Bedienungsanleitung Dimplex DFI2309

16 Seiten 0.34 mb
Download

Zur Seite of 16

Summary
  • Dimplex DFI2309 - page 1

    PARTS AND SERVICE MANUAL FOR THE 23” INSERT FIREPLACE MODEL NUMBER: DFI2309 ...

  • Dimplex DFI2309 - page 2

    TABLE OF CONTENTS O P E R A T I O N P A G E 1 PARTS DRAWING PAGE 3 P A R T S L I S T P A G E 4 WIRING DIAGRAM PAGE 5 LIGHT BULB REPLACEMENT PAGE 6 MAIN ON/OFF SWITCH REPLACEMENT PAGE 8 LOW HEAT ON/OFF SWITCH REPLACEMENT PAGE 9 HIGH HEAT ON/OFF SWITCH REPLACEMENT PAGE 10 FLAME MOTOR/FLAME ROD REPLACEMENT PAGE 11 HEATER ASSEMBLY REPLACEMENT PAGE 12 L ...

  • Dimplex DFI2309 - page 3

    1 DFI2309 OPERATION MAIN ON/OFF FLAME ON/OFF SWITCH The ON/OFF switch supplies power to all unit functions. When this switch is in the ON position the flame effect operates without heat. LOW HEAT SWITCH The LOW HEAT ON/OFF SWITCH supplies power to the heat er fan and the heater element. When the switch is in the ON position the heater operates on L ...

  • Dimplex DFI2309 - page 4

    2 DFI2309 REMOTE CONTROL The remote control has a range of approxim ately 50ft. (15.25m) it does not have to be pointed at the fireplace and can pass through most obstacles (including walls). It is supplied with one of 243 i ndependent frequencies to prevent interference with other units. The frequency designation is indicate d on the back of the t ...

  • Dimplex DFI2309 - page 5

    3 DFI2309 10 9 6 4 11 1 2 3 7 8 5 12 ...

  • Dimplex DFI2309 - page 6

    4 DFI2309 REPLACEMENT PARTS 23” FIREPLACE INSERT REPLACEMENT PART REPLACEMENT PART NO. 1. MAIN ON/OFF SWITCH 2800090100RP* 2. LOW HEAT ON/OFF SWITCH 2800090100RP* 3. HIGH HEAT ON/O FF SWITCH 2800090100RP* 4. CORDSET 4100090101RP 5. HEATER ASSEMBLY 2200490300RP 6. CUTOUT 2300270200RP 7. MIRROR 5900350100RP 8. LOGSET 0438200200RP 9. FLICKER MOTOR 2 ...

  • Dimplex DFI2309 - page 7

    5 DFI2309 WIRING DIAGRAM ...

  • Dimplex DFI2309 - page 8

    6 DFI2309 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. Light bulbs need to be replaced when you notice a dark section o ...

  • Dimplex DFI2309 - page 9

    7 DFI2309 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. BULB REQUIREMENTS Quantity 2 clear chandelier or candelabra bulb ...

  • Dimplex DFI2309 - page 10

    8 DFI2309 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE MAIN ON/OFF SWITCH 1. Remove the trim and firebox fro ...

  • Dimplex DFI2309 - page 11

    9 DFI2309 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE LOW HEAT ON/OFF SWITCH 1. Remove the trim and firebox ...

  • Dimplex DFI2309 - page 12

    10 DFI2309 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE HIGH HEAT ON/OFF SWITCH 1. Remove the trim and fireb ...

  • Dimplex DFI2309 - page 13

    11 DFI2309 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE FLAME MOTOR/FLAME ROD 1. Remove the trim and firebox ...

  • Dimplex DFI2309 - page 14

    12 DFI2309 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE HEATER ASSEMBLY 1. Remove the trim and firebox from ...

  • Dimplex DFI2309 - page 15

    13 DFI2309 If unit was operating prior to servicing allo w at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE LIGHT HARNESS 1. Remove the trim and firebox from m ...

  • Dimplex DFI2309 - page 16

    14 DFI2309 If unit was operating prior to servicing allow at least 10 minutes for light bulbs and heating element to cool off to av oid accidental burning of skin. Disconnect power before attempting any main tenance or cleaning to reduce the risk of electric shock or damage to persons. TO REPLACE POWER CORD 1. Remove the trim and firebox from mante ...

Produzent Dimplex Kategorie Indoor Fireplace

Dokumente, die wir vom Produzenten des Geräts Dimplex DFI2309 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Dimplex
- Bedienungsanleitungen DFI2309
- Produktkarten Dimplex
- Informationsbroschüren
- oder Energieetiketten Dimplex DFI2309
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Dimplex DFI2309.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Dimplex DFI2309, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Dimplex DFI2309. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Dimplex DFI2309 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Dimplex DFI2309, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Dimplex DFI2309 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Dimplex DFI2309 verständlich ist.

Eine gänzliche Bedienungsanleitung von Dimplex sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Dimplex DFI2309 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Dimplex DFI2309 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Dimplex DFI2309, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Dimplex DFI2309 - die uns die ersten Schritte während der Nutzung von Dimplex DFI2309 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Dimplex DFI2309 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Dimplex DFI2309 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Dimplex DFI2309?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Dimplex DFI2309 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Dimplex DFI2309 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)