Bedienungsanleitung Goodman Mfg IO - 395

16 Seiten 0.59 mb
Download

Zur Seite of 16

Summary
  • Goodman Mfg IO - 395 - page 1

    C US ® *NOTE: Please contact your distributor or our website for the applicable S pecification Sheets referred to in this manual. RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION. A TTENTION INST ALLING PERSONNEL Prior to installation, thoroughly familiarize yourself with this Inst allation Manual. Observe all safety warnings. During installation or r ...

  • Goodman Mfg IO - 395 - page 2

    2 W ARNIN G I NSTALLATION AN D REP AIR OF THIS UNI T SHO ULD BE PERFO RMED ON L Y BY IN DIVI DUALS MEE T I NG THE REQUIREMENTS OF AN “E NTRY L EVEL T ECHNICIAN ” AS SPECIFIED BY THE A IR -C OND ITI ONI NG , H EATI NG , AN D R EFR IGE RAT IO N I NST ITUT E (AHR I). A TTE MPTING TO INST ALL OR REPAIR THIS UNI T WI TH OUT SUCH BACKGROUND MA Y RES ...

  • Goodman Mfg IO - 395 - page 3

    3 “Product Registration” located on the left side of the Warranty page and complete the forms in the manner indicated on the Product Registration page. Product limited warranty certificates for models currently in production can be viewed at www .goodmanmfg.com. If your model is not currently in production or does not appear on the website, ple ...

  • Goodman Mfg IO - 395 - page 4

    4 The information on the rating plate is in compliance with the FTC & DOE rating for single phase units. The three phase units in this series are not covered under the DOE certified program. The efficiency ratings of these units are a product of thermal effi- ciency determined under continuous operating conditions inde- pendent of any installed ...

  • Goodman Mfg IO - 395 - page 5

    5 Rooftop Installation R OOF C URB I NSTALLATIONS O NLY NOTE: Sufficient structural support must be determined prior to locating and mounting the curb and package unit. Curb insulation, cant strips, flashing and general roofing material are furnished by the contractor . Curbing must be installed in compliance with the National Roofing Contractors A ...

  • Goodman Mfg IO - 395 - page 6

    6 Remov e these c overs for hor iz o ntal duct applic ations Remove these panels for do wnflow duct applicat ions Supply Return Duct Cover Installation Down Discharge Applications Cut insulation around bottom openings and remove panels from the bottom of the unit, saving the screws holding the panels in place. NOTE: Single phase models require inst ...

  • Goodman Mfg IO - 395 - page 7

    7 WIRING NOTE: All wiring should be made in accordance with the National Electrical Code. Consult your local Power Company to determine the availability of sufficient power to operate the unit. Check the volt age, frequency , and phase at the power supply to ensure it corresponds to the unit’s RA TED VOL T AGE REQUIREMENT . In accordance with the ...

  • Goodman Mfg IO - 395 - page 8

    8 BRANCH CIRC UIT A MPA CITY 15 20 25 30 35 40 45 50 SUPPLY WI RE LENGTH - FEET 2 0 0 64443322 1 5 0 86644433 1 0 0 1 0 8866644 5 0 1 4 1 2 1 0 1 0 8866 2. Wire size based on 60° C rated wire insulation and 30° C Ambient T emperature (86° F). 3. For more than 3 conductors in a raceway or cable, see the N.E.C. for derating the ampacity of each co ...

  • Goodman Mfg IO - 395 - page 9

    9 Crankcase Heater This item is “ON” whenever power is supplied to the unit and the crankcase heater thermostat is closed. Crankcase heater thermostat closes at 67° and opens at 85°. It warms the compressor crankcase thereby preventing liquid migration and subsequent compressor damage. The insert type heater is self regulating. It is connecte ...

  • Goodman Mfg IO - 395 - page 10

    10 supplementary heat for all heat pump installations in areas where the temperature drops below 45° F . It is also a good practice to provide sufficient supplementary heat to handle the entire heating requirement should there be a component failure of the heat pump, such as a compressor , or refrigerant leak, etc. Since the temperature of the ref ...

  • Goodman Mfg IO - 395 - page 11

    11 0.1 0. 2 0.3 0.4 0. 5 0.6 0.7 0. 8 CFM 1122 1078 1032 972 915 804 687 558 W A TTS 338 330 321 310 300 283 264 250 CFM 1387 1331 1264 1209 1119 1041 935 748 W A TTS 456 440 428 412 399 382 363 330 CFM 1521 1454 1388 1311 1230 1144 1055 939 W A TTS 534 521 510 490 477 461 442 420 CFM 1,140 1,395 1, 360 1,310 1,265 1, 235 1,190 1, 130 W A TTS 275 2 ...

  • Goodman Mfg IO - 395 - page 12

    12 S PEED T AP A DJUSTMENTS F OR I NDOOR B LOWER M OTOR PSC Motor Adjust the CFM by changing the speed tap of the indoor blower motor at the EBTDR “COM” connection with one of the speed taps on “M1” or “M2”. (Black-High S peed, Blue-Medium S peed, Red- Low S peed.) X-13 Motor Adjust the CFM by changing the 24V low voltage lead at the sp ...

  • Goodman Mfg IO - 395 - page 13

    13 Un it Mod el Nu mb er 5 8 10 15 2 0 G PH13 24M 41 ** M (F ) M (F ) M (F ) HN A G PH13 30M 41 ** M (F ) M (F ) M (F ) HN A G P H /G PC1 336M41* * MM H (F ) H (F ) NA G PH13 42M 41 ** MM H (F ) H (F ) NA G P H /G PC1 348M41* * 3 (F ) 3 (F ) 3 (F ) 3 (F ) 3 (F ) G P H /G PC1 360M41* * 3 (F ) 3 (F ) 3 (F ) 3 (F ) 3 (F ) G PC13 36M 43 ** -- - -- - -- ...

  • Goodman Mfg IO - 395 - page 14

    14 TROUBLESHOOTING CHART SYMPTOM High head - low suct ion a. Restr i c ti on i n li qui d li ne or f lowr ato r a. Remov e or r epl ace wi th pr ope r s iz e f l o wr a t or . High head - hi gh or nor ma l s ucti on a. Dirt y c ondense r c oil a. Cle an c oi l. b. O v er c har g ed b. Co r rec t S y s tem c har g e. c . C ondens e r fan no t runni ...

  • Goodman Mfg IO - 395 - page 15

    15 APPENDIX UNIT DIMENSIONS BLOWE R ACCESS P ANEL ? ? 2 34 51 47 SUP PL Y 1 3/8 A RETURN POW ER WI RE ENT RANCE 4 1/8 2 1/8 6 ½ 16 16 5 ½ B B CONTROL WI RE ENT RANCE CONDENSA TE DRA I N CONNECTION 3/ 4” NP T FE M ALE 18 7/ 8 SUCTIO N/LIQUID PRE SSU RE PO RT 3 8 MEDIUM CHASSIS GP*1324M4** GP*1330M4** GP*1336M4** GP*1342M4** LARGE CHASSIS GP*1348 ...

  • Goodman Mfg IO - 395 - page 16

    16 MINIMUM CLEARANCES RECOMMENDED FIL TER SIZES 3" MI N 12 " M IN 36 " M I N (FOR SER VICE) . 48 " M IN 12 " M IN 36 " M IN (F O R SE RVIC E) NOTE: Roof overhand should be no more than 36” U N I T 2 ton 2 -1 /2 ton 3 to n 3 -1 /2 to n 4 to n 5 ton M i n. F il t er S ize ( 1 ) 2 5x25 x 1 (1) 25x2 5x1 (1) 25 x25x 1 (1 ...

Produzent Goodman Mfg Kategorie Air Conditioner

Dokumente, die wir vom Produzenten des Geräts Goodman Mfg IO - 395 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Goodman Mfg
- Bedienungsanleitungen IO - 395
- Produktkarten Goodman Mfg
- Informationsbroschüren
- oder Energieetiketten Goodman Mfg IO - 395
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Goodman Mfg IO - 395.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Goodman Mfg IO - 395, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Goodman Mfg IO - 395. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Goodman Mfg IO - 395 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Goodman Mfg IO - 395, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Goodman Mfg IO - 395 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Goodman Mfg IO - 395 verständlich ist.

Eine gänzliche Bedienungsanleitung von Goodman Mfg sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Goodman Mfg IO - 395 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Goodman Mfg IO - 395 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Goodman Mfg IO - 395, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Goodman Mfg IO - 395 - die uns die ersten Schritte während der Nutzung von Goodman Mfg IO - 395 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Goodman Mfg IO - 395 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Goodman Mfg IO - 395 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Goodman Mfg IO - 395?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Goodman Mfg IO - 395 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Goodman Mfg IO - 395 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)