  • Invacare IRC5PAW - page 1

    Dealer: This manual MUST be given to the end user. User: BEFORE using this product, read this manual and save for future reference. Operator’s Manual For more information regarding Invacare products, parts, and services, please visit www.invacare.com Perfecto 2 ™ Series Oxygen Concentrators without SensO 2 ® , Oxygen Concentrators with SensO 2 ...

  • Invacare IRC5PAW - page 2

    WARNING Perfecto 2 ™Series 2 Part No 1150713  WARNING DO  NOT  use  this  product  or  any  av ailable  optional  equipment  without  first  completely  reading  and  understanding  these  instructions  and  any  additional  instructional  material  such  as  owner ’ ...

  • Invacare IRC5PAW - page 3

    TABLE OF CONTENTS Part No 1150713 3 Perfecto 2 ™Series ACCESSORIES .................................................. 2 SPECIAL NOTES ............................................... 4 LABEL LOCATION ............................................ 6 SECTION 1—GENERAL GUIDELINES ..................... 7 Radio Frequency Interference .. ............... ...

  • Invacare IRC5PAW - page 4

    SPECIAL NOTES Perfecto 2 ™Series 4 Part No 1150713 SPECIAL NOTES Signal  w ords  are  used  in  this  manual  and  apply  to  hazards  or  unsafe  practices  which  could  result  in  personal  injury  or  property  damage.  Refer  to  the  following  table  for ? ...

  • Invacare IRC5PAW - page 5

    SPECIAL NOTES Part No 1150713 5 Perfecto 2 ™Series CAUTION “Caution:  Statutory  law  can  restrict  this  device  to  sal e  by  or  on  order  of  a  physician,  or  any  other  practitioner  licens ed  by  the  law  of  the  governmental  agency  in  which ...

  • Invacare IRC5PAW - page 6

    LABEL LOCATION Perfecto 2 ™Series 6 Part No 1150713 LABEL LOCATION Serial Number Lab el is located on the resonator intake assembly Specification Label is located on the back near the bottom Perfecto 2 ™ FOR OPERATING INSTRUCTIONS or ALARMS (See Operator’s Manual) DANGER - RISK OF FIRE NO SMOKING - Keep ALL sources of ignition out of the room ...

  • Invacare IRC5PAW - page 7

    SECTION 1—GENERAL GUIDELINES Part No 1150713 7 Perfecto 2 ™Series SECTION 1—GENERAL GUIDELINES In  order  to  ensure  the  safe  installation,  assembly  and  operation  of  the  Pe r f e c t o 2  concentrator  these  instructions  MUST  be  followed.  WARNING This  section  conta ...

  • Invacare IRC5PAW - page 8

    SECTION 1—GENERAL GUIDELINES Perfecto 2 ™Series 8 Part No 1150713 Operating Information For  optimum  performance,  Inv acare  recommends  that  each  concentrator  be  on  and  running  for  a  minimum  of  30  minutes  at  a  time.  Shorter  periods  of  operation  may ...

  • Invacare IRC5PAW - page 9

    SECTION 1—GENERAL GUIDELINES Part No 1150713 9 Perfecto 2 ™Series Radio Frequency Interference This  equipmen t  has  been  tested  and  found  to  comply  with  EMC  limits  specified  by  IEC/EN  60601 ‐ 1 ‐ 2.  These  limits  are  designed  to  provide  a  reasonable ? ...

  • Invacare IRC5PAW - page 10

    SECTION 2—FEATURES Perfecto 2 ™Series 10 Part No 1150713 SECTION 2—FEATURES Oxygen Outlet Flowmeter Oxygen Purity Indicator Lights / Fault and Power Indicator Lights Power Switch Circuit Breaker Elapsed Time Meter Cabinet Filter REAR VIEW *HF Outlet Fitting Power Cord *NOTE:  This  outlet  fitting  is  to  be  used  on ...

  • Invacare IRC5PAW - page 11

    SECTION 3—HANDLING Part No 1150713 11 Perfecto 2 ™Serie s SECTION 3—HANDLING The  concentrator  should  AL W A YS  be  kept  in  the  upright  position  to  prevent  cabinet  damage  while  being  transported. If  the  concentrator  is  to  be  reshipped  by  common  c ...

  • Invacare IRC5PAW - page 12

    SECTION 4—TECHNICAL DESCRIPTION Perfecto 2 ™Series 12 Part No 1150713 SECTION 4—TECHNICAL DESCRIPTION The  Invacare  Per f e c t o 2  concentr ator  is  used  by  patients  with  respiratory  disorders  who  require  supplemental  oxygen.  The  device  is  not  intended  to  susta ...

  • Invacare IRC5PAW - page 13

    SECTION 5—TYPICAL PRODUCT PARAMETERS Part No 1150713 13 Perfecto 2 ™Serie s SECTION 5—TYPICAL PRODUCT PARAMETERS Alternating Current Type BF equipment Unit runnin g Unit not runnin g Attention - Consider Accompanying Documents DO NOT smoke Class II, Double Insulated Not Protected Electrical Requirements: 230 VAC ± 10% (253 VAC/20 7 VAC), 50 ...

  • Invacare IRC5PAW - page 14

    SECTION 5—TYPICAL PRODUCT PARAMETERS Perfecto 2 ™Series 14 Part No 1150713 Flow Range: 0.5 to 5 L/min (maximum ). For flowrates less than 1 L/min, we recommend th e use of the Invacare Pediatric Flowmeter Accessory (IRCPF16AW). Low Flow Alarm: 0 L/min to 0.5 L/min Rapid Audible Alarm Beeping (No Accessories Connected). Average Power Consumption ...

  • Invacare IRC5PAW - page 15

    SECTION 5—TYPICAL PRODUCT PARAMETERS Part No 1150713 15 Perfecto 2 ™Serie s No AP/APG Not suitable for use in the presence of a flammable anaesthetic mixture. Standards and Regulatory Listing: IRC5PO2AW/IRC5PAW IEC/EN61000-3-2 IEC/EN61000-3-3, IEC/EN 60601-1 , A1, A2 IEC/EN 60601-1 -2 IRC5PO2AW Models Only ISO8359 MDD 93/42/EEC, Annex I and IX ...

  • Invacare IRC5PAW - page 16

    SECTION 5—TYPICAL PRODUCT PARAMETERS Perfecto 2 ™Series 16 Part No 1150713 IRC5PO2AW INDICATORS IRC5PAW INDI CATORS LABEL SYMBOL O 2 PURITY INDICATOR LIGHTS (LED) SYSTEM OKAY O 2 over 85% (± 2%) GREEN Indicator Light O 2 Between 73% (± 3%) to 85% (±2%) YELLOW Indicator light A. YELLOW Solid B. YELLOW Flashing Sensor Failure Call a qualif ied ...

  • Invacare IRC5PAW - page 17

    SECTION 6—OPERATING INSTRUCTIONS Part No 1150713 17 Perfecto 2 ™Serie s SECTION 6— OPERATING INSTRUCTIONS Introduction Yo u r  oxygen  concentrator  is  intended  for  individual  use.  It  is  an  electronically  operated  device  that  separates  oxygen  from  room  air .  It  p ...

  • Invacare IRC5PAW - page 18

    SECTION 6—OPERATING INSTRUCTIONS Perfecto 2 ™Series 18 Part No 1150713 Yo u r  oxygen  concentrator  will  perform  best  when  operated  under  the  conditions  outlined  in  the  Ty p i c a l  Product  P arameters  on  page 13.  Usage  in  environments  other  than  those ...

  • Invacare IRC5PAW - page 19

    SECTION 6—OPERATING INSTRUCTIONS Part No 1150713 19 Perfecto 2 ™Serie s 3. Insert  a  flathead  screwdriver  in  the  plate  groove  on  the  top  edge  of  the  filter  access  door  and  gently  pry  the  filter  access  door  off  (FIGURE  6.2). 4. Pull  up  ...

  • Invacare IRC5PAW - page 20

    SECTION 6—OPERATING INSTRUCTIONS Perfecto 2 ™Series 20 Part No 1150713 10. After  assembly ,  ensure  that  oxygen  is  flowing  through  the  cannula. FIGURE 6.3 Humidifier Compartmen t Power Switch NOTE:  For  this  pr ocedure,  refe r  to  FIGURE  6.4. 1. Press  power  switch  to  O ...

  • Invacare IRC5PAW - page 21

    SECTION 6—OPERATING INSTRUCTIONS Part No 1150713 21 Perfecto 2 ™Serie s Flowrate NOTE:  For  this  procedure,  refe r  to  FIGURE  6.5. NOTE:  Ta k e  care  not  to  set  the  flow  above  RED  ring.  An  oxygen  flow  gr eater  than  5  L/min  will  decr ease  the ...

  • Invacare IRC5PAW - page 22

    SECTION 6—OPERATING INSTRUCTIONS Perfecto 2 ™Series 22 Part No 1150713 SensO 2 Oxygen Purity Indicator - Model IRC5PO2AW This  feature  monitors  the  purity  of  oxygen  generated  by  the  oxygen  concentrator .  If  purity  falls  below  factory  preset  standards,  indicator  light ...

  • Invacare IRC5PAW - page 23

    SECTION 6—OPERATING INSTRUCTIONS Part No 1150713 23 Perfecto 2 ™Serie s FIGURE 6.6 Explanation of Oxygen Purity Indicator Lights - Model IRC5PO2AW Explanation of Indicator Lights - Model IRC5PAW NOTE:  For  this  procedure,  refe r  to  FIGURE  6.7. IRC5PAW Model Indicator Light Explanation RED  light  () ‐  T ...

  • Invacare IRC5PAW - page 24

    SECTION 7—MAINTENANCE Perfecto 2 ™Series 24 Part No 1150713 SECTION 7—MAINTENANCE  WARNING The  Invacare  concentrators  are  specifically  designed  to  minimize  routine  preventiv e  mainte nance.  Only  qualified  personnel  should  perform  preventiv e  maintenance  on  the  ...

  • Invacare IRC5PAW - page 25

    SECTION 7—MAINTENANCE Part No 1150713 25 Perfecto 2 ™Serie s 2. Clean  the  cabinet  filter  with  a  va c u u m  cleaner  or  wa s h  in  w arm  soapy  wa t e r  and  rinse  thoroughly . 3. Dry  the  filter  thoroughly  before  reinstallation. FIGURE 7.1 Cleaning the Cabinet Filter ...

  • Invacare IRC5PAW - page 26

    SECTION 7—MAINTENANCE Perfecto 2 ™Series 26 Part No 1150713 PREVENTIVE MAINTENANCE RECORD Model  No.  IRC  ______________  Serial  No.________________ On  Each  Inspection *NOTE:  Refer  to  Preventive  Ma intenance  section  of  Service  Manual. **NOTE:  Model  not  available  within  ...

  • Invacare IRC5PAW - page 27

    SECTION 8—TROUBLESHOOTING GUIDE Part No 1150713 27 Perfecto 2 ™Serie s SECTION 8—TROUBLESHOOTING GUIDE SYMPTOM: PROBABLE CAUSE: SOLUTION: Alarm: Main Power Loss: Short beeps, long pause 1. Power cord not plugged in. 1. Insert plug in to outlet. Concentrator not operating, power switch On. 2. No power at outlet. 2 . Inspect house circuit break ...

  • Invacare IRC5PAW - page 28

    SECTION 8—TROUBLESHOOTING GUIDE Perfecto 2 ™Series 28 Part No 1150713 YELLOW or RED light Illuminated. Alarm: Continuo us On RED light only. * Only applies to IRC5PO2AW models. 1. Low oxygen purity.* 1. Clean or Replace filters. 2. Kinked or blocked tubing, cannula or humidifier.* 2. Inspect for kinks or blockages. Correct, clean or replace ite ...

  • Invacare IRC5PAW - page 29

    SECTION 9—OPTIONAL ACCESSORIES Part No 1150713 29 Perfecto 2 ™Serie s SECTION 9—OPTIONAL ACCESSORIES The  following  optional  accessories  are  also  av ailable:  • Standard  Adult  Nasal  Cannula,  2.1  m  (7  feet) ‐ M3120 • Standard  Humidifier ‐ M5120 • PreciseRX™  P ed ...

  • Invacare IRC5PAW - page 30

    RECYCLING INFORMATION Perfecto 2 ™Series 30 Part No 1150713 RECYCLING INFORMATION This  product  has  been  supplied  from  an  environmentally  aw are  manufacturer  that  complies  with  the  Wa s t e  Electrical  and  Electronic  Equipment  (WEEE)  Directive  2002/96/CE. This  p ...

  • Invacare IRC5PAW - page 31

    LIMITED WARRANTY Part No 1150713 31 Perfecto 2 ™Serie s LIMITED WARRANTY United  Kingdom:  Invacare  Ltd,  South  Road,  Bridgend  Industrial  Estate,  UK ‐ Bridge nd  CF31  3PY Te l :  (44)  (0)1656  664  321,  Fax:  (44)  (0)1656  667  532 UK@inv acare.com  Ireland: Inv acare  ...

  • Invacare IRC5PAW - page 32

    0120 Invacare Corporation www.invacare.com USA One Invacare Way Elyria, Ohio USA 44036-2125 440-329-6000 800-333-6900 Technical Services 440-329-6593 800-832-4707 EU Representative Invacare International Sarl Route de Cité Ouest 2 1196 Gland Switzerland Tel: +41 22 354 60 10 Fax: +41 22 354 60 11 Part No 1150713 Invacare Corporation 2101 E. Lake M ...

Produzent Invacare Kategorie Oxygen Equipment

Dokumente, die wir vom Produzenten des Geräts Invacare IRC5PAW erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Invacare
- Bedienungsanleitungen IRC5PAW
- Produktkarten Invacare
- Informationsbroschüren
- oder Energieetiketten Invacare IRC5PAW
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Invacare IRC5PAW.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Invacare IRC5PAW, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Invacare IRC5PAW. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Invacare IRC5PAW ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Invacare IRC5PAW, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Invacare IRC5PAW hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Invacare IRC5PAW verständlich ist.

Eine gänzliche Bedienungsanleitung von Invacare sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Invacare IRC5PAW bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Invacare IRC5PAW befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Invacare IRC5PAW, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Invacare IRC5PAW - die uns die ersten Schritte während der Nutzung von Invacare IRC5PAW erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Invacare IRC5PAW hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Invacare IRC5PAW im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Invacare IRC5PAW?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Invacare IRC5PAW nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Invacare IRC5PAW hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)