    Mitsubishi Ele ctric Buildin g A ir-conditioner Control Sy stem Central Controller G-50A/GB-50A Operation M anual for Initial Setting Web Contents 1 Introduc tion .........................................................................1 1-1 Convent ions Used i n This Ma nual ........................................... 1 1-2 Computer Re quirem ents ...

  • Mitsubishi Electronics GB-50A - page 2

    1 1 Introduction A spec ial f eature of Mits ubishi Electr ic Cor porat ion’s “Centra l Contro ller G -50A” a nd "C entral Contr oller GB-50A" are tha t a PC c onnec ted to a LAN ca n be used to m onitor the oper atio n condit ion of a ir condi tioners , perform air c onditioner oper ations, and m ake initia l sett ings. This docum ...

  • Mitsubishi Electronics GB-50A - page 3

    2 2 Setting the Operating Env i ronment Given below is an expl anation of the PC setti ngs and web bro wser setti ngs that are req uired f or using a web browser to m onitor air con ditioner u nits and perfor m oper ations. 2-1 Setting t he PC IP A ddress You need to s et an IP addr ess on the PC that w ill enable you to con nect to the G- 50A usin ...

  • Mitsubishi Electronics GB-50A - page 4

    3 (4) In the [Int ernet Protoc ol (T CP/IP) Prop erties] dia log, click [Use the follo wing IP ad dress] an d enter th e IP a ddress ( for ex ample, “192.168. 1.101”) that you want to set in the IP a ddress field. You norm ally set [2 55.255. 255.0] as t he sub net mas k. Note: A sk your LAN administrat or to provide the IP addresses and subnet ...

  • Mitsubishi Electronics GB-50A - page 5

    4 2-2 Setting t he Web Brow ser Perform the necess ary web br owser sett ings t o enable the web bro wser to co nnect to the G-50 A. Note: The settings and screen images used as examples in this manual are based on Internet Explorer 6.0. 2-2-1 N ot connecting to t he Internet If the PC you use f or m onitoring a ir condi tioners and p erform ing op ...

  • Mitsubishi Electronics GB-50A - page 6

    5 2-2-3 C onnecting to the Internet using a proxy server (Using an exist ing LA N) If the PC you use for monit oring a ir cond itioners and perf orm ing operations is goi ng to acces s the Intern et vi a prox y ser ver by c onnecting to an ex isting L AN such a s a LAN within your com pany, use the proc edure gi ven below to s et the we b browser e ...

  • Mitsubishi Electronics GB-50A - page 7

    6 3 Performing Operations Given be low is an explana tion of ho w to conn ect to the G-50A a nd how to m ak e various sett ings for the G-50A . Note: If the G-50A is restarted due to circumstanc es like a pow er interrupti on, w ait until the screen on the G-50A main unit displays t he normal operation screen (it takes several minut es before the n ...

  • Mitsubishi Electronics GB-50A - page 8

    7 4 Initial Settings 4-1 Setting t he Curr ent Date and Time Click [Initial Se ttings] i n the m enu, and [Date and T ime] sc reen will appe ar on the s creen. Enter the curren t date and tim e, and then pre ss the [Sav e Settings ] butto n to send t he current date a nd tim e to G-50A. Note: If the user logs in as a building manager, the operation ...

  • Mitsubishi Electronics GB-50A - page 9

    8 4-2 Setting t he Basic Inf ormation a nd External I nput Func tions Displa y the page n eeded t o per form the G -50A basic setting b y click ing [In itial Sett ings]-[ Basic S ystem ] in the setting m enu pane. On t his page , you per f orm the bas ic s etting s uch as th e G - 50 A un it nam e, networ k setting and M-NET setting. Click [Save Se ...

  • Mitsubishi Electronics GB-50A - page 10

    9 4-2-2 M-NET S etting In M-NET Setting, set t he G-50A M-NET address , whether or not a K- Contro l unit is prese nt and which machines send th e prohib ited contr oller comm and. (1) Enter the G-5 0A M-NET address i n the [M-N ET Ad dress ] field. Nor mall y you shou ld enter [ 0]. (2) W hen K-Contr ol air c onditio ners are c onnect ed, c lick [ ...

  • Mitsubishi Electronics GB-50A - page 11

    10 4-2-3-1 Settings for when the G-50A is connected t o a dedicated LA N (1) Enter the G-5 0A IP ad dress in t he [IP A ddress] f ield. If the LAN wiring has been n ewly set up, allocat e IP addresses to t he G -50 A un i ts in a s eq uen tia l ord er s tarting wit h [192.1 68.1 .1]. F or exam ple the f irs t G -50 A unit will rece ive an IP addr e ...

  • Mitsubishi Electronics GB-50A - page 12

    11 4-2-3-2 Settings for when the G-50A is connected t o an existing LA N W hen connectin g the G-5 0A to a n existi ng LAN, cons ult with the ne twork adm inistrator who is res ponsib le for the LAN bef ore sett ing the I P addres s, subn et mask , or gatewa y address . [Exam ple of a Per manent L AN System ] 4-2-4 External Input Settin g In the Ex ...

  • Mitsubishi Electronics GB-50A - page 13

    12 (4) Se lecting [ON/OF F/Prohib it/Per mit ( Pulse s ignal)] m akes it po ssible t o use pulse s ignals to ru n m ultiple units, st op multiple units, pr ohibit loca l operation an d perm it local operati on. In this m ode, it is pos sible to freel y operate the r emote c ontrol exc ept duri ng the pul se signa l input. 4-2-5 Set ting the Display ...

  • Mitsubishi Electronics GB-50A - page 14

    13 4-3 Group Se tting Displa y the page neede d to register the gr oup of air condit ioner s to be conn ected to the G-50 A and to s et the group nam e by click ing [Initi al Settings ]-[Grou ps]. On this page, you perf orm the basic s etting such as the G-50A u nit nam e, network setting an d M-NET setting . Click [Set to G -50A] to send setti ng ...

  • Mitsubishi Electronics GB-50A - page 15

    14 (2) T o register r emote c ontrollers i n a grou p, clic k on the [Rem ote Controll er Registr ation] fiel d to displ ay the [S elect U nit Addr esses] screen, an d clic k on the num bers c orrespondin g to the units to be registere d. The ones that are sel ected wil l be s hown with a yellow-gr een bac kgr ound. T o cancel the s electi on, clic ...

  • Mitsubishi Electronics GB-50A - page 16

    15 4-4 Interlocked S etting To interloc k the op eratio n of LOSS NAY with the r un/stop sta tus of the indoor units, c lick on [In itial Settings]- [Interloc ked LO SSNAY] in the m enu to brin g up the Interloc ked LO SSNAY screen, a nd enter th e interlock conditi ons. Clic k [Sa ve Settin gs] to se nd setti ng data t o the G-50 A. Note: If the u ...

  • Mitsubishi Electronics GB-50A - page 17

    16 4-5 Block Se tting By perf orm ing block setting s, m ultiples of air con ditio ner gr oups ca n be col lectivel y m onitored or operated fr om the W eb or T G-2000A. It a lso ena bles en erg y-save/peak cut c ontrols . Bring up the Bloc k Sett ing sc reen b y clicking [Initial Settings]-[B locks] in the menu, and register the groups in the bloc ...

  • Mitsubishi Electronics GB-50A - page 18

    17 5 Functions 1 5-1 Error mail repor ts/E-mail comm unication Click on [Functions 1] – [ E-Mai l] in the m enu to open the [E-m ail] win dow and mak e necessar y settings to perform rem ote monitori ng via m ail, usi ng error mail r eport or t he mainte nance too l. Click [Save Sett ings] to s end setti ng data to t he G-5 0A. Note: The use of t ...

  • Mitsubishi Electronics GB-50A - page 19

    18 5-1-2 Setti ng the Mail Serve r Information Enter the m ail ser ver infor m ation provided b y either t he ISP or the LAN adm inistr ator. Either t he IP a ddress or th e host n am e (server nam e) can be entered i n the m ail serv er field. Make nec essar y settings d ependi ng on the f unctions t o be us ed, usin g the tabl e belo w as a ref e ...

  • Mitsubishi Electronics GB-50A - page 20

    19 (4) T o e-mail an error when an er ror occ urs on g enera l equipm ent connected to PLC for genera l equipment, click the PLC Connection butto n, which appe ars at the tim e of s election of "G enera l Equipm ent", to s et the IP addr ess of PLC f or gener al equi pment. The row n um ber of the s et IP ad dress will b e in a n error m ...

  • Mitsubishi Electronics GB-50A - page 21

    20 5-2 Energ y-Save Control a nd Peak Cut Con trol Click on [Functions 1] – [ Peak Cut] in the m enu to bring up th e peak c ut control scr een, and mak e necessar y peak c ut settings to use the energ y-save or peak c ut control f unction. Click [Save Sett ings] to s end setti ng data to t he G-5 0A. Note: The use of energy-save/peak cut control ...

  • Mitsubishi Electronics GB-50A - page 22

    21 5-2-1 Init ialization of the PLC (When the PLC i s in use) Before us ing the P LC Sof tware for demand inp ut or Ele ctric Amount Count Soft ware, clic k on the PLC initi alize button onc e to in itialize t he intern al m emor y. Note: Do not initialize the memory after the op eration has begun, for it will clear all operation data. 5-2-2 Settin ...

  • Mitsubishi Electronics GB-50A - page 23

    22 5-2-6 Setting the Outdoor Unit Control Method (A ll methods) Make the e nerg y-save cont rol sett ing for th e outdo or units f or each e nerg y-save leve l. Note: M-NET addresses are displayed on outdoor uni ts of City multi type. M-NET addresses and group names are displayed on A-control units (Slim units ). Note: As f or A-control outdoor uni ...

  • Mitsubishi Electronics GB-50A - page 24

    23 5-2-7 Setting the Indoor Unit Control Method (All methods) Make the e nerg y-save cont rol sett ings for the outdoor units f or each energ y-save le vel. The s ettings ar e m ade for each o perat ion b lock . If the oper atio n bloc ks have no t been set up, ref er to s ecti on 4-5 on how to set the operation bloc k s . (1) Set the contr ol m et ...

  • Mitsubishi Electronics GB-50A - page 25

    24 6 Functions 2 6-1 Limi ting the Set Tem perature Operati ng Rang e Click on [Functi on2]-[S et T emperature Ra nge L imit] in t he m enu to op en the set tem perature r ange l im it screen, and m ak e necessar y settings to lim it the set tem peratur e operat ing range of the loca l rem ote controller. Each us er opera tion will b e lim ited by ...

  • Mitsubishi Electronics GB-50A - page 26

    25 6-2 Night Mo de Schedule Click on [Funct i on2]-[Ni ght Mode Sc hedule] in th e menu t o ope n the n ight m ode schedule screen and m ake necessar y settings t o sw itc h the outdoor un it operat ion m ode to th e n ight m ode (l o w-n oise oper at io n) , an d s et the night m ode tim e inter val. Use this m ode wh en low-n oise oper ation of t ...

  • Mitsubishi Electronics GB-50A - page 27

    26 6-3 Auto-C hangeover of Y serie s Click on [Funct ion2]-[ Auto-chang eover ] in th e m enu to open the a uto-change over screen an d m ake necess ary settings to switch th e opera tion m ode between c ooling and h eating automatic all y of the indo or units connected to the sam e outdoor unit. S et the chan ge over mode and th e target u nits. P ...

  • Mitsubishi Electronics GB-50A - page 28

    27 7 User Setting Click on [Us er s ettin gs ] in t he m enu to ope n the user s etti ng sc r een an d m ake nec ess ar y user settin gs to lim it availab le functions of a bu ilding m anager an d to chang e user nam es and p asswords of m aintenance user an d building m anag er. A build ing m anager m ust chang e group n am es when a tenant has be ...

  • Mitsubishi Electronics GB-50A - page 29

    28 Table 7- 1 Avai lable F unctio n List Function Content Date and ti me Current date and time se tting Basic sy stem *1 G- 50A network setti ng, ex ternal output set ting Group name Group name sett ing Groups Group str ucture *1 Connec tion setting o f indoor unit s, remote contro llers and system controller s in a gr oup Interlocked LOSSN AY *1 C ...

  • Mitsubishi Electronics GB-50A - page 30

    29 8 Registering a License fo r Optional F unction Given be low is an ex planati on on ho w to register a licens e for option al func tions. I n the Login s creen (s ee3-1), click [License r egistrat ion for optional func tions] an d the Licens e Registr ation of Option al Functio ns sc reen will appear. Please as k the dea ler you purchased t he p ...

  • Mitsubishi Electronics GB-50A - page 31

    W T04526X04 HEAD OFFICE: MITSUBISHI DENKI BLDG., 2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN ...

Produzent Mitsubishi Electronics Kategorie Air Conditioner

Dokumente, die wir vom Produzenten des Geräts Mitsubishi Electronics GB-50A erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Mitsubishi Electronics
- Bedienungsanleitungen GB-50A
- Produktkarten Mitsubishi Electronics
- Informationsbroschüren
- oder Energieetiketten Mitsubishi Electronics GB-50A
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Mitsubishi Electronics GB-50A.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Mitsubishi Electronics GB-50A, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Mitsubishi Electronics GB-50A. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Mitsubishi Electronics GB-50A ansehen.

Die komplette Bedienungsanleitung des Geräts Mitsubishi Electronics GB-50A, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Mitsubishi Electronics GB-50A hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Mitsubishi Electronics GB-50A verständlich ist.

Eine gänzliche Bedienungsanleitung von Mitsubishi Electronics sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Mitsubishi Electronics GB-50A bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Mitsubishi Electronics GB-50A befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Mitsubishi Electronics GB-50A, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Mitsubishi Electronics GB-50A - die uns die ersten Schritte während der Nutzung von Mitsubishi Electronics GB-50A erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Mitsubishi Electronics GB-50A hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Mitsubishi Electronics GB-50A im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Mitsubishi Electronics GB-50A?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Mitsubishi Electronics GB-50A nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Mitsubishi Electronics GB-50A hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)