    ADX-2400D AUDIO DISTRIBUTION AND DELAY SYSTEM (AES Digital I/O) Installation and Operation Manual Softw are Version 1.3 October, 2007 Lance Design / 27 Fairview Avenue / Ridgefield, Connecticut 06877 Tel: 203-894-8206 / Fax: 203-894-8207 ww w.lanced esign.com ...

  • Lance Industries ADX-2400D - page 2

    2 CA UTION! HA ZA RDOUS VOLTA GES A RE EXPOSED WHEN THE TOP COVER OF THE RA CK FRA ME IS REMOVED. DO NOT A PPLY POWER WITH THE UNIT DISASSEMBLED. W ARRANTY STATEMENT This equipment is warranted to be free of defects in materials and workmanship for a period of two years from date of deliv ery. Any necessary repairs resulting from defects in materia ...

  • Lance Industries ADX-2400D - page 3

    3 Table of Contents Quick Operation Guide Page 4 Menu Items Page 5 Saving and Recalling Configurations Page 8 Locking Setups and Menus [options dipswitch] Page 8 General Operation Page 9 Audio Netw ork Page 10 Designing the Network [Im portant Inf ormation] Page 12 Installation Page 15 Specifications Page 16 Front Panel View Rear Panel View ...

  • Lance Industries ADX-2400D - page 4

    4 QUICK OPERA TION GUIDE  To Select Output Channel (or Channels) to A djust Press ‘OUTPUT SELECT’ button, and turn knob until desired channel is selected. The order of the channel selection is as follows: Local (AES) Output 1 through 24 (Individual Outputs) Local Outputs 1-8 (Group) Local Outputs 9-16 (Group) Local Outputs 17-24 (Group) A ll ...

  • Lance Industries ADX-2400D - page 5

    5  To A djust Level (for current output or gr oup of outputs) The output level can be adjusted in 0.25 dB increments. Maximum gain is +12 dB. To adjust, press the 'LEVEL' butt on, and turn the knob.  To A djust Delay (f or current output or gr oup of output s) The delay of each output can be independently adjusted from zero delay th ...

  • Lance Industries ADX-2400D - page 6

    6 Item 04 – TX 1-8 Bundle (000-999) Packet assignment for network transmitter 1, which corresponds to audio outputs NET 01 – NET 08. Item 05 – TX 9-16 Bundle (000-999) Packet assignment for network transmitter 2, which corresponds to audio outputs NET 09-NET 16. Item 06 – TX 17-24 Bundle (000-999) Packet assignment for network transmitter 3 ...

  • Lance Industries ADX-2400D - page 7

    7 Item 11 - <Set> to Recall Config Pressing the 'MENU SET' button will recall the conf iguration stored in the f ile selected in menu item 09 above. The following items are STATUS items, and are only to display status information. They may not be changed by the user. Status Item 01 – NET RX 1 Status (Active or Idle) Display s ACTI ...

  • Lance Industries ADX-2400D - page 8

    8 Status Item 05 – NET TX 2 Status (Idle or Number of Receivers) Same as above for net outputs 9-16. Status Item 06 – NET TX 3 Status (Idle or Number of Receivers) Same as above for net outputs 17-24. Status Item 07 – Conductor Status (Another Unit or This Unit) Indicates if t he network conductor ('sync generator') is this unit or ...

  • Lance Industries ADX-2400D - page 9

    9 Saving and Recalling Configurations The m enu settings and the source, level, and delay settings are stored automatically after 20 seconds of panel inactivity in a 'default' flash memory. This is the memory which is restored automatically when the unit is first powered up. You may also save configurat ions in three user memories. First ...

  • Lance Industries ADX-2400D - page 10

    10 General Operational Notes The ADX-2400 is designed to provide delay, level control and distribution for eff ects or commentary audio. The system can be used for stand-alone delay of 24 AES audio channels (12 pairs), or can be used to t ransmit and receive audio signals via a standard Ethernet data network (24 transmit and 24 receive channels sim ...

  • Lance Industries ADX-2400D - page 11

    11 The Ethernet Part The Ethernet transmission uses the Cirrus Audio 'Cobranet' system, which is an industry standard. It is a professional, highly-reliabl e system which packs audio data into 'bundles' of 8 channels. The bundles are given numbers from 1 to 999. The first 255 are 'broadcast' bundles which can be receiv ...

  • Lance Industries ADX-2400D - page 12

    12 Setting Bundle Numbers The 24 transmit and 24 receive audio channels in the ADX are divi ded into 8- channel groups. These groups are assigned to network channels or 'bundles'. There are six bundles per ADX unit, three for receive and three f or t ransmit. Each of these bundles can be assigned a three-digit number from 000 – 999. (No ...

  • Lance Industries ADX-2400D - page 13

    13  Exceedi ng this bandwidth limit will cause dropouts in the audio, and in severe cases may cause other problems such as sync and control problems.  An Ethernet switch, which g enerally forms the hub of a network, can partition the traffic so that bundles only go the receivers which are listening to them. Since each ADX frame only has three ...

  • Lance Industries ADX-2400D - page 14

    14 Cobranet 'Discovery ' PC A pplication Cirrus Logic, the developers of Cobranet, make available on their website a nice PC application called 'Cobranet Discovery', or 'Disco'. It can be downloaded and installed on any PC running W indows XP. It allow s the computer to be attached to the audio network and provides a v ...

  • Lance Industries ADX-2400D - page 15

    15 Installation The ADX-2400D is designed to be installed in a standard 19" equipment rack. There is a cooling fan on the rear panel which draws air in through the sides of the cabinet and exhausts hot air through the rear panel. T he unit should not be installed in such a way as to block the vents on the side panels, or air f low fr om the re ...

  • Lance Industries ADX-2400D - page 16

    16 A DX-2400D Specifications Local Input Channels 24 AES on 12 unbalanced (BNC fem ale) connectors, 1v p-p Local Output Channels 24 AES on 12 unbalanced (BNC fem ale) connectors, 1v p-p AES Reference Input AES Silence or other AES signal. BNC connector, 75-ohm, 1v p-p Output Phase Lock Accuracy +/- 1% of sample period ( +/- 200 ns) Input Phase Requ ...

Produzent Lance Industries Kategorie Stereo System

Dokumente, die wir vom Produzenten des Geräts Lance Industries ADX-2400D erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Lance Industries
- Bedienungsanleitungen ADX-2400D
- Produktkarten Lance Industries
- Informationsbroschüren
- oder Energieetiketten Lance Industries ADX-2400D
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Lance Industries ADX-2400D.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Lance Industries ADX-2400D, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Lance Industries ADX-2400D. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Lance Industries ADX-2400D ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Lance Industries ADX-2400D, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Lance Industries ADX-2400D hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Lance Industries ADX-2400D verständlich ist.

Eine gänzliche Bedienungsanleitung von Lance Industries sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Lance Industries ADX-2400D bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Lance Industries ADX-2400D befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Lance Industries ADX-2400D, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Lance Industries ADX-2400D - die uns die ersten Schritte während der Nutzung von Lance Industries ADX-2400D erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Lance Industries ADX-2400D hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Lance Industries ADX-2400D im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Lance Industries ADX-2400D?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Lance Industries ADX-2400D nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Lance Industries ADX-2400D hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)