    Installation, Operating, Maintenance and After Sales Manual. Product Serial Number: Please leave this manual with the end user . Part Number: 1370064 Issue 2 heating through innovation. SLIM-LINE RC 01.07.2009 ISSUE 2 22369 Slimline RC Manual:Layout 1 10/11/09 16:02 Page 2 ...

  • Myson 1370064 - page 2

    1.0 General Information 03 2.0 Heating System Design 03 3.0 Unit Selection/Sizing 03 4.0 Location 03 5.0 Preparation 04 6.0 Fixing 04 7.0 W ater Connections 05 8.0 Electrical Connection 06 9.0 Commissioning Procedur e 07 10.0 T echnical Data 08 11.0 Operating Instructions 09 12.0 T roubleshooting 10 13.0 Maintenance 11 Contents 22369 Slimline RC Ma ...

  • Myson 1370064 - page 3

    03 SLIM-LINE RC 1.0 General Information 2.0 Heating System Design G This MYSON SLIM-LINE RC fan convector is designed for wall mounted installation with a minimum installation height of 150mm to the underside of the unit. G The SLIM-LINE RC should only be used on closed circulation, two pipe, pump assisted central heating systems. G The SLIM-LINE R ...

  • Myson 1370064 - page 4

    04 SLIM-LINE RC 5.0 Preparation Before pr oceeding with the installation, unpack the carton contents and check against the checklist below: 1. SLIM-LINE RC unit. 2. 15mm isolating valves (1 pair). 3. Instruction manual. 4. W arranty card. 5. Fixing kit (rubber mounts and cable gland). 6. Remote control handset. 6.0 Fixing G Using the fixing dimensi ...

  • Myson 1370064 - page 5

    05 SLIM-LINE RC 7.0 W ater Connections G Connect unit to system flow and return pipes using the two 15mm isolating valves (see fig. 2). Note: T o ensure ef fective venting of the heat exchanger the flow pipe should be connected to the bottom connection of the heat exchanger . Note: For SLIM-LINE RC installations pipe-work must not be routed dir ect ...

  • Myson 1370064 - page 6

    06 SLIM-LINE RC G This unit is supplied with factory fitted test leads. Remove these and discard. G A fused electrical spur with a maximum 3A fuse and a switch having 3mm separation on all poles must be provided in an easily accessible position adjacent to the unit. G Electrical cable entry to the unit should be made through the underside of the un ...

  • Myson 1370064 - page 7

    07 SLIM-LINE RC 9.0 Commissioning Procedur e G Fill and vent the system. G Open both valves fully and vent air from the heat exchanger by unscrewing the air bleed valve situated above the valves in the angled top of the chassis. G Check for leaks at pipe connections. G Refit the outer case and secure using the 2 fixing scr ews. G Switch on electric ...

  • Myson 1370064 - page 8

    T ested in accordance with BS 4856 Part 1. Flow rate 340 ltr/h (75 gal/h). Flow Rate Correction Factors: 455 ltr/h (100 gal/h) multiply by 1.03 227 ltr/h (50 gal/h) multiply by 0.96 113 ltr/h (25 gal/h) multiply by 0.85 Electrical supply 230V 50Hz T est pressur e 20bar (1MPa) Max working pressur e 10bar (1MPa) W ater connections 15mm compression Un ...

  • Myson 1370064 - page 9

    09 SLIM-LINE RC 11.0 Operating Instructions Description This SLIM-LINE RC unit is fitted with a control system that provides either automatic or manual contr ol of the unit. In automatic mode the desired temperatur e set point is selected and the unit will adjust the fan speed according to the dif ference between the actual room temperatur e and th ...

  • Myson 1370064 - page 10

    Manual Manual mode can be used for air circulation without heat or for manual control of the heating function. Use ‘+’ to scroll Selected fan speed beyond 35°C displayed Or use ‘-’ to scroll below 15°C Scrolling back out of manual using the ‘+’ or ‘–’ button will r evert the unit back to last temperature set point. Locking Unit ...

  • Myson 1370064 - page 11

    11 SLIM-LINE RC 12.0 T roubleshooting (continued...) Common Installation Faults For optimum performance, this unit must be correctly sized to match the heat loss requir ements of the space it is requir ed to heat, and the heating system must be correctly designed to provide adequate flow of hot water to the unit (r efer to section 2). If the recomm ...

  • Myson 1370064 - page 12

    heating through innovation. After Sales Service: MYSON Service, Somerden Road, Hull, East Y orkshire HU9 5PE T : 01482 713927, F: 01482 789056, service.convectors@myson.co.uk Spare parts and technical help on all Convector products ar e available from MYSON Service. MYSON Eastern Avenue, T eam V alley , Gateshead, T yne & Wear NE11 0PG, UK T: 0 ...

Produzent Myson Kategorie Patio Heater

Dokumente, die wir vom Produzenten des Geräts Myson 1370064 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Myson
- Bedienungsanleitungen 1370064
- Produktkarten Myson
- Informationsbroschüren
- oder Energieetiketten Myson 1370064
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Myson 1370064.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Myson 1370064, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Myson 1370064. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Myson 1370064 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Myson 1370064, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Myson 1370064 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Myson 1370064 verständlich ist.

Eine gänzliche Bedienungsanleitung von Myson sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Myson 1370064 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Myson 1370064 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Myson 1370064, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Myson 1370064 - die uns die ersten Schritte während der Nutzung von Myson 1370064 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Myson 1370064 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Myson 1370064 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Myson 1370064?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Myson 1370064 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Myson 1370064 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)