Bedienungsanleitung Extech Instruments 42265

22 Seiten 0.85 mb
Download

Zur Seite of 22

Summary
  • Extech Instruments 42265 - page 1

    SW276 User Guide Model 42265 Temperature Datalogger Kit Model 42275 Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software ...

  • Extech Instruments 42265 - page 2

    V7.1 1/08 2 Introduction Congratulations on your purchase of Extech Instrument’s Datalogging instrumentation and software. This User Guide serves th ree purposes, refer to t he list below: 1. This User Guide covers the following products entirel y with regard to hardware an d software operation: Model 42275: Temperature and Humidity Datalogging M ...

  • Extech Instruments 42265 - page 3

    V7.1 1/08 3 REC HI LOW COMM RH% °C °F Description 1. LCD display 2. Mounting hole 3. Docking station 4. Interface Cable 5. Status LEDs 6. Software CD Displays LCD Display REC: Displayed while logging readings. Read the ‘Recording Status’ section for further details. HI and LOW: Displayed when the High or Low Alarm limit is exceeded. See ‘Al ...

  • Extech Instruments 42265 - page 4

    V7.1 1/08 4 1 2 3 4 5, 6 7 8 Software Installation Installation instructions f or models 42266 and 42276 Note: The softw are program and USB dri ver must both b e installed in ord er for the printer/meter to communicate w ith the software. Please follow the installation inst ructions below. 1. Place the supplied software CD in t he PC CD-ROM. The D ...

  • Extech Instruments 42265 - page 5

    V7.1 1/08 5 Software Operation Main Screen Diagram A: Main Screen Cursor 1 and 2 Control Click on a cursor line to select it. When the r ed cursor line is clicked, it turns bold red. When you click the green cursor, it turns bol d green (colors may vary). The CURSOR STATUS field (lower left) shows the cursor pos itions. As the Arrow keys are used t ...

  • Extech Instruments 42265 - page 6

    V7.1 1/08 6 Zoom and Pan on Graphs To zoom in, press the <Ctrl> key and click the left mouse button over the desired poi nt; release the <Ctrl> key after the mouse button is pr essed. The view resolution increases until the mouse button is released. To z oom out, click the right mouse button. To pan, press the <Ctrl-Shift> keys an ...

  • Extech Instruments 42265 - page 7

    V7.1 1/08 7 Retrieve File Click on RETRIEVE FILE to retrieve a previously saved file. To aid in reading a graph, a grid can be dra wn on the graph. A dialogue box at the bottom left hand corner shows the grid (CONTROL L OCATION Cursor 1 and 2) After retrieving a file containing Humidity reco rds, the labels "Temperature" and "Humidit ...

  • Extech Instruments 42265 - page 8

    V7.1 1/08 8 Com Port Setup Select "Com. Set" . Select the COM port, Baud rate (9600), Data bits (8), Parit y (None) and Stop bits (1). Select OK to accept settings, press Cancel to abort and exit. ...

  • Extech Instruments 42265 - page 9

    V7.1 1/08 9 Datalogger Settings Press LOGGER to access the menu page Sample Rate Setup Number of Data Points Select the desired number of data samples to log: 1000 / 2000 / 4000/ 8000 / 12 000 / 16000. Scroll up or down to located the value and then click OK to save. For example, to select 1,000 samples, the logger will stop logging (and will power ...

  • Extech Instruments 42265 - page 10

    V7.1 1/08 10 Start Mode Setup Datalogger Clock Setting Click OK to set logger to PC system time. Alarm Setting The default High Alarm temperature is 85 C The default Low Alarm temperature is -40 C The default High Alarm for Relative Humidity is 100% The default Low Alarm Relative Humidity is 0% Select the desired High value or Low value by scrollin ...

  • Extech Instruments 42265 - page 11

    V7.1 1/08 11 Unit Setting Temperature can be displayed in " C " or " F " Data Logger ID Setting The datalogger's ID setting allows the user to provide a unique name for each datalogger (up t o 8-digits). Sleep Mode Setting In Sleep Mode the Datalogger turns the display off after Datalogging has been comp leted. Select the S ...

  • Extech Instruments 42265 - page 12

    V7.1 1/08 12 Data Table P ress the DATA TABLE icon to view data GO Process the data using the conditions selected. Channel Selects Temperature or Humidity for analysis. Condition Selects if range values are “AND” (both occur) or “OR” (either occurs). Error Selects and counts all the error codes in the file. Usage Indicates the number of rec ...

  • Extech Instruments 42265 - page 13

    V7.1 1/08 13 Statistics Press the STATISTICS icon to view histograms of data based on the " Whole Range " or the " Cursor Range ". See (Diagram I) Whole Range - All of the logged readings . Cursor Range - Only the readings between the two cursors . 1. Click and drag the knobs’ yellow line (shown in the left side of Diagram I-1 ...

  • Extech Instruments 42265 - page 14

    V7.1 1/08 14 4. Diagram I-2 is another example of setting the cursor range; it has been set to 100 divisions. 5. Diagram J-1 shows that cursor 1 is used for the temperature readings and the lower region shows the Relative Humidity records. In Diagram J-2 the divisions are set to 130. 6. Diagram I is a Temperature example using Di agrams I-1 an d I- ...

  • Extech Instruments 42265 - page 15

    V7.1 1/08 15 Group Files Click GROUP FILES to view the "Multi-Logger Monito r" designed to view and compare data files. Diagram M shows the screen as it appears before the icon is clicked. Select the color of the curve by clicking the color block. Print the data by clicking the printer icon at the right-most top corner. Note: To retrieve ...

  • Extech Instruments 42265 - page 16

    V7.1 1/08 16 Click to select the file that will be used for comparison, click the color icon box to select the desired color. Each file is repres ented by a capital letter (A through H ) with the file name following the letter. When comparing data files: Diagram M shows the main screen before a file is retrieved. Diagram N shows the main screen wit ...

  • Extech Instruments 42265 - page 17

    V7.1 1/08 17 Previous Setting Previous setting records are listed in this column for reference. To download data from another datalogger without exiting the current screen: a) Click “PREVIOUS SETTING" to replace the last logger data with a new one. b) Close and reopen the program. Note: Clicking on "Retrieve File" will not download ...

  • Extech Instruments 42265 - page 18

    V7.1 1/08 18 Message The message area is blank if no file has been re trieved. After a file is retrieved the message will display as follows: "Retrieve file completed" Download Commands Start - To begin downloading data (See belo w diagram) Stop - To manually stop downloading data. Exit - To exit the Download utility. Display Control Offs ...

  • Extech Instruments 42265 - page 19

    V7.1 1/08 19 Example 2: Set the Offset to "4000" (refer to Diagram S and S1 ). The screen shows 4000 as the starting point for the 8,000 record total. Display Control (for X-Axis records) Range - Allows the user to configure the data range. ...

  • Extech Instruments 42265 - page 20

    V7.1 1/08 20 Example 1: Set the Range by clicking & dragging the red indicator ( Diagram T) to "1K" (Diagram T-1 shows data records from 0001 to 1000) . Example 2: Set the Range to "4K" as in Diagram U. Diagram U-1 show s the data records from 0001 to 4001. ...

  • Extech Instruments 42265 - page 21

    V7.1 1/08 21 Battery Replacement Follow these steps to remove and replace the battery: 1. Remove the four (4) rear Phillips-head screws 2. Ensure that the o-ring remains in its groove. 3. Remove the expired battery. 4. Insert a new battery (CR2) ens uring correct polarity. 5. Fasten the four rear screws. Specifications Display 3-digit multi-functio ...

  • Extech Instruments 42265 - page 22

    V7.1 1/08 22  Support line (781) 890-7440 Technical support: Extension 200; E-mail: support@extech.co m Repair & Returns: Extension 210; E-mail: repair@extech.com Product specificatio ns subject to chan ge without notic e For the latest version of this User’s Guide, Software updates, and other up-to-the-minute product in formation, visit o ...

Produzent Extech Instruments Kategorie Weather Radio

Dokumente, die wir vom Produzenten des Geräts Extech Instruments 42265 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Extech Instruments
- Bedienungsanleitungen 42265
- Produktkarten Extech Instruments
- Informationsbroschüren
- oder Energieetiketten Extech Instruments 42265
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Extech Instruments 42265.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Extech Instruments 42265, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Extech Instruments 42265. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Extech Instruments 42265 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Extech Instruments 42265, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Extech Instruments 42265 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Extech Instruments 42265 verständlich ist.

Eine gänzliche Bedienungsanleitung von Extech Instruments sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Extech Instruments 42265 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Extech Instruments 42265 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Extech Instruments 42265, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Extech Instruments 42265 - die uns die ersten Schritte während der Nutzung von Extech Instruments 42265 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Extech Instruments 42265 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Extech Instruments 42265 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Extech Instruments 42265?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Extech Instruments 42265 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Extech Instruments 42265 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)