MRV Communications EM316E1 - page 1
EM316 T 1 EM316 E 1 Fiber Driver Modem User’s Guide ...
-
MRV Communications EM316E1 - page 2
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PA GE 2 Registration Card Your name: Mr./Ms____________ _______________________________ Organization: _________________ _______Dept. __________________ Your title at organization:__ __________________ __________________ Telephone: _____________ ______________ Fax:__________________ Organization&a ...
-
MRV Communications EM316E1 - page 3
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PA GE 3 EM316E1 EM316T1 Fiber Driver Modem User’s Guide ...
-
MRV Communications EM316E1 - page 4
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PA GE 4 TABLE OF CONTENTS 1 INTRODUCTION 2 HARDWARE INSTALLATION 3 TROUBLESHOOTING 4 TECHNICAL SPECIFICATIONS 5 CONTACT INFORMATION 6 GLOSSARY 7 ORDERING INFORMATION ...
-
MRV Communications EM316E1 - page 5
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PA GE 5 1 INTRODUCTION About this Manual Before unpacking please refer to section 2 (Hardware Installation) This manual is a guide to the installa tion and operation of the EM316E1/T1 Fiber Modem. Product description describes the product, it s functions, features, protocol supported, minimum req ...
-
MRV Communications EM316E1 - page 6
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PA GE 6 Features • Modules can be Inserted / Removed without powering off the chassis • Extensive Network Management Support when used with EM316NM • Provide Fiber Link for T1(ANSI T 1.403) or E1 (G.703) Applications • Built-in Elastic Buffer to Remove Jitter • LED Indicators to help Tr ...
-
MRV Communications EM316E1 - page 7
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PA GE 7 Connectivity Connectors Used Fiber: ST, or SC-APC (for single fiber) UTP: RJ48-MDI Coax: BNC (2 connectors: 1 for TX, 1 for RX) Cable Requirement Fiber: ST-ST fiber cable, or SC-APC fiber cable (for single fiber) UTP: Category 5 Coax: RG58/U Port Description Input: E1 (BNC) or T1 (UTP-RJ4 ...
-
MRV Communications EM316E1 - page 8
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PA GE 8 Display Information (LED Definition) • PWR/NMS: illuminates when unit is powered (green colo r), flashes (green color) when remote or local loop back is enabled by management. The remote loop back feature provid es a quick check of the basic functionality of both modem s and both fiber ...
-
MRV Communications EM316E1 - page 9
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PA GE 9 Typical Applications EM316E1/T1 (Fiber Modem) ...
-
MRV Communications EM316E1 - page 10
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 10 Configuration Jumper Settings: (Factory Default) DO NOT CHANGE THE JUMPER SETTINGS BELOW JUMPER SETTINGS RESULTS JP2 OPEN Factory Use Only JP9 OPEN Factory Use Only W1 OPEN Factory Use Only Note: * Jum per settings with asterisk (*) are factory default ...
-
MRV Communications EM316E1 - page 11
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 11 EM316E1 Jumper Settings for E1 120 Ω Application : 1) Install jumpers between JP3 pins 1 and 2, 2) No jumpers on JP4 and JP5 open, (all pi ns are open) 3) Set all switches on S1 to ON. (BIT2=ON, BIT1=ON, BIT0=ON), for E1 and choose HDB3 as encoder & decoder testing mode 2 4 1 3 JP3 ...
-
MRV Communications EM316E1 - page 12
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 12 EM316E1 Jumper Settings for E1 75 Ω Application : 1) Install jumpers between JP3 pins 3 and 4, 2) Install jumpers between JP4 pi ns 1 and 2, JP5 pins 1 and 2 3) Set all switches on S1 to ON. (BIT2=ON, BIT1=ON, BIT0=ON), for E1 and choose HDB3 as encoder & decoder testing mode 2 4 1 ...
-
MRV Communications EM316E1 - page 13
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 13 EM316T1 Jumper Settings for T1 100 Ω Application : 1.) Install jumpers between JP3 pins 1 and 2, 2.) No jumpers on JP4 and JP5 open, (all pi ns are open, no headers, not used) 3) Set RECEIVED CODE and TRANSMIT CODE on S1 to ON. (Choose B8ZS as encoder & decoder testing mode) 4) Set ...
-
MRV Communications EM316E1 - page 14
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 14 Theory of Operation Data encoding used on the EM316E1/T1 Fiber Modem consists of converting the incoming AMI B8ZS or HDB3 to a format suitable for fiber optic communication. A proprietary coding scheme is used which combines the input clock and data into a composite signal that is then tr ...
-
MRV Communications EM316E1 - page 15
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 15 2 HARDWARE INSTALLATION PREP ARA TION STEP 1 Follow all Safety Regulations 1 Eliminate static electricity in the workplace by grounding operators, equipment, and devices (components and computer boards). Groundi ng prevents static charge buildup and electrostatic potential differenc es. T ...
-
MRV Communications EM316E1 - page 16
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 16 f) ESD protective floor or mat: The mat must be grounded through a current- limiting resistor. The floor or mat dissip ates the static charge of personnel approaching the workbench. Special conduc tive tile or floor treatment can be used when mats are not practical or cause a safety hazar ...
-
MRV Communications EM316E1 - page 17
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 17 UNIT INSTALLATION STEP 1 Remove required amount of bla nk panels from the NC316BU-xx. NOTE : Per FCC regulations, either a panel or a module should always cover chassis slots. FIGURE 1.1 Take out the required amount of blank panels. STEP 2 Align the edges of the EM316 module to the rail i ...
-
MRV Communications EM316E1 - page 18
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 18 STEP 3 Insert the module into the NC316BU-xx unit NOTE: To avoid damaging any components on the m odule, handle it by the edges, using your thumb to push it securely inside the ch assis. Do not use excessive force, but make sure the module is fully inserted in the chassis. W hen the modul ...
-
MRV Communications EM316E1 - page 19
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 19 3 TROUBLESHOOTING The Fiber Driver series are highly reliable units. If there are any operating problems, the fault probably lies in some other aspect of the configuration. However, if after following the troubl eshooting steps below (in order), you find that the unit is still not functio ...
-
MRV Communications EM316E1 - page 20
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 20 4 TECHNICAL SPECIFICATIONS Electrical 5VDC @ 2 Amps Max Hot Swappable Operating Temperature Range 0 ° C - +50 ° C (32 ° F – 122 ° F) Storage temp -10 ° C - +60 ° C (14 ° F – 140 ° F) Relative Humidity 85% maximum non-condensing Emissions Compliance FCC Part 15, Subpart B, 1999 ...
-
MRV Communications EM316E1 - page 21
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 21 5 CUSTOMER SUPPORT Contact Information If you have any questions, please do not hesitate to contact us at: Americas Support MRV (East Coast USA) 295 Foster Street Littleton, MA 01460-2016 Tech Support: (800) 338-5316 Tech Support: (978) 952-4700 E-mail: support@fiberdriver.com Fax: (978) ...
-
MRV Communications EM316E1 - page 22
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 22 5 GLOSSARY Complete definition of networking term s (jargon) used in this manual, may be found on our ftp site: ftp://ftp.fiberdriver.com/pub/doc/Glossary.pdf 6 ORDERING INFORMATION Please visit us at http://www.fiberdriver.com for the latest updates on our products. Fiber Driver Division ...
-
MRV Communications EM316E1 - page 23
Fiber Driver EM316E1/EM316T1 P/N: 1218003-001, REV_O PAGE 23 Place Stamp Here ---------- ---------------- ------------------ ---- ---------- ---------------- ------------------ ---- ---------- ---------------- ------------------ ---- 8928 Fullbright Avenue Chatsworth, California 91311 U . S . A . ...
Haben Sie eine Frage bezüglich MRV Communications EM316E1?
Nutzen Sie das untere Formular
Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit MRV Communications EM316E1 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit MRV Communications EM316E1 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.