    292043-UIM-B-0707 SINGLE PIECE AIR HANDLERS MODELS: F*FP INSTALLATION MANUAL ISO 9001 Certified Quality Management System SAFETY This is a safety alert symbol . When you see this symbol on labels or in manuals, be alert to the potential for personal injury . Understand and pay particular attention to the signal words D ANGER , WA R N I N G , or CAU ...

  • Coleman F*FP - page 2

    292043-UIM-B-0707 2 Unitary Products Group SPECIFIC SAFETY RULES AND PRE CA U TIONS 1. Install this air handler only in a location and position as specified in SECTION I of these instructions. 2. Always install the air handler to operate within the air handler ’s intended maximum outlet air t emperature. Only connect the air handler to a duct sys ...

  • Coleman F*FP - page 3

    292043-UIM-B-0707 Unitary Products Group 3 6. When an evaporator coil is instal led in an attic or above a finished ceiling, an auxiliary dr ain pan should be provided under the coil as is specified by most local building codes. 7. Proper electrical supply must be available. 8. Clearances must also be taken in to consideration, and provided for as ...

  • Coleman F*FP - page 4

    292043-UIM-B-0707 4 Unitary Products Group FIGURE 3: Filter Access & Drain Pan Conversion / Coil Baffle FIL TER 4B - SIDE VIEW "S" BRACKET MUST BE USED TO F ASTEN DUCT WORK T O FRONT OF UNIT RETURN AIR DUCT 3/4" PVC SOCKETS FOR HORIZONT AL DRAIN APPLICA TION HORIZONT AL DRAIN P AN POSITION "A” HORIZONT AL DRAIN P AN POSITI ...

  • Coleman F*FP - page 5

    292043-UIM-B-0707 Unitary Products Group 5 DUCT CONNECTIONS NOTE: The electric heat accessory s hould be installed before the sup- ply air duct is attached to the suppl y air openings. Refer to the electric heater kit instructions for proper installation. Air supply and return may be handled in one of several ways best suited to the installation. S ...

  • Coleman F*FP - page 6

    292043-UIM-B-0707 6 Unitary Products Group • If the suction line is 3/4" diamet er - position the bulb near the top of the copper tube as show n. If the tube is 7/8" diameter - position the bulb near the bottom of the tube. Refer to Figure 7. • Wrap the clamp, bulb & line securely with insulation provided. NOTE: The coil should be ...

  • Coleman F*FP - page 7

    292043-UIM-B-0707 Unitary Products Group 7 ...

  • Coleman F*FP - page 8

    292043-UIM-B-0707 8 Unitary Products Group LO W VOL T A GE CONTR OL CONNECTION The 24 volt power supply is provi ded by an int ernally wired low voltage transformer which is standard on all model s. However, if the unit is con - nected to a 208 volt power supply the low voltage transformer must be rewired to the 208 volt tap. See the unit wiring la ...

  • Coleman F*FP - page 9

    292043-UIM-B-0707 Unitary Products Group 9 TA B L E 3 : Physical and Electrical Data Models F*FP 024 030 036 040 Blower - Diameter x Width 10 x 6 10 x 8 10 x 8 10 x 8 Motor HP 1/4 1/3 1/2 1/3 Nominal RPM 1075 1075 1075 1075 V oltage 208/230 Amps Full Load (208/230) 1.6/1.4 (50 Hz:2.1) 2.5 / 2.2 3.3/2.9 (50 Hz:2.3) 2.5 / 2.2 Locked Rotor (208/230) 3 ...

  • Coleman F*FP - page 10

    292043-UIM-B-0707 10 Unitary Products Group * May be 0 (no breaker) or 1 (with breaker). TA B L E 6 : Electrical Data - 1 Ø - 2 08/230-1 -60 1 Models F*FP Heater* Model Max. St atic & Min. CFM T otal Heat 2 KW St aging 3 KW MBH W1 Only W2 Only W1 + W2 St atic T ap 208V 240V 208V 2 40V 208V 240V 2 08V 240V 208V 240V 024 2HK*6500506B 0.5 Low 3.8 ...

  • Coleman F*FP - page 11

    292043-UIM-B-0707 Unitary Products Group 11 * May be 0 (no breaker) or 1 (with breaker). TA B L E 7 : Electrical D a t a - (For Single Source Power Supply) - Copper W ire 1 Ø - 20 8/230-1-60 1 Models F*FP Heater* Model Heater Amps 240V Field W iring Min. Circuit Ampacity Max. O.C.P . 2 Amps /T ype 75 ° C Wir e Size - A WG 208V 240V 208V 240V 208V ...

  • Coleman F*FP - page 12

    292043-UIM-B-0707 12 Unitary Products Group TA B L E 9 : Electrical Data - 3 Ø - 2 08/230-3 -60 1 Models F*FP Heater 2 Model Max. St atic & Min. CF M T ot al Heat KW St aging 3 KW MBH W1 Only W2 On ly W1 + W2 St atic T ap 208 240 208 240 208 240 208 240 208 240 024 2HK06501025B 0.5 Low 7.5 10.0 25.6 34.1 3.8 5.0 7.5 5.0 7.5 10.0 030 2HK0650102 ...

  • Coleman F*FP - page 13

    292043-UIM-B-0707 Unitary Products Group 13 All F*FP series air handler unit s are UL Listed up to 0.50" w .c. external st atic pressure, including air filter , wet coil, and largest KW size heater . TA B L E 1 1 : Airflow Data for 2 30 V olt - Heat Pump Models 1 1. Includes Return Air Filter and Largest Electric Heate r. Models Blower Motor S ...

  • Coleman F*FP - page 14

    292043-UIM-B-0707 14 Unitary Products Group T A BLE 12: Airflow Data 1 for 208 V olt - Heat Pump Models 1. Includes Return Air Filter and Largest Electric Heate r . All F*FP series air handler unit s are UL Listed up to 0.50" w .c. external st atic pressure, including air filter , wet coil, and largest KW size heater . Models Blower Motor Spee ...

  • Coleman F*FP - page 15

    292043-UIM-B-0707 Unitary Products Group 15 NOTES: 1. “Y” T erm inal on Air Handler Control Bo ard must be connected for full CFM and applications requiring 60 second Blower Off Del ay for SEER enhancement. 2. 1 Optional Dehumidification Humidi stat con tacts open on rise. 3. For F4FV model - Remove Humidistat Jumper on CFM Selection Board - if ...

  • Coleman F*FP - page 16

    Subject to change without notice. Printed in U.S.A. 292043-UIM-B-0707 Copyright © by York International Corp. 2007. All rights reserved. Supersedes: 292043-UIM-A-0507 Unitary 5005 Norman Product Y ork OK Group Drive 73069 DRAIN CONNECTIONS All drain lines should be trapped a minimum of three inches, should be pitched away from unit dr ain pan and ...

Fabricant Coleman Catégorie Air Conditioner

Les documents que nous recevons du fabricant de l'appareilColeman F*FP peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Coleman
- manuels d’utilisations F*FP
- fiches produit Coleman
- dépliants
- ou étiquettes-énergie Coleman F*FP
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Coleman F*FP.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Coleman F*FP, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Coleman F*FP. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Coleman F*FP.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Coleman F*FP, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Coleman F*FP par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Coleman F*FP.

Le manuel d’utilisation complet Coleman, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Coleman F*FP - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Coleman F*FP, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lColeman F*FP qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Coleman F*FP - qui devraient nous aider dans les premières étapes lors de l'utilisation Coleman F*FP
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Coleman F*FP
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Coleman F*FP dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Coleman F*FP?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Coleman F*FP, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Coleman F*FP il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)