    I N S T A L L A T I O N A N D OWNER’S MANUA L As of date of manufacture, meets all ANSI/UL 325 Safety Requirements for V e h i c u l a r d o o r o p e r a t o r s . AUJ-S & AUH-S AU SERIES WITH SOLI D S T A TE CONTROL CIRCUITR Y JACKSHAFT COMMERCIAL VEHICULAR DOOR OP ERA T ORS R E A D T H I S M A N U A L C A R E F U L L Y B E F O R E I N S T ...

  • Linear AUH-S - page 2

    REA D THESE STA TEMENTS CAREFUL LY AND FOLLOW T HE INSTRUCT IONS CLOSELY. The Warning and Caution boxes throughout this manual are there to protect you and your equipment. Pay close attention to these boxes as you follow the ma nual. WARNING Indicates a MEC HANICAL hazard of INJUR Y OR DEATH. Gives instruc tions to avoid the hazard. CAUTION Indicat ...

  • Linear AUH-S - page 3

    The purpose of t his booklet is to pr ovide assembly, installation and operation information con cerning Model AUJ -S & AUH-S Commercial Vehicular Garage Do or Operators and relate d Accessory Products. NOTICE IT IS IMPORTANT THAT THIS INST RUCTION MANUAL BE READ AND UNDERSTOOD COM PLETELY BEFORE INSTALLATION OR OPERATION IS ATT EMPTED. IT IS I ...

  • Linear AUH-S - page 4

    Before starting the installatio n of the operator , the door must be in good working condition and p roper ly counterbalanced. Inspec t the door and trac k for loose or missing hardware. T est the door manually for balance and ea se of oper ation. Lubricate door hinges and rollers. If necessary, e mploy a qualified tech nician to adj ust the spring ...

  • Linear AUH-S - page 5

    ITEM # PART# DESCRIPTION QUAN. 1 Operator Power Head 1 2 005 031 3 Button St ation 1 3 30 Tooth Sprocke t, 1” Bore, 1/4 Key 1 4 20 Tooth Sprocke t, 1” Bore, 1/4 key 1 5 105193 Release/Hand Ch ain Wall Brack et 1 —— AR - As Required ITEM # PART# DESCRIPTION QUAN 6 100413 1/4 ” Square Key 2 7 006 119 5/16-18 x 1 Square Head Set Screw 4 8 10 ...

  • Linear AUH-S - page 6

    F igure 4, page 8 illu strates several positions suitable for mounting the operator ; right hand or left hand, either wall mo unt or ceiling mount and ce nter mount with direct co upling to the torsion shaft. Direct coupli ng may also be used in a side mount installation. Operators inte nded for d irect coupling require an internal speed modificati ...

  • Linear AUH-S - page 7

    DIRECT COUPLING MOUNTING F igure 4, page 8 illu strates several positions suitable for mounting the operator including center mount with direct coupling to the torsion sha ft. Direct couplin g may also be used in a side mount installation. Oper ators intended for direct coupling require a n internal speed modification and must be ordered from the f ...

  • Linear AUH-S - page 8

    Figure 4 100719 Right Side Mount Ceiling Mount Left Side Mount Ceiling Mount Center Mount Direct Couple W all Mount W all Mount 8 FIGURE 4 - OPE R A TOR MOUNT ING POSITIONS ...

  • Linear AUH-S - page 9

    107173 Figure 5 NOTE: Dim ensions for Model AUJ -S are s imilar to above, Model AUJ-S is not provide d with a chain hoist. 9 FIGURE 5 - OPE RA TOR DIMENSIONS - MODEL AUH-S 7.75 ...

  • Linear AUH-S - page 10

    10 FIGURE 6 - OPE R A TOR DIMENS IONS - MO DEL AUJ-S 107173 Figure 6 NOTE: Dim ensions for Model AUH -S are s imilar to ab ove, Model AUH-S is pro vided with a chain hoist. 15 7.75 ...

  • Linear AUH-S - page 11

    4) Depress the limit nut retaining Plate (D) so it disengages from t he slots in the limit n uts. Turn the OPEN li mit n ut (E) on the shaft until it engages the Open Limit Switch (A). You will need to liste n for an audible click. Release the retaini ng plate and be sure that it engage s in slots of bo th limit nuts. 5) Manually lower the door to ...

  • Linear AUH-S - page 12

    RISK OF ENT R APMENT THAT MAY RESULT IN SERIOUS PERS ONAL INJUR Y OR DEATH. DISC O NNECT PO WER TO THE OPENER BE FORE AND DUR ING INSTA LLATION OF AN ACCESSORY REVERS ING DOOR EDGE OR PHOTOELE CTRIC DEVICE. DO NOT RECONNE CT POWER T O OPENER U NT IL IN ST R U CT ED T O DO S O. EN SU RE D O OR WA Y IS C LEA R BE FO RE S TA R T ING T ES T IN G OF W A ...

  • Linear AUH-S - page 13

    9. See Figure 9 for connecting the photoelectric device to the operator. See P age 17 for proper setting of the selector switches. These switches must be proper ly set and an approved p hotoelectric device or approved doo r edge device connected to the oper ator to o btain B2 Mod e of Operation, Momentary Contact to C lose. DOOR EDGE an d PHOTOELEC ...

  • Linear AUH-S - page 14

    MOTOR CONTROL BOARD Figure 9 OPEN TB1 STOP CLOSE OPEN COM CLOSE STOP NO REV NC REV PHOTO COM SINGLE ILOCK 24 VAC COM SAFE FINISH PHOTOBE AM 3-WIRE PHOTOBEAM Door Edge and Photoelectric Wiring INST ALLA TI ON INSTRUCTI ONS 14 After properly connecting a n appro ved Entrapment Protection Device (see above and Page 3 ) to the operator, see Page 17 for ...

  • Linear AUH-S - page 15

    15 NOTE: It is now necessary to turn on the pow er in order to change the Operating Mo de (if applicable), progra m any changes des ired to the operator’s ot her settings, c heck for pr oper performance of all th e operator’s feature s to include the brake (if applicab le) and clutc h (adjusting settings if necessary); and to set and finalize a ...

  • Linear AUH-S - page 16

    Understand all of the operating features of your door contr ol system at the time of its installation. Your installing dealer will demonstr ate them for you. NEVER let children operate or play with door controls. Keep the Remote Control (where provided) away from children. Personnel should keep away from a door in motion and keep the moving door in ...

  • Linear AUH-S - page 17

    Changing the Sw itch Selectable Opera tion Modes The following modes are selected b y setting the on -board dip switches, Figure 20 at right sho ws where the switches are located on the oper ator control boar d. For each Operational Mode, the switches are set to either ON or OFF ac cording to the table at right belo w. For all the modes, if an appr ...

  • Linear AUH-S - page 18

    Mid -Stop : Activation stops an op ening door; momentary con tact of open button at mid stop will restart d oor to full open position; if door is moving open, consta nt pressure on o pen button will bypass mid-stop . Auto Close Timer : N/ A TS Operation Open Button : Momentary activation; op en override of closi ng door. Close Button : M omentary a ...

  • Linear AUH-S - page 19

    The solenoid o perated brake may require occ asional adjustment. Adjustment i s necessary if doo r tends to drift downward after reachi ng the open limit. Follo w the instructions belo w and use Figure 14 as a guide. (1) Loosen shoe adj usting screw and bottom bracket arm of solenoid. (2) Move tab until drum has a slight drag. (3) Reverse drag slig ...

  • Linear AUH-S - page 20

    CLUTCH ADJUSTME NT The clutch serves to pr otect the do or, the electric operato r and other equipment from undue s tress or damage caused by starting forces and/or an obstructio n to the door. It should be set no tighter than is necessar y to smoothly and consiste ntly move the door throughout its full ra nge of travel. When prop erly set, it will ...

  • Linear AUH-S - page 21

    OPERA T ION & ADJUSTME NT INSTRUCTI ONS 21 ...

  • Linear AUH-S - page 22

    Normally, very little maintenance is required. A mon thly visual inspection must be made for loose or missing hardware and for excessive slack in the V -Belt and j ackshaft chain. The clutc h must be tested perio dically and adjustments made if necessary (see page 20 ). T he brake is adjusted at the factory and will need periodic adj ustment for we ...

  • Linear AUH-S - page 23

    WIRING DI AGRA M/S CHEM A TIC - SIN GLE PHASE 23 575 VOL TS, 3 PHASE SINGLE VOL T AGE MOTOR BL/BLK BL/BLK TO REVERSE MOT OR, SWITCH LEADS 1 & 3 L1 4 L2 YELLOW WHITE BLACK ORANGE BLUE RED Wire Nut Connection 3 BLUE (T ,J,H) YELLOW BLUE RED BLACK A.O. SMITH SINGLE VOL T AGE - 1 15 V AC, 1P MOTOR RED (AU) YELLOW 3 2 1 4 Wire Nut Connection L1 L2 1 ...

  • Linear AUH-S - page 24

    WIRING DI AGRA M/S CHEM A TIC - THREE PH ASE 24 575 VOL TS, 3 PHASE SINGLE VOL T AGE MOTOR BL/BLK BL/BLK TO REVERSE MOT OR, SWITCH LEADS 1 & 3 L1 4 L2 YELLOW WHITE BLACK ORANGE BLUE RED Wire Nut Connection 3 BLUE (T ,J,H) YELLOW BLUE RED BLACK A.O. SMITH SINGLE VOL T AGE - 1 15 V AC, 1P MOTOR RED (AU) YELLOW 3 2 1 4 Wire Nut Connection L1 L2 1 ...

  • Linear AUH-S - page 25

    P ARTS IDENTIFIC A TION 25 Ref Part# Description Assemblies A 109351 Frame Assembly w/Sha f ts. AUJ 109358 Frame As sembly w/Shaft s, AUH C 110076 Clutch Shaft Assembly, AUJ 110077 Clutch Shaf t Assembly w /Hoist, AUH E 109848 Secondary Shaft Asse mbly, AUJ / H (1/3 HP) 109274 Secondary Shaft Assembly, AUJ / H (1/2 & 3/4 HP) G 109273 Brake Asse ...

  • Linear AUH-S - page 26

    26 SPECIFICATIONS MODEL : AUJ_ _ _ _S HP:_____ VOLTS : _____ PHASE : _____ * UL AND CANADIAN UL LIS TED * HIGH STARTING TORQUE, CONTINUOUS DUTY MOTO R * MOTOR OVERLOAD PROTECTI ON * CLASS 2 (24 VOLT) CONTROL CI RCUIT * SOLENOID BRAKE * SOLID STATE MOTOR CONTRO L CIRCUITRY WITH * THREE BUTTON CONTROL: OPEN , CLOSE, STOP * HEAVY GAUGE, POWDER- COATED ...

Manufacturer Linear Category Garage Door Opener

Documents that we receive from a manufacturer of a Linear AUH-S can be divided into several groups. They are, among others:
- Linear technical drawings
- AUH-S manuals
- Linear product data sheets
- information booklets
- or energy labels Linear AUH-S
All of them are important, but the most important information from the point of view of use of the device are in the user manual Linear AUH-S.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Linear AUH-S, service manual, brief instructions and user manuals Linear AUH-S. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Linear AUH-S.

Similar manuals

A complete manual for the device Linear AUH-S, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Linear AUH-S by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Linear AUH-S.

A complete Linear manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Linear AUH-S - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Linear AUH-S, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Linear AUH-S, that we can find in the current document
3. Tips how to use the basic functions of the device Linear AUH-S - which should help us in our first steps of using Linear AUH-S
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Linear AUH-S
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Linear AUH-S in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Linear AUH-S?

Use the form below

If you did not solve your problem by using a manual Linear AUH-S, ask a question using the form below. If a user had a similar problem with Linear AUH-S it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)