    TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT -SYSTEM COOLING & HEA T PUMPS MODELS: AHP18 THRU 60 AND SHP48 THRU 60 Due to continuous product im provement, specifications are subjec t to ch a nge without notic e. V isit us on the web at www .york.com Additional rati ng information ca n be found at www .ari.org/ari directory . ISO ...

  • York AHP18 THRU 60 - page 2

    255029-YTG-J-1007 2 Unitary Products Group DIMENSIONS 10-3/8” F CIRCUIT BREAKER P ANEL BOTTOM INLET DIMENSIONS DRAIN P AN CONNECTIONS FOR HORIZONT AL APPLICATIONS J BLOWER COMP ARTMENT REFRIGERANT CONNECTIONS DRAIN CONNECTIONS FOR UPFLOW AND DOWNFLOW APPLICA TIONS 7-1 1/32” D B A K C 1-1/2” 18-9/32” E TOP OUTLET DIMENSIONS FIL TER ACCESS DI ...

  • York AHP18 THRU 60 - page 3

    255029-YTG-J-1007 Unitary Products Group 3 COOLING CAP ACITY Models Rated CFM Entering Air °F (Dry / Wet Bulb) MBH@ Evaporator T emperature and Corresponding Pressure °F / PSIG 35 / 61.5 40 / 68.5 45 / 76.0 50 / 84.0 FULL-CASED “A” TYPE MUL TI-POSITION AHP18B2A(N,H)21 650 85/72 24.5 22.3 19.9 17.3 80/67 22.6 20.3 18.0 15.6 75/62 18.5 16.4 14. ...

  • York AHP18 THRU 60 - page 4

    255029-YTG-J-1007 4 Unitary Products Group ACCESSORIES Refer to Price Manual for specific model numbers. TXV Kits - TXV kits are available for “Flex-coil” applica tions and converting R22 to R410A or as a service replacement. All kits are bolt-on and require no brazing to install. Non-Combustible Bases - A combustible floor base acces- sory is ...

  • York AHP18 THRU 60 - page 5

    255029-YTG-J-1007 Unitary Products Group 5 All air handle r units are UL Liste d up to 0.50" w.c. external static press ure, incl ud ing air fil ter , wet coil, an d l argest KW s ize heater, unless otherwise noted. AIR FLOW DA T A - 60 Hz MODELS Models Blower Motor Speed 230 V olt CFM 1 @ External St atic Pressure - IWC 0.10 0.20 0.30 0.40 0. ...

  • York AHP18 THRU 60 - page 6

    255029-YTG-J-1007 6 Unitary Products Group PHYSICAL & ELECTRICAL DA T A Models AHP18B**(N,H)21 AHP24B**(N,H)21 AHP30B**(N,H)21 AHP36C **(N,H)21 Blower - Diameter x Width 9 x 6 10 x 9 10 x 9 10 x 10 Motor HP 1/3 HP 1/4 HP 1/2 HP 3/4 HP Nominal RPM 1075 1075 1075 1075 V oltage 230 Amps Full Load ( 230) 1.9 1.5 2.2 3.6 Filter 1 T ype DISPOSABLE OR ...

  • York AHP18 THRU 60 - page 7

    255029-YTG-J-1007 Unitary Products Group 7 * May be 0 (no breaker) or 1 (with breaker). ELECTRICAL DA T A - 208/230-1-60 Models Heater Models* Max. Static Min. Speed Ta p T otal Heat 1 kW St a ging kW MBH W1 Only W2 Only W1 + W2 208V 240V 208V 2 40V 208V 240V 208V 240V 208V 240V AHP18B**(N,H)21 4HK*6500206 0.5 Lo 1.9 2.5 6.4 8.5 1.9 2.5 1 .9 2.5 1. ...

  • York AHP18 THRU 60 - page 8

    255029-YTG-J-1007 8 Unitary Products Group * May be 0 (no breaker) or 1 (with breaker). ELECTRICAL DA T A (FOR SI NGLE SOURCE POWER SUPPL Y) - COPPER WIRE 208/230-1-60 Models Heater Models* Heater Amps 240V Field Wiring Min. Circuit Ampacity Max. O.C.P . 1 Amps/T ype 75 ° C Wire Size - AWG 208V 240V 208V 2 40V 208V 240V AHP18B**(N,H)21 4HK*6500206 ...

  • York AHP18 THRU 60 - page 9

    255029-YTG-J-1007 Unitary Products Group 9 ELECTRICAL DA T A (FOR MUL TI SOURCE PO WER SUPPL Y) - COPPER WIRE 208/230-1-60 Models Heater Models Min. Circuit Ampacity Max. O.C.P . 1 Amp s/T ype 75 ° C Wire Size - A WG Circuit Circuit Circuit 1st 2nd 3rd 1st 2nd 3rd 1st 2nd 3rd 208/240 208/240 208/240 208/240 208/240 208/240 208/240 208/240 208/240 ...

  • York AHP18 THRU 60 - page 10

    255029-YTG-J-1007 10 Unitary Products Group 2. Heaters are 3 Phase. ELECTRICAL DA T A (FOR SI NGLE SOURCE POWER SUPPL Y) - COPPER WIRE 208/230-3-60 Models Heat Kit - Three Phase Heater Amps 240V Field Wiring Min. Circuit Ampacity Max. O.C.P . 1 Amp s/T ype 75 ° C Wire Size - A WG 208V 240V 208V 2 40V 208V 240V AHP24B**(N,H)21 4HK06501025 23.1 27.1 ...

  • York AHP18 THRU 60 - page 11

    255029-YTG-J-1007 Unitary Products Group 11 COOLING MODELS W ITH ELECTRIC HEA T WI RING * O ptional dehumidification humidistat switch contacts open on humidity rise. Notes: 1. “Y” T erminal on Air Handler Control Boa rd must be connecte d for full CFM and applications requiring 60 second blower off del ay for SEER enhancement. 2. Move HUM ST A ...

  • York AHP18 THRU 60 - page 12

    Subject to change without notice. Printe d in U.S.A. 255029-YTG-J-1007 Copyright © by Unitary Products Gr oup. 2007. All rights reserved. Supersedes: 255029-YTG-I-0507 Unitary 5005 Norman Product s Y ork OK Group Drive 73069 TYPICAL APPLICA TIONS UPFLOW DOWNFLOW HORIZONT AL RIGHT HORIZONT AL LEFT ...

Produzent York Kategorie Heat Pump

Dokumente, die wir vom Produzenten des Geräts York AHP18 THRU 60 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen York
- Bedienungsanleitungen AHP18 THRU 60
- Produktkarten York
- Informationsbroschüren
- oder Energieetiketten York AHP18 THRU 60
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung York AHP18 THRU 60.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen York AHP18 THRU 60, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen York AHP18 THRU 60. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts York AHP18 THRU 60 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts York AHP18 THRU 60, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von York AHP18 THRU 60 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von York AHP18 THRU 60 verständlich ist.

Eine gänzliche Bedienungsanleitung von York sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von York AHP18 THRU 60 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von York AHP18 THRU 60 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich York AHP18 THRU 60, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts York AHP18 THRU 60 - die uns die ersten Schritte während der Nutzung von York AHP18 THRU 60 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit York AHP18 THRU 60 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von York AHP18 THRU 60 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich York AHP18 THRU 60?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit York AHP18 THRU 60 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit York AHP18 THRU 60 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)