Manual Intel 05-1850-004

26 pages 0.3 mb
Download

Go to site of 26

Summary
  • Intel 05-1850-004 - page 1

    O A&M API f or Lin ux Operating Systems Pr ogramming Guide A ugust 2005 05-1850-00 4 ...

  • Intel 05-1850-004 - page 2

    OA&M API for Linux Programming Guide – August 2005 INFORMA TION IN THIS DO CUMENT IS PRO VIDED IN CONNECTION WITH INTEL® PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED , BY EST OPPEL OR OTHER WISE, TO ANY INTELLECTU AL PROPER TY RIGHTS IS GRANTED BY THIS DOCUMENT . EXCEPT AS PRO VIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, ...

  • Intel 05-1850-004 - page 3

    OA&M API for Linu x Programming Guide – August 2005 3 Contents Revision H istory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 About This Publication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 ...

  • Intel 05-1850-004 - page 4

    4 OA&M API for Linux Programming Guide – August 2005 Contents Figures 1 OA&M API Clas ses . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 2 Event Notifi cation Framew ork . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Intel 05-1850-004 - page 5

    OA&M API for Linu x Programming Guide — August 2005 5 Re vision Histor y This re vision history summarizes the changes made in each published vers ion of this document. Document No. Publication Date Description of Revisions 05-1850-004 A u gust 2005 General Guidelines section : Added information a bout freeing memor y that is allocated for ob ...

  • Intel 05-1850-004 - page 6

    6 OA&M API for Linux Progra mming Guide — August 2005 Revisi on History ...

  • Intel 05-1850-004 - page 7

    OA&M API for Linu x Programming Guide — August 2005 7 About This Pub lication The following topics provide information about this publicati on: • Purpose • Intended Audience • How to Use This Publication • Related Information Purpose This publication provides guid elines for building applications using the Operatio ns, Administration ...

  • Intel 05-1850-004 - page 8

    8 OA&M API for Linux Progra mming Guide — August 2005 About This Public ation The information in this guide is or ganized as follo ws: • Chapter 1, “Produ ct Description” provides an o vervie w of the O A&M A PI. • Chapter 2, “Event Handling” describes how to register with the O A&M event notification frame work and handle ...

  • Intel 05-1850-004 - page 9

    OA&M API for Linu x Programming Guide — August 2005 9 1 1 . Pr oduct Description This chapter describes the O A &M API. The following topi cs are included: • O A&M API Overvie w . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 • Features . . . . . . . . . . . . . . . . . . . . . ...

  • Intel 05-1850-004 - page 10

    10 OA&M API for Linux Progra mming Guide — August 2005 Produc t Description Figure 1. O A&M API Classes 1.2 Features The features av ai lable through the OA&M API include the following: • Get version information (major release number , release build number , service pack number, feature pack number , service update number , feature ...

  • Intel 05-1850-004 - page 11

    OA&M API for Linu x Programming Guide — August 2005 11 Pr oduct Descriptio n for Linux Operating Systems Library Refer ence for informatio n about the CTPLA TFORMVERSIONINFO data structure and the ICTNode::GetSystemRe leaseVersionInfo( ) function. • Get physical identification information (serial number, PCI slot number , number of network ...

  • Intel 05-1850-004 - page 12

    12 OA&M API for Linux Progra mming Guide — August 2005 Produc t Description Figure 2. Event Notification Frame work Intel ® Dialogic system software components, such as de vice driv ers and firmware, are the supplier objects. They generate e vents that are broadcas t to consumer objects via the e vent notif ication channels. The DlgAdminCons ...

  • Intel 05-1850-004 - page 13

    OA&M API for Linu x Programming Guide — August 2005 13 Pr oduct Descriptio n The framew ork cont ains the following e vent notif ication channels, each of which carries specific types of e vents: • ADMIN_CHANNEL • CLOCK_EVENT_CHANNEL • F A UL T_CHANNEL • NETWORK_ALARM_CHANNEL Notes: 1. DM3 architecture boards generate e vents on al l ...

  • Intel 05-1850-004 - page 14

    14 OA&M API for Linux Progra mming Guide — August 2005 Produc t Description ...

  • Intel 05-1850-004 - page 15

    OA&M API for Linu x Programming Guide — August 2005 15 2 2 . Event Handling This chapter provides informat ion about receiving and handling asynchronous ev ents that are transmitted via the event notif i cation framew o rk. For your application to receive e vents from the ev ent no tification frame work you must follow these steps: 1. Define ...

  • Intel 05-1850-004 - page 16

    16 OA&M API for Linux Progra mming Guide — August 2005 Event Handling ...

  • Intel 05-1850-004 - page 17

    OA&M API for Linu x Programming Guide — August 2005 17 3 3 . Err or Handling This chapter describes the error handling capabilities provided b y the O A&M API. When an error occurs during ex ecution of a function in one of the System Component classes (CCTDomain, ICTN ode, ICTBoard or ICTCl ockAgent) , an exception is thro wn. Exceptions ...

  • Intel 05-1850-004 - page 18

    18 OA&M API for Linux Progra mming Guide — August 2005 Error Handling ...

  • Intel 05-1850-004 - page 19

    OA&M API for Linu x Programming Guide — August 2005 19 4 4 . Application De velopment Guidelines This chapter provides informatio n about developing applications using the O A&M API. It includes the following sections: • General Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Intel 05-1850-004 - page 20

    20 OA&M API for Linux Progra mming Guide — August 2005 Application Development Gu idelines • ICTClockAgent::SetTDMBusConfiguration( ) 4.2 Designing CT Bus Cloc king Applications If you are using an y of ICTC lockAgent class me mber functions (for example, to dev elop a customized system clo cking daemon) you must disa ble the clocking daemo ...

  • Intel 05-1850-004 - page 21

    OA&M API for Linu x Programming Guide — August 2005 21 Application Development Guide lines 6. When the stopbrd utility successfully stops the board, use the removebrd ut ility to notify the system that the board is being removed. 7. Physically remo ve the board from the chass i s when the board’ s Out of Service (Blue) LED lights. 8. Insert ...

  • Intel 05-1850-004 - page 22

    22 OA&M API for Linux Progra mming Guide — August 2005 Application Development Gu idelines ...

  • Intel 05-1850-004 - page 23

    OA&M API for Linu x Programming Guide — August 2005 23 5 5 . Building Applications This chapter provides general information for building applications that use the O A&M librar y . The follo wing topics are in cluded in this chapter: • Compiling and Linking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Intel 05-1850-004 - page 24

    24 OA&M API for Linux Progra mming Guide — August 2005 Building Applications dlgeventproxydef.h defines the generic data structure for O A&M ev ents Note: User-def ined header files that pro v ide an implemen tation of the CEventHandlerAdaptor class (i.e., adminhandler.h) and override its CEventHandlerAdap tor::HandleEvent ( ) function al ...

  • Intel 05-1850-004 - page 25

    OA&M API for Linu x Programming Guide — August 2005 25 Inde x A array of filters 15 C CCTDasiException 9 , 17 CEventHandlerAdaptor 12 , 15 class heirarchy 11 , 19 client data 15 CT Bus 8 D dasi.h 23 devices virtual 20 DlgAdminConsumer 12 dlgadminconsumer.h 23 dlgadminevents.h 23 dlgadminmsg.h 23 dlgcclockinge vents.h 23 dlgcnetworkalarmevents ...

  • Intel 05-1850-004 - page 26

    26 OA&M API for Linux Progra mming Guide — August 2005 ...

Manufacturer Intel Category Sleep Apnea Machine

Documents that we receive from a manufacturer of a Intel 05-1850-004 can be divided into several groups. They are, among others:
- Intel technical drawings
- 05-1850-004 manuals
- Intel product data sheets
- information booklets
- or energy labels Intel 05-1850-004
All of them are important, but the most important information from the point of view of use of the device are in the user manual Intel 05-1850-004.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Intel 05-1850-004, service manual, brief instructions and user manuals Intel 05-1850-004. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Intel 05-1850-004.

Similar manuals

A complete manual for the device Intel 05-1850-004, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Intel 05-1850-004 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Intel 05-1850-004.

A complete Intel manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Intel 05-1850-004 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Intel 05-1850-004, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Intel 05-1850-004, that we can find in the current document
3. Tips how to use the basic functions of the device Intel 05-1850-004 - which should help us in our first steps of using Intel 05-1850-004
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Intel 05-1850-004
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Intel 05-1850-004 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Intel 05-1850-004?

Use the form below

If you did not solve your problem by using a manual Intel 05-1850-004, ask a question using the form below. If a user had a similar problem with Intel 05-1850-004 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)