SATO GL 4xxeの取扱説明書

35ページ 0.82 mb
ダウンロード

ページに移動 of 35

Summary
  • SATO GL 4xxe - page 1

    R FI D K IT U SE R GUIDE GL 4xx e Series For printer mode ls: Read this User Guide be fore and during the operation o f the above acce ssory. Keep this Guide h an dy for future refere nce. www.satoamerica.com 9001173A ...

  • SATO GL 4xxe - page 2

    2 1 General Important i nforma tion This quick guide provid es im portant inf orm ation on ho w to setup your new SAT O produc t. Be sur e to r ead th is quic k guide thor oughl y bef ore us ing this pri nter. It is an integr al part of the produc t and shou ld be k ept in the im mediate vicinit y of the device a nd av ailable t o the op erat ing s ...

  • SATO GL 4xxe - page 3

    3 1.2 Explanation of s y mbols This instructi on m anual us es various warning icon s to help you understa nd the saf e oper ation of your printer. Expl anations of the icons are belo w. WARNING! Indicates neglec tful or er roneo us use m a y cause irrepara ble dam age to t he produc t, serious injur y to the operat or, or worse. CA UTI ON! Indicat ...

  • SATO GL 4xxe - page 4

    4 1.3 Contact and D ocument Information . Extensive c ontact infor mation of worl dwide SAT O oper atio ns can b e found on the Inter net at www.satoworldwide.com Version: SI-GL4 xxe-01r A-13-06-0 7-RFKUG © Cop yright 199 4 – 200 7 All rights reser ved. No part of th is documen t may b e repro duced or issued to third p arties in an y form whats ...

  • SATO GL 4xxe - page 5

    5 Overview This User Manual describes the opera tion and programming procedures for RFID smart labels (with embedded RFID tags) on the SATO GL4xxe series printers fitted with the RFID Kit. By incorporating RFID commands into the SATO ® Basic Programming Language (SBPL) programs as described herein, users can produce smart labels to take advantage ...

  • SATO GL 4xxe - page 6

    6 1. Introdu ction to the R FID con figuration o ptio ns RFID CONTROL Menu ( GL4xxe Series ) RFID C ONTROL Error Handling O verstrike* None Stop RFID Reade r Ena ble* Disable Label Retr y 10* 1 to 10 Tag W rite Cnt 1 Fail e d Tag Cnt 1 Overstrike Sty le Grid* Error Type Ms g Tag Void Cnt 1 Clea r Ta g S tat Read Tag & Eject Comm Retry 2* 1 to 9 ...

  • SATO GL 4xxe - page 7

    7 ...continued from previous page RFID CO NTRO L Custom Setting Non- RFI D Warn ing Dis abl e* Enable C ust om Tag D u pl i ca t e* Di s ab l e E nab l e Wr i t e P o w e r 6* 1 t o 20 Re a d Po wer 5* 1 t o 20 EPC By t e L e ng t h 12* 8 t o 32 EPC Ad dr es s 0* 0 t o 32 US R By t e Leng t h 0* 0 t o 32 US R Ad d r es s 0* 0 t o 32 T ID B y te L e ...

  • SATO GL 4xxe - page 8

    8 I ntro d uct i on to t h e RFID con fi gurat i on op t i ons R FID Menu Items ( GL4xx e ) RFID Read e r This m enu item enables or disables the RFID enco der. The default is Enab le . Tag Type This m enu item select s the tag t ype for use . See T able 3 for supp orte d tag types listed in alphab etic al order. Ot her type s m ay be adde d in th ...

  • SATO GL 4xxe - page 9

    9 Ta b l e 3. Su pp orted RF ID Ta g T yp es ( GL4x xe ) Ta g Name Bit s Protocol Ta g C lass Menu Se lect io n KSW Gen 2 Excali bur 96 Class 1, Gen 2 Gen 2 KSW Excal G2 KSW Gen 2 T emplar 96 Class 1, Gen 2 Omron Gen 2 Wav e 96 Class 1, Gen 2 Gen 2 KSW T empla r G2 Gen 2 Omron W ave G2 Ra fs ec G e n 2 F r o g ( 3000 790 ) 96 Class 1, Gen 2 Gen 2 R ...

  • SATO GL 4xxe - page 10

    10 I ntro d uct i on to t h e RFID con fi gurat i on opt i ons Tag Write Cnt Displ ays th e num be r of tag s att em pted to be writt en si nce t he last Cle ar T ag Stat ope rat ion was in itiate d. (See “ C lear T ag Stat” .) Faile d Tag C nt Displa ys on the LC D th e n um ber o f f ailed tag write att em pts since t he la st C lear Tag Stat ...

  • SATO GL 4xxe - page 11

    11 Admin Us e r Menu Item s (GL4 xxe) The se menu it em s are vis ible onl y when the A dmin User opt ion is set to Ena bl e in the Advanced menu . (See th e GL408/412 e Operato r’s Manua l.) IM PO RTA NT Admin Us er menu ite ms should only be used by authorized per sonnel. Error Handling This menu it em selects the er ror ha ndlin g mode for RFI ...

  • SATO GL 4xxe - page 12

    12 Rea d Tag Reads t he tag in ra nge of the inter na l RFID c oupl er an d repor ts the tag dat a to the de bug port and momentar ily disp lays it on the con trol pane l’s L CD. It is mainly in tended fo r data veri ficati on pu rposes . IMPORTA NT This menu item does not posi tion the R FID tag over the coupler. Make sure to position the tag ov ...

  • SATO GL 4xxe - page 13

    13 Ta b l e 4. Prin ted O verst r ike Erro r Mes sa g es Error Messa g e Ex p lanation T ag R/W Err x Check me dia Ta g C o m m Err x Chec k cab le The printer software attem pted to write to or rea d from the RFID tag, but the RFID encoder indicated that the tag could not be wr it te n to , or r ead f ro m . The printer soft ware temporaril y lost ...

  • SATO GL 4xxe - page 14

    14 Write P ower This me nu item selec ts the write powe r level to be use d in the R FID encod er. 1 is the lowe st power leve l sett ing, and 20 i s the highest. The defaul t is 6. Read Pow er This m enu it em selec ts t he read pow er le vel to be use d in th e RF ID e ncod er. 1 is the lo west power le vel sett ing, an d 20 i s the hi ghest. The ...

  • SATO GL 4xxe - page 15

    15 Tag Class Selec ts the c lass of the cust om tag. Cla ss 0+, C lass 1. 19, Ge n 2, and Cla ss Zum a tags are r ead/ write . Class 0 tags are re ad on ly. T he def ault is G en 2. Read T ri es Selec ts ho w man y tim es the R FID e ncod er will tr y each read c om ma nd. Th e defa ult is infi nite, whic h cause s the e ncod er to tr y until t he ...

  • SATO GL 4xxe - page 16

    16 Sca n S t a r t Pos Dete rmines wh ere o n the l abel t he RFID cali brati on w ill b egi n. By de fault , th e cal ibrat ion proc edure will start at the begi nn ing of the lab el (0.0 m m ). T o speed th is up cha nge t his valu e to f orce the calib rat ion to begin aft er th e b eg innin g o f th e la bel. Scan Length Determ ines how m uch o ...

  • SATO GL 4xxe - page 17

    17 R e q uestin g A n R FI D R e p ort This proce dure pr ints a su mm arized RFI D rep ort. ( This repo rt als o include s valid ato r data if the pr inte r has a valid ator . ) GL4xxe 1. Take the prin ter off line and pres s ENTER to enter Men u m ode. 2. Pres s the Dow n Arrow and ENT ER but tons at the sa me time until a m ess age “TH E ENT E ...

  • SATO GL 4xxe - page 18

    18 A d vanced RFID Calibration Tag P rofi le r Read and W rite po wer set tings can be op tim ized u sing t he T ag Profiler . Befor e ru nni ng th e Tag Profiler, it is imp ortant t o ensure that the proper Ga p Sensi ng pr ocedure has been follo wed. It is recom m ended th at yo u calibr ate t he prin ter to ensur e that gap sen sing se tt ings a ...

  • SATO GL 4xxe - page 19

    19 • Cu stom (Cal) M ax Po wer. Sets th e upper level th at will be teste d durin g cal ibra tion . To speed up ca libr atio n, set C ust om (Cal) Max Power to t wo points hig her t han t he Cus tom W rite Power th at was s et pr ior to in itiat ing ca librat ion. After set tin g the f our cust om ent ries, ini tia te the ca libr ation c ycle: ac ...

  • SATO GL 4xxe - page 20

    20 2 . RFID Command Speci fication W ith the SAT O GL4X X e , it is possib le to r etur n RF ID inf orm ation b ef ore wr iting dat a. The print er su ppor ts C ont in uous, Tear -of f, Disp enser and Cu tter pr int m ode op tions . U suall y, writing information to the RFID supply takes about 3 seconds to complete. Any abnormali ty that interrup ...

  • SATO GL 4xxe - page 21

    21 ESC+ IP0 Com ma nd ESC IP0 Param eter Hex code <1B> 16 <49>1 6<50 >16<3 0 >16 e, d, k, a, u, m , f,p, s , t, c, n Initia l val ue Nil W hen power s witc h is OFF The set com m and is not mainta ined. V alid r a nge withi n item The set param eter becom es in valid. Valid r ang e and t erm of comm and V alid r an ge be twe ...

  • SATO GL 4xxe - page 22

    22 c = total num ber of digits for compa ny pref ix (Shou ld be an y value wit h 6 to 12 ac cord ing to the num be r of digits of ‘s ’ or ‘t’ param eter s) n = ser ial Num ber (12 digit s) (Shou ld be an y val ue with 12 digits , onl y appli cabl e when EA N13 STGIN 9 6) Coding E xamples 【 Example 1 】 Desc ription: This exam ple ill ust ...

  • SATO GL 4xxe - page 23

    23 【 Example 5 】 Desc ription: This exa m ple il lustr ates t o write EAN 128 da ta to the tag. Data : < A > < V > 50 < H > 50 < X22 > ,3114F5 36CC CE4C30 970 00 000 < IP0 > e: a,d: 3401 7587 46109 9671 ,f: 0,s:10 ,c: 7; < Q1 > < Z > Note: The EAN 12 8 dat a will be enc rypte d as per EPC Ge ner ation 1 Ta g Dat a St ...

  • SATO GL 4xxe - page 24

    24 5 . The op tio na l par amet ers co uld be om itte d. Refer th e ta ble bellow t o fin d o pti onal p ar amet ers. para meters Gen2 e: EPC Type [F*** ] a (EA N12 8 S SCC96) [F***] c (EA N13 SG TI N9 6) [F*** ] z (f ree m apping) d: EP C Data [F***] 17 Digi ts [F***] 13 Digits [F**]1 6 、 24 Digit s k: Kill Code × × [F**] ( 8 digits ...

  • SATO GL 4xxe - page 25

    25 [Fu ncti on ] Th is is a contro l f unctio n f or readi ng dat a fr om the EPC code- com patib le RF ID tag. [Fo rma t] <IP1> ,b:X; W here , b = Blo ck Num ber Bl oc k Na me B l oc k No EPC Are a 1 TID Area 2 User 3 [Return Sta tus Format] [STX(02H)] + Data + [ETX(03H)] Return status list Item Contents (Binary ) No. of bytes STX (02H) Star ...

  • SATO GL 4xxe - page 26

    26 [Return Sta tus Example 1] W hen [8000 00 00 400 0 00 01] is save d in a n EPC-co m patible t ag. 02 Start co de 38 30 30 30 3 0 30 3 0 30 3 4 30 30 3 0 30 30 30 31 03 End code * In actu ality, all data is conti nuous. * Data is d isp layed in he xad ecim al code. [Return Sta tus Example 2] W hen there is no EP C-com pati ble ta g . 02 Start cod ...

  • SATO GL 4xxe - page 27

    27 ESC+TM ESC T M Par am e te r Hexadecim al code <1B>16 <54>16< 4D >16 X Initia l val ue Nil W hen po wer switch is OFF The se t param eter is not ma intain ed. V alid range withi n item The se t param eter becom es inv alid. Valid r ang e and t erm of comm and V alid rang e betwe en item s The se t param eter becom es inv alid. ...

  • SATO GL 4xxe - page 28

    28 ESC +F ESC F Par am ete r Hexadecim al code <1B >16 <4 6>16 a a a a b c c c c, d d, e e, f Initia l val ue Nil W hen power s wit ch is OFF The set param ete r is not m aintain ed. V alid range withi n item The set parame ter beco m es inval id. Valid r ang e and t erm of comm and V alid rang e between item s The set parame ter beco m ...

  • SATO GL 4xxe - page 29

    29 [Coding Exa mple 2] W rit e EP C and Us er m em or y Num ber of time s to repea t the sam e data : 1, inc rem entin g : +, step of seq uenc e:100, Nu mbe r of digit s f or Sequent ia l nu mb ering : 3, N um ber of d igits f re e f rom sequen tial num be ring:2 < A > < V > 100 < H > 100 < P > 2 < L > 0 202 < F > 1+100,3 ,2 ...

  • SATO GL 4xxe - page 30

    30 3. GL RFI D Coupler Desi gn The G L 4 xx e RF ID has a couple r design that suppor ts a gr eate r var i ety of t ag t ype s. Yo u can move the coupler horiz ontally by using the couple r hand le. See figures on foll owing pages . The c ou pl er has fo ur pos i tio ns on a fo ur inch pr inte r. Yellow: 1st Posit ion (furthest inboa rd) Orange: 2n ...

  • SATO GL 4xxe - page 31

    31 4. Adjusting t he Coupler p osition Remove the thumbs crew that secures the lower front cover to the printer. Slide the cover to the left (toward t he electric al half of the pri nter) to remove it . ...

  • SATO GL 4xxe - page 32

    32 Use the co upler h andle t o adjus t the coupl er so th at th e coupler posit ion in dicator points to the correc t color on the c olored pos ition stri p. Alignin g the ta bs, inst all th e lower front c over ( See RFID Kit Install ation Guide ) Step 2 . Secure t he lower front c over to the printer using t he thu m bscrew. Adjusting t he Coupl ...

  • SATO GL 4xxe - page 33

    33 Erro r M e ss ag e Explanation Solutio n NON-RFID DATA On Rfid Tag A job was pr inted that ha d no RFID commands on at least one for m of the job w hile RFID tags w ere installed i n the pri nter and the Non- RFID Warning menu item is set to Enable. Press LINE to clea r th e mes sa ge . Set Non-RFID Warning to Dis able, print a job w ith RFID co ...

  • SATO GL 4xxe - page 34

    34 Sympto m Solutio n No commun ication b etween the printer and the reader 1. Make sure Reader = Enabl e in the RFID (o r RFID CONTROL) menu. 2. Use th e RFID Test option in th e RFID (or RF ID CONTROL) menu (Adm in User en abled ) to read and d ispla y the cu rrent RF ID tag content .. Tag fail ed 1. The label could be m isali gned. Per form t he ...

  • SATO GL 4xxe - page 35

    35 ...

メーカー SATO カテゴリー All in One Printer

SATO GL 4xxeのメーカーから受け取ることができるドキュメントは、いくつかのグループに分けられます。その一部は次の通りです:
- #BRANDの図面#
- GL 4xxeの取扱説明書
- SATOの製品カード
- パンフレット
- またはSATO GL 4xxeの消費電力シール
それらは全部重要ですが、デバイス使用の観点から最も重要な情報は、SATO GL 4xxeの取扱説明書に含まれています。

取扱説明書と呼ばれる文書のグループは、SATO GL 4xxeの取り付け説明書、サービスマニュアル、簡易説明書、またはSATO GL 4xxeのユーザーマニュアル等、より具体的なカテゴリーに分類されます。ご必要に応じてドキュメントを検索しましょう。私たちのウェブサイトでは、SATO GL 4xxeの製品を使用するにあたって最も人気のある説明書を閲覧できます。

関連する取扱説明書

SATO GL 4xxeデバイスの取扱説明書はどのようなものですか?
取扱説明書は、ユーザーマニュアル又は単に「マニュアル」とも呼ばれ、ユーザーがSATO GL 4xxeを使用するのを助ける技術的文書のことです。説明書は通常、全てのSATO GL 4xxeユーザーが容易に理解できる文章にて書かれており、その作成者はその分野の専門家です。

SATOの取扱説明書には、基本的な要素が記載されているはずです。その一部は、カバー/タイトルページ、著作権ページ等、比較的重要度の低いものです。ですが、その他の部分には、ユーザーにとって重要な情報が記載されているはずです。

1. SATO GL 4xxeの説明書の概要と使用方法。説明書にはまず、その閲覧方法に関する手引きが書かれているはずです。そこにははSATO GL 4xxeの目次に関する情報やよくある質問、最も一般的な問題に関する情報を見つけられるはずです。つまり、それらはユーザーが取扱説明書に最も期待する情報なのです。
2. 目次。SATO GL 4xxeに関してこのドキュメントで見つけることができる全てのヒントの目次
3. SATO GL 4xxeデバイスの基本機能を使うにあたってのヒント。 SATO GL 4xxeのユーザーが使い始めるのを助けてくれるはずです。
4. トラブルシューティング。SATO GL 4xxeに関する最も重要な問題を診断し、解決するために役立つ体系化された手続き
5. FAQ。よくある質問
6. 連絡先。一人では問題を解決できない場合に、その国におけるSATO GL 4xxeのメーカー/サービスへの連絡先に関する情報。

SATO GL 4xxeについてご質問がありますか?

次のフォームを使用してください

見つけた説明書を読んでもSATO GL 4xxeの問題を解決できない場合、下記のフォームを使用して質問をしましょう。ユーザーのどなたかがSATO GL 4xxeで同様の問題を抱えていた場合、その解決方法を共有したいと考えるかもしれません。

画像のテキストを入力してください

コメント (0)