Summary
  • Omega Engineering DAQ-12 - page 1

    INTERFACE CARDS FOR PERSONAL COMPUTERS DAQ-12 Data Acquisition Adapter For 16 bit ISA compatible machines Users Manual OMEGA ENGINEERING, INC. TEL: (203) 359-1660 One Omega Drive FAX: (203) 359-7700 P.O. Box 4047 Toll free: 1-800-826-6342 Stamford, CT 06907-4047 E-mail: das@omega.com http://www.dasieee.com ...

  • Omega Engineering DAQ-12 - page 2

    WARRANTY/DISCLAIMER OMEGA ENGI NEERING, INC. , w arrants this unit to be free of def ects in materials and w orkmanship for a perio d of 13 mont hs from the date of purchase. OMEGA w arranty adds an ad ditional one (1) month grace period to the normal one (1 ) year pr oduct w arr anty to co ver shipping and handling time. This ensures that OMEGA’ ...

  • Omega Engineering DAQ-12 - page 3

    Declaration of Conf orm ity Manufacturer's Name: Omega Engineering, Inc. Manufacturer’s Address: One Omega Drive Stamford, CT 06907-0047 Application of Council Directive: 89/336/EEC Standards to which Conformity is Declared: * EN50081-2 (EN55022, EN60555-2, EN60555-3) * EN50082-1 (IEC 801-2, IEC 801-3, & IEC 801-4) Type of Equipment: Inf ...

  • Omega Engineering DAQ-12 - page 4

    OMEGAnet  On-line Service: Internet e-mail: http://www.omega.com info@omega.com Servicing North America : USA : One Omega Drive, Box 4047 E-mail: info@omega.com ISO 9001 Certified Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 Canada : 976 Bergar E-mail: info@omega.com Laval (Quebec) H7L 5A1 Tel: (514) 856-6928 FAX: (514) 856-68 ...

  • Omega Engineering DAQ-12 - page 5

    United Kingdom : One Omega Drive, River Bend Technology Drive ISO 9002 Certified Northbank, Irlam, Manchester M44 5EX, England Tel: 44 (161) 777-6611 FAX: 44 (161) 777-6622 Toll Free in England: 0800-488-488 E-mail: info@omega.co.uk It is the policy of OM EGA to comply with al l worl dwide safety and EM C/EMI regulations that apply. OMEGA is consta ...

  • Omega Engineering DAQ-12 - page 6

    Table of Contents 29 4.2 Programming the 8254 Counter/Timer ............................ 28 4.1.9 8254 Control Word/Status Register ................................... 28 4.1.8 Multi-Function Timer Register ....................................... 28 4.1.7 Clock Rate Register (high word) ..................................... 28 4.1.6 Clock Rate Regi ...

  • Omega Engineering DAQ-12 - page 7

    List of Figures and Tables 25 Table 4-1. DAQ-12 Address Map ............................................... 15 Table 2-3. D/A Converter Mode Selection Options ................................ 14 Table 2-2. A/D Conversion Format Examples .................................... 12 Table 2-1. Recommended Input Ranges and Gain Settings ................... ...

  • Omega Engineering DAQ-12 - page 8

    1. Introduction The DA Q-1 2 is a high s peed dat a ac quisit ion adap ter for IBM AT a nd comp atible m ach ines off eri ng ei ght d if fer ential anal og i nput channel s with 16- bit r esol ution, two anal og output channel s with 12-b it r esoluti on and four di gi tal i nput/output lines. Other f eature s of the DAQ-12 include: Analog to Digit ...

  • Omega Engineering DAQ-12 - page 9

    1.2 DAQ-12 Specifications DACK 5, 6 , 7 DRQ 5, 6 , 7 DMA Levels: IRQ 2, 3, 4. 5, 6, 7, 10, 11, 12, 14, 15 Interrupt Levels: 0000H - FFFFH I/O Address Range: ISA 16-bit Bus Interface: 491.4mA 374.9 mA +12 volts --- --- -12 volts 1204.9mA 1069.0 mA +5 volts --- --- -5 volts I(ms) I(t) Power Supply Power Requirements: I(t) = Typical Current / I(ms) = ...

  • Omega Engineering DAQ-12 - page 10

    2. Circuit Board Description and Configuration The ba se addres s of t he DA Q-1 2 is sele ct ed using s witch es SW1 and SW 2. The op erat ing mo de of t he DAQ-12 is co nt rolled by jump ers J1 th rough J7 , while DMA an d interru pt sele ctions ar e set with jumpe rs J8 through J 11. Connections to exter nal e quipmen t are ma de through the hig ...

  • Omega Engineering DAQ-12 - page 11

    The a mpli fi er stag e of the A/D conver ter circui t perf orms tw o functi ons: (1) a mpli fi es low leve l input signa ls and (2) c onv ert s this in put s ignal int o a vo lta ge ran ge acc ept able to the A/D c onve rter. Sev en ga in levels a re so ftware selec table for the a mplifie r st age of th e A/D circu it. To su ppo rt high lev el in ...

  • Omega Engineering DAQ-12 - page 12

    Table 2-1 deta ils the availa ble gain s ettin gs a nd resultin g inpu t range s for t he vario us input conf ig urations. Note that the 'gai n byte' f ie ld i n Tabl e 2- 1 is the va lue wri tten to the DAQ-12's gain control register. (* indicates unipolar mode not available with gain of ½ ). 83 2-3 4 +2.5/ ±1.25 82 2-3 2 +5/ ±2. ...

  • Omega Engineering DAQ-12 - page 13

    The final stage of the A/D converter circuit is the A/D converter IC . The co nverter must be co nfigur ed for unipo lar or bipo lar input vo ltages a s sho wn in Figu re 2-3. Whe n co nfigured for uni pola r ope ration, the anal og input mul tipl ied by the gai n setti ng must b e in the r ange of 0 volts (analog ground) to +10 volts. When configu ...

  • Omega Engineering DAQ-12 - page 14

    n/a 0000 1111 1111 1111 10 0000 0111 1111 1111 0000 1000 0000 0000 5 0000 0100 0000 0000 0000 0100 0000 0000 2.5 0000 0000 0000 0000 0000 0000 0000 0000 0 1111 1100 0000 0000 n/a -2.5 1111 1000 0000 0000 n/a -5 Code Code Bipolar Unipolar Voltage Table 2-2. A/D Conversion Format Examples NOTE: The ' vo lta ge' c olumn is the vo ltage a ppl ...

  • Omega Engineering DAQ-12 - page 15

    The D /A converte r channel s may al so be operated i n unipolar mode: 0 to +5 volts, or b ipol ar mo de: -5 to +5 vo lts. The ou tput m ode is selec ted us ing jump er J5 as sh own in Figu re 2-5. In addit ion , a gain sele ction jumpe r is pro vided t o sele ct an outp ut gain of 1 or 2 . When u sing an exte rnal voltag e ref erence , thi s gai n ...

  • Omega Engineering DAQ-12 - page 16

    2.3 Digital Input/Output The DAQ- 12 of fer s four b its of di gi tal output and four b its of di gi tal i nput f or co ntrol/ mon ito ring o f extern al digit al dev i ce s. The four digital ou tput lines a re LS TTL co mpat ible an d will init ialize low (0 vo lts) on power-u p. The four digit al inp ut s are als o LS TTL co mpat ible. There is n ...

  • Omega Engineering DAQ-12 - page 17

    2.5 Clock Selection The D AQ-1 2 is e quipped wi th a progr ammab le cl ock ci rcui t to pr oduce d ata sampl in g rate s independ ent from the clock rate o f the host co mputer. An onboard 8254 programmabl e inte rval time r, wi th a 10 MHz clock input and ei ther tw o or thr ee cascad ed 16-b i t timer s, provi des the sa mpli ng rate. Thi s enab ...

  • Omega Engineering DAQ-12 - page 18

    2.5.1 Internal Clock Sampling rates for the internal clock can be calculated using the following equation: t = 100ns * [N1*N2] or f = 10MHz / [N1*N2] wher e N1 is the low 1 6-b its of the clock di vid er and N2 is the high 1 6-b its of the clock divider. The following criteria must be met when selecting values for N1 and N2: 2 < N1 < 65,535 2 ...

  • Omega Engineering DAQ-12 - page 19

    Whe n co nfigured fo r a 48-bit div ider, the first s ampling p eriod will be slightly lo nger th an the other s because the fi rst cl ock per iod is r equi red to l oad the i ni tial val ue of the multi-function timer. The following equation calculates the additional time of the first period: t = 100ns * [N1 * N2] add To m inimiz e the a moun t of ...

  • Omega Engineering DAQ-12 - page 20

    When the mul ti- functi on time r is use d as a pr e-d i vid er, the fr equency of the ex ternal cl ock input may be var ied fr om DC to 10 MHz as l ong as the hi gh porti on of the cl ock is at l east 30ns and the low porti on is at least 5 0ns. E xcept f or the fi rst peri od, the sampl in g rate of the DAQ-1 2 will be the e xte rnal clock fre qu ...

  • Omega Engineering DAQ-12 - page 21

    2.7 Direct Memory Access Di rect Me mory Acce ss (D MA) tra nsfe rs provi de a way of transf er ri ng da ta fr om the DAQ- 12's A/D conver ter into the persona l computer 's memory wi thout using the Central Pro cessin g Unit (C PU). DMA c apability e nables oth er syst em so ftware to be execu ted while data is being input from the DAQ-1 ...

  • Omega Engineering DAQ-12 - page 22

    2.8 Interrupts The DAQ-12 is capable of generating an interrupt from one of four sources: 1. End of conversion signal 2. DMA terminal count 3. Multi-function timer output 4. External interrupt input The i nterrupt source is softwar e selected through the D AQ-12 contr ol word r egi ster. The interrupt level is selected using the jumpers J10 and J11 ...

  • Omega Engineering DAQ-12 - page 23

    3. External Connections The DAQ-12 is equipped with a high density 62-pin connector as shown in Figure 3-1. 2 - CH1+ 4 - CH2- (CH10+) 6 - CH 4+ 8 - CH5- (CH13 +) 10 - CH7+ 12 - AOUT0 14 - DOUT0 6 - DOUT3 18 - EXT TRIG 20 - DIN1 22 - CH0+ 24 - CH1- (CH9+) 26 - CH3+ 28 - CH4- (CH12+) 30 - CH6+ 32 - CH7- (CH15+) 34 - AOUT1 36 - DOUT1 38 - EXT INT 40 - ...

  • Omega Engineering DAQ-12 - page 24

    CHx-, C Hx+ : Ana l o g inpu ts t o t he ana l o g to digital co nvert er. When us ing different ial input mo de, eight input ch annels are a vailable (C H0+ to C H7+). When usin g s ingle-en ded inputs, 16 channels are avai labl e (CH0+ t o CH15+). The first eight channels are input through the connections mark ed C H 0+ to CH7+ and the second ei ...

  • Omega Engineering DAQ-12 - page 25

    4. Register Description and Programming The DAQ-12 uses 16 con secut ive I/O address locat ions in the range 0 to FFFFH. The c ard ut ilizes thes e addre ss es fo r the regist ers list ed in Table 4-1 . (* indicat es regis ters loca te d in 8254 counter). Read/Write 8-bit 8254 Control Word/Status Register Base F * Read/Write 8-bit Multi-function Ti ...

  • Omega Engineering DAQ-12 - page 26

    INT2, INT1 and INT0 control the DAQ-12 interrupt source. INT2 INT1 INT0 DESCRIPTION 0 0 0 Interrupt disabled 1 0 0 Interrupt timer 2 1 0 1 Interrupt on terminal count 1 1 0 External interrupt 1 1 1 Interrupt on end of conversion DMAEN - enables / disables DMA. When set, logic 1, DMA transfers are enabled. DMAC T - e nable s t he m ulti-c hanne l DM ...

  • Omega Engineering DAQ-12 - page 27

    VALID - when s et, lo gic 1 , indic ate s at le ast one da ta sam ple was los t becau se it wa s rea d by the personal computer befor e the nex t sample was conver ted. Data was l ost because the sampli ng rate w as too fa st f or the computer to acq uir e the d ata. VALI D is rese t by w ri ting to the start conversion register. CHSL 2, CHSL 1, CH ...

  • Omega Engineering DAQ-12 - page 28

    4.1.4 D/A Converter 0 Register An output to this re giste r cause s the lower twel ve b its of data to be conve rted to an analog output on D/A conver ter channe l 0. The f our most sig nif ica nt bi ts of d ata are i gnor ed. Thi s register is 16-bit write only. 4.1.5 D/A Converter 1 Register An output to this re giste r cause s the lower twel ve ...

  • Omega Engineering DAQ-12 - page 29

    4.2 Programming the 8254 Counter/Timer This section provides programmi ng information for the 8254 count er/timer as implemented on the DAQ-12. For more details on the 8254, consult the Intel Micro-processor and Peripheral Handbook. To program any of the counters contained in the 8254 counter/timer, three steps are required: 1. Write the configurat ...

  • Omega Engineering DAQ-12 - page 30

    Counter 1 - Clock rate register (high word) operating mode: 2 minimum count value: 2 configuration byte: 0 / 1 / 1 / 1 / 0 / 1 / 0 / 0 = 74H Example: Program the value 13A4H into the high word of the clock rate register. output 74H to base_address + 0FH output A4H to base_address + 0DH output 13H to base_address + 0DH Example: Program the value FFF ...

  • Omega Engineering DAQ-12 - page 31

    DAQ-12 Users Manual Version 2.20 January 28, 1999 Part No. 940-0030-220 ...

Manufacturer Omega Engineering Category Network Card

Documents that we receive from a manufacturer of a Omega Engineering DAQ-12 can be divided into several groups. They are, among others:
- Omega Engineering technical drawings
- DAQ-12 manuals
- Omega Engineering product data sheets
- information booklets
- or energy labels Omega Engineering DAQ-12
All of them are important, but the most important information from the point of view of use of the device are in the user manual Omega Engineering DAQ-12.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Omega Engineering DAQ-12, service manual, brief instructions and user manuals Omega Engineering DAQ-12. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Omega Engineering DAQ-12.

A complete manual for the device Omega Engineering DAQ-12, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Omega Engineering DAQ-12 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Omega Engineering DAQ-12.

A complete Omega Engineering manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Omega Engineering DAQ-12 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Omega Engineering DAQ-12, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Omega Engineering DAQ-12, that we can find in the current document
3. Tips how to use the basic functions of the device Omega Engineering DAQ-12 - which should help us in our first steps of using Omega Engineering DAQ-12
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Omega Engineering DAQ-12
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Omega Engineering DAQ-12 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Omega Engineering DAQ-12?

Use the form below

If you did not solve your problem by using a manual Omega Engineering DAQ-12, ask a question using the form below. If a user had a similar problem with Omega Engineering DAQ-12 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)