Bedienungsanleitung Telenetics 14.4

31 Seiten 0.38 mb
Download

Zur Seite of 31

Summary
  • Telenetics 14.4 - page 1

    Installation, Operation & Diagnostics for the MIU/PowerPort Series / 2.4 / 9.6 / 14.4 / 28.8 Industrial Grade Dial Modems Book 1 of 2 (See Book 2 for AT Commands) Document No. 49-0002-002 ...

  • Telenetics 14.4 - page 2

    Telenetics Corporation 26772 Vista Terrace Drive Lake Forest, California 92630 Telephone (949)455-4000 Fax (949)455-4010 Document No. 49-0002-002 ...

  • Telenetics 14.4 - page 3

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 1 TABLE of CONTENTS 1. STANDARDS .................................................................................... Page 2 2. PRODUCT OVERVIEW ................................................................... Page 3 3. GENERAL PRODUCT SPECIFICATIONS ................... ...

  • Telenetics 14.4 - page 4

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 2 1. STANDARDS All Telenetics di al-up modem s are designed to meet the following Standards: USA: FCC Part 15, Class A and Part 68 Canada: DOC Standards CS-01, CS-02 and CS -03 CANADIAN DEPARTMENT OF COMMUNICATION NOTICE NOTICE: The Canadian Departm ent of Comm unicati ons ...

  • Telenetics 14.4 - page 5

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 3 2. PRODUCT OVERVIEW The MIUPowerPortX.X Series are i ndustrial grade dial and leased line modem s for connection to the Public Swit ched Telephone Network.. They can be powered from a wide range of AC and DC power suppl ies, they are internally surge protected on both th ...

  • Telenetics 14.4 - page 6

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 4 Industrial: The MIU PowerPort is packaged in a rugged, compact, non-metallic (ABS) enclosure. Designed for unmanned locations, t he MIUs do not include the array of pushbuttons and LEDs norm ally associ ated with consumer-type modems to increase reliability and decrease ...

  • Telenetics 14.4 - page 7

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 5 3. GENERAL PRODUCT SPECIFICATIONS Dimensi ons: 5.3 x 4.0 x 1.375 inches Weight: 1 lb Voltage Supply: : 8 to 24 VDC 7 to 16 VAC, 50/60 Hz Optional Wall Transform er 115 VAC, 50/60 Hz Current Requirem ents: (See Section 4 for Power Down M odes) MIU PowerPort 2.4: 12VDC 24V ...

  • Telenetics 14.4 - page 8

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 6 4. POWER MODES Mode Description Power Consumption Power On Factory Setting : Full power is always available to the modem. See Section 3 Sleep If the modem is on hook for a predetermined peri od (PE2400 = 5 seconds; PE2496, PE14.4 & PE28.8 = software configured: Set S ...

  • Telenetics 14.4 - page 9

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 7 5. MODEM SPECIFICATIONS MIU2.4 MIU9.6 MIU14.4 MIU28.8 Standards V.22bis V.22 Bell212A Bell 103 V.22bis V.22 Bell212A Bell 103 V.32bis V.32 V.22bis V.22 Bell212A Bell 103 V.34 V.32bis V.32 V.22bis V.22 Bell212A Bell 103 Modem Line Speed (Asynch) 2400bps 1200bps 300bps 240 ...

  • Telenetics 14.4 - page 10

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 8 6. POWER CONNECTIONS DC Power Jack, 2.0mm – This standard concentri c jack is provided to attach an external power source in the range of 7 – 16 VAC or 8 – 24 VDC . The 2.0mm Jack connects through a full wave bridge so either polarity is acceptable from the DC sour ...

  • Telenetics 14.4 - page 11

    7. SERIAL DATA PORT PIN-OUTS MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 9 ...

  • Telenetics 14.4 - page 12

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 10 8. DIP SWITCH SETTINGS Not Applicable – The dip switches are on the PE Modul e. Contact factory for non – standard settings. * NOTE: Opening the MIU for any reason voids t he factory warranty. ...

  • Telenetics 14.4 - page 13

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 11 9. LED INDICATOR The MIU has a single LED that w ill indicate the following conditions... 4 Blinking: POWER ON 4 Steady: MODEM CONNECTED (CARRIER DETECT) 10. AUTO RESET FEATURE The dial-up m odem m odules inside your MIU include an “Aut o Reset” feature: If the mode ...

  • Telenetics 14.4 - page 14

    12. OUTLINE DRAWING & MOUNTING MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 12 ...

  • Telenetics 14.4 - page 15

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 13 13. MODEM CONFIGURATION Telenetics dial and leased l ine modems are based upon Rockwell chipsets. These chipsets contain Rockwell’s “AT” comma nd set. A summary of the Rockwell comm and set for your MIU m odem is provided in Book 2. Unless otherwise specified at t ...

  • Telenetics 14.4 - page 16

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 14 14. FACTORY CONFIGURATION ~ MIU2.4 ACTIVE PROFILE: B1 E1 L2 M1 Q0 V1 X4 Y0 &C1 &D0 &G0 &J0 &L0 &P0 &Q0 &R0 &S0 &X0 &Y0 S00:001 S01:000 S02:043 S03: 013 S04:010 S05:008 S06:002 S07:030 S08:002 S09: 006 S10:014 S12:050 S14:AAH S ...

  • Telenetics 14.4 - page 17

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 15 14. FACTORY CONFIGURATION ~ MIU9.6 ACTIVE PROFILE: B1 E1 L1 M1 N1 Q0 T V1 W0 X4 Y0 &C1 &D2 &G0 &J0 &K3 &Q5 &R1 &S0 &T5 &X0 &Y0 S00:001 S01:000 S02:043 S03: 013 S04:010 S05:008 S06:002 S07:050 S08: 002 S09:006 S10:014 S11:095 S ...

  • Telenetics 14.4 - page 18

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 16 14. FACTORY CONFIGURATION ~ MIU14.4 ACTIVE PROFILE: B1 E1 L1 M1 N1 Q0 T V1 W0 X4 Y0 &C1 &D2 &G0 &J0 &K3 &Q5 &R1 &S0 &T5 &X0 &Y0 S00:001 S01:000 S02:043 S03: 013 S04:010 S05:008 S06:002 S07:050 S08: 002 S09:006 S10:014 S11:095 ...

  • Telenetics 14.4 - page 19

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 17 14. FACTORY CONFIGURATION ~ MIU28.8 ACTIVE PROFILE: B0 E1 L1 M1 N1 Q0 T V1 W0 X4 Y0 &C1 &D0 &G2 &J0 &K3 &Q5 &R1 &S0 &T4 &X0 &Y0 S00:001 S01:000 S02:043 S03: 013 S04:010 S05:008 S06:002 S07:030 S08: 002 S09:006 S10:014 S11:255 ...

  • Telenetics 14.4 - page 20

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 18 15. DIAGNOSTICS The following pages provide softwa re and hardware t echniques for diagnosing comm unication problem s and thereby isol ating the problem at either the local modem, the remote modem or the interconnecting lin e. The following AT&Tn comm ands form par ...

  • Telenetics 14.4 - page 21

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 19 &T0 TERMINATE TEST IN PROGRESS If a V.54 loopback test is in progress as a resul t of executing an &Tn command, then the &T0 command will cause that test to be terminated, provided that the modem is in the comm and state or a V.54 state that accepts comma nd ...

  • Telenetics 14.4 - page 22

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 20 &T2 NO FUNCTION &T3 PERFORM LOCAL DIGITAL LOOPBACK (See Figure 3) The modem must be in the comm and state with connection est ablished when this command is issued, otherw ise an ERROR result code occurs. The AT&T3 command establishes a loopback of received d ...

  • Telenetics 14.4 - page 23

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 21 &T5 DENY RDL REQUESTS The modem will not respond to a rem o te digital loopback request from a distant modem. This will result in an error if the command is given wh ile any V.54 test is acti ve (&T1, &T3, &T6, &T7 or &T8). &T6 INITIATE REMOT ...

  • Telenetics 14.4 - page 24

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 22 This is a system test, end to end. The comm and is valid only i f the mode m s are in the comm and state with a connection established. Configure th e remote modem with an AT&T4 comm and so that it will honor a remote digi tal loopback request. Enter AT&T7 at th ...

  • Telenetics 14.4 - page 25

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 23 &T8 LOCAL LOOPBACK WITH SELF TEST (See Figure 6) The modem should be on hook. Enter AT&T8 to configure the m odem for analog loopback and self test. The t est timer i s started at the ti me indicated by S18, DSR i s turned off (i f &S1 is in effect). A self ...

  • Telenetics 14.4 - page 26

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 24 ...

  • Telenetics 14.4 - page 27

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 25 ...

  • Telenetics 14.4 - page 28

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 26 ...

  • Telenetics 14.4 - page 29

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 27 ADDITIONAL TEST / DIAGNOSTICS COMMANDS... %L RECEIVED SIGNAL LEVEL Returns a value (-dBm) which indicates the received signal level at modem DATA PUMP interface. This value is determined by the loss/gain of m odem Telco Interface circuit ±dB at the Tip/R ing input to t ...

  • Telenetics 14.4 - page 30

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 28 0 Normal hang up; no error occurred. 4 Physical carrier loss. (Loss of Carrier) 5 Feature negotiation fai led to detect presence of another V.42 error-control modem at other end. 6 Other error-control m odem did not respond to feature negotiation m essage sent by this m ...

  • Telenetics 14.4 - page 31

    MIU Installation, Operation & Diagnostics Edition: January 25, 1999 Page 29 NOTES: ...

Produzent Telenetics Kategorie Network Card

Dokumente, die wir vom Produzenten des Geräts Telenetics 14.4 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Telenetics
- Bedienungsanleitungen 14.4
- Produktkarten Telenetics
- Informationsbroschüren
- oder Energieetiketten Telenetics 14.4
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Telenetics 14.4.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Telenetics 14.4, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Telenetics 14.4. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Telenetics 14.4 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Telenetics 14.4, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Telenetics 14.4 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Telenetics 14.4 verständlich ist.

Eine gänzliche Bedienungsanleitung von Telenetics sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Telenetics 14.4 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Telenetics 14.4 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Telenetics 14.4, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Telenetics 14.4 - die uns die ersten Schritte während der Nutzung von Telenetics 14.4 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Telenetics 14.4 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Telenetics 14.4 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Telenetics 14.4?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Telenetics 14.4 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Telenetics 14.4 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)