    1 PRINTED IN THE U.S.A. 0905 www.sears.com P ART NO. 185249-000 Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A C3 T echnology ® Gas Water Heaters meet the new ANSI Z21.10.1 standard that deals with the accidental or unintended ignition of flammable vapors, such as those emitted by gasoline. Owner ’ s Manual FOR POT ABLE W A TER HEA TING ...

  • Sears 153.332060 - page 2

    2 SAFE INST ALLA TION, USE AND SERVICE Y our safety and the safety of others is extremely important in the inst allation, use and servicing of this water heater . Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety ...

  • Sears 153.332060 - page 3

    3 SAFETY PRECAUTIONS ...

  • Sears 153.332060 - page 4

    4 SAFE INST ALLA TION, USE AND SER VICE .................................................................................................................................... 2 SAFETY PRECAUTIONS ............................................................................................................................................................ ...

  • Sears 153.332060 - page 5

    5 T AN K RECOVERY MINIMUM CAP ACITY INPUT RATE GALS. VENT PIPE DIAMETER DIMENSIONS IN MODEL IN G ALS. TYPE OF RA TE PER HOUR INCHES INCHES INCHES (mm) HEIGHT NUMBER ( L TRS) GA S (Btu/hr) @ 90°F RISE (mm) (mm) T O JACKET TOP 153.332040 40 (151) NA TURAL 40,000 44 2 (51) 18 1/2 (470) 55 (1,397) 153.332050 50 (189) NA TURAL 40,000 44 2 (51) 20 (508) ...

  • Sears 153.332060 - page 6

    6 Materials Needed T o simplify the installation Sears has available the installation p arts shown below . Y ou may or may not need all of these materials, depending on your type of installation. W A TER HEA TER INST ALLA TION KIT WITH FLEXIBLE CONNECTORS FOR 3/4” (19.05 mm) OR 1/2” (12.7 mm) THREADED OR COPPER PLUMBING AND FLEXIBLE GAS CONNECT ...

  • Sears 153.332060 - page 7

    7 TYPICAL INST ALLA TION GET T O KNOW YOUR W A TER HEA TER - GAS MODELS A V ent Pipe–Exhaust B V ent T erminal C V ent Adapter-Rubber Boot D Blower Assembly E Cold Water Inlet F Inlet Water Shut-off V alve G Union H Inlet Dip T ube J Anode** FIGURE 1. K Hot Water Outlet L Outlet Receptacle (1 15 V AC) M T emperature-Pressure Relief V alve N Flue ...

  • Sears 153.332060 - page 8

    8 1. Turn “OFF” the gas supply to the water heater . If the main gas line Shut-off valve serving all gas appliances is used, also shut “OFF” the gas at each appliance. Leave all gas appliances shut “OFF” until the water heater installation is completed, see Figures 2 and 3. 2. Turn “OFF” the water supply to the water heater at the w ...

  • Sears 153.332060 - page 9

    9 FACTS TO CONSIDER ABOUT THE LOCA TION Carefully choose an indoor location for the new water heater , because the placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance. This water heater is not for use in manufactured (mobile) homes or outdoor installation. Whet ...

  • Sears 153.332060 - page 10

    10 and 12" (30.5 cm) from the top. (S tandard clearance.) If clearances stated on the heater differ from standard clearances, install water heater according to clearances stated on the heater . Adequate clearance for servicing this appliance should be considered before installation, such as changing the anodes, etc. A minimum clearance of 5&qu ...

  • Sears 153.332060 - page 11

    11 Chemical vapor corrosion of the flue, blower assembly and vent system may occur if air for combustion contains certain chemical vapors. S pray can propellants, cleaning solvents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach and process chemicals are typical compounds which are ...

  • Sears 153.332060 - page 12

    12 T oxic chemicals, such as those used for boiler treatment shall not be introduced into this system. When the system requires water at temperatures higher than required for domestic water purposes, a tempering valve must be installed. Please refer to Figure 15 for suggested piping arrangement. W ater supply systems may , because of such events as ...

  • Sears 153.332060 - page 13

    13 INST ALLA TION COMPLETED USING INST ALLA TION KIT FIGURE 16. T & P V alve and Pipe Insulation (if supplied) Remove insulation for T & P valve and pipe connections from carton. FIGURE 17. Fit pipe insulation over the incoming cold water line and the hot water line. Make sure that the insulation is against the top cover of the heater . Fit ...

  • Sears 153.332060 - page 14

    14 The Discharge Pipe: • Shall not be smaller in size than the outlet pipe size of the valve, or have any reducing couplings or other restrictions. • Shall not be plugged or blocked. • Shall be of material listed for hot water distribution. • Shall be installed so as to allow complete drainage of both the temperature-pressure relief valve, ...

  • Sears 153.332060 - page 15

    15 The appliance and its gas connection must be leak tested before placing the appliance in operation. The appliance and its individual Shut-off valve shall be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 pound per square inch (3.5 kPa). It shall be isolated from the ga ...

  • Sears 153.332060 - page 16

    16 4. Make sure that the plastic tubing is still attached from the air pressure switch to the port on the blower housing. Make sure the plastic tubing is not folded anywhere between the pressure switch and the blower housing. 5 . Make sure the ON/OFF switch is in the OFF position and that the outer harness is connected from the blower control box t ...

  • Sears 153.332060 - page 17

    17 VENT CONNECTIONS TO BLOWER ASSEMBL Y Figure 21 shows the optimal placement of the 2" to 3" or 3" to 4" reducer; however , the vent can be reduced at any point in the vent system as long as the maximum vent length is not exceeded. FIGURE 21. VENTING AND INST ALLA TION Plan the layout of the vent system from the vent terminatio ...

  • Sears 153.332060 - page 18

    18 VENTING The vent system must terminate so that proper clearances are maintained as cited in local codes or the current edition of the National Fuel Gas Code, ANSI Z223.1/NFP A 54, 7.3.4e and 7.8a,b, as follows: 1 . The exit terminals of a mechanical vent system shall be not less than 7 feet (2.13 m) above grade when located adjacent to public wa ...

  • Sears 153.332060 - page 19

    19 FIGURE 23. This unit can vent through 2", 3" or 4" nonmetallic pipe and fittings. The vent pipe installation can be started from either the blower discharge or the termination wall. Keep in mind the total vent system (pipe and elbows) when installing the vent system, see VENTING AND INST ALLA TION AND MAXIMUM VENT LENGTHS, page 17 ...

  • Sears 153.332060 - page 20

    20 VENT PIPE PREP ARA TION 1. INITIAL PREP ARA TION A. Make sure the solvent cement you are planning to use is designed for the specific application you are attempting. B . Know the physical and chemical characteristics and limitations of the PVC and CPVC piping materials that you are about to use. C . Know the reputation of your manufacturer and t ...

  • Sears 153.332060 - page 21

    21 B . Deburring Use a knife, plastic pipe deburring tool, or file to remove burrs from the end of small diameter pipe. Be sure to remove all burrs from around the inside as well as the outside of the pipe. A slight chamfer (bevel) of about 10°- 15° should be added to the end to permit easier insertion of the pipe into the end of the fitting. Fai ...

  • Sears 153.332060 - page 22

    22 FOR YOUR SAFETY READ BEFORE OPERA TING W ARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner . Do NOT try to light the burner by hand. ...

  • Sears 153.332060 - page 23

    23 TEMPERA TURE REGULA TION Due to the nature of the typical gas water heater , the water temperature in certain situations may vary up to 30°F (16.7°C) higher or lower at the point of use such as, bathtubs, showers, sink, etc. Any water heater’s intended purpose is to heat water. Hot water is needed for cleansing, cleaning, and sanitizing (bod ...

  • Sears 153.332060 - page 24

    24 FOR YOUR INFORMA TION ST ART UP CONDITIONS CONDENSA TE Whenever the water heater is filled with cold water , some condensate will form while the burner is on. A water heater may appear to be leaking when in fact the water is condensate. This usually happens when: a . A new water heater is filled with cold water for the first time. b . Burning ga ...

  • Sears 153.332060 - page 25

    25 STRANGE SOUNDS Possible noises due to expansion and contraction of some metal parts during periods of heat-up and cool-down do not necessarily represent harmful or dangerous conditions. Condensation causes sizzling and popping within the burner area during heating and cooling periods and should be considered normal. See “Condensate” in this ...

  • Sears 153.332060 - page 26

    26 At least once a year a visual inspection should be made of the main burner and the hot surface igniter assembly for proper flame characteristics and ignition sequences. This can be done by removing the Outer Door and viewing the main burner operation through the Viewport on the Inner Door , see Figure 1. The main burner should provide complete c ...

  • Sears 153.332060 - page 27

    27 FIGURE 30. When checking the temperature-pressure relief valve operation, make sure that (1) no one is in front of or around the outlet of the temperature- pressure relief valve discharge line, and (2) that the water discharge will not cause any property damage, as the water may be extremely hot, see Figure 30. If after manually operating the va ...

  • Sears 153.332060 - page 28

    28 LEAKAGE CHECKPOINTS Read this manual first. Then before checking the water heater make sure the gas supply has been turned “OFF”, and never turn the gas “ON” before the tank is completely full of water . Never use this water heater unless it is completely filled with water . T o prevent damage to the tank, the tank must be filled with wa ...

  • Sears 153.332060 - page 29

    29 TROUBLESHOOTING GUIDELINES TROUBLESHOOTING GUIDELINES These guidelines should be used by a qualified service agent. Call Sears Service at 1-800-4-MY -HOME ® (1-800-469-4663) for assistance. Inform the associate that this is a “Flammable V apor Ignition Resist ant” Product. PROBLEM SOLUTION An open earth ground circuit to the 1. Check that t ...

  • Sears 153.332060 - page 30

    30 These guidelines should be utilized by a qualified service agent. When calling for service notify the service agent that this is a “Flammable V apor Ignition Resistant” Product. TROUBLESHOOTING GUIDELINES ...

  • Sears 153.332060 - page 31

    31 REP AIR P ARTS LIST Now that you have purchased your gas water heater , should a need ever exist for repair parts or service, simply contact any Sears Service Center or call 1-800-4-MY -HOME® (1-800-469-4663). Be sure to provide all pertinent facts when you call or visit. The model number of your Gas Water Heater will be found on the rating pla ...

  • Sears 153.332060 - page 32

    32 6 YEAR LIMITED W ARRANTY ON WA TER HEA TER Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. MASTER PROTECTION AGREEMENTS Congratulations on making a smart purchase. Y our new Kenmore ® product is designed and manufactured for years of dependable operation. But like all products, it may require preventive maintenance or repair from time ...

Produzent Sears Kategorie Water Heater

Dokumente, die wir vom Produzenten des Geräts Sears 153.332060 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Sears
- Bedienungsanleitungen 153.332060
- Produktkarten Sears
- Informationsbroschüren
- oder Energieetiketten Sears 153.332060
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Sears 153.332060.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Sears 153.332060, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Sears 153.332060. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Sears 153.332060 ansehen.

Die komplette Bedienungsanleitung des Geräts Sears 153.332060, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Sears 153.332060 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Sears 153.332060 verständlich ist.

Eine gänzliche Bedienungsanleitung von Sears sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Sears 153.332060 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Sears 153.332060 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Sears 153.332060, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Sears 153.332060 - die uns die ersten Schritte während der Nutzung von Sears 153.332060 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Sears 153.332060 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Sears 153.332060 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Sears 153.332060?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Sears 153.332060 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Sears 153.332060 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)