    Visit our website at www.MillerW elds.com Pro cesses Descrip tio n MIG (GMAW) W elding Flux Cored (FCA W ) W elding Wire Feeder OM -186 895G June 1999 I-22A & I-24A ...

  • Miller Electric I-22A & I-24A - page 2

    Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual catalog sheets. T o locate your nearest distributor call 1-800-4-A-Miller . Thank you and congratulations on choosing Miller ...

  • Miller Electric I-22A & I-24A - page 3

    T ABLE OF CONTENTS SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2. Arc W elding Hazards 1 . . . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric I-22A & I-24A - page 4

    dec_con1 1/96 Declaration of Conformity for European Community (CE) Products This information is provided for units with CE certification (see rating label on unit). NOTE Manufacturer ’ s Name: Miller Electric Mfg. Co. Manufacturer ’ s Address: 1635 W . Spencer Street Appleton, WI 54914 USA Declares that the product: I-22A And I-24A conforms to ...

  • Miller Electric I-22A & I-24A - page 5

    OM-186 895 Page 1 SECTION 1 − SAFETY PRECAUTIONS - READ BEFORE USING som _nd_5/97 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown i n the adjoining symbols. Y Marks a special safety message. . Means “Note”; not safety related. This group of symbols means W arning! Wa ...

  • Miller Electric I-22A & I-24A - page 6

    OM-186 895 Page 2 Arc rays from the weld ing process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly off from the weld. ARC RA YS can burn eyes and skin. D Wear a welding helmet fitted with a proper shade of filter to protect your face and eyes when welding or watching (see ANSI Z49.1 an ...

  • Miller Electric I-22A & I-24A - page 7

    OM-186 895 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring − be sure power supply system is properly sized, rated, and protected to handle this unit. ...

  • Miller Electric I-22A & I-24A - page 8

    OM-186 895 Page 4 1-5. EMF Information Considerations About W elding And The Effects Of Low Frequency Electric And Magnetic Fields W elding current, as it flows through welding cables, will cause electro- magnetic fields. There has been and still is some concern about such fields. However , after examining more than 500 studies spanning 17 years of ...

  • Miller Electric I-22A & I-24A - page 9

    OM-186 895 Page 5 SECTION 1 − CONSIGNES DE SECURITE − LIRE A V ANT UTILISA TION som _nd_fre 5/97 1-1. Signification des symboles Signifie Mise en garde ! Soyez vigilant ! Cette procédure présente des risques de danger ! Ceux-ci sont identifiés par des symboles adjacents aux directives. Y Identifie un message de sécurité particulier . . Sig ...

  • Miller Electric I-22A & I-24A - page 10

    OM-186 895 Page 6 Le rayonnement de l’arc du procédé de soudage génère des rayons visibles et invisibles intenses (ultraviolets et infrarouges) susceptibles de provoquer des brûlures dans les yeux et sur la peau. Des étincelles sont projetées pendant le soudage. LES R A YONS DE L ’ARC peuvent pro- voquer des brûlures dans les yeux et su ...

  • Miller Electric I-22A & I-24A - page 11

    OM-186 895 Page 7 1-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance Risque D’INCENDIE OU D’EXPLOSION. D Ne pas placer l’appareil sur , au-dessus ou à proxi- mité de surfaces infllammables. D Ne pas installer l’appareil à proximité de produits inflammables D Ne pas surcharger l’install ...

  • Miller Electric I-22A & I-24A - page 12

    OM-186 895 Page 8 1-4. Principales normes de sécurité Safety in W elding and Cutting, norme ANSI Z49.1, de l’American Wel - ding Society , 550 N.W . Lejeune Rd, Miami FL 33126 Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent of Documents, U.S. Government Printing Of fice, Washington, D.C. 20402. Recommended Safe Practice for the ...

  • Miller Electric I-22A & I-24A - page 13

    OM-186 895 Page 9 SECTION 2 − DEFINITIONS 1 1.1 1.2 1.3 3 3.1 3.2 3.3 4 4.1 + 2 2.1 2.2 + + 56 + 2.3 S-178 936 A. Warning! W atch Out! There are possible hazards as shown by the symbols. B. Drive rolls can injure fingers. C. W elding wire and drive parts are at welding voltage during operation − keep hands and metal objects clear . 1 Electric s ...

  • Miller Electric I-22A & I-24A - page 14

    OM-186 895 Page 10 2-2. Rating Label For CE Products 178 794-A S/N: 24 7.0 Hz 50/60 IP 23 V 100 A 500 X 100 % V U 1 = A I 1 = 1 U 2 = I 2 = 2-3. Symbols And Definitions Some symbols are found only on CE products. NOTE On Of f Input Output A Amperes V V olts Alternating Current X Duty Cycle IP Degree Of Protection Hz Hertz Circuit Breaker Wire Feed ...

  • Miller Electric I-22A & I-24A - page 15

    OM-186 895 Page 1 1 SECTION 3 − INST ALLA TION 3-1. Specifications T ype of Input Power W elding Power Source T ype Wire Feed Speed Range Wire Diameter Range W elding Circuit Rating IP Rating Overall Dimensions W eight 24 V olts AC Single Phase 7 Amperes 50/60 Hz Constant V oltage (CV) DC With 14-Pin And Contactor Control 1.9 T o 19 mpm (75 to 75 ...

  • Miller Electric I-22A & I-24A - page 16

    OM-186 895 Page 12 3-3. Gun Recommendation T able Process Gun GMA W − Hard or Corded Wires M25 Or M40 FCA W − Self-Shielding Wires GA-40GL 1 CV Welding Power Source With 24 V AC Power 2 CV Welding Power Source Without 24 V AC Power 3 1 15 V olts AC /24 V olts AC Power Adapter 4 14-Pin Control Cord 5 Weld Cable (Required) 6 W ork 3-4. Equipment ...

  • Miller Electric I-22A & I-24A - page 17

    OM-186 895 Page 13 3-6. 14-Pin Receptacle Information Pin* Pin Information A 24 volts ac with respect to pin G. A J K B Contact closure to A completes 24 volts ac contactor control circuit. A J B K I G Circuit common for 24 volts AC circuit. B C L N H C +10 volts dc output to remote control with respect to pin D. D M G E F D Remote control circuit ...

  • Miller Electric I-22A & I-24A - page 18

    OM-186 895 Page 14 3-8. Optional Meter Circuit Board Settings 801 925-C / Ref. 186 266 T ools Needed: 1/4 in 1 Meter Circuit Board 2 DIP Switch S2 3 Potentiometer R18 4 Receptacle RC16 Wiring harness with free-hanging plug PLG42 connects to RC16. For voltage feedback from voltage sensing lead, connect plug PLG43 from unit wiring harness to PLG42. F ...

  • Miller Electric I-22A & I-24A - page 19

    OM-186 895 Page 15 3-9. Motor Start/Burnback Control 801 925-C / 192 653 T o change wire feed starting speed proceed as follows: T urn Off unit and welding power source. Remove wrapper . 1 Motor Board PC1 2 Motor Start Control Potentiometer R73 Remove protective white rubber cap before making adjustment. Adjust potentiometer R73 using a small nonco ...

  • Miller Electric I-22A & I-24A - page 20

    OM-186 895 Page 16 3-10. Installing Wire Guide And Drive Roll 801 923-C Install and secure inlet wire guide on either assembly , and intermediate wire guide on 4 drive roll assembly only . Install drive rolls and turn drive roll nut one click. During maintenance intervals, remove drive rolls, and clean grooves using a wire brush. Check groove of dr ...

  • Miller Electric I-22A & I-24A - page 21

    OM-186 895 Page 17 3-1 1. Installing And Threading W elding Wire T ools Needed: 1 Retaining Ring 2 Hub T ension Adjustment Nut If necessary , move hub on support for use of different size wire spool. Remove retaining ring, and install spool so hub pin fits spool hole. Reinstall retaining ring. Adjust tension nut so wire is taut when wire feed stops ...

  • Miller Electric I-22A & I-24A - page 22

    OM-186 895 Page 18 SECTION 4 − OPERA TION 4-1. Front Panel Controls 1 Optional V oltage/Wire Speed Meter 2 Optional V oltage/Wire Speed Switch Use to choose volts or wire feed speed display . 3 Optional Remote V oltage Control Use to set welding power source voltage a t the wire feeder . Numbers are for reference only . 4 Wire Speed Control 5 Jog ...

  • Miller Electric I-22A & I-24A - page 23

    OM-186 895 Page 19 4-2. Optional Side Panel Controls Ref. 801 923-C / Ref. 186 589 1 Preflow Control Control sets time gas flows before welding wire is energized. Time range is 0 to 5 seconds. 2 Postflow Control Control sets time gas flows after completion of burnback. T ime range is 0 to 5 seconds. 3 Spot Time Control Factory set for 0.25 to 5 sec ...

  • Miller Electric I-22A & I-24A - page 24

    OM-186 895 Page 20 5-2. Overload Protection Y T urn Off wire feeder and welding power source. Stop engine on welding generator . 1 Circuit Breaker CB1 CB 1 protects wire feeder from over- load. Correct problem and manually reset breaker . 801 921-C 1 5-3. T roubleshooting T rouble Remedy Wire does not feed, unit completely inop- erative. T urn Powe ...

  • Miller Electric I-22A & I-24A - page 25

    OM-186 895 Page 21 SECTION 6 − ELECTRICAL DIAGRAM 186 738-B Figure 6-1. Circuit Diagram For Wire Feeder With Optional Equipment ...

  • Miller Electric I-22A & I-24A - page 26

    OM-186 895 Page 22 SECTION 7 − P ARTS LIST Figure 7-1. Main Assembly . Hardware is common and not available unless listed. 801 990-C Figure 7-2 & Figure 7-3 − 1 2 3 4 5 6 7 8 9 10 11 12 13 12 11 14 15 16 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 23 44 45 46 47 48 49 50 51 52 53 17 18 ...

  • Miller Electric I-22A & I-24A - page 27

    OM-186 895 Page 23 Description Part No. Dia. Mkgs. Item No. Figure 7-1. Main Assembly Quantity 1 089 899 LA TCH 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 +186 674 WRAPPER 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Miller Electric I-22A & I-24A - page 28

    OM-186 895 Page 24 Description Part No. Dia. Mkgs. Item No. Figure 7-1. Main Assembly (Continued) Quantity 39 192 955 CASE ASSEMBL Y 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 LED1 ♦ 179 203 LED, 5100 2.0V 20MA green 1 . . . . . . . . . . . . . . . . . . ...

  • Miller Electric I-22A & I-24A - page 29

    OM-186 895 Page 25 Description Part No. Dia. Mkgs. Item No. Figure 7-2. Drive Assembly , Wire (2 Drive Roll) (Fig 7-1 Item 48) Quantity 1 602 009 SCREW , .250-20 x 1.250 soc hd hex gr 8 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 172 075 CARRIER, drive roll w/component 24 pitch 1 . . . . . . . . . ...

  • Miller Electric I-22A & I-24A - page 30

    OM-186 895 Page 26 Description Part No. Dia. Mkgs. Item No. Figure 7-3. Drive Assembly , Wire(4 Drive Roll) (Fig 7-1 Item 48) Quantity 1 602 009 SCREW , .250-20 x 1.250 soc hd hex gr 8 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 172 075 CARRIER, drive roll w/component 24 pitch 4 . . . . . . . . . ...

  • Miller Electric I-22A & I-24A - page 31

    OM-186 895 Page 27 T able 7-1. Drive Roll And Wire Guide Kits (2 Drive Roll) Base selection of drive rolls upon the following recommended usages: 1. V -Grooved rolls for hard wire. 2. U-Grooved rolls for soft and soft shelled cored wires. 3. U-Cogged rolls for extremely soft shelled wires (usually hard surfacing types). 4. V -Knurled rolls for hard ...

  • Miller Electric I-22A & I-24A - page 32

    OM-186 895 Page 28 T able 7-2. Drive Roll & Wire Guide Kits (4 Drive Roll) Base selection of drive rolls upon the following recommended usages: 1. V -Grooved rolls for hard wire. 2. U-Grooved rolls for soft and soft shelled cored wires. 3. U-Cogged rolls for extremely soft shelled wires (usually hard surfacing types). 4. V -Knurled rolls for ha ...

  • Miller Electric I-22A & I-24A - page 33

    OM-186 895 Page 29 Notes ...

  • Miller Electric I-22A & I-24A - page 34

    OM-186 895 Page 30 Notes ...

  • Miller Electric I-22A & I-24A - page 35

    Warranty Questions? Call 1-800-4-A -MI LLER for your loc al Miller d istr ibutor. miller_warr 1/99 Y o ur distributor also gives you ... Service Y ou always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor . The exper ...

  • Miller Electric I-22A & I-24A - page 36

    PRINTED IN USA © 1999 Miller Electric Mfg. Co. 9/98 Miller Elect ric Mfg. Co. An Illinois T ool W orks Compan y 1635 West S pencer Street Applet on, WI 54914 USA International He adquarters − USA USA Phone: 9 20-735-4505 Auto-A tt ended USA & C anada F AX : 920-735-4134 Int ernati onal F A X: 9 20-735-4125 European Headqua rters − United K ...

Produzent Miller Electric Kategorie Welder

Dokumente, die wir vom Produzenten des Geräts Miller Electric I-22A & I-24A erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Miller Electric
- Bedienungsanleitungen I-22A & I-24A
- Produktkarten Miller Electric
- Informationsbroschüren
- oder Energieetiketten Miller Electric I-22A & I-24A
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Miller Electric I-22A & I-24A.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Miller Electric I-22A & I-24A, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Miller Electric I-22A & I-24A. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Miller Electric I-22A & I-24A ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Miller Electric I-22A & I-24A, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Miller Electric I-22A & I-24A hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Miller Electric I-22A & I-24A verständlich ist.

Eine gänzliche Bedienungsanleitung von Miller Electric sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Miller Electric I-22A & I-24A bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Miller Electric I-22A & I-24A befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Miller Electric I-22A & I-24A, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Miller Electric I-22A & I-24A - die uns die ersten Schritte während der Nutzung von Miller Electric I-22A & I-24A erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Miller Electric I-22A & I-24A hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Miller Electric I-22A & I-24A im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Miller Electric I-22A & I-24A?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Miller Electric I-22A & I-24A nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Miller Electric I-22A & I-24A hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)