    1 W415-0385 / A / 10.02.03 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon R d., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .continentalfireplaces.com • ask@continentalfire.com R-2000 CERTIFIED UNDER CANADIAN AND AMERICAN NA TIONAL ST ANDARDS, CSA 2.33, ANSI ...

  • Continental Fireplaces BCDV42N - page 2

    2 W415-0385 / A / 10.02.03 WARNING • • • • • Do not burn wood or other ma terials in this fireplace . • Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Supervise young children when they are in the same room as the fir eplace . • Due ...

  • Continental Fireplaces BCDV42N - page 3

    3 W415-0385 / A / 10.02.03 CONDITIONS AND LIMIT A TIONS WOLF STEEL LTD. warrants its products against manufacturing defects to the original purchaser only -- i.e., the individual or l egal entity (registered customer) whose name appears on the warranty registration card filed with WOLF STEEL Ltd. -- provided that the purchase was made through an au ...

  • Continental Fireplaces BCDV42N - page 4

    4 W415-0385 / A / 10.02.03 THIS GAS FIREPLACE SHOULD BE INST ALLED AND SERV - ICED BY A QUALIFIED INST ALLER to conform with local codes. In absence of local codes, install the B CDV42 to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes. Installation practices vary from region to region and it is impo ...

  • Continental Fireplaces BCDV42N - page 5

    5 W415-0385 / A / 10.02.03 Use only Wolf S teel or Simpson Dura-V ent Model DV -GS venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and air termi- nal locations for either system are set out in this manual and must be adhered to. For Simpson Dura-V ent, follow the installation procedure provided ...

  • Continental Fireplaces BCDV42N - page 6

    6 W415-0385 / A / 10.02.03 * Recommended to prevent condensation on windows and thermal breakage ** Using a Napoleon soffit heat shield, W585-0096, or equivalent, the distance may be reduced to a minimum of 18". It is recommended to maximize the distance to vinyl clad soffits. *** The periscope GD-401 requires a minimum 18 inches clearance fro ...

  • Continental Fireplaces BCDV42N - page 7

    7 W415-0385 / A / 10.02.03 Use the GD401 periscope kit to locate the air termination above grade. The periscope must be installed so that when final grading is completed, the bottom air slot is located a minimum of 12 inches above grade. The maximum allow- able vent length depends on the fireplace, as illustrated. FIGURES 3 a-c FIGURE 4 TYPICAL VEN ...

  • Continental Fireplaces BCDV42N - page 8

    8 W415-0385 / A / 10.02.03 VER VER VER VER VER TICAL TICAL TICAL TICAL TICAL TERMIN TERMIN TERMIN TERMIN TERMIN A A A A A TION TION TION TION TION HORIZONT HORIZONT HORIZONT HORIZONT HORIZONT AL AL AL AL AL TERMIN TERMIN TERMIN TERMIN TERMIN A A A A A TION TION TION TION TION vertical rise vertical rise vertical rise vertical rise vertical rise is ...

  • Continental Fireplaces BCDV42N - page 9

    9 W415-0385 / A / 10.02.03 ELBO W VENT LENGTH V AL UES DEFINITIONS HORIZONT AL TERMINA TION REQUIRED VERTICAL RISE IN FEET (V T ) CALCULA TED HORIZONT AL VENT RUN PLUS OFFSETS IN FEET (H T ) FIGURE 5 45º FIGURE 6 90° H 1 H 2 when (H T ) < (V T ) Simple venting configuration (only one 45º and 90° elbow) for the following symbols used in the v ...

  • Continental Fireplaces BCDV42N - page 10

    10 W415-0385 / A / 10.02.03 V 1 HORIZONT AL TERMIN A TION See graph to determine the re- quired vertical rise V T for the re- quired horizontal run H T . For vent configurations requiring more than one 45º and 90° elbow the following formulas apply: Formula 1: H T < 4.2 V T Formula 2: H T + V T < 24.75 feet FIGURE 7 REQUIRED VERTICAL RISE I ...

  • Continental Fireplaces BCDV42N - page 11

    11 W415-0385 / A / 10.02.03 VERTICAL TERMIN A TION Example 3: V 1 =5 f t V 2 = 10 ft V T = V 1 + V 2 = 5 + 10 = 15 ft H 1 =3 f t H 2 = 2.5 ft H R = H 1 + H 2 = 3 + 2.5 = 5.5 ft H O = .03(one 45º elbow + three 90º elbows - 135º) = .03(45+90+90+90-135)=5.4 H T = H R + H O = 5.5 + 5.4 = 10.9 ft H T + V T = 10.9 + 15 = 25.9 ft Formula 1: H T < V ...

  • Continental Fireplaces BCDV42N - page 12

    12 W415-0385 / A / 10.02.03 H 1 VERTICAL TERMIN A TION For vent configurations requiring more than one 45º and one 90° elbow , the following formulas apply: F or mula 1: H T < 3V T F or mula 2: H T + V T < 40 fee t Example 4: when (H T ) > (V T ) Simple venting configurations See graph to determine the required vertical rise V T for the ...

  • Continental Fireplaces BCDV42N - page 13

    13 W415-0385 / A / 10.02.03 This application occurs when venting through a roof. Installation kits for various roof pitches are available from your Con- tinental dealer . See Ac- cessories to order the specific kit required. 1. Determine the air terminal location, cut and frame 10 inch openings in the ceiling and the roof to provide the minimum 1 i ...

  • Continental Fireplaces BCDV42N - page 14

    14 W415-0385 / A / 10.02.03 Use only approved aluminum flexible liner kits marked: "Wolf Steel Appr o ved V enting" as identifi ed by the stamp only on the 8” outer liner . FIGURE 18 F or safe and proper operation of the fireplace, follow the venting instr uctions e xactly . A VENT HEA T SHIELD MUST BE USED IF THE W ALL TERMI- NAL IS IN ...

  • Continental Fireplaces BCDV42N - page 15

    15 W415-0385 / A / 10.02.03 FIGURE 25 The vent system must be supported approximately every 3 feet for both vertical and horizontal runs. Use Wolf S teel vent spacers every 3 feet and either side of each elbow to maintain the minimum 1¼" clearance between the outer and inner vent pipes. Use Wolf S teel support ring assem- bly or equivalent no ...

  • Continental Fireplaces BCDV42N - page 16

    16 W415-0385 / A / 10.02.03 V ertical terminations may display a very active flame. If this appearance is not desirable, the vent exit must be restricted using restrictor plate, W080-0454. This reduces the veloc- ity of the exhaust gases, slowing down the flame pattern and creating a more traditional appearance. Proceed once the vent installation i ...

  • Continental Fireplaces BCDV42N - page 17

    17 W415-0385 / A / 10.02.03 It is best to frame your fireplace after it is positioned and the vent system is installed. Use 2x4's and frame to local building codes. FIGURES 31-33. It is not necessary to install a hearth extension with this fireplace system. When roughing in the fireplace, raise the fireplace to ac- commodate for the thickness ...

  • Continental Fireplaces BCDV42N - page 18

    18 W415-0385 / A / 10.02.03 NAILING TA B 1) Attach the nailing tabs to the corner posts using the 2 sheet metal screws supplied. Secure through the centre of the top and bottom slots in the nailing tab and then through the existing holes in the corner posts. If there are no existing holes, follow these instructions: Position the nailing tab so that ...

  • Continental Fireplaces BCDV42N - page 19

    19 W415-0385 / A / 10.02.03 1. Remove the upper louvres, and open the glass door . Remove the logs. 2. Remove the securing screw al- ready in place at the back of the fire- box. If the unit is supplied with a rear log support, remove before install- ing the rear brick panel. Place the rear panel against the back of the firebox and re-install the re ...

  • Continental Fireplaces BCDV42N - page 20

    20 W415-0385 / A / 10.02.03 4. Cradle the notch on the bottom of the left crossover log (#4) around the left outermost grate post and the top into the pocket provided on the back log. Position the notch located on the end of the center log (#5) against the middle grate post with the other end of the log resting in the pocket of the left crossover l ...

  • Continental Fireplaces BCDV42N - page 21

    21 W415-0385 / A / 10.02.03 INST ALLA TION T O BE DONE BY A QUALIFIED INST ALLER and must be electrically connected and grounded in ac- cordance with local codes. In the absense of local codes, use the current CSA C22.1 C ANADIAN ELECTRICAL CODE in Canada or the ANSI/NFP A 70 NA TIONAL ELECTRICAL CODE in the United S tates If the fireplace was not ...

  • Continental Fireplaces BCDV42N - page 22

    22 W415-0385 / A / 10.02.03 ELECTRICAL INST ALLA TION TO BE DONE BY A QUALI- FIED INST ALLER and must be connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 C ANADIAN ELECTRICAL CODE in Canada or the ANSI/NFP A 70 NA TIONAL ELECTRICAL CODE in the United S tates. T o safely install the fan, ...

  • Continental Fireplaces BCDV42N - page 23

    23 W415-0385 / A / 10.02.03 GAS KNOB P I L O T H I O L P O F F L O P I N O L O T F F O When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condi- tion caused by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will n ...

  • Continental Fireplaces BCDV42N - page 24

    24 W415-0385 / A / 10.02.03 Adjust the pilot screw to provide properly sized flame. Turn in a clockwise direction to reduce the gas flow . Air shutters have been factory set open according to the chart below: These settings are for the maximum horizontal vent run.- Adjustment may be required depending on fuel type, vent configuration and altitude. ...

  • Continental Fireplaces BCDV42N - page 25

    25 W415-0385 / A / 10.02.03 # P ART N O. DESCRIPTION 1 W357-0001 PIEZO IGNITER 2 W680-0004 THERMOPILE 3 *W680-0005 THERMOCOUPLE 4 W010-0800 NA TURAL GAS PILOT ASSEMBL Y 4 W010-0801 PROP ANE GAS PILOT ASSEMBL Y 5* W573-0008 HIGH TEMPERA TURE SEALANT 6 W455-0069 NA TURAL GAS PILOT INJECTOR 6 W455-0067 PROP ANE GAS PILOT INJECTOR 7 W725-0025 NA TURAL ...

  • Continental Fireplaces BCDV42N - page 26

    26 W415-0385 / A / 10.02.03 ...

  • Continental Fireplaces BCDV42N - page 27

    27 W415-0385 / A / 10.02.03 Pilot will not light. - check if pilot can be lit by a match - check that the wire is connected to the push button ignitor . - check if the push button ignitor needs tightening. - replace the wire if the wire insulation is broken or frayed. - replace the electrode if the ceramic insulator is cracked or broken. - replace ...

  • Continental Fireplaces BCDV42N - page 28

    28 W415-0385 / A / 10.02.03 Pilot goes out while standing; Main burner is in 'OFF' position. Gas piping is undersized. - turn on all gas appliances and see if pilot flame flutters, dimin- ishes or extinguishes, especially when main burner ignites. Monitor appliance supply working pressure. - check if supply piping size is to code. Correct ...

Produzent Continental Fireplaces Kategorie Indoor Fireplace

Dokumente, die wir vom Produzenten des Geräts Continental Fireplaces BCDV42N erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Continental Fireplaces
- Bedienungsanleitungen BCDV42N
- Produktkarten Continental Fireplaces
- Informationsbroschüren
- oder Energieetiketten Continental Fireplaces BCDV42N
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Continental Fireplaces BCDV42N.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Continental Fireplaces BCDV42N, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Continental Fireplaces BCDV42N. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Continental Fireplaces BCDV42N ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Continental Fireplaces BCDV42N, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Continental Fireplaces BCDV42N hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Continental Fireplaces BCDV42N verständlich ist.

Eine gänzliche Bedienungsanleitung von Continental Fireplaces sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Continental Fireplaces BCDV42N bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Continental Fireplaces BCDV42N befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Continental Fireplaces BCDV42N, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Continental Fireplaces BCDV42N - die uns die ersten Schritte während der Nutzung von Continental Fireplaces BCDV42N erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Continental Fireplaces BCDV42N hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Continental Fireplaces BCDV42N im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Continental Fireplaces BCDV42N?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Continental Fireplaces BCDV42N nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Continental Fireplaces BCDV42N hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)