    PRODUCT OVERVIEW WHIRLWIND SERIES HURRICANE SERIES CYCLONE SERIES 1 Model number: AK2000, 2036 QuattroVent Air Curtain Dual “Thrust-Fore" Self Clean Blowers Digital Touch Pad Controls Clock, Timer, 3 stage Delay Shutoff. Model number: AK9 8 00 Dual Self Clean Blowers Independent Rocker Controls w/ High, Low speed Slim Line Design Overview 1. ...

  • Zephyr AK6000 - page 4

    CONTROLS HURRICANE SERIES 2 Controls Overview 1. Set Time 2. Digital Display 3. Set Hours 4. Set Minutes 5. Set Timed Delay Shut Off 6. Light On-Off 7. Left Blower: On-High-Low-Off 8. Right Blower: On-High-Low-Off 9. Operations: On-Off 10. Right Blower Low Speed Indicator 11. Right Blower High Speed Indicator 12. Left Blower Low Speed Indicator 13. ...

  • Zephyr AK6000 - page 5

    Blower Controls You can simultaneously turn On the light and both blowers on Hi speed by simply pressing "On/Off" once. During this time, you can select blowers and speed as indicated by pressing the "Fan-L" and "Fan-R" button. Note: The third press on the "Fan-L" and "Fan-R" button will turn blower ...

  • Zephyr AK6000 - page 6

    CONTROLS 4 Setting Timer (Alarm) Press " hr " and " min " button to set desired timer countdown. Once timer is set, countdown will start in 7 seconds as delay indicator light flashes. When countdown reaches 0, 10 short beeps will sound. To cancel timer after setting, press "On/Of f" button to terminate all operations a ...

  • Zephyr AK6000 - page 7

    MAINTENANCE 5 Self Clean Feature All Zephyr Range Hoods are filter-less and are designed with a self clean feature. The centrifugal blower system automatically liquefies grease accumulated in its internal housing. All systems are equipped with dishwasher safe grease containers for its self clean function. Grease and residue from cooking are often a ...

  • Zephyr AK6000 - page 8

    Hurricane Series: Remove light shield by turning counter- clockwise. Clean in dishwasher under normal wash cycle. Whirlwind Series: Remove light shield by unscrewing Philips screw. Clean in dishwasher under normal wash cycle. Cleaning Tip: Fill residue containers ¼ full with water before cleaning or during regular use. This will help to prevent gr ...

  • Zephyr AK6000 - page 9

    MAINTENANCE 7 QuattroVent Channels The QuattroVent Air-Curtain channels are adjoined to its two main blowers and share the same internal housing. No further cleaning is required after the self clean is completed. Clean residue around the channels surface with ‘409’ and a cotton cloth regularly. Replacing Lights All light bulbs included are 40W ...

  • Zephyr AK6000 - page 10

    INST ALLA TION 8 REQUIREMENTS ACCESSORIES WARNING Installation of this product is intended for qualified installers, service technicians, or persons with similar qualified background. DO NOT attempt to install this appliance yourself. Injury could result form installing the unit due to lack of appropriate electrical knowledge and technical backgrou ...

  • Zephyr AK6000 - page 11

    INST ALLA TION 9 MIN. 18” MAX 30” net width DUCT OPENING CLEARANCES Front Rear Front Rear Wall Minimum clearance above range should be no less than 18“ from the range surface to the range hood’s base. Maximum height are recommended not to exceed 30” for maximum efficiency. Net width on all models are call out width less 1/4”. Note: Refe ...

  • Zephyr AK6000 - page 12

    INST ALLA TION 10 STEP 1 STEP 3 STEP 5 STEP 2 STEP 4 STEP 6 (also refer notes on pg. 16) 1. Remove all contents from box 2. Unscrew and remove bottom grease splash shield 1. Locate electrical connection box knock out from left rear of hood and pry open with screwdriver 1. Cut out cabinet base opening if necessary. Refer cut out dimensions previous ...

  • Zephyr AK6000 - page 13

    INST ALLA TION 11 STEP 7 STEP 9 (also refer notes on pg. 16) STEP 11 STEP 8 STEP 10 STEP 12 (also refer notes pg. 16) 1. Lift hood to bottom of cabinet 1. Support hood to place, fasten both rear with screws and washers provided. 1. Fasten front of hood. Level all sides and adjust accordingly.** 1. Drill out cabinet base through electrical box with ...

  • Zephyr AK6000 - page 14

    INST ALLA TION 12 STEP 13 STEP 15 STEP 17 STEP 14 STEP 16 STEP 18 1. On Cyclone & Whirlwind models, be sure to pull both grease tubes over its opening. 1. Turn on electrical supply or plug into receptacles. 1. Reinstall electrical box cover. 1. Next, fasten the 3 front screws and begin tightening all screws from rear to front. 1. Connect duct t ...

  • Zephyr AK6000 - page 15

    INST ALLA TION 13 CONVERTIBLE OPTIONS 3-1/4 x 10“ Vertical Discharge 1. Remove pre-mounted 6“ transition adaptor on duct opening. Leave attached gasket in its original place. 3. Mount the 3-1/4 x 10“ starting collar on top of transition piece with remaining screws. 2. Place rectangular transition adaptor as shown over gasket and by first inst ...

  • Zephyr AK6000 - page 16

    INST ALLA TION 14 3-1/4 x 10“ Rear Discharge 4. At rear of range hood, remove all screws on pre- mounted rear rectangular cap and remove cap with gasket. 6. Remove 2 arch blocks through top opening. Option 1: (for recessed cabinet base) Re-install originally pre-mounted round transition piece at opening with gasket. 7. Mount Starting Collar (prov ...

  • Zephyr AK6000 - page 17

    INST ALLA TION 15 3-1/4 x 10“ Rear Discharge Option 2: (for flush cabinet base) Mount rectangular transition piece at opening with gasket as shown. Mount rectangular cap (previously removed) on top of transition adaptor. ...

  • Zephyr AK6000 - page 18

    INST ALLA TION 16 INSTALLA TION NOTES Step 6: A damper (not included) should be installed to prevent back-draft where needed. A damper might also be required local codes in order to qualify for building inspections. You can purchase dampers from most hardware stores, or call our service line to order. When a damper is not installed, a starting coll ...

  • Zephyr AK6000 - page 19

    TROUBLE SHOOTING 17 1. Upon completion of installation, nothing works. 2. Light is on but blowers are not turning at all or seems to be scraping on something. 3. When blowers are on, something seems to be loose and spinning around inside. 4. Vibration when blowers are on 5. Blowers noise 6. Light is not working 7. No grease is collected in the resi ...

  • Zephyr AK6000 - page 20

    TROUBLE SHOOTING 18 11. Cooking fumes and smoke dissipates before it reaches the blower. Use a damper type sidewall cap. Reduce the number of elbows and length of duct work. Check if all joints are properly connected, sealed and taped. Check if unit is installed at the recommended height (page 9). The range hood should also be able to cover the ent ...

  • Zephyr AK6000 - page 21

    www.zephyronline.com Warranty One Y ear Service Repair W arranty: F or one year from date of original purchase, we will provide free of c harge, service lab or to repair any failed parts or components due to manufacturing defects. T en Y ears Parts W arranty: F or ten years from date of original purchase, we will provide free of c harge, nonconsuma ...

Manufacturer Zephyr Category Fan

Documents that we receive from a manufacturer of a Zephyr AK6000 can be divided into several groups. They are, among others:
- Zephyr technical drawings
- AK6000 manuals
- Zephyr product data sheets
- information booklets
- or energy labels Zephyr AK6000
All of them are important, but the most important information from the point of view of use of the device are in the user manual Zephyr AK6000.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Zephyr AK6000, service manual, brief instructions and user manuals Zephyr AK6000. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Zephyr AK6000.

Similar manuals

A complete manual for the device Zephyr AK6000, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Zephyr AK6000 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Zephyr AK6000.

A complete Zephyr manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Zephyr AK6000 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Zephyr AK6000, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Zephyr AK6000, that we can find in the current document
3. Tips how to use the basic functions of the device Zephyr AK6000 - which should help us in our first steps of using Zephyr AK6000
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Zephyr AK6000