Bedienungsanleitung Zephyr ALL-E42AW X

25 Seiten 2.3 mb
Download

Zur Seite of 25

Summary
  • Zephyr ALL-E42AW X - page 1

    ww w .zeph yronline .com Duo Is. ADL-M90ASX ADL-E42ASX Lay ers Is. ALL-M90ABX ALL-M90A WX ALL-E42A WX ALL-E42ABX RANGE HOOD - Installation instructions ...

  • Zephyr ALL-E42AW X - page 2

    ww w .zeph yronline .com HO T TE PER CUISINE - Notice d’utilisation ...P ag. 25 CAMP ANA EXTRACT OR A - Manual de utilización ...P ag. 48 CAPP A ASPIRANTE - istruzioni per l’uso ...P ag. 73 - 2 - ...

  • Zephyr ALL-E42AW X - page 3

    C onten ts SAFETY INSTRUC TIONS .................................................................................................. pag . 4 LIST OF MA TERIALS ........................................................................................................... pag . 7 DUCTING C AL CULA TION SHEETS .............................................. ...

  • Zephyr ALL-E42AW X - page 4

    ww w .zeph yronline .com IMPORT ANT SAFETY INSTRUC TIONS FOR RESIDENTIAL USE ONL Y READ AND SA VE THESE INSTRUC TIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORT ANT : Save these Instructions for the Local Electrical Inspectors use. INST ALLER : Please leave these Instructions with this unit for the owner . OWNER : Please retain these ...

  • Zephyr ALL-E42AW X - page 5

    settings. B. Always turn hood ON when c ook ing at high heat or when  ambeing foods ( i.e. Cr epes Suzette , Cherries Jubilee, P eppercorn Beef F lambè ). C. Clean ventilating fans fr equently . Grease should not be allow ed to accumulate on fan or  lter . D. Use proper pan siz e. Alwa ys use cookware appropriat e for the siz e of the sur fa ...

  • Zephyr ALL-E42AW X - page 6

    ww w .zeph yronline .com through the  ue (chimney) of fuel burning equipment to pr event back drafting. F ollow the heating equipment manufacturer ’ s guideline and safety standards such as those published by the National F ire Pr otec tion Association (NFP A), and the American Society for Heating, Refrigeration and Air C onditioning Engineers ...

  • Zephyr ALL-E42AW X - page 7

    List of Materials Decorative Mesh F ilters Cont rol Blower Housing Light Bulbs Range Hood Body Duct Covers Suppor t F rame Assembly Light P anel TYPE DESCRIPTION N° A M4 1 + 1 B 1/8" x 1/4" 28 C 1/4" x 2-3/4" 4 Models: ADL-M90ASX / ADL -E42ASX - 7 - ...

  • Zephyr ALL-E42AW X - page 8

    ww w .zeph yronline .com List of Materials TYPE DESCRIPTION N° A M4 1 + 1 B 1/8" x 1/4" 28 C 1/4" x 2-3/4" 4 Duct Covers Suppor t F rame Assembly Blower Housing Range Hood Body Glass Decorative Mesh F ilters Light Bulbs Cont rol Models: ALL-M90ABX / ALL -M90A WX / ALL -E42A WX / ALL -E42ABX - 8 - ...

  • Zephyr ALL-E42AW X - page 9

    Duc ting Calcula tion Sheet Maximum Duct Length: F or satisfac tory air mov ement, the total duct length should not exceed 100 equivalent f eet. - 9 - ...

  • Zephyr ALL-E42AW X - page 10

    ww w .zeph yronline .com 35-3/8" or 42" W ood T rim Dimensions 1-5/8" Thick ness 23-5/8" 13" 11-1/4" Hood Speci cations front of hood side of hood top of hood Models: ADL-M90ASX / ADL -E42ASX - 10 - ...

  • Zephyr ALL-E42AW X - page 11

    Hood Speci cations front of hood side of hood top of hood Models: ALL-M90ABX / ALL -M90A WX / ALL -E42A WX / ALL -E42ABX - 11 - ...

  • Zephyr ALL-E42AW X - page 12

    ww w .zeph yronline .com Installation - In ternal Blow er The follo wing instruc tions are for installing the internal blo wer . CA UTION: T o reduce the risk of  re and electric shock, install this range- hood only with internal blow er models MT -020 provided with the kit cod CBI-600A. F or external and in-line blower prepar ation please turn ...

  • Zephyr ALL-E42AW X - page 13

    Installation - In ternal Blow er 6. Attach the 6 pin male molex connector from blower wir e to the 6 pin female molex con- nector located inside the blower housing . See Fi g. 6 7. Install the motor and bracket, inside the motor housing, c ompleting the installation using the other screws (6 type B )that hav e been sup - plied. ( T ot. 13 t ype B). ...

  • Zephyr ALL-E42AW X - page 14

    ww w .zeph yronline .com Installation - External & In-Line Blow er Pr epar ation The follo wing instruc tions are for pr eparing the hood for use with an e x- ternal or in-line blow ers models CBE-1000 or PBN-1000A. CA UTION: T o reduce the risk of  re and electric shock, install this rangehood only with remote blow ers rated maximum 6.2 A. ...

  • Zephyr ALL-E42AW X - page 15

    Installation - External & In-Line Blow er Pr epar ation Note1 : A cable lock (not included) may be re- quired by local c odes. Please r eview local co- des for mor e information. 6. Reinstall the cov er on the motor housing by follo wing the instructions from step 2 in re- verse or der . 7. Attach 6 pin male molex connectors to 6 pin female mol ...

  • Zephyr ALL-E42AW X - page 16

    ww w .zeph yronline .com W ARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls , crawl spaces, c eiling, attics or garages . All exhaust must be ducted to the outside, unless using the r ecirculating op- tion. Use single wall rigid Metal ductwork only . F asten all connections with sheet metal screws and tape all j ...

  • Zephyr ALL-E42AW X - page 17

    MOUNTING HEIGHTS The range hood must be installed at a minimum height of 24 inches (61 cm) from the cooking sur face. If a connecting duc t work c omposed of two par ts is used, the upper part must be placed outside the low er par t. Do not connect the range hood duc t to the same duct used to exhaust hot air or fumes from another appliance . Befor ...

  • Zephyr ALL-E42AW X - page 18

    ww w .zeph yronline .com into the attic to connect after the hood is installed. F ig.11 3. Place assembled support frames on top of hood and secure it t o the hood body using 8 type B screws. F ig.12 4. Place duct covers o ver assembled suppor t frame until they rest on the hood body . F ig.13 Note! If you ordered a w ood trim piece or re - circula ...

  • Zephyr ALL-E42AW X - page 19

    5. P osition hole template on the ceiling paying at- tention that the arro w is positioned on the same side as the range hood controls . - Make 4, holes in the ceiling and drive in (3 type C) screws without c ompletely tightening them. P ay attention not to insert the screw into the hole marked with an X on the hole template F ig.14 6. Lift the hoo ...

  • Zephyr ALL-E42AW X - page 20

    ww w .zeph yronline .com Installation - P o wer Supply C onnec tion GENERAL • Carefully r ead the following impor tant information r egarding installation safety and maintenance . Keep this information book let accessible f or fur ther consultations. POWER SUPPL Y C ONNEC TION F or connec tion to the po wer supply ref er to the f ollowing: 1. T e ...

  • Zephyr ALL-E42AW X - page 21

    Installation - P o wer Supply C onnec tion - Connect the electrical conduit to the F ield Wiring C ompar tment using listed onduit  ttings. - Carry out the power supplly connection in accor dance with the national electric code, ANSI/NFP A 70-1999. 5. Replace the lid by f ollowing the instruc tions from st ep 3 in reverse or der , ensu- ring tha ...

  • Zephyr ALL-E42AW X - page 22

    ww w .zeph yronline .com Maintencanc e MAINTENANCE • It is recommended to operate the appliance prior t o cooking. It is recommended to leav e the appliance in operation f or 5 minutes after cooking is completed in order to c ompletely eliminate cooking vapors and odors. The pr oper func tion of the range hood is conditioned by the r egularity of ...

  • Zephyr ALL-E42AW X - page 23

    List of P ar ts and A c cessories DESCRIPTION HOOD P ART# REPLA CEMENT P ART S Light Bulb G4, 20W (each) ADL Z0B0013 Light Bulb GU4, 20W (each) ALL Z0B0030 OPTIONAL A CCESSORIES Recirculating Kit ADL, ALL ZRC-00LL Replacement Char coal F ilt ers ADL, ALL Z0F-00AC Duct Cover Extension, Short (9” ceiling) ADL, ALL Z1C-00LL Duct Cover Extension, L o ...

  • Zephyr ALL-E42AW X - page 24

    ww w .zeph yronline .com - 24 - ...

  • Zephyr ALL-E42AW X - page 25

    3LIK0500 ...

Produzent Zephyr Kategorie Ventilation Hood

Dokumente, die wir vom Produzenten des Geräts Zephyr ALL-E42AW X erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Zephyr
- Bedienungsanleitungen ALL-E42AW X
- Produktkarten Zephyr
- Informationsbroschüren
- oder Energieetiketten Zephyr ALL-E42AW X
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Zephyr ALL-E42AW X.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Zephyr ALL-E42AW X, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Zephyr ALL-E42AW X. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Zephyr ALL-E42AW X ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Zephyr ALL-E42AW X, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Zephyr ALL-E42AW X hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Zephyr ALL-E42AW X verständlich ist.

Eine gänzliche Bedienungsanleitung von Zephyr sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Zephyr ALL-E42AW X bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Zephyr ALL-E42AW X befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Zephyr ALL-E42AW X, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Zephyr ALL-E42AW X - die uns die ersten Schritte während der Nutzung von Zephyr ALL-E42AW X erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Zephyr ALL-E42AW X hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Zephyr ALL-E42AW X im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Zephyr ALL-E42AW X?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Zephyr ALL-E42AW X nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Zephyr ALL-E42AW X hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)