Manual Axor 06401XX0

12 pages 3.88 mb
Download

Go to site of 12

Summary
  • Axor 06401XX0 - page 1

    ThermoBalance II Deck V alve Metris S 06401XX0 Focus S 06405000 Solaris E 06450XX0 Stratos E 06451XX0 Metro E 06452XX0 T alis S 06453XX0 C Cross 06454XX0 C Scroll 06455XX0 C Lever 06456XX0 Solaris² E 04172XX0 Allegro² E 04185XX0 Metro² E 04198XX0 Installation Instructions / W arranty ...

  • Axor 06401XX0 - page 2

    2 ThermoBalance II Deck V alve 06401XX0 Metris S 06405000 Focus S 06450XX0 Solaris E 06451XX0 Stratos E 06452XX0 Metro E 06453XX0 T alis S 06450XX0 06451XX0 06452XX0 06453XX0 06454XX0 06455XX0 06456XX0 06401XX0 06405XX0 06454XX0 C Cross 06455XX0 C Scroll 06456XX0 C Lever 04172XX0 Solaris² E 04185XX0 Allegro² E 04198XX0 Metro² E ...

  • Axor 06401XX0 - page 3

    3 04198XX0 04172XX0 04185XX0 T echnical Specification Recommended pressure 45 - 72 psi Maximum hot water temp. 165° F* Recommended hot water temp. 120° - 140° F* Flow rate @ 44 PSI 8 gpm Safety stop 100° F 1/2" female NPT inlets Maximum mounting surface thickness 1 3/8" Hole size in mounting surface 2 3/8" *Know and follow all ap ...

  • Axor 06401XX0 - page 4

    4 Install the rough Rest the rough on the mounting surface. T ighten the lower mounting ring and washer . T ighten the tensioning screws. Install the plaster shield. Remove the upper mounting ring. Screw the lower mounting ring and washer to their lowest position. Insert the rough up through the hole. Install the upper mounting ring. T ighten it as ...

  • Axor 06401XX0 - page 5

    5 If the supplies are not connected to the correct inlets, the valve cannot function properly! Both outlets must be plumbed! Install the hot and cold water supply lines* W rap the threads on the hot and cold supply pipes with T eflon tape. Install the hot and cold supplies to the corresponding inlets. Install the outlet lines* W rap the threads on ...

  • Axor 06401XX0 - page 6

    6 Install the valve trim Remove the plaster shield. Push the escutcheon over the valve. Install the handle. T ighten the screw with a 3 mm Allen wrench. The screw must engage the slot on the cartridge. Justify the handle. Set the high temperature limit stop, if required. Justify the handle T urn the water on to the tub spout or hand- shower . Place ...

  • Axor 06401XX0 - page 7

    7 Set the high temperature limit stop (optional) T urn the water on to the tub spout or handshower . Use a 3 mm Allen wrench to loosen the handle screw . Remove the handle from the valve. Carefully remove the retainer clip and the limit stop ring (1). T urn the temperature control stem until the water is the desired high temperature, usually 110°F ...

  • Axor 06401XX0 - page 8

    8 Maintenance: Clean the filters CAUTION: T urn off the water at the main or with the ser vice stops, before opening the valve. Remove the handle and escutcheon. Failure to hold the stop unit steady while unscrewing or replacing the thermostat car tridge will result in damage to the stop unit. Grasp the wrench flats on the cartridge stop unit with ...

  • Axor 06401XX0 - page 9

    9 Justify the handle. User instructions From the off position, turn the diver ter lever clockwise or counter-clockwise to obtain water from either of the two functions. T urn the temperature control knob clockwise to make the water cooler . T urn it counter-clock- wise to make the water warmer . When turning the knob counter-clockwise, it will stop ...

  • Axor 06401XX0 - page 10

    10 1 cartridge with shutoff unit 88586000 2 thermostat car tridge 94282000 3 Solaris handle 88528XX0 4 Stratos handle 88543XX0 5 Metro handle 88548XX0 6 T alis handle 88549XX0 7 Cross handle 88608XX0 8 Scroll handle 88609XX0 9 Lever handle 88610XX0 10 Metris handle 11 Focus handle 12 escutcheon 13 Allegro² handle 14 Metro² handle XX = color code ...

  • Axor 06401XX0 - page 11

    11 Limited Lifetime Consumer W arranty This product has been manufactured and tested to the highest quality standards by Hansgrohe, Inc. (“Hansgrohe”). This warranty is limited to Hansgrohe products which are purchased by a consumer in the United States after March 1, 1996, and installed in either the United States or Canada. WHO IS COVERED BY ...

  • Axor 06401XX0 - page 12

    Hansgrohe, Inc. • 1490 Bluegrass Lakes Parkway • Alpharetta, GA 30004 T el. 770-360-9880 • Fax 770-360-9887 www .hansgrohe-usa.com US - Installation Instructions • Part No.90445601 • Revised 04/2008 THIS W ARRANTY DOES NOT COVER, AND HANSGROHE WILL NOT P A Y FOR: A. Conditions, malfunctions or damage not resulting from defects in material ...

Manufacturer Axor Category Thermometer

Documents that we receive from a manufacturer of a Axor 06401XX0 can be divided into several groups. They are, among others:
- Axor technical drawings
- 06401XX0 manuals
- Axor product data sheets
- information booklets
- or energy labels Axor 06401XX0
All of them are important, but the most important information from the point of view of use of the device are in the user manual Axor 06401XX0.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals Axor 06401XX0, service manual, brief instructions and user manuals Axor 06401XX0. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product Axor 06401XX0.

Similar manuals

A complete manual for the device Axor 06401XX0, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use Axor 06401XX0 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of Axor 06401XX0.

A complete Axor manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual Axor 06401XX0 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the Axor 06401XX0, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the Axor 06401XX0, that we can find in the current document
3. Tips how to use the basic functions of the device Axor 06401XX0 - which should help us in our first steps of using Axor 06401XX0
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with Axor 06401XX0
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of Axor 06401XX0 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning Axor 06401XX0?

Use the form below

If you did not solve your problem by using a manual Axor 06401XX0, ask a question using the form below. If a user had a similar problem with Axor 06401XX0 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)