Bedienungsanleitung Lincoln Electric IM958

38 Seiten 1.02 mb
Download

Zur Seite of 38

Summary
  • Lincoln Electric IM958 - page 1

    INVER TEC V310-T A C/DC ® OPERA TOR’S MANUAL IM958 February, 2008 I N V E R T E C V 3 1 0- T A C / D C For use with machines having Code Numbers: 10943 • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's ...

  • Lincoln Electric IM958 - page 2

    FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. ________________________________________________ ...

  • Lincoln Electric IM958 - page 3

    ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4. b . Use suitable clothing made from durable flame-resistant material to protect your sk ...

  • Lincoln Electric IM958 - page 4

    FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8 . b . Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturerʼs recommendations. 8.c. Ground the equipment in accordance with the U.S. National Electrical ...

  • Lincoln Electric IM958 - page 5

    iv SAFETY iv Mar. ʻ93 PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A LʼArc 1. Protegez-vous contre la secousse électrique: a. Les c ...

  • Lincoln Electric IM958 - page 6

    v SAFETY v Electromagnetic Compatibility (EMC) Conformance Products displaying the CE mark are in conformity with European Community Council Directive of 3 May 1989 on the approximation of the laws of the Member States relating to electromagnetic compatibility (89/336/EEC). It was manufactured in conformity with a national standard that implements ...

  • Lincoln Electric IM958 - page 7

    vi SAFETY vi Electromagnetic Compatibility (EMC) The size of the surrounding area to be considered will depend on the structure of the building and other activities that are taking place. The surrounding area may extend beyond the boundaries of the premises. Methods of Reducing Emissions Mains Supply Welding equipment should be connected to the mai ...

  • Lincoln Electric IM958 - page 8

    vii vii T T h h a a n n k k Y Y o o u u for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it hand ...

  • Lincoln Electric IM958 - page 9

    viii viii T ABLE OF CONTENTS Page Installation ....................................................................................................................... Section A Technical Specifications .......................................................................................................A-1 Select Suitable Location ................ ...

  • Lincoln Electric IM958 - page 10

    A-1 INST ALLA TION V310-T AC/DC TIG A-1 Input Current @ Rated Output 7.3A 8.3A 12.3A 9.6A 10.7A 13.8A 13.9A 15.8A 24.6A 18.7A 20.9A 27.7A 15.3A 17.5A 27.3A 20.5A 23.6A 30.8A 13.6A 14.9A 23.1A 17.2A 19.4A 25.7A 21.9A 24.6A 41.5A 29.2A 33.2A 47.1A 24.2A 27.7A 47.3A 32.1A 37.3A 52.5A Rated Output Current, Voltage, Duty Cycle (104°F, 40°C) 210A / 18. ...

  • Lincoln Electric IM958 - page 11

    A-2 INST ALLA TION V310-T AC/DC TIG A-2 MACHINE GROUNDING AND HIGH FRE- QUENCY INTERFERENCE PROTECTION The Capacitor Discharge Circuit used in the high fre- quency generator, may cause many radio, TV and el ec tr on ic e qu ip me nt in te rf er en ce p ro bl em s. Th es e problems may be the result of radiated interference. Proper grounding methods ...

  • Lincoln Electric IM958 - page 12

    A-3 INST ALLA TION V310-T AC/DC TIG A-3 5. The work terminal must be connected to a ground within ten feet of the welder, using one of the fol- lowing methods. a) A metal underground water pipe in direct con- tact with the earth for ten feet or more. b) A 3 / 4 ” ( 1 9 m m ) g a l v a n i z e d p i p e o r a 5 / 8 ” (16mm) solid galvanized iron ...

  • Lincoln Electric IM958 - page 13

    A-4 INST ALLA TION V310-T AC/DC TIG A-4 INPUT PLUG INST ALLA TION POWER CORD CONNECTION A 10 f t. p o we r co rd i s pr o vi de d a nd w ir ed i nt o t he machine. Follow the power cord connection instruc- tions. Single Phase Input Connect green lead to ground per National Electrical Code. Connect black and red leads to power. Wrap white lead with ...

  • Lincoln Electric IM958 - page 14

    OUTPUT CONNECTIONS ELECTRIC SHOCK can kill. • Insulate yourself from work and ground. • Turn the input line Switch on the Invertec V310T AC/DC “off” before connecting or disconnecting output cables or other equipment. • Keep the electrode holder, TIG torch and cable insulation in good condition and in place. • Do not touch electrically ...

  • Lincoln Electric IM958 - page 15

    A-6 INST ALLA TION V310-T AC/DC TIG A-6 REMOTE CONTROL CONNECTION A remote control receptacle is provided on the lower center case front of the welder for connecting a remote control to the machine. Refer to the Optional Accessories section of this manual for available remote controls. CYLINDER could explode if damaged. • Keep cylinder upright an ...

  • Lincoln Electric IM958 - page 16

    B-1 OPERA TION V310-T AC/DC TIG B-1 Read and understand this entire section before operating your machine. SAFETY INSTRUCTIONS ELECTRIC SHOCK can kill. • Do not touch electrically live parts such as output terminals, electrode or internal wiring. • Insulate yourself from the work and ground. • Always wear dry insulating gloves. ______________ ...

  • Lincoln Electric IM958 - page 17

    B-2 OPERA TION B-2 REAR CONTROL P ANEL (FIGURE B.1) • I1: Off/On switch turns on the electric power to the welder. It has two positions, "O" off, and "I" on. ------------------------------------------------------------------------ * With "l1" i n t h e "I" (ON) position, t he welding machine is operational ...

  • Lincoln Electric IM958 - page 18

    B-3 OPERA TION B-3 V310-T AC/DC TIG The V310-T AC/DC User interface consists of the following (Refer to Figure B.3): 1. DYNAMIC LCD DISPLAY 2. STATUS LED LIGHTS a . VRD On (Voltage Reduction Device) Status Light - Voltage reduction device can be enabled from the set-up menu so that an output voltage limit can be set that reduces the output open cir ...

  • Lincoln Electric IM958 - page 19

    B-4 OPERA TION B-4 D YNAMIC LCD D ISPLA Y The D ynamic display is div ided into several sec tions (Refer to Figure B.4): Figure B.4 1. The Weld Sequence Diagram shows the various parameters that can be selected and adjusted and their preset values. As the push button/rotary encoder is pressed a triangular shaped flashing indicator will highlight th ...

  • Lincoln Electric IM958 - page 20

    B-5 OPERA TION B-5 3. The Mode Push Buttons and Indicators show the current selection made by the corresponding weld push buttons (A-F). Refer to Table B.2 for a full list of all parameters and their ranges. Below is a description of the function of each push button and display: Two-Step with Foot Pedal - This mode is only available when the machin ...

  • Lincoln Electric IM958 - page 21

    B-6 OPERA TION B-6 Bi-Level Current – (If Enabled from th e S etu p M enu ) D epr ess ing an ar c start switch and releasing will initiate the arc to current level A1. Depressing and releasing the arc Start switch again will toggle to cur- rent level A2. Each depressing and releasing of the switch will toggle between A1 and A2. Depressing and hol ...

  • Lincoln Electric IM958 - page 22

    B-7 OPERA TION B-7 V310-T AC/DC TIG WELDING P ARAMETERS The following parameters are adjustable on the V310-T AC/DC. (See Table B.3) Table B.3 Parameter Name Pre-Flow Start Current Finish Current Min. Current Upslope Downslope Spot Time Max. Current Pulse Frequency Background Current % Peak Time Postflow AC Frequency AC Balance Hot Start Arc Force ...

  • Lincoln Electric IM958 - page 23

    B-8 OPERA TION B-8 V310-T AC/DC TIG USER MENU SET UP P ARAMETERS Many additional parameters can be modified via the Set Up Menu. To access the Set Up Menu press and hold the rotary encoder knob for several seconds until the following screen appears: (See figure B.7) FIGURE B.7 Rotating the encoder knob will scroll through the setup parameters shown ...

  • Lincoln Electric IM958 - page 24

    B-9 OPERA TION B-9 V310-T AC/DC TIG 0 A2 VRD Selection/ * Default Value NA % * Amps % Amps* % * Amps % Amps* 15 amps* 60 amps* 30 amps* Enabled* Disabled Enabled Disabled* Square* Sine Triangle Enabled Disabled * Enabled Disabled * 0ff* Enabled to 12V Enabled to 20V Enabled to 30V 0 to 10 10* -20 to 20 10* English* French Spanish Parameter Symbol S ...

  • Lincoln Electric IM958 - page 25

    B-10 OPERA TION B-10 V310-T AC/DC TIG T ABLE B.4 (Continued) SET UP MENU P ARAMETERS Selection/ * Default Value Display Off Display in 7 Segment LED Display* Display Off* Display in 7 Segment LED Display Display Off* Display in 7 Segment LED Display Display Off* Display in 7 Segment LED Display This function sets the initial start energy limit. Set ...

  • Lincoln Electric IM958 - page 26

    B-11 OPERA TION B-11 TIPS FOR IMPROVED TIG ST ARTING 1. Start Current: For the best AC or DC TIG starting characteristics it may be nec essary to adjust the start current on the front panel depending on the tungsten size. In gener- al, larger tungsten requires more energy to establish an arc than smaller tungsten. As an initial guideline, set the s ...

  • Lincoln Electric IM958 - page 27

    C-1 ACCESSORIES C-1 OPTIONAL ACCESSORIES AND COMP A TIBLE EQUIPMENT Field Installed K857 - Remote Output Control - For Stick welding. Portable current control provides the same range as the current control on the welder. Consists of a 6-pin connector which plugs into the remote control connec- tor. 25 foot cable length. K870 - Foot Amptrol t m for ...

  • Lincoln Electric IM958 - page 28

    C-2 ACCESSORIES C-2 CABLE PLUGS K852-70 - Cable Plug Kit for 1/0-2/0 cable. Attaches to welding cable to provide quick disconnect from machine. K1622-1 Twist-Mate adapter for PTA-9 & 17 Air- Cooled TIG torches – Adapter for PTA-9 or PTA-17 TIG torches with one-piece cable. The quick connect plug provides connection for both gas and welding cu ...

  • Lincoln Electric IM958 - page 29

    D-1 MAINTENANCE D-1 V310-T AC/DC TIG SAFETY PRECAUTIONS ELECTRIC SHOCK can kill. • Have an electrician install and ser- vice this equipment. • Turn the input power off at the fuse box, disconnect or unplug supply lines and allow machine to sit for five minutes minimum to allow the power capacitors to dis- charge before working inside this equip ...

  • Lincoln Electric IM958 - page 30

    E-1 TROUBLESHOOTING E-1 V310-T AC/DC TIG This Troubleshooting Guide is provided to help you locate and repair possible machine malfunctions. Simply follow the three-step procedure listed below. Step 1. LOCATE PROBLEM (SYMPTOM). Look under the column labeled “PROBLEM (SYMP- TOMS)”. This column describes possible symptoms that the machine may exh ...

  • Lincoln Electric IM958 - page 31

    E-2 TROUBLESHOOTING E-2 V310-T AC/DC TIG Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBLE ...

  • Lincoln Electric IM958 - page 32

    E-3 TROUBLESHOOTING E-3 V310-T AC/DC TIG Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBLE ...

  • Lincoln Electric IM958 - page 33

    E-4 TROUBLESHOOTING E-4 V310-T AC/DC TIG Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBLE ...

  • Lincoln Electric IM958 - page 34

    E-5 TROUBLESHOOTING E-5 V310-T AC/DC TIG The V310-T ACDC, when a fault condition is detected, dis- plays on the graphics LCD an alarm notification composed of: ALARM ICON + ALARM CODE + ALARM TYPE ICON Exx When a fault condition is detected, the power source and the cooler are switched in safety mode, it means the welding operation are stopped. To ...

  • Lincoln Electric IM958 - page 35

    F-1 WIRING DIAGRAMS F-1 NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code number. V310 ...

  • Lincoln Electric IM958 - page 36

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES. SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL F ABRICANTE P ARA EL ...

  • Lincoln Electric IM958 - page 37

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIPAMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR. ● Keep yo ur h ead out of fum es. ● Use ven tila tio n or exh aus t to remo ve ...

  • Lincoln Electric IM958 - page 38

    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • ...

Produzent Lincoln Electric Kategorie Welder

Dokumente, die wir vom Produzenten des Geräts Lincoln Electric IM958 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Lincoln Electric
- Bedienungsanleitungen IM958
- Produktkarten Lincoln Electric
- Informationsbroschüren
- oder Energieetiketten Lincoln Electric IM958
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Lincoln Electric IM958.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Lincoln Electric IM958, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Lincoln Electric IM958. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Lincoln Electric IM958 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Lincoln Electric IM958, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Lincoln Electric IM958 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Lincoln Electric IM958 verständlich ist.

Eine gänzliche Bedienungsanleitung von Lincoln Electric sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Lincoln Electric IM958 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Lincoln Electric IM958 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Lincoln Electric IM958, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Lincoln Electric IM958 - die uns die ersten Schritte während der Nutzung von Lincoln Electric IM958 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Lincoln Electric IM958 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Lincoln Electric IM958 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Lincoln Electric IM958?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Lincoln Electric IM958 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Lincoln Electric IM958 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)