Agilent Technologies 34970A - page 1
4XLFN5H IHUHQF H*XLGH SCPI Co mmand Summa ry The following conventions are used for SCPI command syntax for remote interface programming: • Square brackets ( [ ] ) indicate o ptional keywords o r parameters. • Braces ( { } ) enclose parameter choices with in a command string. • Triangle brackets ( < > ) enclose parameters for whic ...
-
Agilent Technologies 34970A - page 2
Scan Measurement Commands ( see page 226 in the User’s Gu ide ) MEASure :TEMPerature? { TCoup le |RTD|FRTD|THERmi stor|DEF} ,{< type >|DEF}[,1[,{< resolution >|MIN|MAX|DEF}]] ,( @ < scan_list >) :VOLTage:DC? [{< range >| AUTO |MIN| MAX|DEF} [,< resolution >|MIN|MAX|DEF}],] ( @ < scan_list >) :VOLTage:AC? [{< ...
-
Agilent Technologies 34970A - page 3
Scan Configuration Commands ( see page 226 in the User’s Gu ide ) ROUTe :SCAN ( @ < scan_list >) :SCAN? :SCAN:SIZE? TRIGger : SOU Rce {B U S | IMMediate |EXTernal|ALA Rm1|ALARm2|ALARm3|ALARm4 |TIMer} :SOURce? TRIGger :TIMer {< seconds >| MIN |MAX} :TIMer? TRIGger :COUNt {< count >| MIN |MAX|INFi nity} :COUNt? ROUTe :CHANnel:DELa ...
-
Agilent Technologies 34970A - page 4
Scanning With an External Instrument ( see page 239 in the User’s Gu ide ) ROUTe :SCAN ( @ < scan_list >) :SCAN? :SCAN:SIZE? TRIGger :SOURce {BUS|IMMediate|EXT ernal| TIMer } :SOURce? TRIGger :TIMer {< seconds >| MIN |MAX} :TIMer? TRIGger :COUNt {< count >|MIN|MAX| INFi nity } :COUNt? ROUTe :CHANnel:DELay < seconds >[,( @ ...
-
Agilent Technologies 34970A - page 5
Temperature Configuration Commands ( see page 219 in the User’s Gu ide ) CONFigure :TEMPerature { TCoupl e |RTD|FRTD|THERmis tor|DEF} ,{< type >|DEF}[,1[,{< resolution >|MIN|MAX|DEF}]] ,( @ < scan_list >) CONFigure? [( @ < ch_lis t >)] UNIT :TEMPerature { C |F|K}[,( @ < ch_list >)] :TEMPerature? [( @ < ch_list > ...
-
Agilent Technologies 34970A - page 6
Voltage Configuration Commands ( see page 223 in the User’s Gu ide ) CONFigure :VOLTage:DC [{< range >| AUTO |MIN|M AX|DEF} [,< resolution >|MIN|MAX|DEF}],] ( @ < scan_list >) CONFigure? [( @ < ch_lis t >)] [SENSe:] VOLTage:DC:RANGe {< range >|MIN|MAX}[, ( @ < ch_list >)] VOLTage:DC:RANGe? [{( @ < ch_list &g ...
-
Agilent Technologies 34970A - page 7
Resistance Configuration Commands ( see page 224 in the User’s Gu ide ) CONFigure :RESistance [{< range >| AUTO |MIN|M AX|DEF} [,< resolution >|MIN|MAX|DEF}],] ( @ < scan_list >) CONFigure? [( @ < ch_lis t >)] [SENSe:] RESistance:RANGe {< range >|MIN|MAX}[, ( @ < ch_list >)] RESistance:RANGe? [{( @ < ch_list ...
-
Agilent Technologies 34970A - page 8
Current Configuration Commands ( see page 224 in the User’s Gu ide ) Valid only on channels 21 and 22 on the 34901A mul tiplexer module. CONFigure :CURRent:DC [{< range >| AUTO |MIN|M AX|DEF} [,< resolution >|MIN|MAX|DEF}],] ( @ < scan_list >) CONFigure? [( @ < ch_lis t >)] [SENSe:] CURRent:DC:RANGe {< range >|MIN|MA ...
-
Agilent Technologies 34970A - page 9
Frequency a nd Period Configuration Commands ( see page 214 in the User’s Gu ide ) CONFigure :FREQuency [{< range >| AUTO |MIN|MA X|DEF} [,< resolution >|MIN|MAX|DEF}],] ( @ < scan_list >) CONFigure? [( @ < ch_lis t >)] [SENSe:] FREQuency:VOLTage:RANGe {< range >|MIN|MAX}[,( @ < ch_list >) ] FREQuency:VOLTage:R ...
-
Agilent Technologies 34970A - page 10
Mx+B Scalin g Commands ( see page 244 in the User’s Gu ide ) CALCulate :SCALe:GAIN < gain >[ ,( @ < ch_list >)] :SCALe:GAIN? [( @ < ch_list >)] :SCALe:OFFSet < offset >[,( @ < ch_list >)] :SCALe:OFFSet? [( @ < ch_list >)] :SCALe:UNIT < quot ed_ strin g >[,( @ < ch_ list >)] :SCALe:UNIT? [( @ < ch ...
-
Agilent Technologies 34970A - page 11
Digital Input Commands ( see page 255 in the User’s Gu ide ) Ch 01 DIO (L SB) Ch 0 2 DIO (MSB ) Ch 03 Totalizer Ch 04 DAC Ch 05 DAC CONFigure:DIGital:BYTE ( @ < scan_list >) CONFigure? [( @ < ch_lis t >)] [SENSe:]DIGital:DATA:{ BYT E |WORD}? [( @ < ch_lis t >)] Totalizer Commands ( see page 256 in the User’s Gu ide ) Ch 01 DIO ...
-
Agilent Technologies 34970A - page 12
Switch Control Commands ( see page 259 in the User’s Gu ide ) ROUTe :CLOSe ( @ < ch_list >) :CLOSe:EXCLusive ( @ < ch_list >) :CLOSe? ( @ < ch_lis t >) ROUTe :OPEN ( @ < ch_list >) :OPEN? ( @ < ch_list >) ROUTe:DONE? SYSTem:CPON {100|200|300|ALL } Scan Triggering Commands ( see page 228 in the User’s Gu ide ) TRIGg ...
-
Agilent Technologies 34970A - page 13
System-Related Commands ( see page 264 in the User’s Gu ide ) SYSTem :DATE < yyyy > , < mm > ,< dd > :DATE? :TIME < hh >,< mm >,< ss.sss > :TIME? FORMat :READing:TIME:TYPE {ABSolu te| RELative } :READing:TIME:TYPE? *IDN? SYSTem:CTYPe? {100|200|300} DIAGnostic :POKE:SLOT:DATA {100|200|3 00}, < quoted_string & ...
-
Agilent Technologies 34970A - page 14
Status System Commands ( see page 286 in the User’s Gu ide ) *STB? *SRE < enable _value > *SRE? STATus :QUEStionable:CONDition? :QUEStionable[:EVENt]? :QUEStionable:ENABle < ena ble_value > :QUEStionable:ENABle? *ESR? *ESE < enable _value > *ESE? STATus :ALARm:CONDition? :ALARm[:EVENt]? :ALARm:ENABle < en able_value > :ALA ...
-
Agilent Technologies 34970A - page 15
Service-Related Commands ( see page 294 in the User’s Gu ide ) INSTrument :DMM {OFF|ON} :DMM? :DMM:INSTalled? DIAGnostic :DMM:CYCLes? :DMM:CYCLes:CLEar (1|2|3} DIAGnostic :RELay:CYCLes? [( @ < ch_list >)] :RELay:CYCLes:CLEar [( @ < ch_list >)] *RST SYSTem:PRESet SYSTem:CPON {100|200|300|ALL } SYSTem:VERSion? *TST? IEEE 488.2 Co mmon C ...
-
Agilent Technologies 34970A - page 16
Agilent 34901A 20-Channel Multiplexer ( see page 164 in the User’s Gu ide ) Agilent 34902A 16-Channel Multiplexer ( see page 166 in the User’s Gu ide ) 16 ...
-
Agilent Technologies 34970A - page 17
Agilent 34903A 20-Channel Act uator ( see page 168 in the User’s Gu ide ) Agilent 34904A 4x8 Matrix ( see page 170 in the User’s Gu ide ) 17 ...
-
Agilent Technologies 34970A - page 18
Agilent 34905A/6A Dual 4- Channel RF Multiplexers ( see page 172 in the User’s Gu ide ) Agilent 34908A 40-Channel Single-Ended Mul tiplexer ( see page 174 in the User’s Gu ide ) 18 ...
-
Agilent Technologies 34970A - page 19
Agilent 34907A Mult ifunction Module ( see page 176 in the User’s Gu ide ) 19 ...
-
Agilent Technologies 34970A - page 20
Factory Reset State The table below shows the state of the instrument after a FACTORY RESET from the Sto/Rcl menu or *RST command from the remote interface. Measurement Configurati on Fu ncti on Range Res olu tio n Inte gration Time Input Re sistance Channel D elay Totalizer Rese t Mode Tota lize r Edge De tect Scanning Oper atio ns Scan L ist Read ...
Haben Sie eine Frage bezüglich Agilent Technologies 34970A?
Nutzen Sie das untere Formular
Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Agilent Technologies 34970A nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Agilent Technologies 34970A hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.