    332018-BTG-D-0208 FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE SPLIT -SYSTEM AIR CONDITIONERS 14 SEER – R-22 MODELS: H*BE-F018 THRU 060 (1.5 THRU 5 NOMINAL T ONS) Due to continuo us product impr ovement, specifi cations are subjec t to ch an ge without notice. Visit us on the web at www .york.com Additional rating in formati ...

  • York H*BE-F018 - page 2

    332018-BTG-D-0208 2 Unitary Products Group All dimensions are in inches. The y are subject to change without notice. Ce rtif ied dimensio ns will be p rovided upon request. Physical and Electr ical Dat a MODEL HABE-F018S HDBE-F024S HCBE-F030S HABE-F036S HBBE-F042S HBBE-F048S HCBE-F060S Unit Supply V oltage 208-230V , 1 φ, 60Hz Normal V oltage Rang ...

  • York H*BE-F018 - page 3

    332018-BTG-D-0208 Unitary Products Group 3 Additional R-22 Charge / Orifice Size for V arious Ma tched Systems - 1 Phase Outdoor Unit HABE-F018S HDBE-F024S HCBE-F030S HABE-F036S HBBE-F042S HBBE-F048S HCBE-F060S Required TXV 1 1 TVM2A1 1 TVM2A1 1 TVM2A1 1 TVM702 1 TVM703 1 TVM703 1 TVM2C1 Factory Charge, lbs-oz 5 - 9 6 - 0 8 - 2 9 - 14 14 - 15 15 - ...

  • York H*BE-F018 - page 4

    332018-BTG-D-0208 4 Unitary Products Group PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrige rant for the condenser , the smallest evaporator and 15 feet of interconnecting line tubing. 2. V er if y the TXV and additional charge required for specific eva porator coil in the system using the above table. 3. Additional ...

  • York H*BE-F018 - page 5

    332018-BTG-D-0208 Unitary Products Group 5 Go to www.ari. org/aridirectory for the latest additi onal mat ches. COOLING CAP ACITY - Wi th Air Handler Coils UNIT MODEL AIR HANDLER COIL MODEL 1 COOLING MODEL W RA TED CFM NET MBH SEER EER TOT AL SENS. 1 PH 14 SEER AC WITH MA HABE-F018S MA08B 17 FC/MC24B 600 17 .5 12 .1 14.00 12.00 MA08B 17 FC/MC30B 60 ...

  • York H*BE-F018 - page 6

    332018-BTG-D-0208 6 Unitary Products Group COOLING CAP ACITY - Up flow , Downflow & Horizontal Furnaces and Coils UNIT MODEL FURNACE COIL MODEL COOLING CFM RANGE (MIN.-MAX.) W RA TED CFM NET MBH SEER 1 EER TOT AL SENS. HABE-F018S 450 750 14,17 FC/MC/PC/UC24 600 17.5 12.1 14.00 12.00 14,17 FC/MC/PC/UC30 600 17.5 12.1 14.00 12.00 14 HC30 600 17.3 ...

  • York H*BE-F018 - page 7

    332018-BTG-D-0208 Unitary Products Group 7 COOLING CAP ACITY - W ith V ariable Speed Fur naces UNIT MODEL V ARIABLE SPEED FURNACE MODEL COIL MODEL 1 W COOLING RA TED CFM NET MBH SEER EER T OTAL SENS. 1 PH 14 SEER AC WITH V ARIABLE SPEED FURNACES 2 HABE-F018S (F ,L)L8V*A12 FC/MC/PC24A 14 600 17.9 12.3 15.00 12.00 FL9V*A12 FC/MC/PC24A 14 600 17.8 12. ...

  • York H*BE-F018 - page 8

    332018-BTG-D-0208 8 Unitary Products Group HBBE-F042S (F ,L)L8V*C16 FC/MC/PC48C 21 1420 40.0 28.8 14.00 12 .00 (F ,L)L8V*C20 FC/MC/PC48C 21 1420 40.0 28.8 14.50 12 .00 FL9(C,V)*C16 FC/MC/PC48C 21 1400 39.5 28.4 14 .00 12.00 FL9(C,V)*C20 FC/MC/PC48C 21 1400 39.5 28.4 14 .00 12.00 FL9(C,V)*D20 FC/MC/PC48D 24 1400 39.5 28.4 14 .00 12.00 FL9(C,V)*D20 F ...

  • York H*BE-F018 - page 9

    332018-BTG-D-0208 Unitary Products Group 9 ACCESSORIES Refer to Price Manual for specific model numbers. Compressor Blanket - Designed to further reduce the nor- mal operating sound and is required to meet C anadian sound levels for units of three tons and below . Refer to Price Manual for specific model numbers. Blower Time Delay - A vailable to i ...

  • York H*BE-F018 - page 10

    332018-BTG-D-0208 10 Unitary Products Group Multipliers for determining the perfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperatu re and decre ases by 1060 BTUH per 1000 CFM per degree bel ...

  • York H*BE-F018 - page 11

    332018-BTG-D-0208 Unitary Products Group 11 Multipliers for determining the performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increase s by 1060 BTUH per 100 0 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per degree belo ...

  • York H*BE-F018 - page 12

    332018-BTG-D-0208 12 Unitary Products Group Multipliers for determining the perfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperatu re and decre ases by 1060 BTUH per 1000 CFM per degree bel ...

  • York H*BE-F018 - page 13

    332018-BTG-D-0208 Unitary Products Group 13 Multipliers for determining the performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increase s by 1060 BTUH per 100 0 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per degree belo ...

  • York H*BE-F018 - page 14

    332018-BTG-D-0208 14 Unitary Products Group Multipliers for determining the perfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperatu re and decre ases by 1060 BTUH per 1000 CFM per degree bel ...

  • York H*BE-F018 - page 15

    332018-BTG-D-0208 Unitary Products Group 15 Multipliers for determining the performance with other indoor sections . NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increase s by 1060 BTUH per 100 0 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per degree belo ...

  • York H*BE-F018 - page 16

    Subject to change without notice. Printed in U.S.A. 332018-BTG-D-0208 Copyright © by Unitary Products Group. 2008. All rights reserved. Supersedes: 332018-BTG-C-0108 Unitary 5005 Norman Product Y ork OK Group Drive 73069 Multipliers for determining the perfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those ...

Produzent York Kategorie Air Conditioner

Dokumente, die wir vom Produzenten des Geräts York H*BE-F018 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen York
- Bedienungsanleitungen H*BE-F018
- Produktkarten York
- Informationsbroschüren
- oder Energieetiketten York H*BE-F018
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung York H*BE-F018.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen York H*BE-F018, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen York H*BE-F018. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts York H*BE-F018 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts York H*BE-F018, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von York H*BE-F018 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von York H*BE-F018 verständlich ist.

Eine gänzliche Bedienungsanleitung von York sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von York H*BE-F018 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von York H*BE-F018 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich York H*BE-F018, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts York H*BE-F018 - die uns die ersten Schritte während der Nutzung von York H*BE-F018 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit York H*BE-F018 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von York H*BE-F018 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich York H*BE-F018?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit York H*BE-F018 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit York H*BE-F018 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)