Manual Heath Zenith 598-1214-03

36 pages 1.35 mb
Download

Go to site of 36

Summary
  • Heath Zenith 598-1214-03 - page 1

    © 2007 598-1214-03 Remote ContRolled PRoduCts This manual includes operating instructions for the remote controlled products sho wn abov e. All products work on the same principle and use the same code setting information. Please read all instructional information and note any specific information pertaining to your particular product. FEA TURES ...

  • Heath Zenith 598-1214-03 - page 2

    2 598-1214-03 CODE SETTINGS Note: Most single system installations will not require any change to the code setting. T ransmitter(s) and receiver(s) must have the same code and group setting to work to get her . Swi tch es 1 th r ou gh 3 set the co de. Switch 4 sets the Group (A or B). See Code Switch Locations f or switc h locations. T ransmitter(s ...

  • Heath Zenith 598-1214-03 - page 3

    3 598-1214-03 Note: When operating more than one system independently of each other , set each system to a different code. There are 8 codes av ailable by changing the settings of switches 1 through 3. Example 2 - Code Switch Settings, System 2 Receiver(s) Code Group A T ransmitter(s) Code Group Switch (Group A Selection Shown) Example 3 - Code Swi ...

  • Heath Zenith 598-1214-03 - page 4

    4 598-1214-03 Floodlight Con verter W ireless Motion Sensor CODE SWITCH LOCA TIONS Code Switches Close-Up of T ypical Code Switch (Factory Default Setting is Off) Not e: The “X” has been place d on the switches to help clarify the illustra- tions under Code Settings . DETECT CODES 1234 DAY NIGHT NIGHT ONLY ON 1 2 3 4 1 2 3 4 O N 1 2 3 4 Lamp So ...

  • Heath Zenith 598-1214-03 - page 5

    5 598-1214-03 One rem ote con tro l is able to indep en den tl y ope ra te two recei ver units. If more than two receiver units, operating independently , are desired, additional remote controls will need to be purchased. 1. Remov e T ab from Battery Chamber . Remove cov er from back of transmitter . Gently pull tab out of battery chamber (see Figu ...

  • Heath Zenith 598-1214-03 - page 6

    6 598-1214-03 4 5 4 3 1 2 3 2 Note: T o independently operate a second recei ver unit using a single remote control, make sure the second set of code switches (Right Side) and the code switches on each receiver match (see Code Settings section). • Left Side - Set left side code switches. • Right Side - Set right side code switches. IMPORT ANT : ...

  • Heath Zenith 598-1214-03 - page 7

    7 598-1214-03 F igure 3 - Removing V isor Clip (Rear V iew) Flat-Head Screwdriv er Optional Visor Clip Optional Car Visor Clip (Included) The remote control includes an optional car visor clip for added con venience that may be installed. 1. T o attach car visor clip to remote control (if desired) push it into slot on rear of remote unit until it s ...

  • Heath Zenith 598-1214-03 - page 8

    8 598-1214-03 WIRELESS MO TION SENSOR Features: • No wiring required. • Up to 70 feet sensing range, 180° Cov erage. • Adjustable sensiti vity . • Day/Night or Night only operation. • T est mode. • Uses 2 AA batteries. • W all or eav e mount. • Controls recei vers up to 100 feet a way . Select Night or 24 Hour Mode Thi s senso r is ...

  • Heath Zenith 598-1214-03 - page 9

    9 598-1214-03 F igure 5 - Installing Motion Sensor Installing Motion Sensor 1. Install sensor mounting bracket where motion detection is desired. Attach sensor mounting bracket to a sturdy object ( i.e. tree, post, house, etc.) using tw o screws provided (see Figure 5). Make sure unit has an unobstru cted vie w . Note: If mounting bracket to a curv ...

  • Heath Zenith 598-1214-03 - page 10

    10 598-1214-03 Check Operation and Adjustment Note: When first turned on or when switching modes wait 1 1 / 2 minutes. The RANGE control and ON-TIME control are located on the bottom of the sensor (see Figure 6). Using your fingernails or a small, flat-head scre w- dri ver , gently pry the cov er until it opens. 1. Che ck Opera tio n. Set the ON ...

  • Heath Zenith 598-1214-03 - page 11

    11 598-1214-03 3. Ad ju st R an ge Co n tr ol . T o incre as e sens it i vity , tur n the RANGE co ntr ol to war d MAX. T o de- cr eas e sen sit i vi ty , tu rn th e RA NGE con tro l to wa rd MIN . No te : If the R ANG E is set too hig h, f alse tri gg eri ng ma y res ul t i n som e en vi ron me nts . Note : When using test mode to check operati on ...

  • Heath Zenith 598-1214-03 - page 12

    12 598-1214-03 4. S e t O N - T I M E C o n t r o l . Det er mi ne th e amou nt of tim e you wan t the conn ect ed de vice to stay on af ter m ot ion is det ect ed (1 or 5 mi nu tes ). Sl id e th e ON- TI ME co ntr ol to t he co rre sp ond in g s et tin g. IMPORT ANT : A v oid Aiming Control At: • Objects that change temperature rapidly , such as ...

  • Heath Zenith 598-1214-03 - page 13

    13 598-1214-03 FLOODLIGHT CONVER TER Features and Ratings: • Up to 150 W att maximum incandescent load or 240 W att maximum halogen load (up to 75 W att maximum incandescent, or 120 W att maximum halogen, per lamp holder). • Minimal wiring required. • Ins ta ll fix tur e i n a cc ord an ce wi th lo cal c ode s. W ARNING: T urn po wer of f at ...

  • Heath Zenith 598-1214-03 - page 14

    14 598-1214-03 Note: The plastic hanger can be used to hold the fixt ure whil e wirin g. Threa d the sma ll end of the plastic hanger through the hole in the center of the cov er plate. Insert the small end into one of the slots on the mounting strap. 3. Route the wires from the light receiv er through the large g asket holes (see Figure 10). 4. T ...

  • Heath Zenith 598-1214-03 - page 15

    15 598-1214-03 WA RNING - Ri sk of fir e. Do no t a i m t h e l a m ps a t a co m b u st ib le su rf ac e wi th i n 3 ft . (1 m ) . IN DO OR PLUG -I N CO NV ERT ER Features and Ratings: • Up to 300 W att maximum incandescent load. • No wiring required. 1. Plug in indoor recei ver . 2. Plug in light you wish to control. CA UTIO N : Do not excee ...

  • Heath Zenith 598-1214-03 - page 16

    16 598-1214-03 LAMP SOCKET CONVER TER Features and Ratings: • Up to 150 W att maximum incandescent load. • No wiring required. 1. Scre w module into light socket. 2. Scre w incandescent bulb up to rated wattage into module. CA UTION: Do not exceed the maxi- mum load limits listed abo ve . 3. C h ec k o p er at io n . Acti v at e tra nsm it ter ...

  • Heath Zenith 598-1214-03 - page 17

    17 598-1214-03 TR OUBLESHOO TING GUIDE POSSIBLE CA USE 1. Circuit breaker or fuse is turned of f. 2. Interrupted by another device. 3. Does not res pon d immedi ate ly after ins tal - lation. 4. Sig na ls from tran sm it te r are bein g bl oc ke d, or transmitter is out of range. 5. W eak battery in the transmitter . 6. Dip switches on transmitter ...

  • Heath Zenith 598-1214-03 - page 18

    18 598-1214-03 TECHNICAL SER VICE Please call 1-800-858-8501 for assistance before returning pr oduct to store . If you experience a p roblem, fol lo w this gu ide. Y ou may also w ant to visit our W eb site at: www . hzs upp ort.co m. If the prob lem persi sts , call * for assistance at 1-800-858-8501, 7:30 AM to 4:30 PM CST (M-F). Y ou may also w ...

  • Heath Zenith 598-1214-03 - page 19

    19 598-1214-03 PRoduCtos a ContRol Remoto Este manual incluye instrucciones de funcionamiento para los productos a control remoto que se muestran arriba. T odos los productos funcionan basándose en el mismo principio y usan la misma información para la calibra ción del código. Por fa vor lea todas las instruccio - nes y tome en cuenta cualquier ...

  • Heath Zenith 598-1214-03 - page 20

    20 598-1214-03 AD VERTENCIAS: • P ARA USO SÓLO con bombillas incandes- centes o halógenas de 120 voltios. • NO LO USE con bombillas fluorescentes, electrodomésticos, fuentes de energía, alum- brado con bajo voltaje ni con ningún otro aparato eléctrico. CALIBRA CIONES DEL CÓDIGO N o ta : La may oría de instala ciones de sólo un sis tem ...

  • Heath Zenith 598-1214-03 - page 21

    21 598-1214-03 Ejemplo 3 - Calibraciones del interruptor del código con un sólo transmisor Código del receptor(es) Grupo “A” Código del detector remoto de movimiento Cuando se use el detector inalámbrico de mo vimiento, las calibra ciones del código y del grup o deben emparejar con el(los) receptor(es) para que el sistema funcione correct ...

  • Heath Zenith 598-1214-03 - page 22

    22 598-1214-03 ON DIP 1 2 3 4 ON DIP 1 2 3 4 Con vertidor del F aro Detector inalámbrico de movimiento Interruptores de circuito impreso DETECT CODES 1234 DAY NIGHT NIGHT ONLY UBICA CIONES DE LOS INTERRUPT ORES DE CIRCUIT O IMPRESO 1 2 3 4 O N 1 2 3 4 Con vertidor del zócalo de la lámpara Con vertidor enchufable para usarse bajo techo Interrupto ...

  • Heath Zenith 598-1214-03 - page 23

    23 598-1214-03 ON DIP 1 2 3 4 ON DIP 1 2 3 4 CONTROL REMO T O Un cont rol remo to pued e opera r indep endi ent emen te dos unidades receptoras. Si se desea operar independiente- mente más de dos receptores, se necesitarán comprar controles remotos adicionales. 1. Ret ire la alet a del com par ti men to de la bater ía . Re tir e la tapa posterio ...

  • Heath Zenith 598-1214-03 - page 24

    24 598-1214-03 IMPORT ANTE: Espere de 1 a 2 segundos después de pulsar el botón de un transmisor antes de pulsarlo de nue vo para permitir que la transmisión se complete. Nota: S i la luz no se prend e o si se pren de y apa ga intermitentemente cuando se pulsan los botones del transmisor , vea la Guía de Análisis de A verías . Nota: Para oper ...

  • Heath Zenith 598-1214-03 - page 25

    25 598-1214-03 P r es il la o p ci on al d e l vi so r d el c ar r o ( i n c l ui da ) Pa ra mayor con venie ncia , en el cont rol remo to se incluye una presilla opcional del visor del carro que puede ser instalada. 1. Par a unir (si se desea) la presilla del visor del carro al control remoto empújela contra la ranura de la parte posterior del co ...

  • Heath Zenith 598-1214-03 - page 26

    26 598-1214-03 DETECT OR INALÁMBRICO DE MO VIMIENT O Características: • No se requiere cableado. • Margen de sensibilidad hasta 70 pies. 180° de cober- tura. • Sensibilidad ajustable. • Operación diurna/nocturna o sólo nocturna. • Modo prueba. • Usa dos baterías AA. • Montaje en pared o alero. • Co nt rol a l os rec ept o re s ...

  • Heath Zenith 598-1214-03 - page 27

    27 598-1214-03 F igura 4 - Compartimento de la batería (V ista posterior) DETECT CODES 1234 DAY NIGHT NIGHT ONLY Control detector Marca de polaridad F igura 5 - Instalación del detector de movimiento Instalación del detector de movimiento 1. Ins tal e la con sol a de mon taj e del de tec tor en dond e se nece sit e detec tar mov imi en to. Aco p ...

  • Heath Zenith 598-1214-03 - page 28

    28 598-1214-03 2. Instale el detector de movimiento a la consola de montaje. Usando un destornillador cabeza Philips, afloje el tornillo de la abrazadera en la consola de montaje. Inserte la montura giratoria de bola del detec tor en el zóca lo de la consol a de mont aje ( Nota: Usted debería oír un chasquido -un clic-). Apunte el det ec tor ha ...

  • Heath Zenith 598-1214-03 - page 29

    29 598-1214-03 2. Regule el detector . Gire el control de ALCANCE a la posición media y el de DURA CIÓN a la posición TES T (v ea Figur a 6). Camin e por el área de cober tur a y not e su po sic ió n cua nd o el LED emp iec e a des te lla r . Afloj e el tornil lo de la abraz ader a y mue v a el detect or para cambiar el área de cobertura. Cu ...

  • Heath Zenith 598-1214-03 - page 30

    30 598-1214-03 4 . Fije el control de DURA CIÓN. Determine la cantidad de tiempo que desea que el dispositi vo co- nectado permanezca encendido luego que se detecta movimiento (1 ó 5 minutos). Mue v a el control de DURA CIÓN a la configuración correspondiente. IMPORT ANTE: Evite apuntar el control: • A objetos que cambian rápidamente de tem ...

  • Heath Zenith 598-1214-03 - page 31

    31 598-1214-03 CONVERTIDOR DEL F AR O Características y potencias nominales: • Hasta una carg a incandescente máxima de 150 vatios o una carga halógena máxima de 240 v atios (hasta 75 v atios máximo de incandescente, o 120 vatios máximo de halógena por cada portalámparas). • Se requiere un cableado mínimo. • Inst ale el a par ato de ...

  • Heath Zenith 598-1214-03 - page 32

    32 598-1214-03 4. T uerza juntos, como se muestra, los cables de la caja de empalme con los del aparato. Asegúrelos con conectores de alambre que tengan aprobación UL (vea Figura 10). 5. Alinee la placa cubertora con su empaque. Asegúre - los con el perno de montaje (vea Figura 10). 6. Empuje firmemente el tapón de caucho hasta su sitio (vea F ...

  • Heath Zenith 598-1214-03 - page 33

    33 598-1214-03 AD VERTENCIA - Riesgo de incendio. No apunte las lámparas a superficies combusti- bles dentr o de un 1 metro. F igura 11 - Ubicación de los controles Interruptor derivante remoto Control del volumen de la alarma P arlante 10. Re vise la operación. Activ e el transmisor que va a usarse con el receptor (vea las instrucciones del tr ...

  • Heath Zenith 598-1214-03 - page 34

    34 598-1214-03 A CE ® se reserva el derecho de descontinuar productos y de cambiar especificaciones, cuando desee, sin incurrir en ninguna obligación de incorporar las nuev as caracte- rísticas en los productos vendidos anteriormente. 4. Uso del interru pto r deri van te remot o. El recep tor está equipado con un interruptor deriv ante (vea Fi ...

  • Heath Zenith 598-1214-03 - page 35

    35 598-1214-03 GUÍA DE ANÁLISIS DE A VERÍAS CA USA PROBABLE 1. El disyuntor o el fusible está desconectado. 2. Interrumpido por otro dispositivo. 3. No responde inmediatamente lue go de la insta - lación. 4. Las señal es desde el transmi sor están siend o blo- quea das o e l t rans miso r e stá fue ra d e a lcan ce. 5. Batería desgastada e ...

  • Heath Zenith 598-1214-03 - page 36

    36 598-1214-03 INFORMA CIÓN REGULA T ORIA Este aparato cumple con la Parte 15 de las Reglas de la FCC (Comisión Federal de Comunicaciones) y con la RSS-210 de las Industrias del Canadá. El funciona- miento está sujeto a las dos siguientes condiciones: (1) este aparato no puede causar interferencias dañinas, y (2) este aparato debe aceptar cual ...

Manufacturer Heath Zenith Category Universal Remote

Documents that we receive from a manufacturer of a Heath Zenith 598-1214-03 can be divided into several groups. They are, among others:
- Heath Zenith technical drawings
- 598-1214-03 manuals
- Heath Zenith product data sheets
- information booklets
- or energy labels Heath Zenith 598-1214-03
All of them are important, but the most important information from the point of view of use of the device are in the user manual Heath Zenith 598-1214-03.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Heath Zenith 598-1214-03, service manual, brief instructions and user manuals Heath Zenith 598-1214-03. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Heath Zenith 598-1214-03.

A complete manual for the device Heath Zenith 598-1214-03, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Heath Zenith 598-1214-03 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Heath Zenith 598-1214-03.

A complete Heath Zenith manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Heath Zenith 598-1214-03 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Heath Zenith 598-1214-03, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Heath Zenith 598-1214-03, that we can find in the current document
3. Tips how to use the basic functions of the device Heath Zenith 598-1214-03 - which should help us in our first steps of using Heath Zenith 598-1214-03
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Heath Zenith 598-1214-03
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Heath Zenith 598-1214-03 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Heath Zenith 598-1214-03?

Use the form below

If you did not solve your problem by using a manual Heath Zenith 598-1214-03, ask a question using the form below. If a user had a similar problem with Heath Zenith 598-1214-03 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)