Manual Bryant 3163

29 pages 0.77 mb
Download

Go to site of 29

Summary
  • Bryant 3163 - page 1

    Service Manual Model 3163 Part No.: 6178 98A (94 -11) Contents Impor tant Safet y Information . . . . . . . . . . 1 Specifications . . . . . . . . . . . . . . . . . . 2 General Information . . . . . . . . . . . . . . 2 Dire ct Vent Re q uirements . . . . . . . . . . . 2 Pr opane S y st em . . . . . . . . . . . . . . . . 4 Description of Controls . ...

  • Bryant 3163 - page 2

    Important Safety Information Read this information before attemptin g to perform serv ic e on this refr i g erator. Pa g e 8 shows a wirin g pictorial and dia g r am. Review both the wirin g pictorial and di a g r am to understand the electric al circuits and the relationshi p to the individual components. Under stand the s ervice procedures before ...

  • Bryant 3163 - page 3

    Specifications Operati ng Limits AC Mode: 132 volts A C max. - 108 vol ts AC min. DC Mode: 15.4 volts DC max. - 11.5 vol ts DC min. Gas Mode: 11" W.C. max. - 10.5" W .C. min. 15.4 VDC max. - 10.5 VDC min. Curre nt Draws AC Heatin g Element - 1.3 amp @ 110 volts AC 1.4 amps @ 120 volts A C DC Heatin g Element - 11.7 amps @ 12 volts DC 13.6 ...

  • Bryant 3163 - page 4

    st ituti on will v oid the agencies’ certifications and the Norcol d warranty. Refer to this manual for proper in- structions . Ins tall the refriger ator and vents as dir ected by Norcold without modifi cation. The clearance from the refri g erator’s left side ( facin g the front of the refri g erator ) to the vehic le’s exterior wall is imp ...

  • Bryant 3163 - page 5

    Insulating the Flexi ble Exhaust Piping The flexible exhaust pipe must be i nsulated prior to installati on into the vent terminal housin g . The flexible ex haust pipe connects to the fl ue tube of the refri g era- to r’ s coo lin g unit and routes to the bottom openin g of the vent terminal housin g . Use the non-combusti ble insula tion materi ...

  • Bryant 3163 - page 6

    Ch eck Out of Fl ame Fail ure Saf ety Devi ce 1. To verif y operation of the flame failure safet y devic e, start the refri g erator in the g as mode ( re fer to li g htin g instructi ons on pa g e 6 ) and verif y the presence of a flame. 2. Turn off the g as at the manual shut-off valv e or at the main g as suppl y tank. 3. T he flame will g o out ...

  • Bryant 3163 - page 7

    Lighting and Start-Up Instructions The Li g htin g and Start-Up Instructions are located on the top portion of the interior door li ner. Refer to Fi g ur e 8 for location of the operatin g controls. Noti ce: W hen warm humid weather c onditions are ob- serv ed, operate the refrigerator on either AC or DC electric for a minimum of fi ve (5) minutes ...

  • Bryant 3163 - page 8

    Norcold Limited Warranty Time Allowance Char t Rialta To g ain access to the operatin g controls of the refri g - erator , remove the drawer directl y above the refri g era- tor. The interrupter can be replaced without removin g the refri g erator. EuroVan To g ain access to the operatin g controls of the refri g - erator , remove the control panel ...

  • Bryant 3163 - page 9

    Wiring Pictorial & Diagram 8 ...

  • Bryant 3163 - page 10

    Impo rtant Safety Information - AC Circuit Re ad th is in for matio n befo re a ttempt in g to perfo rm service o n this refri g er ator. Understa nd th e service procedu res bef ore performi n g the ser vice . • Us e ca ution w hen perfo rmin g the AC dia g nostic pro cedur es. Di scon nect th e AC e lectr ical power s our ce to th e refri g era ...

  • Bryant 3163 - page 11

    YES Is selector switch in the AC position? NO YES Refrigerat or Will Not Operate on AC Se t selector switch to AC and start refrigerator. Sp ecifica tions AC Vo lta g e: 108 - 132 VAC Current Draw: 1.3 - 1.4 amps Heater Resistance: 81.7 - 90.3 ohms Is AC voltage at input of selector switch? NO YES R eplace selector switch and start refrigerator. Is ...

  • Bryant 3163 - page 12

    Impo rtant Safety Information - DC Circuit Re ad th is in for matio n befo re a ttempt in g to perfo rm service o n this refri g er ator. Understa nd th e service procedu res bef ore performi n g the ser vice . • Use caution w hen pe rformi n g the DC dia g nost ic proc edures. Disc onnect the DC el ectrica l pow er sourc e to t he refri g erato ...

  • Bryant 3163 - page 13

    Sp ecifica tions DC Volta g e: 11.5 - 15.4 VDC Current Draw: 11.7 - 13.6 amps Heater Resistance: .95 - 1.05 ohms Refrigerator Will Not Operate on DC Electric Is selector switch set to DC? NO YES Se t selector switch to DC and start refrigerator. Is 12 VDC to i nput of 20 amp fuse? NO YES Is 12 VDC at output of fuse? NO R epl ace 20 am p fuse. Corre ...

  • Bryant 3163 - page 14

    Important Safety Informatio n - Gas Circuit Re ad th is in form ation befo re att empt in g to perfo rm service o n this refri g er ator. Understa nd th e service procedu res bef ore performi n g the ser vice . • Pro pane g as c an c ause a n ex plos ion. Us e caut ion wh en wor kin g with or nea r a pr opane g as s y stem . D o not s moke , cr e ...

  • Bryant 3163 - page 15

    YES No Spark at Burner Is 12 VDC at input of 1 amp fuse? NO YES Is 12 VDC at output of 1 amp fuse? NO R epl ace 1 amp fuse and start refrigerator. Corre ct DC source to 1 amp fuse. Is selector switch set to Gas? NO YES Se t selector switch to Gas and start refrigerator. Is 12 VDC at input of 20 AM P fu se? NO YES Corre ct DC source to 20 amp fuse. ...

  • Bryant 3163 - page 16

    Fi g ur e 9 Note : If flame is burning but t h e flame indicator l a mp is not illumi - nated, check for 2 V o l t s DC from the re- li ghter to the lamp. If 2 Volt s DC is present, repl ace flame indica- tor lamp. If 2 Volts DC is not present, replace the relighter. Fi g ur e 10 15 ...

  • Bryant 3163 - page 17

    Burner Ignites But F lame Will Not Hold Se t thermostat to maximum setting. Is gas pressure at pressure tap tee between 10.5 - 11" W.C.? NO R eplace thermostat. Is the DC volt- age at terminal bl ock between 10.5 - 15.4 VDC? NO YES Corre ct DC volt age input. 0 milli-volts on both terminals. R eplace thermocouple. Remove white wir es and jump ...

  • Bryant 3163 - page 18

    Important Safety Informatio n - DC Fan Circuit Re ad th is in form ation befo re att empt in g to perfo rm service o n this refri g er ator. Understa nd the service procedu res bef ore performi n g the ser vice . • Pro pane g as c an c ause a n ex plos ion. Us e caut ion wh en wor kin g with or nea r a pr opane g as s y stem . D o not s moke , cr ...

  • Bryant 3163 - page 19

    Co rrect 12 VDC source to mode selection switch. Is 12 VDC present at output of 1 amp fuse? NO YES R epl ace 1 amp fuse. Is 12 VDC present at input of 1 amp fuse? NO YES Co rrect 12 VDC source to fuse. Is the mode selection in the Gas position? NO YES Se t mode selection switch to gas. Co rrect 12 VDC source to fan thermostat. R epl ace mode select ...

  • Bryant 3163 - page 20

    Diagnosing Cooling Problems Read this information before attemptin g to perform serv ic e on this refr i g erator . Understand the service procedur es before performin g the service. Always apply the safety pr ecautions on page 1 and the precauti ons listed below. Fai lure to follow these safety precauti ons can res ult in substantial property dama ...

  • Bryant 3163 - page 21

    Refrigerator Removal Procedures Improper removal and installation of the refrigerator c an cause injury or property damage. Befor e attempt- i ng the procedures below, review the " Important Safety Information" on page 1 and the procedures below. EuroVa n Camper 1. Turn off the g as suppl y at the main tank. 2. Turn the refri g erator’s ...

  • Bryant 3163 - page 22

    Rialta 1. Turn off the g as suppl y at the main tank. 2. Turn the refri g erator’s mode selector to "OFF". 3. Remov e the refri g erator’s s y stem cover located on the left front of the refri g erator b y removin g 5 retainin g screws . 4. Remov e 5 retainin g screws securin g the refri g - erator to the enclosure. 5. Re move the dr ...

  • Bryant 3163 - page 23

    No. P art No. Description 1 617980 O-Rin g 2 617773 Washer 3 61761122 Scre w #8 - 15 x 1/2" S.S . 4 61633330 Screw #8 - 32 x 5/16" 5 617923 Vent Terminal Housin g 6 617924 Vent Terminal Gasket 7 617922 Back Plate 8 617921 Exhaust Disk 9 617920 Vent Cover 10 617985 Air Inlet Tube ( EuroVan ) 618007 Air Inlet Tube ( Rialta ) 11 618428 Air E ...

  • Bryant 3163 - page 24

    Final As sembly - 3163 23 ...

  • Bryant 3163 - page 25

    No. Part No. Description 1 617916 Informati on Packet 2 618014 Wire Conduit 3 618013 Wire Conduit 4 617989 Burner Tube 5 618073 DC Fan 6 618403 F an Support 7 618404 Fan Support Bracket 8 618093 Thermostat ( Fan ) 9 618021 Control Cover Assembl y 10 617961 Fl ue Baffle Wire 11 617960 Flue Baffle 12 61562622 DC Heater ( Yell ow Leads ) 13 61562522 A ...

  • Bryant 3163 - page 26

    No. P art No. Description 1 617913 Control Cover 2 617945 Mode Selection Swi tch 3 618040 Terminal Connector 4 61609022 Indicator Lamp 5 617981 Hole Plu g C ontrol C over Asse mbly - 3163 25 ...

  • Bryant 3163 - page 27

    No. P art No. Description 1 61445322 Plu g 2 61594422 Fittin g 3 617965 Safet y Valve 4 61750522 Interrupter 5 617976 Manual Shut-Off Valve 6 61749822 Gas Valve Mountin g Bracket 7 617952 Ther mostat Control Mountin g Bracket 8 61694622 U-Tube 9 61546822 Fittin g 10 617944 Ther mostat Control Control As sembly - 31 63 26 ...

  • Bryant 3163 - page 28

    No. P art No. Description 1 617995 Si g ht Glass 2 617933 Si g ht Glass Gr ommet 3 617927 Burner Support Bracket 4 617936 Burner Assembl y 5 61753137 Orific e Adapter Ass embl y 6 617983 Thermocouple 7 617997 Thermocoupl e Grommet 8 617966 Spar k Electrode 9 617996 Burner Grommet 10 617925 Burner Box Bottom Burner Box As sembly - 31 63 27 ...

  • Bryant 3163 - page 29

          ...

Manufacturer Bryant Category Refrigerator

Documents that we receive from a manufacturer of a Bryant 3163 can be divided into several groups. They are, among others:
- Bryant technical drawings
- 3163 manuals
- Bryant product data sheets
- information booklets
- or energy labels Bryant 3163
All of them are important, but the most important information from the point of view of use of the device are in the user manual Bryant 3163.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Bryant 3163, service manual, brief instructions and user manuals Bryant 3163. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Bryant 3163.

Similar manuals

A complete manual for the device Bryant 3163, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Bryant 3163 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Bryant 3163.

A complete Bryant manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Bryant 3163 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Bryant 3163, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Bryant 3163, that we can find in the current document
3. Tips how to use the basic functions of the device Bryant 3163 - which should help us in our first steps of using Bryant 3163
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Bryant 3163
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Bryant 3163 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Bryant 3163?

Use the form below

If you did not solve your problem by using a manual Bryant 3163, ask a question using the form below. If a user had a similar problem with Bryant 3163 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)