Manual Emerson 381333234 E

18 pages 0.46 mb
Download

Go to site of 18

Summary
  • Emerson 381333234 E - page 1

    381333–234 E 50 Hanove r Road, F lorham Park, New J ersey 07932–1591 USA For sales or service call 1 800 800–2726 (A SCO ) www.ascopower .com Operator’s Manual Seri es 200 Automatic T ransfer Switc hing Equipment D–de si gn 30 th roug h 230 amp ere s DANGER is used in this manual to warn o f a hazard situation which, if not avoided, will ...

  • Emerson 381333234 E - page 2

    A typical Catal og N umb er is shown b elow w ith its elemen ts explained: Ca talog Num ber Identif icatio n T ypical D–design Series 200 A TS catalog no. for a solid neutral, 3 pole, 100 amp, 400 V , open type: 200 A 3 100 J 5X Phase Poles Neutral A –s o l i d C – ove rlappi ng Amperes Vo l t a g e Cont rolle r B – swi tchi ng 5X –i f ac ...

  • Emerson 381333234 E - page 3

    SECTION 1 INST ALL A TION 1- - 1 The A SCO Series 200 automatic tr ansfer switc hing equipmen t (A TSE ) consists of a transfer s witching d evice, monitori ng and t ransfer control device (controller), a nd membrane controls (for door m ounti ng). The A T SE is factor y tested . In stall ation requires mou nting the devices into an app ropriate si ...

  • Emerson 381333234 E - page 4

    INST ALL A TION (continued) 1- - 2 De–energize the co nducto rs before mak ing any line or auxiliary circuitry connect ions. Be sure that Normal and E mergency l ine connectio ns are in proper phase ro tatio n. Place engine generator starting cont rol in the OFF posit ion. Make sure engine generato r is not in operatio n. P ower connections A Wir ...

  • Emerson 381333234 E - page 5

    INST ALL A TION (continued) 1- - 3 F unctio nal T est The Fun c t i o n a l T e s t consists of t hree checks: manual operation, v oltage ch ecks, and elec trical oper ation. NOT ICE Do these checks in the order presented to avoid damaging the aut omatic transfer s witching equipment. R ead all instr uctions on the W iring Diagrams and lab els affi ...

  • Emerson 381333234 E - page 6

    INST ALL A TION (continued) 1- - 4 observe these l ights Figure 1–7. Standard controls and indi cators. 2–V o l t a g e C h e c k s First check nameplate o n tra nsfer swi tching devi ce; rated vol tage m ust be the sam e as norm al and emerg ency l ine voltag es. Use ext reme caution when using a meter to measure volta ges in the fo llowing st ...

  • Emerson 381333234 E - page 7

    INST ALL A TION (continued) 1- - 5 p r e s st h i sb u t t o n observe these l ights Figure 1–8. Standard controls and indi cators. 3 – Electrica l Opera tion Th i s pr oce du re wi ll che ck t he elect ri ca l op er at i on o f t he A utomatic T ransfer Sw itching Equ ipment. Close t he automatic trans fer switching equipment enclosure door an ...

  • Emerson 381333234 E - page 8

    Hol d 15 sec .t o start t he engine generator and to transf er the load to emergency . Press to cancel the active exercise period (sto ps engine now or afte r cooldow n) Se e page 5– 1. Hol d 5 sec .t os e t 20 min. engine ex ercise perio d immediately (engine starts) and weekly thereafter . ³ blinks sl owly when button is r eleased (set) and du ...

  • Emerson 381333234 E - page 9

    SECTI ON 3 TEST ING & SER VICE 3- - 1 PREV ENTIV E MAIN TENAN CE R easonab le c are in preven tive main tenanc e will insur e high reliabilit y and long l i fe for the automati c transf er switch. Ope rate t he sw itc h at l east o nce a mo nth .P e r f o r m t h i s four step E lectr ical Oper ation T est. This is a test with load tr ansfer. T ...

  • Emerson 381333234 E - page 10

    TEST ING & SER VICE (continued) 3- - 2 MANUAL L OAD TR ANSFER This pr oced ure w ill m anual ly tr ansfer th e load if th e cont ro lle r is d i sco nne ct ed . Do no t manually operate the transfer switching device until bo th power sources are disconnect ed: open bo th circuit break ers. 1. Ope n n orma l a nd e me rge ncy s ou rce ci r cui t ...

  • Emerson 381333234 E - page 11

    SECTION 4 ADJUSTM ENTS 4- - 1 Ti me D e l ay A dj u s tm e n t Standard ti me delays are set to customer specificati ons (if none specif ied, standard fa ctory sett ings are used). T o change a set ting, follow procedure on pa ge 4-2. Use T able 4-1 as a guide to time del ay valu es and their c orre- sponding adjustment DIP switch or potentiometer. ...

  • Emerson 381333234 E - page 12

    ADJUSTM ENTS (continued) 4- - 2 NOT ICE Do not make any set ting changes while the contro ller is energized. How to Change a Setti ng 1. P reven t the transfer switching dev ice from operat- ing b y discon nect ing one sou rce firs t, then the ot he r, a s f ollo ws: a. If the transf er switching device is in the Normal positi on, open t he emergen ...

  • Emerson 381333234 E - page 13

    SECTION 5 CONTROL FEA TURES – ENGINE EXER CISERS 5- - 1 These timer s periodic ally exer cise the em ergenc y engine-g enerator p lant. They can be set to exerc ise with or w ithout load tran sfer, or they can be c ompl etely disabl ed. The engine-g enerator shou ld be exercised under load once a week for a minimum time period of 20 minutes, or f ...

  • Emerson 381333234 E - page 14

    CONTRO L F EATURES (continued) 5- - 2 OPTIONAL PR OGR AMM ABLE E NG INE E XER CISE R ( Acc e ssory 11CD) The op tional pr og ramm abl e eng ine exerc iser p rovid es seven day s of di ffere nt ex ercise peri ods. The t imer is connected and mounted below the controller. A perm anent bac kup battery maintain s the settin g; w hen power is lost to ti ...

  • Emerson 381333234 E - page 15

    CONTRO L F EATURES (continued) 5- - 3 How to Set Optional P r ogram m able Engine E xer ciser (A ccessory 1 1CD) Proceed w ith care! The automati c transfer switching equipment is energized. Setting the Clock (T ime and Day) Step Press Button Display Mean ing 1 reset 1234567 (blink) 00 00 ¬ f after self -test, cl ears me mor y 2 ↓ hold h ,t h e ...

  • Emerson 381333234 E - page 16

    CONTRO L F EATURES (continued) 5- - 4 INPHASE M ONITOR FOR M OTOR LOAD T RAN SFE R Inphase monitoring logic cont rols tran sfer and retransfer of motor loads, so that i nrush currents do not exceed normal starti ng currents. It avoids nuisa nce tri pping of circ uit breakers and mechan ical dam age to motor coup li ngs. The Motor Load T ransfer fea ...

  • Emerson 381333234 E - page 17

    ...

  • Emerson 381333234 E - page 18

    INDEX Printed in U .S.A. E 2011 ASCO Power T echnologies, L.P . A accessories, 5–2, 5–3, 5–4 auxil iary cir cuits , 1–3 B barriers, 1–2 battery , 4–2, 5–1 buttons, push, 3–1 bypass time delay, 1–5, 2–1, 3–1 C cat alo g nu mber, i nsi d e co ve r cleaning, 3–1 cond uct or s prepar ation, 1–2 termina ls, 1–2 connections en ...

Manufacturer Emerson Category Surge Protector

Documents that we receive from a manufacturer of a Emerson 381333234 E can be divided into several groups. They are, among others:
- Emerson technical drawings
- 381333234 E manuals
- Emerson product data sheets
- information booklets
- or energy labels Emerson 381333234 E
All of them are important, but the most important information from the point of view of use of the device are in the user manual Emerson 381333234 E.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Emerson 381333234 E, service manual, brief instructions and user manuals Emerson 381333234 E. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Emerson 381333234 E.

A complete manual for the device Emerson 381333234 E, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Emerson 381333234 E by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Emerson 381333234 E.

A complete Emerson manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Emerson 381333234 E - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Emerson 381333234 E, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Emerson 381333234 E, that we can find in the current document
3. Tips how to use the basic functions of the device Emerson 381333234 E - which should help us in our first steps of using Emerson 381333234 E
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Emerson 381333234 E
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Emerson 381333234 E in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Emerson 381333234 E?

Use the form below

If you did not solve your problem by using a manual Emerson 381333234 E, ask a question using the form below. If a user had a similar problem with Emerson 381333234 E it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)