  • PowerDsine PD-6548 - page 1

    P P o o w w e e r r o o v v e e r r E E t t h h e e r r n n e e t t M M i i d d s s p p a a n n s s P P D D - - 6 6 5 5 4 4 8 8 4 4 8 8 - - P P o o r r t t M M o o d d e e l l I I E E E E E E 8 8 0 0 2 2 . . 3 3 a a f f - - c c o o m m p p l l i i a a n n t t U U s s e e r r G G u u i i d d e e ...

  • PowerDsine PD-6548 - page 2

    PD-6548 Power over Ethernet Solutions 2 Cat. No.: 06-6860-056 ...

  • PowerDsine PD-6548 - page 3

    PD-6548 Power over Ethernet Solutions 3 Cat. No.: 06-6860-056 Disclaimer PowerDsine assumes no responsibility or liab ility arising from the use of Midspans, as described herein, nor does it convey any lice nse under its patent rights or the rights of others. Applications that are described herein fo r any of theses products are for illustrative pu ...

  • PowerDsine PD-6548 - page 4

    PD-6548 Power over Ethernet Solutions 4 Cat. No.: 06-6860-056 Contents A BBREVIATIONS ....................................................................................... 7 1 S AFETY I NFORMATION ........................................................................ 8 1.1 General Guidelines...................................................... ...

  • PowerDsine PD-6548 - page 5

    PD-6548 Power over Ethernet Solutions 5 Cat. No.: 06-6860-056 List of Figures Figure 2-1: Power over Ethernet Midsp an, Front View (PD-6548) ......... 11 Figure 2-2: Connecting to the Mi dspan................................................... 16 Figure 3-1: Typical Installation ................................................................ 17 Fi ...

  • PowerDsine PD-6548 - page 6

    PD-6548 Power over Ethernet Solutions 6 Cat. No.: 06-6860-056 Model Numbers Definition PD-6548/AC/ M Where : M if present, indicates that the Midspan includ es the Web Management (EMS) feature (refer to Section 4). Verifying Kit Contents Unpack the kit and verify that t he following items are uncluded: • The Power over Ethernet Midspan • Commun ...

  • PowerDsine PD-6548 - page 7

    PD-6548 Power over Ethernet Solutions 7 Cat. No.: 06-6860-056 Abbreviations PD – Powered Device SELV - Safety Extra Low Voltage DTE – Data Terminal Equipment EMS - Element Management System UTP – Unshielded Twisted Pair FTP – Foiled Twisted Pair DHCP – Dynamic Host Configuration Protocol SNMP – Simple Network Management Protocol GUI – ...

  • PowerDsine PD-6548 - page 8

    PD-6548 Power over Ethernet Solutions 8 Cat. No.: 06-6860-056 1 Safety Information 1.1 General Guidelines Read the following safety informati on before carrying out any installation, removal or any maintenance proced ure on the Power over Ethernet Midsp an. Warnings contain in structions that mu st be follo wed for personal and p roduct safety. Fol ...

  • PowerDsine PD-6548 - page 9

    PD-6548 Power over Ethernet Solutions 9 Cat. No.: 06-6860-056 1.2 Power Cord In the event that the power cord is replaced, the replacement must meet local requirements. • For reliable connection to an AC MAINS SUPPLY, equipment pro v ides an appliance IEC60320 inl et for con nection of a detachable power supply cord. • The power socket outlet m ...

  • PowerDsine PD-6548 - page 10

    PD-6548 Power over Ethernet Solutions 10 Cat. No.: 06-6860-056 2 About the Power over Ethernet Midspan PowerDsine’s Mids pans fa mily, injects DC power ov er data-ca rrying Ethernet cabling. The PD-6548 Midspan, support s 48 ports in a 10/100BaseTx Ethernet network, over TIA/EIA-568 Category 5/5e/ 6 cabling. DC operating po wer, for data terminal ...

  • PowerDsine PD-6548 - page 11

    PD-6548 Power over Ethernet Solutions 11 Cat. No.: 06-6860-056 2.2 10/100BASE-TX Ports Definition 2.2.1 Data Input Ports The Midspan has 48 10/100Base-TX d ata input ports, configured in a non- crossover manne r (straight-wi red). These ports lo cated on the PoE’s rea r panel of front box, are de signed to carry Ethernet data only (Tx/Rx) ove r t ...

  • PowerDsine PD-6548 - page 12

    PD-6548 Power over Ethernet Solutions 12 Cat. No.: 06-6860-056 2.3 Indicators A set of indicators provide the status of the Powe r over Ethernet Midsp an and its ports. Refer to Table 2-1 and Ta ble 2-2 for status information du ring operation. 2.3.1 Primary Power Indicators A Primary Power LED (labled “A C”) is located on the front panel; the ...

  • PowerDsine PD-6548 - page 13

    PD-6548 Power over Ethernet Solutions 13 Cat. No.: 06-6860-056 Table 2-1: Po wer Status Indications Indicator Color Symptom Remarks Off Internal power supply unit is unplugged or faulty Internal power supply voltage is too low. Green Indicates AC power input active Internal power supply voltage is within tolerance. AC Orange Internal problem alarm ...

  • PowerDsine PD-6548 - page 14

    PD-6548 Power over Ethernet Solutions 14 Cat. No.: 06-6860-056 2.4 Connectors The Midspan’s front panel inclu de s a Console port (RJ-45 co nne ctor) that supports two communi cation types: 1. Standard DTE Ethernet connector on ly at the web manag able version of the midspan. This connector is a standa rd 10/100BaseTX port that is used for remote ...

  • PowerDsine PD-6548 - page 15

    PD-6548 Power over Ethernet Solutions 15 Cat. No.: 06-6860-056 Table 2-4: Console Cable D-type Connector Pin # Label Description 1 spare 2 RD DTE receive data 3 TD DTE transmit data 4 spare 5 GND DTE GND 6 spare 7 spare 8 spare Each input port is configured as shown in Figure 2-3, as data “Pass-Thro ugh ” ports for all data pins (pins 1, 2, 3 a ...

  • PowerDsine PD-6548 - page 16

    PD-6548 Power over Ethernet Solutions 16 Cat. No.: 06-6860-056 Table 2-6: Front Panel RJ45 Output Plug (per chan nel) Pin # Label Description 1 P_RX+ Plus signal, Receive from DTE to PD 2 P_RX- Minus signal, Receive from DTE to PD 3 P_TX+ Plus signal, Transmit from DTE to PD 4 Vdc (+) Feeding power (+) 5 Vdc (+) Feeding power (+) 6 P_TX- Minus sign ...

  • PowerDsine PD-6548 - page 17

    PD-6548 Power over Ethernet Solutions 17 Cat. No.: 06-6860-056 3 Installing the Power over Ethernet Midspan 3.1 Background The Midspan is connected (se e Figure 3-1) in series to an Ethernet switch/hub. The d ata outputs from the swit ch are conne cted to Midspan’s input ports. The Midspan delivers p ow er over spare twisted pairs (pins 7/8 and p ...

  • PowerDsine PD-6548 - page 18

    PD-6548 Power over Ethernet Solutions 18 Cat. No.: 06-6860-056 3.2 Rack Mounting Brackets The Midspan is supplied with mounting brackets, plate s and screws utilized for assembling the Mids pan in an 19-in rack. 1. Install two clip nuts on each bracket. 2. Tighten two brackets to both sides of the ra ck‘s rails using the supplied plates and 10-32 ...

  • PowerDsine PD-6548 - page 19

    PD-6548 Power over Ethernet Solutions 19 Cat. No.: 06-6860-056 3.3 Routing the Input Ports Cables The ports on the front p anel of th e Midspan are configured as "Pass Through" ports for all 48 co nductors of the RJ-45 connectors. Use Category 5 jumpers cables with a diam eter that is less than 0.25 inch in making connections. * Using an ...

  • PowerDsine PD-6548 - page 20

    PD-6548 Power over Ethernet Solutions 20 Cat. No.: 06-6860-056 Figure 3-2: Cable Connections 4. Upon completion of 48 cables conn ections, the Midspan should be installed into the rack. ...

  • PowerDsine PD-6548 - page 21

    PD-6548 Power over Ethernet Solutions 21 Cat. No.: 06-6860-056 3.4 Assembling Midspan to Rack Assemble the Midspan (inc luding its c ables) to the previously install ed brackets as shown below, using two 10-32” scre ws pl us lock wash er and flat washer (one on each si de of the rack). Note: Verify that the Midspan’s ventilation holes on both s ...

  • PowerDsine PD-6548 - page 22

    PD-6548 Power over Ethernet Solutions 22 Cat. No.: 06-6860-056 3.5 Connecting Data Cables 1. Connect the previously routed ca ble s to the swit ch’s output ports. 2. Connect the cables from the IEEE 802.3af ready terminals (P Ds) to the corresponding Data & Power p orts on the Midspan’s front panel. 3.6 Connecting Power Cables When using AC ...

  • PowerDsine PD-6548 - page 23

    PD-6548 Power over Ethernet Solutions 23 Cat. No.: 06-6860-056 3.8 Troubleshooting 3.8.1 Preliminary Steps If you encounter problems, verify that: 1. Power is applied to the Midspan 2. A crossover-type Ethernet cable has not been used 3. The Ethernet cable from the network i s connected to the Data input port 4. The Ethernet cable to the PD is conn ...

  • PowerDsine PD-6548 - page 24

    PD-6548 Power over Ethernet Solutions 24 Cat. No.: 06-6860-056 Table 3-1: Troubleshooting Steps Symptom Correcti ve Steps AC indicator lit orange Power-on self-test fail ed: the Midspan de tected an internal fault. In this case, contact your local dealer. Midspan repeate dly shutsdown for few minutes and then starts Verify that the ve ntilation hol ...

  • PowerDsine PD-6548 - page 25

    PD-6548 Power over Ethernet Solutions 25 Cat. No.: 06-6860-056 3.9 Technical Specifications 3.9.1 Physical Specifications Height : 1U 44mm, 1.75” Width : standard 19” Rack mount 438mm, 17.2” Depth : 460mm, 18.1” Weight : 7.5 Kg, 15 lb. Temperature - Operating 0 to 40 °C (32 to 122 °F) - Storage -20 to 70 °C (-4 to 158 °F) Humidity 10 to ...

  • PowerDsine PD-6548 - page 26

    PD-6548 Power over Ethernet Solutions 26 Cat. No.: 06-6860-056 4 Remote Web Management Remote Web Management is an optional feature, for monitoring and control of the device. For further details, refer to PowerDsine’s PowerView, Power over E thernet Web Manag er User Guide. PowerView manages Midspans via an We b Manager or via a remote Network Ma ...

  • PowerDsine PD-6548 - page 27

    PD-6548 Power over Ethernet Solutions 27 Cat. No.: 06-6860-056 ...

  • PowerDsine PD-6548 - page 28

    Part Number: 06-6860-056 Rev 1.1 Covered under U.S patent S/N 6, 473,60 8 and equivalent worldwi de Visit our web site at: www.powerdsine.com For technical support, call: +97 2-9-7755123 In the USA: +631-756-4680 or 1-877-4-802-3AF ...

Manufacturer PowerDsine Category Network Card

Documents that we receive from a manufacturer of a PowerDsine PD-6548 can be divided into several groups. They are, among others:
- PowerDsine technical drawings
- PD-6548 manuals
- PowerDsine product data sheets
- information booklets
- or energy labels PowerDsine PD-6548
All of them are important, but the most important information from the point of view of use of the device are in the user manual PowerDsine PD-6548.

A group of documents referred to as user manuals is also divided into more specific types, such as: Installation manuals PowerDsine PD-6548, service manual, brief instructions and user manuals PowerDsine PD-6548. Depending on your needs, you should look for the document you need. In our website you can view the most popular manual of the product PowerDsine PD-6548.

Similar manuals

A complete manual for the device PowerDsine PD-6548, how should it look like?
A manual, also referred to as a user manual, or simply "instructions" is a technical document designed to assist in the use PowerDsine PD-6548 by users. Manuals are usually written by a technical writer, but in a language understandable to all users of PowerDsine PD-6548.

A complete PowerDsine manual, should contain several basic components. Some of them are less important, such as: cover / title page or copyright page. However, the remaining part should provide us with information that is important from the point of view of the user.

1. Preface and tips on how to use the manual PowerDsine PD-6548 - At the beginning of each manual we should find clues about how to use the guidelines. It should include information about the location of the Contents of the PowerDsine PD-6548, FAQ or common problems, i.e. places that are most often searched by users in each manual
2. Contents - index of all tips concerning the PowerDsine PD-6548, that we can find in the current document
3. Tips how to use the basic functions of the device PowerDsine PD-6548 - which should help us in our first steps of using PowerDsine PD-6548
4. Troubleshooting - systematic sequence of activities that will help us diagnose and subsequently solve the most important problems with PowerDsine PD-6548
5. FAQ - Frequently Asked Questions
6. Contact detailsInformation about where to look for contact to the manufacturer/service of PowerDsine PD-6548 in a specific country, if it was not possible to solve the problem on our own.

Do you have a question concerning PowerDsine PD-6548?

Use the form below

If you did not solve your problem by using a manual PowerDsine PD-6548, ask a question using the form below. If a user had a similar problem with PowerDsine PD-6548 it is likely that he will want to share the way to solve it.

Copy the text from the picture

Comments (0)