Инструкция обслуживания UNICOM FEP-30109T-C

22 страниц 1.45 mb
Скачать

Перейти на страницу of 22

Summary
  • UNICOM FEP-30109T-C - page 1

    908 Canada Court City of Industry , C A 91748 U.S.A. Phone: 626.964.7873 or 800.346.6668 F ax: 626.964.7880 www .unicomlink.com e-mail: info@unicomlink.com ©UNICOM 2005. UNICOM and “A Network Systems Solution” are trademarks of UNICOM Electric, Inc. All rights reserved. Specifications subject to change without notice. Rev: 09.05 8 Port 10/ 100 ...

  • UNICOM FEP-30109T-C - page 2

    Smart-Switch/801 1 Features  Conforms to IEEE 802.3, 802.3u, and 802.3x Ethernet Standards  Eight auto-sensing 10/100Mbps Ethernet RJ-45 ports  Automatic MDI/MDIX crossover for each 10/100Base-TX port  One Fixed 100Mbps Fiber port (SC/ST-Multi-Mode, SC-Single Mode)  Back-Pressure-Base flow control on Half-duplex mode  Pause-Frame- ...

  • UNICOM FEP-30109T-C - page 3

    Smart-Switch/801 2 Package Contents Unpack the contents of the Smart-Switch/801 and verify them against the checklist below.  Smart-Switch/801 Fast Ethernet Switch  Power Cord  Four Rubber Feet  RS-232 console management cable  User Guide Smart-Switch/801 Power Cord Rubber Feet RS-232 cable User Guide Figure 1-2. Package Contents If ...

  • UNICOM FEP-30109T-C - page 4

    Smart-Switch/801 3 Hardware Description This section describes the hardware of the Smart-Switch/801. The physical dimensions of the Smart-Switch/801 are 250mm x 132mm x 37mm (L x W x H) Front Panel The Front Panel of the Smart-Switch/801 consists of eight auto-sensing 10/100Mbps Ethernet RJ-45 ports with automatic MDI/MDIX, one 100Base- FX fiber po ...

  • UNICOM FEP-30109T-C - page 5

    Smart-Switch/801 4 LED Indicators Figure 2-4. LED Indicators There are three LED Indicators (10/100M, LNK/ACT, FDX/COL) for each UTP port and two LED Indicators (LNK/ACT, FDX/COL) for the fiber port. The following table provides descriptions of the LED status. They provide a real-time indication of systematic operation. UTP Ports LED Status Color D ...

  • UNICOM FEP-30109T-C - page 6

    Smart-Switch/801 5 Fiber Port LED Status Color Description On Green The port is successfully connecting with the device. Blinks Green The port is receiving or transmitting data. LK /ACT Off No device attached. On Orange The port is operating in Full-duplex mode. Blinks Orange Collision of Packets occurring within the port. FDX /COL Off The port is ...

  • UNICOM FEP-30109T-C - page 7

    Smart-Switch/801 6 Rear Panel The Console port and 3-pronged power plugs are located at the Rear Panel of the Smart -Switch/801 as shown in Figure 2-8. This Switch will work with AC in the 100-240V AC, 50-60Hz. Range. Figure 2-5 The Rear Panel of the Smart-Switch/801 Console Port: Configuration is done through the console port connector. This requi ...

  • UNICOM FEP-30109T-C - page 8

    Smart-Switch/801 7 Attaching Rubber Feet A _ Make sure mounting surface on the bottom of the Switch is grease and dust free. B _ Remove adhesive backing from the Rubber Feet. C _ Apply the Rubber Feet to each corner on the bottom of the Switch. These footpads protect the Switch from shock and vibration. Figure 2-6. Attaching Rubber Feet to each cor ...

  • UNICOM FEP-30109T-C - page 9

    Smart-Switch/801 8 Network Application This section provides a few samples of network topology in which the Switch is used. Desktop Application The Smart-Switch/801 can be used as a desktop switch, an ideal solution for a small workgroup. Used as a standalone switch, personal computers, servers, and printer servers are directly connected to form a ...

  • UNICOM FEP-30109T-C - page 10

    Smart-Switch/801 9 Segment Application For enterprise networks where large data broadcast are constantly processed, this switch is ideal for connecting workgroups or departments to the corporate backbone. Figure 3-2. Segment Applications Connect PCs, workstations, and servers to each other by connecting these devices directly to the Smart-Switch/80 ...

  • UNICOM FEP-30109T-C - page 11

    Smart-Switch/801 10 Smart-Switch/801 PRINTER COMPUTER SERVER COMPUTER Smart-Switch/801 Fiber Optic Connection (2km - MM) (30km - SM) 200Mbps Figure 3-3. Use fiber port (Smart-Switch/801) to extend the distance between workgroups In the above illustration, two Smart-Switch/801 switches are used to connect two small workgroups. By using fiber ports t ...

  • UNICOM FEP-30109T-C - page 12

    Smart-Switch/801 11 Network Configuration This Section explains how to configure VLAN features via a direct connection to the console port on the rear panel of the Smart-Switch/801. This port is a female DB-9 connector. From the main menu of the console program, the user can configure various functions of the switch. Connecting a Terminal or PC to ...

  • UNICOM FEP-30109T-C - page 13

    Smart-Switch/801 12 Baud Rate: 9600 bps Data Bits: 8 Parity: none Stop Bit: 1 Flow Control: None Figure 4-2. The settings of communication parameters After you have finished parameter settings, press “ OK “. The main console management menu should appear. (You need to reboot the Switch to show Main Menu) ...

  • UNICOM FEP-30109T-C - page 14

    Smart-Switch/801 13 Console Management Console Configuration enables use of a local console terminal or PC to control ports and VLANs on the Smart-Switch/801. Main Menu The Main Menu shows all available switch configuration options. Figure 4-3. The Main Menu of Console Management Per Port Setting From the Main Menu, choose the 1 st Item by typing ? ...

  • UNICOM FEP-30109T-C - page 15

    Smart-Switch/801 14 Figure 4-4. The default Per Port Setting Figure 4-5. Port statuses to configure Setting VLAN A VLAN (Virtual LAN) is a group of switch ports designated by the switch as belonging to the same broadcast domain. This feature allows workgroups to be defined on the basis of their logical location instead of their physical location. V ...

  • UNICOM FEP-30109T-C - page 16

    Smart-Switch/801 15 Grouping the switch ports into broadcast domains and assigning them to the same VLAN increases performance and network capacity. Moreover, VLAN groups can be modified at any time to add, remove, or change users without any re-cabling. From the Main Menu, choose the second item “ Setting VLAN “ by typing “ 2 “. Follow the ...

  • UNICOM FEP-30109T-C - page 17

    Smart-Switch/801 16 Figure 4-7. The process of creating VLAN group Continue to configure the other ports with another VLAN group. In the following example, we create three VLAN groups (VLAN 1: Port 4, 5, 6; VLAN 2: Port 1, 2, 3, 4; VLAN 3: Port 4, 7, 8, 9) and the 4 th port may be connected to an MIS member. Restore Factory Setup If you make a mist ...

  • UNICOM FEP-30109T-C - page 18

    Smart-Switch/801 17 Troubleshooting This section helps solve the most common problems on the Smart- Switch/801. Incorrect connections  Faulty or Loose Cables Look for loose or obviously faulty connections. If they appear to be OK, make sure the connections are snug. If that does not correct the problem, try a different cable.  Non-standard ca ...

  • UNICOM FEP-30109T-C - page 19

    Smart-Switch/801 18 LED Diagnostic Indicators The Switch status can be easily monitored through panel indicators. If the power indicator does not light when the power cord is plugged in, you may have a problem with AC power outlet or power cord. However, if the Switch powers off once running, Check for loose power connections, power losses, or surg ...

  • UNICOM FEP-30109T-C - page 20

    Smart-Switch/801 19 Technical Specifications Standards Compliance IEEE 802.3 10Base-T Ethernet, IEEE 802.3u 100Base-TX/FX Fast Ethernet IEEE 802.3x Flow Control Protocol CSMA/CD Max Forwarding and Max Filtering Rate 14,880 pps per Ethernet port, 148,800 pps per Fast Ethernet port Packet size 64 ~ 1522 bytes LED Diagnostic Indicators Per Port: (10/1 ...

  • UNICOM FEP-30109T-C - page 21

    Smart-Switch/801 20 ...

  • UNICOM FEP-30109T-C - page 22

    908 Canada Court City of Industry , C A 91748 U.S.A. Phone: 626.964.7873 or 800.346.6668 F ax: 626.964.7880 www .unicomlink.com e-mail: info@unicomlink.com ©UNICOM 2005. UNICOM and “A Network Systems Solution” are trademarks of UNICOM Electric, Inc. All rights reserved. Specifications subject to change without notice. Rev: 09.05 8 Port 10/ 100 ...

Производитель UNICOM Категория Switch

Документы, которые мы получаем от производителя устройства UNICOM FEP-30109T-C мы можем разделить на несколько групп. Это в частности:
- технические чертежи UNICOM
- инструкции обслуживания FEP-30109T-C
- паспорта изделия UNICOM
- информационные брошюры
- энергетические этикетки UNICOM FEP-30109T-C
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания UNICOM FEP-30109T-C.

Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа UNICOM FEP-30109T-C, инструкции обслуживания, короткие инструкции или инструкции пользователя UNICOM FEP-30109T-C. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия UNICOM FEP-30109T-C.

Похожие инструкции обслуживания

Полная инструкция обслуживания устройства UNICOM FEP-30109T-C, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто "руководство" - это технический документ, цель которого заключается в использовании UNICOM FEP-30109T-C пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей UNICOM FEP-30109T-C.

Полная инструкция обслуживания UNICOM, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.

1. Вступление и рекомендации, как пользоваться инструкцией UNICOM FEP-30109T-C - В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания UNICOM FEP-30109T-C, FAQ и самых распространенных проблем - то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание - индекс всех советов, касающихся UNICOM FEP-30109T-C, которое найдем в данном документе
3. Советы по использованию основных функций устройства UNICOM FEP-30109T-C - которые должны облегчить нам первые шаги во время использования UNICOM FEP-30109T-C
4. Troubleshooting - систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем UNICOM FEP-30109T-C
5. FAQ - чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра UNICOM FEP-30109T-C в данной стране, если самостоятельно не получится решить проблему.

У вас вопрос, касающийся UNICOM FEP-30109T-C?

Воспользуйтесь формуляром, находящимся ниже

Если с помощью найденной инструкции Вы не решили свою проблему с UNICOM FEP-30109T-C, задайте вопрос, заполнив следующий формуляр. Если у какого то из пользователей была похожая проблема с UNICOM FEP-30109T-C со всей вероятностью он захочет поделиться методом ее решения.

Перепишите текст с картинки

Комментарии (0)