Bedienungsanleitung Renesas H8/3337Y

19 Seiten 0.25 mb
Download

Zur Seite of 19

Summary
  • Renesas H8/3337Y - page 1

    H8/3337Y Series, H8/3334 Series, H8/338 Series, H8/330, H8/350 QFP-80A User System Interface Cable (HS3337ECH61H) for E6000 Emulator User’s Manual HS3337ECH61HE(D) ...

  • Renesas H8/3337Y - page 2

    Cautions 1. Renesas neither warrants nor grants li censes of any rights of Renesas’s or any t hird party’s patent, copyright, t rademark, or other intel lect ual property rights for informat ion contained in this document. Renesas bears no responsibility fo r problem s that may arise with third party’s rights, including int ellectual property ...

  • Renesas H8/3337Y - page 3

    i Preface Thank you for purchasing the E6000 em ulator for the Renesas’s original m icroprocessor H8/300 series. The HS3337ECH61H is a user system interface cable that connects an H8/300 series E6000 emulator (HS3008EPI60H; hereinafter referred to as the emul ator) to the IC socket for a QFP-80A package (package code: FP-80A) for the H8/3337Y ser ...

  • Renesas H8/3337Y - page 4

    ii Contents Section 1 Configuration .................................................................................... 1 Section 2 Connection Procedures ...................................................................... 4 2.1 Connecting User System Interf ace Cable to Em ulat or Station ......................................... 4 2.2 Connecti ...

  • Renesas H8/3337Y - page 5

    1 Section 1 Configuration CAUTION Use an IC149-080-017-B5 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-80A package IC socket on the user system. Figure 1 shows the configuration of the HS3337E CH61H user system interface cable for the FP-80A package. ...

  • Renesas H8/3337Y - page 6

    User system IC socket Cable head Screws (M2 x 12 mm) with flat washers Screws (M2 x 8 mm) with flat washers Socket cover (for fastening cable head) To emulator station Cable body Figure 1 HS3337ECH61H User System Interface Cable 2 ...

  • Renesas H8/3337Y - page 7

    3 Table 1 lists the HS3337ECH61H com ponents. Please m ake sure you have all of these components when unpacking. Table 1 HS3337ECH61H Components No. Component Quantity Remarks 1 Cable body 1 Includes flat cable 2 Cable head 1 3 IC socket 1 For the FP-80A package 4 Socket cover 1 For installing an FP-80A-packaged MCU 5 Screws (M2.0 x 12 mm) 4 For fa ...

  • Renesas H8/3337Y - page 8

    Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so w ill damage ...

  • Renesas H8/3337Y - page 9

    2.2 Connecting User System Interface Cable to User System W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so w ill damage the user system and the emulator pro ...

  • Renesas H8/3337Y - page 10

    6 2.2.4 Fastening Cable Head CAUTION 1. Use a Phillips-type screwdriver whose head matches the screw head. 2. The tightening torque must be 0.0784 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a sc ...

  • Renesas H8/3337Y - page 11

    Fasten the user system interface cable head to the IC socket fo r an FP-80A package on the user system wit h the four screws (M2.0 x 12 mm ) provided. Each screw should be tightened a little at a time, alt ernating between screws on opposing corners. Take special care, such as m anually securing the IC socket soldered area, to prevent the soldered ...

  • Renesas H8/3337Y - page 12

    2.2.5 Connecting Cable Body to Cabl e Head Connect the cable body to the cable head. Cable body Cable head Remove jig Push the remove jig Removing User system Figure 4 Fastening Cable Body 8 ...

  • Renesas H8/3337Y - page 13

    2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the dime nsions for the recomm ended mount pad (foot print) for the user system with an IC socket for an FP-80A package (IC149-080-017-B5: manufactured by YAM AICHI ELECTRONICS Co., Ltd.). Note that the dimens ions in figure 5 are so m ewhat different from those of the actual chip& ...

  • Renesas H8/3337Y - page 14

    2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interf ace cable head are shown in figure 6. Unit: mm Tolerance: –0.5 mm Figure 6 Dimensions for User System Interface Cable Head 10 ...

  • Renesas H8/3337Y - page 15

    2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after conn ecting the user system interface cab le head to the user system, are shown in figure 7. Cable head User system Unit: mm Tolerance: –0.5 mm IC socket (IC149-080-017-B5 manufactured by YAMAICHI ELECTRONICS Co. Ltd.) Figure 7 Resulting Dimensio ...

  • Renesas H8/3337Y - page 16

    12 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Phillips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.0784 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw become ...

  • Renesas H8/3337Y - page 17

    MCU Pin 1 mark User system Screws (M2.0 x 8 mm) with flat washers Socket cover IC socket (IC149-080-017-B5 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) Figure 8 Installing MCU to User System 13 ...

  • Renesas H8/3337Y - page 18

    Section 4 Verifying Operation 1. When using the H8/300 series E6000 emulat or (HS3008EPI60H), turn on the emulat or according to the procedures described in th e H8/300 Series E6000 Emulator User's Manual (HS3008EPI60HE). 2. Verify the user system interface cable connec tions by accessing the exte rnal m emory and ports to check the bus states ...

  • Renesas H8/3337Y - page 19

    Section 5 Notice 1. Make sure that pin 1 on the user syst em IC socket is correct ly aligned with pin 1 on t he cable head before inserting the cable head into the user system IC socket. 2. The dimensions of t he recommended m ount pad for the user system IC socket are different from those of the MC U. 3. This user system interface cable is specifi ...

Produzent Renesas Kategorie Computer Hardware

Dokumente, die wir vom Produzenten des Geräts Renesas H8/3337Y erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Renesas
- Bedienungsanleitungen H8/3337Y
- Produktkarten Renesas
- Informationsbroschüren
- oder Energieetiketten Renesas H8/3337Y
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Renesas H8/3337Y.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Renesas H8/3337Y, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Renesas H8/3337Y. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Renesas H8/3337Y ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Renesas H8/3337Y, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Renesas H8/3337Y hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Renesas H8/3337Y verständlich ist.

Eine gänzliche Bedienungsanleitung von Renesas sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Renesas H8/3337Y bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Renesas H8/3337Y befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Renesas H8/3337Y, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Renesas H8/3337Y - die uns die ersten Schritte während der Nutzung von Renesas H8/3337Y erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Renesas H8/3337Y hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Renesas H8/3337Y im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Renesas H8/3337Y?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Renesas H8/3337Y nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Renesas H8/3337Y hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen