UTILITY (front-panel)  System (bottom)  Factory Reset (side)  OK (side). b. Push SETUP (front-panel)  Run Mode (bottom)  T riggered (side) c. Load the MO ...

  • Tektronix 070-A830-51 - page 116

    Performance V erification 4-20 A WG710 Service Manual Equipment required T wo 50Ă W BNCĂcoaxial cables, aĂ50Ă W SMAĂcoaxial cable, ĂaĂSMA (female)ĆBNC (male)Ăadapter ,Ăa ĂBNCĆTĂ(male to 2 females) adapter , a function generator , and an oscilloscopeĂ(TDS784D). Prerequisites The A WG710 Arbitrary Waveform Generator must meet the prereq ...

  • Tektronix 070-A830-51 - page 117

    Performance V erification A WG710 Service Manual 4-21 e. Push 1 , 0 , 0 and M (SHIFT+7) keys in this order or turn the general purpose knob to set the internal clock frequency to 100 MHz. f. Push the RUN and CH1 output buttons. The LEDs above the RUN button and CH1 output connector are on. g. Push the FORCE TRIGGER button. V erify that the oscillos ...

  • Tektronix 070-A830-51 - page 118

    Performance V erification 4-22 A WG710 Service Manual Amplitude and Offset Accuracy T ests (Normal Out), (except option 02) These procedures check the accuracy of the amplitude and offset outputs of the A WG710 Arbitrary W aveform Generator .  . The amplitude and offset accuracy checks ar e structur ed as a continuous test. The next tes ...

  • Tektronix 070-A830-51 - page 119

    Performance V erification A WG710 Service Manual 4-23  DMM 50 W BNCĂcoaxial cable InputĂconnector +ĂBNCĆtoĆdual banana adapter +Ă50 W BNCĂcoaxialĂcable A WG710 Arbitrary Waveform Generator CH1ĂoutputĂconnector +ĂSMA(Ma)ĆBNC(Fe) adapter +ĂBNC 50 W Ăprecision terminator +Ă50 W ĂBNC coaxial cable Figure 4-9: Amplitude accuracy in ...

  • Tektronix 070-A830-51 - page 120

    Performance V erification  A WG710 Service Manual b. Push 0, ., 0, 2 and ENTER keys in this order or turn the general pur- pose knob to set the amplitude to 0.020 V . c. V erify that the offset setting display on the Of fset side button is 0.000 V . If the offset display is not set correctly , push the Offset side button, push 0 and the ...

  • Tektronix 070-A830-51 - page 121

    Performance V erification A WG710 Service Manual 4-25 9. Do the following substeps to change the connection to check the CH1 : a. Push the CH1 output button. b. Disconnect the adapter , terminator, and cable from the CH1 output con- nector . c. Connect the adapter, terminator , and cable (removed in step b) to the CH1 output connector . d. Push the ...

  • Tektronix 070-A830-51 - page 122

    Performance V erification  A WG710 Service Manual e. V erify that the reading on the DMM falls within 0.5 V ± 0.0175 V . f. Push - , 0 , . , 5 and ENTER keys in this order to change the A WG710 Arbitrary W aveform Generator offset to -0.5 V . g. Check that the reading on the DMM falls within -0.5 V ± 0.0175 V . 5. Do the following sub ...

  • Tektronix 070-A830-51 - page 123

    Performance V erification A WG710 Service Manual 4-27 Amplitude, Offset Accuracy and Rise Time T ests (Direct DA Out), (except option 02) These procedures check the accuracy of the A WG710 Arbitrary W aveform Generator direct waveform outputs; amplitude and offset. Equipment required A 50Ă W BNCĂcoaxial cable, a 50Ă W Ăprecision terminator , an ...

  • Tektronix 070-A830-51 - page 124

    Performance V erification  A WG710 Service Manual 4. Push SETUP (front-panel)  Run Mode (bottom)  Enhanced (side). The A WG710 Arbitrary W aveform Generator is set to enhanced mode. 5. Push VER TICAL MENU (front-panel)  Output (side)  Direct (side). 6. Load the AMP2.SEQ file. Refer to Loading Files on page 4–10 for file lo ...

  • Tektronix 070-A830-51 - page 125

    Performance V erification A WG710 Service Manual 4-29 b. Disconnect the adapter , terminator and cable from the CH1 output con- nector . c. Connect the adapter , terminator , and cable (removed in step b) to the CH1 output connector . d. Push the CH1 output button to turn on the CH1 LED. 12. Repeat step 8 through step 10 for the A WG710 Arbitrary W ...

  • Tektronix 070-A830-51 - page 126

    Performance V erification  A WG710 Service Manual              ...

  • Tektronix 070-A830-51 - page 127

    Performance V erification A WG710 Service Manual 4-31 Amplitude, Offset Accuracy and Rise Time T ests (for option 02) These procedures check the accuracy of the A WG710 Arbitrary W aveform Generator option 02 outputs; amplitude and offset. Equipment required A 50Ă W BNCĂcoaxial cable, a 50Ă W Ăprecision terminator , an SMA(Ma)ĆBNC(Fe)Ăadapter ...

  • Tektronix 070-A830-51 - page 128

    Performance V erification  A WG710 Service Manual 3. Push UTILITY (front-panel)  System (bottom)  Factory Reset (side)  OK (side). 4. Push SETUP (front-panel)  Run Mode (bottom)  Enhanced (side). The A WG710 Arbitrary W aveform Generator is set to enhanced mode. 5. Load the AMP2.SEQ file. Refer to Loading Files on page 4? ...

  • Tektronix 070-A830-51 - page 129

    Performance V erification A WG710 Service Manual 4-33 b. Disconnect the adapter , terminator and cable from the CH1 output con- nector . c. Connect the adapter , terminator , and cable (removed in step b) to the CH1 output connector . d. Push the CH1 output button to turn on the CH1 LED. e. Push the FORCE EVENT button. 11 . Repeat steps 7 through s ...

  • Tektronix 070-A830-51 - page 130

    Performance V erification  A WG710 Service Manual                    ? ...

  • Tektronix 070-A830-51 - page 131

    Performance V erification A WG710 Service Manual 4-35 Pulse Response T ests (Normal Out), (except option 02) This procedure checks the pulse response characteristics of the A WG710 Arbitrary W aveform Generator output waveforms at amplitudes of 1 V . Equipment required A 50Ă W SMAĂcoaxial cable and an oscilloscope (TDS820). Prerequisites The A WG ...

  • Tektronix 070-A830-51 - page 132

    Performance V erification  A WG710 Service Manual 4. Load the PULSE.WFM file. Refer to Loading Files on page 4–10 for file loading procedures. 5. Push the RUN and CH1 output buttons. The LEDs above the RUN button and CH1 output connector are on. 6. V erify the pulse response at 1 V amplitude. a. V erify that the rise time of the wavef ...

  • Tektronix 070-A830-51 - page 133

    Performance V erification A WG710 Service Manual 4-37 T rigger Input T ests These procedures check the trigger level accuracy of the A WG710 Arbitrary W aveform Generator . Equipment required T wo 50Ă W BNCĂcoaxial cables, aĂ50Ă W SMAĂcoaxial cable, ĂaĂSMA (female)ĆBNC (male)Ăadapter ,ĂaĂBNCĆTĂ(male to 2 females) adapter , a function g ...

  • Tektronix 070-A830-51 - page 134

    Performance V erification  A WG710 Service Manual CH1 input impedance . ......... 5 0 W CH2 input impedance . ......... 1 M W Horizontal Sweep . .................... 1 ms/div T rigger Source . .................... C H 1 Coupling .................... D C Slope ...................... Positive Level ...................... +100 mV Mode . .. ...

  • Tektronix 070-A830-51 - page 135

    Performance V erification A WG710 Service Manual 4-39 CH2 CH1       Figure 4-16: T rigger signal and waveform output (+5 V check 1) e. Change the pulse waveform high level to 5.35 V by using the arrow keys. f. Check that the sine waves are displayed on the oscilloscope ...

  • Tektronix 070-A830-51 - page 136

    Performance V erification 4-40 A WG710 Service Manual c. Check that no waveform is displayed on the oscilloscope as shown in Figure 4–18. CH2 CH1       Figure 4-18: T rigger signal and waveform output (-5 V check 1) d. Change the pulse waveform low level of function ...

  • Tektronix 070-A830-51 - page 137

    Performance V erification A WG710 Service Manual 4-41 Event Input and Enhanced Mode T ests These procedures check the event input signals and enhanced mode operation.  . The event input check with str obe off and the str obe input check are structur ed as a continuous test. After the Check Event Input with Strobe Off test is complete, t ...

  • Tektronix 070-A830-51 - page 138

    Performance V erification 4-42 A WG710 Service Manual               ...

  • Tektronix 070-A830-51 - page 139

    Performance V erification A WG710 Service Manual 4-43 c. V erify that the oscilloscope displays the waveform as shown in Figure 4–22 and that the waveform amplitude is the half size of Figure 4–21. Figure 4-22: W aveform output when the SW1 is closed d. Open SW1 of the ground closure to degenerate the event signal. e. V erify that the oscillosc ...

  • Tektronix 070-A830-51 - page 140

    Performance V erification 4-44 A WG710 Service Manual c. Open the SW2 of the ground closure to degenerate the event signal. d. V erify that the oscilloscope displays the waveform shown in Figure 4–21. 9. Check the EVENT IN connector pin 2 input: a. Close SW3 of the ground closure to generate an event signal on the EVENT IN connector pin 2. b. V e ...

  • Tektronix 070-A830-51 - page 141

    Performance V erification A WG710 Service Manual 4-45 Figure 4-25: W aveform output when SW4 is closed c. Open SW4 of the ground closure to degenerate the event signal. d. V erify that the oscilloscope displays the waveform in Figure 4–21. 11 . Retain the test hookup and control settings. Use the test hookup and oscilloscope settings from the Che ...

  • Tektronix 070-A830-51 - page 142

    Performance V erification 4-46 A WG710 Service Manual Figure 4-26: Initial waveform output b. Close SW5 of the ground closure to generate an event signal on the EVENT IN connector strobe pin. c. V erify that the oscilloscope displays the DC waveform as shown in Figure 4–27. Figure 4-27: DC waveform output when the SW5 is closed d. Open SW5 of the ...

  • Tektronix 070-A830-51 - page 143

    Performance V erification A WG710 Service Manual  g. V erify that the oscilloscope displays the waveform as shown in Figure 4–26. 4. Push the CH1 OUT button to turn off the CH1 LED. 5. Disconnect the oscilloscope and ground closure. ...

  • Tektronix 070-A830-51 - page 144

    Performance V erification 4-48 A WG710 Service Manual 1/4 Clock FrequencyĂandĂ10 MHz Reference Input T ests These procedures check the 10 MHz reference input function of the A WG710 Arbitrary W aveform Generator . Equipment required A 50Ă W SMA coaxial cable, A 50Ă W BNCĂcoaxial cable, aĂSMA(feĆ male)ĆBNC(male)Ăadapter ,Ăa frequency count ...

  • Tektronix 070-A830-51 - page 145

    Performance V erification A WG710 Service Manual 4-49 b. Set the function generator (AFG310) controls: "!   "   !"" ? ...

  • Tektronix 070-A830-51 - page 146

    Performance V erification 4-50 A WG710 Service Manual Marker Output T ests The following procedures check the accuracy of the A WG710 Arbitrary W aveform Generator marker output level.  . Connect a 50  SMA terminator to the inverted marker output connector during the marker output tests. Equipment required A 50Ă W BNCĂcoaxial cable ...

  • Tektronix 070-A830-51 - page 147

    Performance V erification A WG710 Service Manual  2. Set the DMM controls as follows:           ? ...

  • Tektronix 070-A830-51 - page 148

    Performance V erification  A WG710 Service Manual 7. Do the following substeps to change the connection to check the MARKER1 : a. Disconnect the 50 W precision terminator from the MARKER1 OUT con- nector . b. Disconnect the cable with SMA (male)–BNC (female) adapter and BNC 50 W terminator) from MARKER 1 OUT connector . c. Connect the ...

  • Tektronix 070-A830-51 - page 149

    A WG710 Service Manual 5-1 Adjustment Procedures This section provides the procedures necessary to manually adjust the A WG710 Arbitrary W aveform Generator . Overview This subsection contains the following topics:  Overview . Basic information about adjustment requirements  Befor e Adjustments . General information about adjusting the wavefo ...

  • Tektronix 070-A830-51 - page 150

    Adjustment Procedures 5-2 A WG710 Service Manual T able 5-2: Adjustments Adjustments Refer to               ? ...

  • Tektronix 070-A830-51 - page 151

    Adjustment Procedures A WG710 Service Manual 5-3 T able 5–3 lists the test equipment required to adjust the waveform generator . T able 5-3: T est equipment Item description Minimum requirements Example Purpose 1. Oscilloscope Bandwidth > 500 MHz T ektronix TDS784D Output signal adjustments 2. Frequency counter 1 MHz to 10 MHz Accuracy < 0. ...

  • Tektronix 070-A830-51 - page 152

    Adjustment Procedures 5-4 A WG710 Service Manual All the adjustment procedures are obtained through the Service menu which is a submenu of the Utility menu. T o enter this menu, you must enable the Service mode using the switch on the A10 Connector board. Perform the following step: Power on the waveform generator by pushing ON/STBY button while pr ...

  • Tektronix 070-A830-51 - page 153

    Adjustment Procedures A WG710 Service Manual 5-5 T able 5–4 lists the waveform file, provided on the Performance Check/Adjust- ment disk, that is required to do the adjustments. For instructions on loading files, see Operating Basics:Loading Files and the Refer ence:W aveform Sequence Menu section of the User Manual. After loading the files, push ...

  • Tektronix 070-A830-51 - page 154

    Adjustment Procedures 5-6 A WG710 Service Manual Adjustment Instructions This procedure adjusts Y5200 on the A50 A WG board to set the A WG710 Arbitrary W aveform Generator clock frequency . Equipment Required One frequency counter (Item 2) One 50 W coaxial cable (Item 3) Do the following steps to connect the test equipment and set the test equipme ...

  • Tektronix 070-A830-51 - page 155

    Adjustment Procedures A WG710 Service Manual 5-7 This procedure uses the general purpose knob on the front panel to set the Marker Output level. Equipment Required One oscilloscope (Item 1) One SMA 50 W coaxial cable (Item 4) SMA (female) to BNC (male) 50 W adapter (Item 5) 50 W SMA T erminator (Item 6) Do the following steps to connect the test eq ...

  • Tektronix 070-A830-51 - page 156

    Adjustment Procedures  A WG710 Service Manual 3. Do the following to set the waveform generator controls: Press UTILITY  System  Factory Reset  OK . 4. Follow the substeps below to load the waveform: a. Press SETUP  W aveform/Sequence  Load... b. T urn the general purpose knob to display the list of waveform files and highli ...

  • Tektronix 070-A830-51 - page 157

    Adjustment Procedures A WG710 Service Manual  9. Follow the substeps below to adjust the Marker 2 level: a. Press Marker 2 Adj. Level b. T urn the general purpose knob to adjust the waveform of marker low level voltage to 0.00 V within " 50 mV on the oscilloscope display . 10. Press Save to save the setting. 11 . Disconnect the oscill ...

  • Tektronix 070-A830-51 - page 158

    Adjustment Procedures 5-10 A WG710 Service Manual This procedure uses the general purpose knob on the front panel to set the Magic Frequency parameter . Equipment Required One oscilloscope (Item 1) One SMA 50 W coaxial cable (Item 4) SMA (Fe) to BNC (Ma) 50 W adapter (Item 5) Do the following steps to connect the test equipment and set test equipme ...

  • Tektronix 070-A830-51 - page 159

    Adjustment Procedures A WG710 Service Manual   3. Do the following to set the waveform generator controls: Press UTILITY  System  Factory Reset  OK . 4. Follow the substeps below to load the waveform: a. Press SETUP  W aveform/Sequence  Load... b. T urn the general purpose knob to display the list of waveform files and hi ...

  • Tektronix 070-A830-51 - page 160

    Adjustment Procedures  A WG710 Service Manual ...

  • Tektronix 070-A830-51 - page 161

    A WG710 Service Manual 6-1 Maintenance This section contains the information needed to perform periodic and corrective maintenance on the A WG710 Arbitrary W aveform Generator . The following subsections are included:  Related Maintenance Procedures. Provides information relating to various sections discussing maintenance.  Pr eparation. Intr ...

  • Tektronix 070-A830-51 - page 162

    Maintenance 6-2 A WG710 Service Manual Preparation Before servicing this product, read the Safety Summary and Intr oduction at the front of the manual and the ESD information below .  Static dischar ge can damage any semiconductor component in this generator . If you ar e r emoving a module for service, begin by doing the Ac ...

  • Tektronix 070-A830-51 - page 163

    Maintenance A WG710 Service Manual 6-3 T able 6–1 lists the relative susceptibility of various classes of semiconductors. Static voltages of 1 kV to 30 kV are common in unprotected environments. T able 6-1: Relative susceptibility to staticĆdischarge damage Semiconductor classes Relative susceptibility levels 1 MOS or CMOS microcircuits or discr ...

  • Tektronix 070-A830-51 - page 164

    Maintenance 6-4 A WG710 Service Manual Inspection and Cleaning Inspection and Cleaning describes how to inspect for dirt and damage. It also describes how to clean the exterior and interior of the A WG710 Arbitrary W aveform Generators. Inspection and cleaning are done as preventive mainte- nance. Preventive maintenance, when done regularly , may p ...

  • Tektronix 070-A830-51 - page 165

    Maintenance A WG710 Service Manual 6-5 Exterior Inspection. Examine the outside of the generator for damage, wear , and missing parts, using T able 6–2 as a guide. W aveform generators that appear to have been dropped or otherwise mishandled should be checked thoroughly to verify correct operation and performance. Immediately repair defects that ...

  • Tektronix 070-A830-51 - page 166

    Maintenance 6-6 A WG710 Service Manual Interior Inspection. T o access the inside of the waveform generator for inspection and cleaning, refer to the Removal and Installation Pr ocedur es in this section. Inspect the internal portions of the generator for damage and wear , using T able 6–3 as a guide. Defects found should be repaired immediately ...

  • Tektronix 070-A830-51 - page 167

    Maintenance A WG710 Service Manual 6-7 Interior Cleaning Procedure. Do the following steps to clean the generator interior: 1. Blow off dust with dry , low-pressure, deionized air (approximately 9 psi). 2. Remove any remaining dust with a lint-free cloth dampened in ethyl alcohol and rinse with warm deionized water . (A cotton-tipped applicator is ...

  • Tektronix 070-A830-51 - page 168

    Maintenance  A WG710 Service Manual ...

  • Tektronix 070-A830-51 - page 169

    A WG710 Service Manual 6-9 Removal and Installation Procedures This subsection contains procedures for removal and installation of all mechani- cal and electrical modules. Any electrical or mechanical module, assembly , or part listed in the Replaceable Mechanical Parts section of this manual is a module. Preparation Ċ Preparation for Use  ? ...

  • Tektronix 070-A830-51 - page 170

    Removal and Installation Procedures 6-10 A WG710 Service Manual The Replaceable Mechanical Parts section lists all modules. The following procedures are described in the order in which they appear in this section.  The Accsess Pr ocedur e on page 6–16 directs you to the procedure(s) (if any) that are required to access the module to be service ...

  • Tektronix 070-A830-51 - page 171

    Removal and Installation Procedures A WG710 Service Manual 6-1 1 T able 6-4: T ools required for module removal (Cont.) Item no. Description Name    ! ! !        Throughout ...

  • Tektronix 070-A830-51 - page 172

    Removal and Installation Procedures 6-12 A WG710 Service Manual                     ...

  • Tektronix 070-A830-51 - page 173

    Removal and Installation Procedures A WG710 Service Manual 6-13                     ...

  • Tektronix 070-A830-51 - page 174

    Removal and Installation Procedures 6-14 A WG710 Service Manual Display unit CPU module A40 PCI Interface GPIB interface Main chassis CPU unit Hard disk & Flash disk drive Figure 6-4: Internal modules(1) ...

  • Tektronix 070-A830-51 - page 175

    Removal and Installation Procedures A WG710 Service Manual 6-15        "     "   Figure 6-5: InternalĂmodules(2) * ? ...

  • Tektronix 070-A830-51 - page 176

    Removal and Installation Procedures 6-16 A WG710 Service Manual Accsess Procedure Begin with this procedure when you have identified which module to remove for service. 1. Find the module to remove in Figure 6–2 through 6–5. The title of the figure indicates whether the module is an external, internal module(1), or internal module(2) part. 2. I ...

  • Tektronix 070-A830-51 - page 177

    Removal and Installation Procedures A WG710 Service Manual 6-17 Procedures for External Modules Do the Accsess Pr ocedur e on page 6–16 before performing any of the procedures in this subsection. The following procedures are listed in the order presented.  Fr ont Panel Knobs  Line Fuse and Line Cor d  EMI Gaskets  Cabinet  T rim Ri ...

  • Tektronix 070-A830-51 - page 178

    Removal and Installation Procedures 6-18 A WG710 Service Manual                     ...

  • Tektronix 070-A830-51 - page 179

    Removal and Installation Procedures A WG710 Service Manual 6-19 Y ou will need a flat-blade screwdriver (T able 6–4, Item 4). Locate the line fuse and line cord in Figure 6–2.   T o avoid electrical shock, be sur e that the power cor d is disconnected fr om the socket befor e checking the line fuse. 1. Orient the generat ...

  • Tektronix 070-A830-51 - page 180

    Removal and Installation Procedures 6-20 A WG710 Service Manual Do the following cabinet procedure (see Figure 6–8). Y ou will need a screwdriver with a size Phillips #2 tip (T able 6–4, Items 1 and 3). 1. Make sure the front cover (optional accessory) is installed. If it is not, install it by snapping the edges over the trim ring. 2. Locate th ...

  • Tektronix 070-A830-51 - page 181

    Removal and Installation Procedures A WG710 Service Manual  b. When sliding the cabinet, be sure that the front edge of the cabinet aligns with the groove containing the EMI shield on the front casing. c. Be sure that the ridge around the rear chassis slides into the groove containing a second EMI cable at the rear of the cabinet. d. Wh ...

  • Tektronix 070-A830-51 - page 182

    Removal and Installation Procedures 6-22 A WG710 Service Manual Figure 6-8: Cabinet removal ...

  • Tektronix 070-A830-51 - page 183

    Removal and Installation Procedures A WG710 Service Manual 6-23 No tools are needed for this procedure. 1. Locate the modules to be removed in Figure 6–2, page 6–12. 2. Orient the generator so the rear is on the work surface and the bottom is facing you. 3. Remove the front cover by grasping it by the left and right edges and snap it off of the ...

  • Tektronix 070-A830-51 - page 184

    Removal and Installation Procedures 6-24 A WG710 Service Manual  T o pr event damage to the contacts, do not touch the carbon contact points on the menu buttons installed in the trim ring. Also, do not touch the contacts on the exposed flex cir cuit when you r emove the trim ring. 4. Remove the trim ring by grasping the top ...

  • Tektronix 070-A830-51 - page 185

    Removal and Installation Procedures A WG710 Service Manual 6-25                Figure 6-10: A20 Front panel assembly removal If the ...

  • Tektronix 070-A830-51 - page 186

    Removal and Installation Procedures 6-26 A WG710 Service Manual Figure 6-1 1: Disassembly of front panel assembly Y ou will need a screwdriver with a size Phillips #2 tip (T able 6–4, Items 1 and 3). 1. Locate the modules to be removed in Figure 6–2, page 6–12. 2. Do the T rim Ring and A20 Fr ont panel assembly procedures immediately precedin ...

  • Tektronix 070-A830-51 - page 187

    Removal and Installation Procedures A WG710 Service Manual 6-27   Figure 6-12: Output assembly removal Y ou will need a pair of needle-nose pliers (T able 6–4, Item 5). 1. Locate the modules to be removed in Figure 6–2, page 6–12. 2. Orient the waveform generator so the left side is on the work surfac ...

  • Tektronix 070-A830-51 - page 188

    Removal and Installation Procedures  A WG710 Service Manual 7. While using the pliers to expand the handle cap outward, grasp it and snap it off. 8. Repeat the procedure to remove the remaining cap as needed; push the cap(s) back on to install. 9. Remove the flip stand by grasping it on both sides where it joins each flip stand foot. No ...

  • Tektronix 070-A830-51 - page 189

    Removal and Installation Procedures A WG710 Service Manual 6-29                   ? ...

  • Tektronix 070-A830-51 - page 190

    Removal and Installation Procedures 6-30 A WG710 Service Manual Procedures for Internal Modules(1) Y ou must complete the Access Procedur e before doing any of the procedures described in this subsection. This subsection describes removal/installation procedures for the following modules:  Fan  Floppy disk drive  Display Assembly  PS100 ...

  • Tektronix 070-A830-51 - page 191

    Removal and Installation Procedures A WG710 Service Manual 6-31 Y ou will need a screwdriver with a size #2 Phillips tip (T able 6–4, Items 1 and 3). 1. Locate the fan in Figure 6–3 on page 6–13. 2. Orient the waveform generator so the bottom is on the work surface and the left side is facing you (see Figure 6–14). 3. Slide the cable connec ...

  • Tektronix 070-A830-51 - page 192

    Removal and Installation Procedures 6-32 A WG710 Service Manual Y ou will need as screwdriver with a size #1 Phillips tip (T able 6–4, Items 1 and 2). 1. Locate the modules to be removed, including those listed under Additional Modules Removed in Figure 6–3, page 6–13. 2. Orient the waveform generator so the top is on the work surface and the ...

  • Tektronix 070-A830-51 - page 193

    Removal and Installation Procedures A WG710 Service Manual 6-33 Y ou will need a screwdriver with a size #2 Phillips tip (T able 6–4, Items 1 and 3). 1. Locate the modules to be removed in Figure 6–3, on page 6–13. 2. Do the T rim Ring, Menu Button and A20 Fr ont Panel Assembly procedures immediately preceding this procedure. 3. Orient the wa ...

  • Tektronix 070-A830-51 - page 194

    Removal and Installation Procedures 6-34 A WG710 Service Manual 10. See the following procedures, in the order shown, to complete the reassemb- ly of the waveform generator:  A20 Fr ont Panel Assembly (page 6–24)  T rim Ring, Menu Buttons (page 6–23)  Cabinet (page 6–20) (completes reassembly) Y ou will need a screwdriver with a size ...

  • Tektronix 070-A830-51 - page 195

    Removal and Installation Procedures A WG710 Service Manual 6-35      Figure 6-17: Power supply module removal ...

  • Tektronix 070-A830-51 - page 196

    Removal and Installation Procedures 6-36 A WG710 Service Manual Y ou will need a screwdriver with a size #2 Phillips tip (T able 6–4, Items 1 and 3). 1. Locate the modules to be removed in Figure 6–3, page 6–13. 2. Orient the waveform generator so the bottom is on the work surface and the front is facing you. 3. T o disconnect the A10 Connect ...

  • Tektronix 070-A830-51 - page 197

    Removal and Installation Procedures A WG710 Service Manual 6-37 Figure 6-18: A10 connector board removal ...

  • Tektronix 070-A830-51 - page 198

    Removal and Installation Procedures 6-38 A WG710 Service Manual This procedure describes how to remove the following circuit boards that are contained in the CPU unit:  CPU board  Hard Disk and Flash Disk  A40 PCI Interface Board  GPIB Board  Back Plane  . The Lithium polycarbon monofluoride battery on the CPU boar d is n ...

  • Tektronix 070-A830-51 - page 199

    Removal and Installation Procedures A WG710 Service Manual 6-39 Figure 6-19: CPU unit removal 4. Remove the CPU board using Figure 6–20 as a guide while doing the following substeps: a. Use a screwdriver with a size #2 Phillips tip to remove the screw that secures the CPU board to the frame with a retainer on the the right side of the unit. b. Re ...

  • Tektronix 070-A830-51 - page 200

    Removal and Installation Procedures 6-40 A WG710 Service Manual         Figure 6-20: CPU, A40 PCI Interface, and GPIB boards removal 5. Remove the A40 PCI Interface board (using a screwdriver with a size #2 Phillips tip) by removing the sc ...

  • Tektronix 070-A830-51 - page 201

    Removal and Installation Procedures A WG710 Service Manual 6-41 This procedure describes how to remove the Hard Disk and Flash Disk unit. Y ou will need a screwdriver with a size Phillips #2 tip (T able 6–4, Items 1 and 3). 1. Locate the modules to be removed in Figure 6–4, page 6–14. 2. Orient the waveform generator so the bottom is on the w ...

  • Tektronix 070-A830-51 - page 202

    Removal and Installation Procedures 6-42 A WG710 Service Manual Y ou will need a screwdriver with a size #2 Phillips tip (T able 6–4, Items 1 and 3). 1. Locate the modules to be removed in Figure 6–3, page 6–13. 2. Do the PS100 Low V oltage Power Supply procedure (page 6–34) to remove the power supply module. 3. Install the front cover (opt ...

  • Tektronix 070-A830-51 - page 203

    Removal and Installation Procedures A WG710 Service Manual 6-43 IEEE STD 488 PORT to J1 10 10 BASE-T to the LAN interface KEYBOARD to J128 DISPLA Y MONITOR OUT to J127 EVENT IN to J200 10 MHz REF IN to J130 TRIG IN to J200 10 MHz REF OUT to J150 1/4 CLOCK OUT to J500 Figure 6-22: Rear chassis removal 6. T o install, do this procedure in the reverse ...

  • Tektronix 070-A830-51 - page 204

    Removal and Installation Procedures 6-44 A WG710 Service Manual Procedures for Internal Modules(2), Y ou must complete the Access Procedur e on page 6–16 before doing any of the procedures for the Internal modules(2). The procedures are presented in the following order:  A77 Attenuator Boar d (except option 02)  A72 Output Boar d (except op ...

  • Tektronix 070-A830-51 - page 205

    Removal and Installation Procedures A WG710 Service Manual 6-45           Figure 6-23: Removal of the A77, A71 and A50 boards (except option 02) ...

  • Tektronix 070-A830-51 - page 206

    Removal and Installation Procedures 6-46 A WG710 Service Manual Y ou will need a screwdriver with a size #2 Phillips tip (T able 6–4, Items 1 and 3). 1. Locate the modules to be removed in Figure 6–5, page 6–15. 2. Orient the waveform generator so its top is down on the work surface and its front is facing you. 3. Perform the A77 Attenuator B ...

  • Tektronix 070-A830-51 - page 207

    Removal and Installation Procedures A WG710 Service Manual 6-47 Y ou will need a screwdriver with a size #2 Phillips tip (T able 6–4, Items 1 and 3) and a nutdriver 5.5 mm (T able 6–4, Item 7). 1. Locate the modules to be removed in Figure 6–5, page 6–15. 2. Orient the waveform generator so the top is on the work surface and the rear is fac ...

  • Tektronix 070-A830-51 - page 208

    Removal and Installation Procedures 6-48 A WG710 Service Manual        Figure 6-24: Removal of the A77, A72 and A50 boards (for option 02) ...

  • Tektronix 070-A830-51 - page 209

    Removal and Installation Procedures A WG710 Service Manual 6-49 Y ou will need a screwdriver with a size #2 Phillips tip (T able 6–4 of page6–10, Items 1, 3 and 15). 1. Locate the modules to be removed in Figure 6–5, page 6–15. 2. Orient the waveform generator so its top is down on the work surface and its front is facing you. 3. Unplug the ...

  • Tektronix 070-A830-51 - page 210

    Removal and Installation Procedures  A WG710 Service Manual ...

  • Tektronix 070-A830-51 - page 211

    A WG710 Service Manual 6-51 T roubleshooting This subsection contains information and procedures designed to help you isolate faulty modules in the waveform generator . If a module needs to be replaced, follow the Removal and Installation Pr ocedur es in this section. This subsection consists of the following flowcharts:  Figure 6–25: Primary ...

  • Tektronix 070-A830-51 - page 212

    Removal and Installation Procedures 6-52 A WG710 Service Manual Press the PRINCIP AL POWER SWITCH to OFF and remove the cover using the Rear Cover and Cabinet removal procedure. Check all the cables coming out of the power supply module and the cabling between modules. Be sure every cable is attached securely . Press the PRINCIP AL POWER SWITCH on ...

  • Tektronix 070-A830-51 - page 213

    Removal and Installation Procedures A WG710 Service Manual 6-53 Use this procedure to troubleshoot the power supply module. Is the PRINCIP AL POWER SWITCH in the ON position? Is line fuse ok? T urn off the PRINCIP AL POWER SWITCH . Replace the fuse. T urn on the principal power switch. Fix the power problem. Replace the power supply module (page 6- ...

  • Tektronix 070-A830-51 - page 214

    Removal and Installation Procedures 6-54 A WG710 Service Manual 16 15 14 13 12 1 1 10 9 86 7 54321 +5 V GND +12 V NC -5 V *Power Fail *Remote On -5 V GND 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 -2 V *15 V/8 Vsel -8 V +8 V J10 on the A10 Connector board (See above for the pin assignment) J1 J2 J3 14 13 12 1 1 10 9 8 75 6 4321 +5 V GND J1 J2 +12 ...

  • Tektronix 070-A830-51 - page 215

    Removal and Installation Procedures A WG710 Service Manual 6-55 Do all front panel LEDs turn on and the P ANEL LOCK LED blink for a while? The front panel module is ok. Replace the CPU module. T urn on the PRINCIP AL POWER SWITCH on the rear panel, and then turn on the ON/STBY button on the front panel Is the voltage of TP030 on A10 board : 5 V (se ...

  • Tektronix 070-A830-51 - page 216

    Removal and Installation Procedures 6-56 A WG710 Service Manual Is a screen pitch-black? The voltage of TP030 on the A10 connector board is +5 V and TP010 is +12 V? Are the 50 pin flat cable connected to J220 on A10 board and the cable connected toĂJ225 on A10 board securelyĂinstalled in their sockets and are the cables ok? Securely install and/o ...

  • Tektronix 070-A830-51 - page 217

    Removal and Installation Procedures A WG710 Service Manual 6-57                        ? ...

  • Tektronix 070-A830-51 - page 218

    Removal and Installation Procedures 6-58 A WG710 Service Manual    System A50 A WG board (page 6-47) Run mode Check all cables. Be sure every cable is attached securely . Replace the module indicated in the diagnostics. Run all diagnostics. Can the data be read or written from/ ...

  • Tektronix 070-A830-51 - page 219

    6-59 A WG710 Service Manual Messages and Codes Error and event codes with negative values are SCPI standard codes. Error and event codes with positive values are unique to the waveform generator series number . T able 6–5 lists event code definitions. When an error occurs, you can find its error class by checking for its the code range in T ables ...

  • Tektronix 070-A830-51 - page 220

    Messages and Codes 6-60 A WG710 Service Manual Command Errors Command errors are returned when there is a syntax error in the command. T able 6-6: Command errors Error code Error message -100 Command error -101 Invalid character -102 Syntax error -103 Invalid separator -104 Data type error -105 GET not allowed -108 Parameter not allowed -109 Missin ...

  • Tektronix 070-A830-51 - page 221

    Messages and Codes 6-61 A WG710 Service Manual T able 6-6: Command errors (Cont.) Error code Error message  #&    $ !#&  #& "   #& " %   & ...

  • Tektronix 070-A830-51 - page 222

    Messages and Codes 6-62 A WG710 Service Manual Execution Errors These error codes are returned when an error is detected during command execution. T able 6-7: Execution errors Error code Error message -200 Execution error -201 Invalid while in local -202 Settings lost due to RTL -203 Command protected -210 T rigger error -21 1 T rigger ignored -212 ...

  • Tektronix 070-A830-51 - page 223

    Messages and Codes 6-63 A WG710 Service Manual T able 6-7: Execution errors (Cont.) Error code Error message -253 Corrupt media -254 Media full -255 Directory full -256 File name not found -257 File name error -258 Media protected -260 Expression error -261 Math error in expression -270 Macro error -271 Macro syntax error -272 Macro execution error ...

  • Tektronix 070-A830-51 - page 224

    Messages and Codes 6-64 A WG710 Service Manual Device Specific Errors These error codes are returned when an internal instrument error is detected. This type of error can indicate a hardware problem. T able 6-8: Device specific errors Error code Error message -300 Device specific error -310 System error -31 1 Memory error -312 PUD memory lost -313 ...

  • Tektronix 070-A830-51 - page 225

    Messages and Codes 6-65 A WG710 Service Manual Query Errors These error codes are returned in response to an unanswered query . T able 6-9: Query errors Error code Error message  $!& !!!  $!&   $!&    $! ...

  • Tektronix 070-A830-51 - page 226

    Messages and Codes 6-66 A WG710 Service Manual Request Control Events This event is unused in the A WG710 W aveform Generator . T able 6-12: Request control events Event code Event message    Operation Complete Events This event occurs when the synchronization protocol, having been enabled by an ...

  • Tektronix 070-A830-51 - page 227

    Messages and Codes 6-67 A WG710 Service Manual Device Errors T able 6–14 lists A WG400 series error code and their meaning. T able 6-14: Messages and codes ErĆ rorĂcode ErrorĂmessage RelatedĂmodule SupplementaryĂInformation /* ---- Calibration ---- */ 1 101 CH1 internal offset calibration failure A71 (Output)/A77 (A TT) Check A71 (Output), A ...

  • Tektronix 070-A830-51 - page 228

    Messages and Codes 6-68 A WG710 Service Manual T able 6-14: Messages and codes (Cont.) ErĆ rorĂcode SupplementaryĂInformation RelatedĂmodule ErrorĂmessage 1744 CH1 200MHz Filter calibration failure A71 (Output)/A77 (A TT) Check A71 (Output), A77 (A TT) and connection. 1801 CH1 Reference level calibration failure A71 (Output) Check A71 (Output) ...

  • Tektronix 070-A830-51 - page 229

    Messages and Codes 6-69 A WG710 Service Manual T able 6-14: Messages and codes (Cont.) ErĆ rorĂcode SupplementaryĂInformation RelatedĂmodule ErrorĂmessage 4100 PLL lock/unlock failure A50 (A WG) Check A50 (A WG). /* ---- Sequence Memory Diagnostics ---- */ 5000 Sequence memory failure A50 (AWG) Check A50 (A WG). 5100 Sequence memory data bus f ...

  • Tektronix 070-A830-51 - page 230

    Messages and Codes 6-70 A WG710 Service Manual T able 6-14: Messages and codes (Cont.) ErĆ rorĂcode SupplementaryĂInformation RelatedĂmodule ErrorĂmessage 7201 CH1 output of fset failure A71 (Output)/A77 (A TT) Check A71 (Output), A77 (A TT) and connection. 7204 CH1 output of fset failure A71 (Output)/A77 (A TT) Check A71 (Output), A77 (A TT) ...

  • Tektronix 070-A830-51 - page 231

    Messages and Codes 6-71 A WG710 Service Manual T able 6-14: Messages and codes (Cont.) ErĆ rorĂcode SupplementaryĂInformation RelatedĂmodule ErrorĂmessage 7704 Reference level failure A71 (Output)/A77 (A TT) Check A71 (Output), A77 (A TT) and connection. 91 1 1 W aveform/Sequence load error: waveform memory full - 91 12 W aveform/Sequence load ...

  • Tektronix 070-A830-51 - page 232

    Messages and Codes  A WG710 Service Manual ...

  • Tektronix 070-A830-51 - page 233

    A WG710 Service Manual 7-1 Options and Accessories This subsection describes the various options as well as the standard and optional accessories that are available for the A WG710 Arbitrary W aveform Generator . Power Cord Options T able7–1 lists the power cords available with the A WG710 Arbitrary W aveform Generator . T able 7-1: Power cord op ...

  • Tektronix 070-A830-51 - page 234

    Options and Accessories 7-2 A WG710 Service Manual Options This subsection describes the following options available with the A WG710 Arbitrary W aveform Generator Arbitrary W aveform Generator: A WG710 Arbitrary W aveform Generator . comes configured for installation in a 19-inch wide instrument rack. For later field conversions, order Rack Mount ...

  • Tektronix 070-A830-51 - page 235

    Options and Accessories A WG710 Service Manual 7-3 Accessories The A WG710 Arbitrary W aveform Generator includes the standard accessories listed in T able 7–2. T able 7-2: Standard accessories Accessory Part number User Manual 070ĆA828Ć50 Programmer Manual 070ĆA829Ć50 Sample waveform floppy disk, 3.5 inch 062ĆA271ĆXX Sample program floppy ...

  • Tektronix 070-A830-51 - page 236

    Options and Accessories 7-4 A WG710 Service Manual T able 7-3: Optional accessories (cont.) Accessory Part number SMA 50 W divider , Male 015Ć1014Ć00 SMA delay cable, 1 ns, MaleĆMale 015Ć0562Ć00 SMAĆBNC adapter , MaleĆFemale 015Ć0554Ć00 SMAĆBNC adapter , FemaleĆMale 015Ć0572Ć00 SMA adapter kit 020Ć 1693Ć00 BNC terminator , 50 W 01 1? ...

  • Tektronix 070-A830-51 - page 237

    A WG710 Service Manual 8-1 Electrical Parts List The modules that comprise this instrument are a combination of mechanical and electrical subparts. Therefore, all replaceable modules are listed in Replaceable Mechanical Parts. Refer to that section for part numbers when using this manual. ...

  • Tektronix 070-A830-51 - page 238

    Electrical Parts List  A WG710 Service Manual ...

  • Tektronix 070-A830-51 - page 239

    A WG710 Service Manual 9-1 Diagrams This section contains the Block & Interconnect Diagram for the A WG710 Arbitrary W aveform Generator . This diagram shows the modules and functional blocks in the waveform generator . In addition, it illustrates how the modules in the waveform generator are connected (see Figure 9–1). ...

  • Tektronix 070-A830-51 - page 240

    Diagrams 9-2 A WG710 Service Manual Figure 9-1: Block and interconnect diagram for the A WG710 Arbitrary W aveform Generator PCI Backplane J5100 10MNz REF OUT 10MH REF IN 1/4 CLOCK OUT TRIG IN EVENT Input J1000 A50 AWG BOARD CPU Board LAN LCD COM2 MISC FDD VGA COM1 GPIB Card A40 PCI Interface Board A71 OUTPUT J5401 J5400 CH1 ANALOG OUT CH1 ANALOG O ...

  • Tektronix 070-A830-51 - page 241

    Diagrams A WG710 Service Manual 9-3 Cable Assembling Parts List T ektronix part number Connection point. A Connection point. B 174-B938-00 A50 A WG Board:J5230 10MHz REF OUT 174-B939-00 A50 A WG Board:J5210 10MHz REF IN 174-B643-00 A50 A WG Board:J5450 1/4 CLOCK OUT 174-B940-00 A50 AWG Board:J5100 TRIG IN 174-3878-00 A50 A WG Board:J1000 EVENT INPU ...

  • Tektronix 070-A830-51 - page 242

    Diagrams 9-4 A WG710 Service Manual Cable Assembling Parts List (Cont.) T ektronix part number Connection point. B Connection point. A 174-B338-00 A10 CONNECTOR Board:J1 12 A90 Key Board 174-B329-01 A10 CONNECTOR Board:J102 FLOPPY DISK DRIVE 174-B926-00 A10 CONNECTOR Board:J225 TFT LCD 174-3879-00 A10 CONNECTOR Board:J152 MONITOR OUT(15pin,D-Sub) 1 ...

  • Tektronix 070-A830-51 - page 243

    A WG710 Service Manual 10-1 Replaceable Mechanical Parts This section contains a list of the replaceable modules for the A WG710 Arbitrary W aveform Generator . Use this list to identify and order replacement parts. Parts Ordering Information Replacement parts are available through your local T ektronix field office or representative. Changes to T ...

  • Tektronix 070-A830-51 - page 244

    Replaceable Mechanical Parts 10-2 A WG710 Service Manual Modules can be serviced by selecting one of the following three options. Contact your local T ektronix service center or representative for repair assistance. Module Exchange. In some cases you may exchange your module for a reman- ufactured module. These modules cost significantly less than ...

  • Tektronix 070-A830-51 - page 245

    Replaceable Mechanical Parts A WG710 Service Manual 10-3 Manufacturers Cross Index Mfr . Code Manufacturer Address City , state, zip code S3109 FELLER 72 VERONICA A VE UNIT 4 SUMMERSET NJ 08873 TK0392 NORTHWEST F ASTENER SALES INC 8058 SW NIMBUS A VENUE BEA VERTON OR 97008 TK0435 LEWIS SCREW CO 4300 S RACINE A VE CHICAGO IL 60609-3320 TK1 163 POL Y ...

  • Tektronix 070-A830-51 - page 246

    Replaceable Mechanical Parts 10-4 A WG710 Service Manual Replaceable Parts List Fig. & index number T ektronix part number Serial no. effective Serial no. discont'd Qty Name & description Mfr . code Mfr . part number 1-1 334-A580-01 1 MARKER, IDENT :MKD AWG710, POL YCARBONA TE 334-A580-01 ĂĂĂ-2 101-0142-01 1 TRIM,DECORA TIVE:FRONT , ...

  • Tektronix 070-A830-51 - page 247

    Replaceable Mechanical Parts A WG710 Service Manual 10-5                    Figure 10-1: Front and Display unit ...

  • Tektronix 070-A830-51 - page 248

    Replaceable Mechanical Parts 10-6 A WG710 Service Manual Replaceable Parts List Fig. & index number T ektronix part number Serial no. effective Serial no. discont'd Qty Name & description Mfr . code Mfr . part number 2-1 333-A414-00 1 P ANEL, FRONT : KEYBOARD, AWG710, POL YCARBONA TE 333-A414-00 ĂĂĂ-2 386-A838-00 1 SUBP ANEL, FRONT ...

  • Tektronix 070-A830-51 - page 249

    Replaceable Mechanical Parts A WG710 Service Manual 10-7               Figure 10-2: Front panel ...

  • Tektronix 070-A830-51 - page 250

    Replaceable Mechanical Parts 10-8 A WG710 Service Manual Replaceable Parts List (except option 02) Fig. & index number T ektronix part number Serial no. effective Serial no. discont'd Qty Name & description Mfr . code Mfr . part number 3-1 174-B649-00 1 CA ASSY ,RF:50 OHM COAX,15CM L,9-1,SMA TO PEL TORA, SST SHELL 174-B649-00 ĂĂĂ-2 ...

  • Tektronix 070-A830-51 - page 251

    Replaceable Mechanical Parts A WG710 Service Manual 10-9                             ∼      Figure 10-3: Front Output unit (except option 02) ...

  • Tektronix 070-A830-51 - page 252

    Replaceable Mechanical Parts 10-10 A WG710 Service Manual Replaceable Parts List (for option 02) Fig. & index number T ektronix part number Serial no. effective Serial no. discont'd Qty Name & description Mfr . code Mfr . part number 4-1 174-B934-00 1 W5510, 45CM L, MKD 1, SMA TO PEL TRA 174-B934-00 ĂĂĂ-2 174-B935-00 1 W551 1, 45CM ...

  • Tektronix 070-A830-51 - page 253

    Replaceable Mechanical Parts A WG710 Service Manual 10-1 1                            ∼ ∼        Figure 10-4: Front Output unit (for option 02) ...

  • Tektronix 070-A830-51 - page 254

    Replaceable Mechanical Parts 10-12 A WG710 Service Manual Replaceable Parts List Fig. & index number T ektronix part number Serial no. effective Serial no. discont'd Qty Name & description Mfr . code Mfr . part number 5-1 441-A282-00 1 CHASSIS, ASSY:CPU, AL, See Fig 10-5 441-A282-00 ĂĂĂ-2 21 1-0945-00 SCREW , MACHINE:M4X8MM L,STL,ZN ...

  • Tektronix 070-A830-51 - page 255

    Replaceable Mechanical Parts A WG710 Service Manual 10-13 Replaceable Parts List (Cont.) Fig. & index number Mfr . part number Mfr . code Name & description Qty Serial no. discont'd Serial no. effective T ektronix part number ĂĂĂ-33 129-A229-00 4 SP ACER, POST :20.OMML, M4 INT/EXT THD, 7MM HEX,STL ZN-C PL UN237-P4 ĂĂĂ-34 210-0008 ...

  • Tektronix 070-A830-51 - page 256

    Replaceable Mechanical Parts 10-14 A WG710 Service Manual Replaceable Parts List Fig. & index number T ektronix part number Serial no. effective Serial no. discont'd Qty Name & description Mfr . code Mfr . part number 6-1 441-A282-00 1 CHASSIS, ASSY:CPU, AL, A WG710 441-A282-00 ĂĂĂ-2 343-A345-00 1 RET AINER,CKT BD:CPU,AL,AWG710 343- ...

  • Tektronix 070-A830-51 - page 257

    Replaceable Mechanical Parts A WG710 Service Manual 10-15                Figure 10-6: CPU unit ...

  • Tektronix 070-A830-51 - page 258

    Replaceable Mechanical Parts 10-16 A WG710 Service Manual Replaceable Parts List (except option 02) Fig. & index number T ektronix part number Serial no. effective Serial no. discont'd Qty Name & description Mfr . code Mfr . part number 7-1 337-A21 1-00 1 SHIELD, ELEC:A TT , TOP 337-A21 1-00 ĂĂĂ-2 21 1-0751-00 2 SCREW ,MACHINE:M3X8M ...

  • Tektronix 070-A830-51 - page 259

    Replaceable Mechanical Parts A WG710 Service Manual 10-17 –                            Figure 10-7: Circuit boards(except option 02) ...

  • Tektronix 070-A830-51 - page 260

    Replaceable Mechanical Parts 10-18 A WG710 Service Manual Replaceable Parts List (for option 02) Fig. & index number T ektronix part number Serial no. effective Serial no. discont'd Qty Name & description Mfr . code Mfr . part number 8-1 129-A061-00 6 SP ACER, POST :10.0MM L, M3, INT/EXT THD, 5.5 MM HEX, BRS NI PL 129-A061-00 ĂĂĂ-2 ...

  • Tektronix 070-A830-51 - page 261

    Replaceable Mechanical Parts A WG710 Service Manual 10-19 –               Figure 10-8: Circuit boards (for option 02) ...

  • Tektronix 070-A830-51 - page 262

    Replaceable Mechanical Parts 10-20 A WG710 Service Manual Fig. & index number T ektronix part number Serial no. effective Serial no. discont'd Qty Name & description Mfr . code Mfr . part number Replaceable Parts List Fig. & index number T ektronix part number Serial no. effective Serial no. discont'd Qty Name & descriptio ...

  • Tektronix 070-A830-51 - page 263

    Replaceable Mechanical Parts A WG710 Service Manual 10-21                        Figure 10-9: Rear Panel ...

  • Tektronix 070-A830-51 - page 264

    Replaceable Mechanical Parts 10-22 A WG710 Service Manual Replaceable Parts List Fig. & index number T ektronix part number Serial no. effective Serial no. discont'd Qty Name & description Mfr . code Mfr . part number 10-1 390-A088-00 1 CABINET ASSY :AL 390-A088-00 ĂĂĂ-2 348-1314-00 122 CM GASKET ,SHIELD:FINGER TYPE,BE-CU,609.6MM L, ...

  • Tektronix 070-A830-51 - page 265

    Replaceable Mechanical Parts A WG710 Service Manual 10-23            Figure 10-10: Cabinet ...

  • Tektronix 070-A830-51 - page 266

    Replaceable Mechanical Parts 10-24 A WG710 Service Manual Replaceable Parts List Fig. & index number T ektronix part number Serial no. effective Serial no. discont'd Qty Name & description Mfr . code Mfr . part number 11 - 1 101-0142-01 1 TRIM,DECORA TIVE:FRONT ,RACK MOUNT 101-0142-01 ĂĂĂ-2 348-1569-00 1 14 CM SHILD GASKET , ELEC:ME ...

  • Tektronix 070-A830-51 - page 267

    Replaceable Mechanical Parts A WG710 Service Manual 10-25                Figure 10-1 1: Rack mount ...

Manufacturer Tektronix Category Welding System

Documents that we receive from a manufacturer of a Tektronix 070-A830-51 can be divided into several groups. They are, among others:
- Tektronix technical drawings
- 070-A830-51 manuals
- Tektronix product data sheets
- information booklets
- or energy labels Tektronix 070-A830-51
All of them are important, but the most important information from the point of view of use of the device are in the user manual Tektronix 070-A830-51.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Tektronix 070-A830-51, service manual, brief instructions and user manuals Tektronix 070-A830-51. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Tektronix 070-A830-51.

Similar manuals

A complete manual for the device Tektronix 070-A830-51, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Tektronix 070-A830-51 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Tektronix 070-A830-51.

A complete Tektronix manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Tektronix 070-A830-51 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Tektronix 070-A830-51, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Tektronix 070-A830-51, that we can find in the current document
3. Tips how to use the basic functions of the device Tektronix 070-A830-51 - which should help us in our first steps of using Tektronix 070-A830-51
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Tektronix 070-A830-51
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Tektronix 070-A830-51 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Tektronix 070-A830-51?

Use the form below

If you did not solve your problem by using a manual Tektronix 070-A830-51, ask a question using the form below. If a user had a similar problem with Tektronix 070-A830-51 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)