    I N S TA L L AT I O N INSTRUC TIONS AND SAFET Y INFOR MA TION FOR TH E VIKIN G H-10 GA TE OPER A T OR CLASS I, CLASS II, CLASS III, AND CLASS IV Residential and Commercial Vehicular Slide Gate Operator AND SAFET Y INFOR MA TION FOR TH E VIKIN G H-10 GA TE OPER A T OR CLASS I, CLASS II, CLASS III, AND CLASS IV Residential and Commercial Vehicular Sl ...

  • Viking Access Systems H-10 - page 2

    THE V I KI N G H- 10 ™ S LI D E GA TE OP E RA T O R The H-10™ gate operator has the capacity to operate slide gates up to 2200 lbs. and 75 ft. in length at 100% duty cycle under extreme conditions. This effi cient operator provides a solution for high traffi c residential and commercial slide gate applications. The Viking H-10™ gate operato ...

  • Viking Access Systems H-10 - page 3

    H- 10 V ehicular Gat e Operat or • R e vision H1 0NXMN10.E • December 2013 ...

  • Viking Access Systems H-10 - page 4

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 2 P ARTS DIA GR AM : Item Description Part No. 1 Chassis VNXL3CH 2 Chassis Battery Br acket VNXCHBBRK 3 Gear Box VNXL3GB 4 Motor VNXH10MO 5 Electr onic Positioning Sensor 2 (EPS2) VNXSLEPS2 6 40B17 Spr ocke t V AL3SP17 7 Idler Pulley DSIP10 8 Idler Bushing ( w/har dwar e) DSIB10 9 Batt ery Swit ch DUMRS20 10 ...

  • Viking Access Systems H-10 - page 5

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 3 OPER A TOR REFERENC ES: 1 . OPERA TOR C O VER 2 . C O VER LOCK 3. A C CESS DOOR ex ternal ac cess to the Manual Release S witch and Alarm Reset But ton 4. BA TTERY B A CK UP S YS TEM 5. VFLEX C ONTROL BO ARD 6. BA TTERY S WITCH disconnects ba tteries fr om the charging cir cuit during tr oubleshooting 7. E ...

  • Viking Access Systems H-10 - page 6

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 4 C ONTROL BO ARD REFERENC ES: 1. POWER HARNES S C ONNECT OR pro vides pow er to the contr ol board. pg 18- 19 2. “OPEN LEFT” & “OPEN RIGHT” pro vides pow er to the motor . pg 20 3. LIMIT SETUP BUTTONS sets limit positions. pg 20- 21 4. FEA TURE ACTIV A TION TRIM POTS activ ate and set f eatur es ...

  • Viking Access Systems H-10 - page 7

    VIKI NG TEC HNIC AL S UPPO RT 1. 800.908 .088 4 5 T A BLE OF CONTENT S: P A RTS DIA GR AM/P A RTS LIST 2 O P E R A T O R R E F E R E N C E S 3 CONTROL BOARD REF ERENC ES 4 I M P O R T A N T S A F E T Y I N F O R M A T I O N 6 -1 2 Important Safe ty Instruct ions 6 Important Install at ion Inst ructi ons 7 Maint enance 8 Ge nera l Safet y Preca utio ...

  • Viking Access Systems H-10 - page 8

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 6 IMPORT A NT SAFET Y INFORMA TION ! W A RN I NG ! N ot Following thes e inst ruc tions m ay cause s ev e re inju ry o r death . IMPORT ANT SAFET Y INSTRUCTIONS ! W A RN I NG ! T o r educe th e risk of severe inju ry o r death . 1 . RE AD A ND FOL L O W ALL I NST RUC TI ONS . 2 . Never let child ren ope rate ...

  • Viking Access Systems H-10 - page 9

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 7 IMPORT A NT SAFET Y INFORMA TION ! W A RN I NG ! N ot Following thes e inst ruc tions m ay cause s ev e re inju ry o r death . IMPORT ANT INST ALL A TION I NSTRUCTIONS ( Continued) 6 . Controls inten ded for u ser ac tivation must b e loc ated at leas t six feet ( 6’) awa y f rom any moving par t of the ...

  • Viking Access Systems H-10 - page 10

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 8 IMPORT A NT SAFET Y INFORMA TION ! W A RN I NG ! N ot Following thes e inst ruc tions m ay cause s ev e re inju ry o r death . MAINTENANCE Remove the Pow er Ha rnes s from the Co ntrol Board . ( refer to pag e 1 8) • Clea nandl ubric atet hegatetrackwh eelsu singthereco mmen ...

  • Viking Access Systems H-10 - page 11

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 9 ! C AU TI O N : T o Red uce the Ri sk of Fire or I njur y to Per sons : IMPORT A NT SAFET Y INFORMA TION a. Use on ly the following t ype an d siz e batter y(ies ): Y uasa N P7 - 12 or V IKI NG D UBA12 b. Donotdi sposeoftheb atter y(ies )inre.Th ecellsmayexplode .Che ...

  • Viking Access Systems H-10 - page 12

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 10 IMPORT A NT SAFET Y INFORMA TION NOTE: T his t ype on in sta llation DOES NO T rev erse t he gate all t he way back to its li mits wh en the p hoto bea m is obs truc ted. T his in stall ation is o nly to protec t aga inst e ntrapm ent an d to comply with U L 325 . Sec ondar y Ent rapment Pro tection Phot ...

  • Viking Access Systems H-10 - page 13

    VIKI NG TEC HNIC AL S UPPO RT 1. 800.908 .088 4 11 NOTE: T his t ype on in sta llation DOES NO T rev erse t he gate all t he way back to its li mits wh en the e dge se nsor i s obstr uc ted. Th is ins tall ation is on ly to protect aga inst e ntrapm ent an d to comply with U L 325 . Sec ondar y Ent rapment Pro tection Edge Sen sor ( cont act sensor ...

  • Viking Access Systems H-10 - page 14

    VIKI NG TEC HNIC AL S UPPO RT 1. 800.908 .088 4 12 Audible Alarm R eset S witch Installation Manual R eset f or the A udible Al arm • UL 32 5 stan dard requ ires an au dible a larm to go of f af ter two conse cutiv e ev ents detec ted b y the prim ar y entrapm ent protectio n of the gate operator ( obstr uctio n sensor ). • The a udible a ...

  • Viking Access Systems H-10 - page 15

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 13 ! C AU TI O N : T o Red uce the Ri sk of Fire or I njur y to Per sons : ! W ARNING: For use wi th gates at a ma ximum 2 20 0 lbs . in weight or 75 f t . in le ngth . IMPORT A NT INST ALL A TION INF ORMA TION 2200 lb. 75 ft Locate Cont rol Buttons: 1 . Within sight of the gate, 2 . At a minimum h eight of ...

  • Viking Access Systems H-10 - page 16

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 14 G AT E O P E R AT O R I N S TA L L AT I O N Concrete Pad Optio n 1 . Follow the loc al buil ding cod e to det ermin e the requ ired depth of the co n cre te p a d . 2 . Pad me asure ment s recomme nd ed by Viking Access Syst ems a re at least 24” long , 18 ” wid e and 24” dee p to ensure the st able ...

  • Viking Access Systems H-10 - page 17

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 15 Pos t Mountin g Optio n TIP: The o perator is eq uipp ed for p ost mou nt appli cations a nd is ready for insta llation . Y ou will o nly ne ed to supply the p osts a nd u -bolt s . 1 . Con sult the loc al bu ilding co des for th e depth an d concrete requirem ents . 2 . Maxim um 3 .0 0” O D pipe . 3 . ...

  • Viking Access Systems H-10 - page 18

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 16 Operat or Positioning ! I M P O R TA N T: All ope nings of a h oriz ontal sli de gate are gua rded or s creen ed from the b ot - tom of the gate t o a minim um of 4 feet ( 1 . 2 2 m ) a bov e the groun d t o prev ent a 2- 1/2 inch (57 . 2 m m ) diam eter sphe re from pas sing throug h the op ening s anywh ...

  • Viking Access Systems H-10 - page 19

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 17 G AT E O P E R AT O R I N S TA L L AT I O N ! TECHNICAL TIP: B efore comp leting the in stallatio n procedu re; • Openandclosethegatemanually,makingsurethereissufcientspacebetweenthegate and adjacent walls. • Check that the wheels are turning freel ...

  • Viking Access Systems H-10 - page 20

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 18 High V oltage Suppl y Opti on ! Caution : Alwa ys turn off p ow er brea kers when work ing with high voltage . D O N OT conn ec t the “ Pow er Ha rnes s” to the Control Bo ard until the ele ctric al inst allation is comple t e and r eady f or v erificat ion . ELE CTRICA L IN ST A LL A TION 1a 1b 3b 2a ...

  • Viking Access Systems H-10 - page 21

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 19 A Lo w V oltage Suppl y Opti on TIP: The o perator is eq uipp ed with a Modular Pow er Box t hat ca n be relo cated to provide power for low v oltag e inst allations . Su pplies 24V AC t o the ope rator . ! Caution : Alwa ys turn off p ow er brea kers when work ing with high voltage . D O N OT conn ec t t ...

  • Viking Access Systems H-10 - page 22

    VIKI NG TEC HNIC AL S UPPO RT 1. 800.908 .088 4 20 LIMI TS SETUP Tip: Th e gate can b e mov ed el ectron ically with the “O pen ” , “ Stop” an d “Close ” buttons on the C ontrol Boa rd or man ually by following the ins tructio ns on pa ge 11 . ! IMPORT ANT : In the event of a complete power failu re, inclu ding bat ter y back up, the li ...

  • Viking Access Systems H-10 - page 23

    VIKI NG TEC HNIC AL S UPPO RT 1. 800.908 .088 4 21 LIMI TS SETUP T o Readjust the Open Limit: 1 . Clea r the current li mit setting by hol ding down the “O pen Lim it ” but ton until the LED is f lashi ng. 2 . Repe at STEP 2 o n page 2 0 t o set the limit . T o Readjust the Close Limit: 1 . Clea r the current li mit setting by hol ding down the ...

  • Viking Access Systems H-10 - page 24

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 22 T w o Wir e C ommunica tion ! IMPORT ANT : DO N O T run the M aster /Slav e commu nication c abl e in the sam e cond uit or within 12 ” of 1 15 - 23 0v power supp ly cabl es . ! T echnical Tip : DO NOT set the “Ti mer ” an d/ or “O v erla p” features o n both ope rators Control B oards . Only tu ...

  • Viking Access Systems H-10 - page 25

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 23 Wireless Com munic ation O ptions ! T echnical Tip : DO NOT set the “Ti mer ” an d/ or “O v erla p” features o n both ope rators Control B oards . Only tu rn these fe atures on at the M aster Co ntrol Board . MA STER /SL A V E SE TUP REQUIRED ADD-ON: Cho ose option A or B A . Vikin g K onn ec t - ...

  • Viking Access Systems H-10 - page 26

    VIKI NG TEC HNIC AL S UPPO RT 1. 800.908 .088 4 24 Initial Setting s C ONTROL BO ARD SE TUP “Timer ” Hold Open Timer Automatically clos es the gate af ter the sel ec ted amou nt of time from 1 - 60 seco nd s . T urn ing the dia l betwee n “0 ” and “ OFF” will disa ble this featu re, requiri ng a close comm and to close the g at e. “Sp ...

  • Viking Access Systems H-10 - page 27

    VIKI NG TEC HNIC AL S UPPO RT 1. 800.908 .088 4 25 Initial Setting s NOT E: I nstall ing a shu nt or jump er on th e pins will ac tivate t he featu re. C ONTROL BO ARD SE TUP ! IMPORT ANT : Reg ardles s of the power failure option s chose n, th e gate can be m ov ed man ually with a relatively low amount of fo rce b y f ollowing the steps for “ M ...

  • Viking Access Systems H-10 - page 28

    VIKI NG TEC HNIC AL S UPPO RT 1. 800.908 .088 4 26 Obstruct ion Sensor ( Pr imar y Entrapment Prot ection ) ! IMPORT ANT : The a ppropriate “O DS” settin g is dep end ant upo n the gate insta llation and co nstruc tion . Set this fe ature accordingly. A dditiona l Safet y equ ipme nt shoul d be use d to reduce pos sible risk of in jur y or vehi ...

  • Viking Access Systems H-10 - page 29

    VIKI NG TEC HNIC AL S UPPO RT 1. 800.908 .088 4 27 C ONTROL BO ARD SE TUP Viking Heater The op erator ha s an integrated he at er that is th ermos tatically controlle d. Ac tivat e this feature whe n the op erator is used i n applic ation temp eratures down to - 20 °F ( - 29 °C). HEATER CLS ON LOCK MOD ON T o s et the h eate r to tu rn on at t he ...

  • Viking Access Systems H-10 - page 30

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 28 (THIS P AGE LEFT BL ANK INTENTIONALL Y) ...

  • Viking Access Systems H-10 - page 31

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 29 Re - Open Pho to Beam ( v ehicular Safety) NOT E: Thi s typ e of photo-b eam in stall ation will stop then R E-O PEN th e gate all the wa y to the open li mit when the b eam i s obstruc ted. I ntende d for vehicula r safet y ON L Y . For the pur pose of pe destria n entrapm ent, se e pag es 10 -11 . A C C ...

  • Viking Access Systems H-10 - page 32

    VIKI NG TEC HNIC AL S UPPO RT 1. 800.908 .088 4 30 Radio Receiv er ( T ypica l) ! IMPORT ANT : The H old O pen “ Tim er ” setting (p age 24 ) aff ect s how the gate will respo nd to the radio rece iv er com man d. A C C ESS OR Y C ONNECT IONS The control bo ard provides two mod es of ope ration that a radio re ceiver can contro l the g ate: Ope ...

  • Viking Access Systems H-10 - page 33

    VIKI NG TEC HNIC AL S UPPO RT 1. 800.908 .088 4 31 Anti- T ailgate, Open Commands & G uard Station ! TECHNICAL TIP: For more inf ormat ion regar ding acces sory connections and t ermin al fu nctio ns, refe r to “ App end ix ( A )” on pag es 42-43 . A C C ESS OR Y C ONNECT IONS “ A TG ” Anti- T ailgate This in put will stop the gate when ...

  • Viking Access Systems H-10 - page 34

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 32 Viking Loop Rac k TIP: This op erator may be eq uippe d with a pre-wired Loop Rack that plug- in typ e loop detec t ors c an be co nne cted to. This provides a convenient a lternativ e to the box typ e loo p detectors that woul d nee d to be wired to t he control bo ard. Vi king do es not provide eithe r ...

  • Viking Access Systems H-10 - page 35

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 33 Guidelines for Loop Installation Table C - Recommended Number of Turns Perimeter (ft.) Number of Turns 10 5 20 4 30-40 3 50-100 2 A C C ESS OR Y C ONNECT IONS 1 . Prev ent sha rp corne rs in the g eom etry of the lo op sen sor . 2 . Ins tall the a ppropriate num ber of tur ns for your lo op ge ometr y bas ...

  • Viking Access Systems H-10 - page 36

    VIKI NG TEC HNIC AL S UPPO RT 1. 800.908 .088 4 34 Magnetic Lock , Lock Soleno id NOT E: Vi king Access Syst ems d oes not p ro vide externa l gate lock devices . The se items ca n be purch ased f rom your deal er or di stributor . A C C ESS OR Y C ONNECT IONS ( + ) ( + ) ( + ) ( + ) Magnetic Lock Lock Solenoid Pow e r f or the L ocks: Do not u se ...

  • Viking Access Systems H-10 - page 37

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 35 Barrier Arm ( B - 12) S ynchronization Option NOT E: Th e Control Bo ard provides a conv enie nt solution fo r appli cations that re quire synch roniz ed op eration with the Vik ing Ba rrier A rm Op erator mod el B-12 . This t ype of ap plication o pen s and cl oses in the foll owing pattern: 1 . Op en Co ...

  • Viking Access Systems H-10 - page 38

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 36 LED Referenc es In ad dition to the L CD Disp lay , the control boa rd LEDs mo nitor the various ci rcuits of the control boa rd. Use the t able b elow to identif y the corresp ond ing “ TS Ref# ” a nd refer to page 38- 4 1 for further tr o ubleshoot ing. TROUBL ESHOO TING # LED Status Meaning Page 41 ...

  • Viking Access Systems H-10 - page 39

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 37 TROUBL ESHOO TING LED Referenc es Use the ta ble b elow to identif y the corresp ondi ng “ TS Ref# ” an d refer to page 3 8 -41 for fur ther t roubles hooti ng. # LED Status Meaning Pg 41 TS R ef#(s ) 9 “C Loop” OFF Normal Condition. SOLID Control Board is receiving an input from a device connecte ...

  • Viking Access Systems H-10 - page 40

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 38 TRO UBLESHOO TING Call out LCD Display, Diag- nose Button and Diag- nose LED LCD MSG Meaning Page 41 TS Ref #s VIKING ACCESS Welcome Message MODEL H10 Indicates the Model of the unit S yst em Status Messages GATE IS IDLE Gate is stopped between limits GATE IS OPENING Gate is opening GATE IS CLOSING Gate i ...

  • Viking Access Systems H-10 - page 41

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 39 TROUBL ESHOO TING L CD Displa y Referenc es LCD MSG Meaning Page 41 TS Ref #s Multi Met er Displa ys MOT AMP __._ A This is the motor current amperage during operation MOT VOLT __._ VDC This is the actual motor voltage during operation AC VOLT __._ VAC This is the actual low voltage AC to the Control Boar ...

  • Viking Access Systems H-10 - page 42

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 40 TROUBL ESHOO TING L CD Displa y Referenc es LCD MSG Meaning Page 41 TS Ref #s Err or Messages ERR AC LOW Indicates that the 24VAC supply to the VFlex Board is too low from the 115/230 power supply. 1, 3, 20 ERR AC HIGH Indicates that the 24VAC supply to the VFlex Board is too high from the 115/230 power s ...

  • Viking Access Systems H-10 - page 43

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 41 TROUBL ESHOO TING Soluti ons Be gin the troubl esho oting process by referring to the er ror mess ages o n the L CD Displ ay and/ or the St atus LEDs on th e control board . Use pag es 36 - 40 to identif y the T rou blesh ooting Refe rence # ( TS Ref#) then refe rence the t able b elow . TS R ef# CHECK Pa ...

  • Viking Access Systems H-10 - page 44

    VIKI NG TEC HNIC AL S UPPO RT 1. 800.908 .088 4 42 A c c ess C ontrol Connections Appe nd ix ( A ) Pow e r C onnections The control bo ard provides a 24 VDC outp ut t o power external d evices and controls . Alternatively , for d evices that require a p ow er supp ly other than 24VDC , t h e ope rators Pow er B ox c ontai ns a conv enie nt 120V AC ...

  • Viking Access Systems H-10 - page 45

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 43 Rela ys In General NOT E: Vi king Access Syst ems d oes not p ro vide the extern al safet y devices an d access controls . These items c an be p urchase s from your de aler o r distrib ut or . APPE NDIX ( A ) In General In rega rds to the Viking control bo ard, all externa l safet y devices and a ccess co ...

  • Viking Access Systems H-10 - page 46

    VIKI NG TEC HNIC AL S UPPO RT 1. 800.908 .088 4 44 Common Radio R ec eiv ers - Connections Appe nd ix ( B ) Common Radio R ec eiv ers - Connections Appe nd ix ( B ) ...

  • Viking Access Systems H-10 - page 47

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 45 Solar Applications NOT E: Vi king recom men ds Sol ar Packa ge ( pa rt # V A-SOCH P ) for most g ene ral sola r app lications . Altern ativ ely , i ndividu al an d third par ty so lar com pone nts c an be u sed . The follow ing are minimum system r equirement s and installation information. APPE NDIX ( C) ...

  • Viking Access Systems H-10 - page 48

    VIKING TECHNICAL SUPPORT 1.800. 908.0884 46 VIKING EXP A NSION PROD UCTS VIKING SOL AR KIT The comp one nts in clude d in this pa ckage are intend ed to pro vide suf f icient power for g ene ral app lication s. Par t# V A-SOCH P This Kit includes the follo wing c omponents: (2) 12V 40W Solar Pa nel s Part# V A - SO40W (wir ed in se ries = 24V 80W) ...

  • Viking Access Systems H-10 - page 49

    OUR C ONTINUOUS C OMMITME NT TO E X CELLENC E Viking Access Systems is continuously working hard to identify and design products that will appeal to the industry and its needs. As technology continues to advance, we have developed a completely effi cient and intelligent line of gate operators to meet the changing demands. These machines offer: ful ...

  • Viking Access Systems H-10 - page 50

    VIKI NG A CCESS SYSTEMS 63 1 W ald I rvine , CA 926 18 Phone 8 0 0.9 0 8. 08 8 4 F ax 9 49.7 53 .16 40 ww w . vikingacc ess .c om ST AN D ARD FE A TURE S AND OPER A T OR SPECIFICA TIONS INST ALLA TION D A TE: __________________________________ CO MPANY / I NST ALLER: ________________________________ C O N TA C T: ___________________________________ ...

Produzent Viking Access Systems Kategorie Photo Scanner

Dokumente, die wir vom Produzenten des Geräts Viking Access Systems H-10 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Viking Access Systems
- Bedienungsanleitungen H-10
- Produktkarten Viking Access Systems
- Informationsbroschüren
- oder Energieetiketten Viking Access Systems H-10
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Viking Access Systems H-10.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Viking Access Systems H-10, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Viking Access Systems H-10. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Viking Access Systems H-10 ansehen.

Die komplette Bedienungsanleitung des Geräts Viking Access Systems H-10, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Viking Access Systems H-10 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Viking Access Systems H-10 verständlich ist.

Eine gänzliche Bedienungsanleitung von Viking Access Systems sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Viking Access Systems H-10 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Viking Access Systems H-10 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Viking Access Systems H-10, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Viking Access Systems H-10 - die uns die ersten Schritte während der Nutzung von Viking Access Systems H-10 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Viking Access Systems H-10 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Viking Access Systems H-10 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Viking Access Systems H-10?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Viking Access Systems H-10 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Viking Access Systems H-10 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)