Manual Universal 150-FASNG

10 pages 0.34 mb
Download

Go to site of 10

Summary
  • Universal 150-FASNG - page 1

    ST OP QUESTIONS? MISSING / D AMAGED P ARTS Please do not return this product to the store. If a part is damaged or missing, simply e-mail us at php@allpro-heaters.com, or visit our website at http://allpro-heaters.com, or call our Customer Service Department at (888) 619-7060. We will be happy to assist you! Y ou can register your heater on line at ...

  • Universal 150-FASNG - page 2

    Page -2- GENERAL HAZARD WARNING: FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING, AND/OR ELECTRICAL SHOCK. ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTION ...

  • Universal 150-FASNG - page 3

    Page -3- OPERA TING PRECAUTIONS This is a natural gas, direct-fired, forced air heater. It's intended use is primarily temporary heating of buildings under construction, alteration or repair. This heater was designed and certified for use as a construction heater in accordance with ANSI Standard Z83.7/ CGA 2.14-2000. Check with your local fire ...

  • Universal 150-FASNG - page 4

    Page -4- ODOR F ADE W ARNING FUEL GAS ODOR LP gas and natural gas have man-made odorants added specifically for detection of fuel gas leaks. If a gas leak occurs you should be able to smell the fuel gas. Since Propane (LP) is heavier than air you should smell for the gas odor low to the floor. ANY GAS ODOR IS YOUR SIGNAL TO GO INTO IMMEDIATE ACTION ...

  • Universal 150-FASNG - page 5

    Page -5- OPERA TING INSTRUCTIONS PREPARING FOR OPERATION 1. Check the heater for possible shipping damage. If any is found, immediately notify the factory. 2. Follow all of the "Precautions". 3. Install plumbing to a low pressure (1/2 psig maximum) source of natural gas, using a minumum 3/4" ID hose or flexible connector not over 10 ...

  • Universal 150-FASNG - page 6

    Page -6- Item Part No. Description Qty. 150-F ASNG P ARTS Item Part No. Description Qty. 1 1700 Burner Shell Ass'y 1 2 6225 Snap Bushing, 5/8" 1 3 1672 Middle Cylinder 1 4 1146 Flame Holder Ass'y 1 5 1083 Spark Plug 1 6 1216 Orifice Ass'y 1 7 1741 Control Box Ass'y 1 8 1550 High Limit Switch 1 9 6170 Toggle Switch 1 10 7094 ...

  • Universal 150-FASNG - page 7

    WIRING CHART PART NO . COLOR LENGTH FROM T O 1100 White 7" Valve Terminal Block 1040 Black 6" On/Off Switch Terminal Block 1226 Red (Hi-Temp) 1 6 1/2" High Limit Switch Valve 1226 Red (Hi-Temp) 1 6 1/2" High Limit Switch Terminal Block 1070 Orange 11 " Flame Control (Ignition) Spark Plug 1959 Green 7 " Flame Control (H ...

  • Universal 150-FASNG - page 8

    Page -8- W ARRANTY We are pleased that you have selected our product and take this opportunity to assure you that qualified service facilities are available if required. With the cooperation of independent dealers, a nationwide network of authorized servicing dealers is available for your servicing requirements. Should your product require servicin ...

  • Universal 150-FASNG - page 9

    Warranty Registration First Na me Hand print only. Use blac k or blue ink pen to fill in this fo rm. Cross or chec k inside the cir cle. Your I nfo rma ti on Last nam e Postal code State City Maili ng Ad dress E-mai l Ad dre ss Product Information State Date of Purchase ( MM/DD/YY) Stor e Na me City Cost of Heat er ($) - / / Annual house h old inco ...

  • Universal 150-FASNG - page 10

    V isit our website for product information, technical support, customer service, and warranty registration at: WWW .ALLPRO-HEA TERS.COM for All-Pro products or WWW .UNVERISAL-HEA TERS.COM for Universal products. SCHEU PRODUCTS COMP ANY , INC A TTN: MARKETING DEP AR TMENT 8855 BAKER A VENUE RANCHO CUCAMONGA, CA 91730 ...

Manufacturer Universal Category Gas Heater

Documents that we receive from a manufacturer of a Universal 150-FASNG can be divided into several groups. They are, among others:
- Universal technical drawings
- 150-FASNG manuals
- Universal product data sheets
- information booklets
- or energy labels Universal 150-FASNG
All of them are important, but the most important information from the point of view of use of the device are in the user manual Universal 150-FASNG.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Universal 150-FASNG, service manual, brief instructions and user manuals Universal 150-FASNG. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Universal 150-FASNG.

Similar manuals

A complete manual for the device Universal 150-FASNG, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Universal 150-FASNG by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Universal 150-FASNG.

A complete Universal manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Universal 150-FASNG - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Universal 150-FASNG, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Universal 150-FASNG, that we can find in the current document
3. Tips how to use the basic functions of the device Universal 150-FASNG - which should help us in our first steps of using Universal 150-FASNG
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Universal 150-FASNG
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Universal 150-FASNG in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Universal 150-FASNG?

Use the form below

If you did not solve your problem by using a manual Universal 150-FASNG, ask a question using the form below. If a user had a similar problem with Universal 150-FASNG it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)