Bedienungsanleitung Lincoln Electric POWER WAVE IM845-A

42 Seiten 1.61 mb
Download

Zur Seite of 42

Summary
  • Lincoln Electric POWER WAVE IM845-A - page 1

    PO WER W A VE 355M OPERA TOR’S MANUAL For use with machines Code 11141,11489 IM845-A October, 2007 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part. DO NOT INSTALL, OPERATE OR R ...

  • Lincoln Electric POWER WAVE IM845-A - page 2

    FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. ________________________________________________ ...

  • Lincoln Electric POWER WAVE IM845-A - page 3

    ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4. b. Use suitable clothing made from durable flame-resistant material to protect your ski ...

  • Lincoln Electric POWER WAVE IM845-A - page 4

    iii SAFETY iii FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8 .b . Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturerʼs recommendations. 8.c. Ground the equipment in accordance with the U.S. Natio ...

  • Lincoln Electric POWER WAVE IM845-A - page 5

    iv SAFETY iv Mar. ʻ93 PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A LʼArc 1. Protegez-vous contre la secousse électrique: a. Les c ...

  • Lincoln Electric POWER WAVE IM845-A - page 6

    v v Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay ...

  • Lincoln Electric POWER WAVE IM845-A - page 7

    vi vi T ABLE OF CONTENTS Page Installation .......................................................................................................Section A Technical Specifications ........................................................................................A-1 Safety Precautions........................................................... ...

  • Lincoln Electric POWER WAVE IM845-A - page 8

    A-1 INST ALLA TION POWER WAVE 355M A-1 TECHNICAL SPECIFICA TIONS - POWER W A VE 355M INPUT AC VOL T AGE & DC OUTPUT Product Ordering Input AC Rated DC Output Output Weight Dimensions Name Information Voltage Amps/Volts/Duty Cycle Range with Cord HxWxD (continuous) 200 350A / 34V / 60% 14.8” x 13.3” x POWER K2368-1 2 08 - 2 30/ 27.8”* WAVE ...

  • Lincoln Electric POWER WAVE IM845-A - page 9

    A-2 INST ALLA TION POWER WAVE 355M A-2 SELECT SUIT ABLE LOCA TION The Invertec POWER WAVE 355M will operate in harsh environments. Even so, it is important that sim- ple preventative measures are followed in order to assure long life and reliable operation. • The machine must be located where there is free cir- culation of clean air such that air ...

  • Lincoln Electric POWER WAVE IM845-A - page 10

    Output connections on some Power Waves are made via 1/2-13 threaded output studs located beneath the spring loaded output cover at the bottom of the case front. Most welding applications run with the electrode being positive (+). For those applications, connect the elec- trode cable between the wire feeder and the positive (+) output Twist-Mate ter ...

  • Lincoln Electric POWER WAVE IM845-A - page 11

    A-4 INST ALLA TION POWER WAVE 355M A-4 VOL T AGE SENSING The best arc performance occurs when the Power Waves have accurate data about the arc conditions. Depending upon the process, inductance within the electrode and work lead cables can influence the apparent voltage at the studs of the welder. Voltage sense leads improve the accuracy of the arc ...

  • Lincoln Electric POWER WAVE IM845-A - page 12

    POWER W A VE TO SEMI-AUTOMA TIC POWER FEED WIRE FEEDER INTERCON- NECTIONS The POWER WAVE 355M and semi-automatic Power Feed family communicate via a 5 conductor control cable (K1543). The control cable consists of two power leads, one twisted pair for digital communica- tion, and one lead for voltage sensing. The cables are designed to be connected ...

  • Lincoln Electric POWER WAVE IM845-A - page 13

    A-6 INST ALLA TION A-6 POWER WAVE 355M CONFIGURING THE SYSTEM The power source will “Auto Map” the system eliminat- ing most of the need to set DIP switches to configure the system. If a system can not be “Auto Mapped” then the status light on the power source will blink green fast and the welder output will be disabled. If a system is not ...

  • Lincoln Electric POWER WAVE IM845-A - page 14

    A-7 INST ALLA TION POWER WAVE 355M A-7 In this case the individual feed heads need to be assigned to the dual head control and the POWER WAVE 355M auto mapping disabled and the Equipment Groups set on (See Figure A-8). (See the Feeder documenta- tion for information on setting the feeder DIP switches) System that is NOT "Auto Mappable" PO ...

  • Lincoln Electric POWER WAVE IM845-A - page 15

    A-8 INST ALLA TION POWER WAVE 355M A-8 Connect All Work Sense Leads at the End of the Joint Connect All Welding Work Leads at the Beginning of the Joint T ravel Direction PO WER WA VE 355M PO WER WA VE 355M TWO POWER W A VES FIGURE A.6 CONTROL CABLE SPECIFICA TIONS It is recommended that genuine Lincoln control cables be used at all times. Lincoln ...

  • Lincoln Electric POWER WAVE IM845-A - page 16

    A-9 INST ALLA TION POWER WAVE 355M A-9 MUL TIPLE ARC UNSYNCHRONIZED SENSE LEAD AND WORK LEAD PLACEMENT GUIDELINES ...

  • Lincoln Electric POWER WAVE IM845-A - page 17

    A-10 INST ALLA TION POWER WAVE 355M A-10 I / O RECEPT ACLE SPECIFICA TIONS TABLE A.2 WIRE FEEDER RECEPTACLE PIN LEAD# FUNCTION A 53 Communication Bus L B 54 Communication Bus H C 67A Electrode Voltage Sense D 52 0vdc - E 51 +40vdc + TABLE A.3 VOLTAGE SENSE RECEPTACLE PIN LEAD# FUNCTION 3 21A Work Voltage Sense TABLE A.4 RS232 RECEPTACLE PIN LEAD# F ...

  • Lincoln Electric POWER WAVE IM845-A - page 18

    GENERAL DESCRIPTION The Power Wave 355M semi-automatic power source is designed to be a part of a modular, multi-process welding system. Depending on configuration, it can support constant current, constant voltage, constant power and pulse welding modes. The Power Wave 355M power source is designed to be used with the semi automatic family of Powe ...

  • Lincoln Electric POWER WAVE IM845-A - page 19

    5. Internal POWER CIRCUIT BREAKER: Protects 115 volt AC circuit. 6. LEAD CONNECTOR (SENSE LEAD) 7. DIAGNOSTIC CONNECTOR (RS-232) 8. WIRE FEEDER RECEPTACLE (5-PIN) 9. NEGATIVE TWIST- MATE TERMINAL 10. POSITIVE TWIST- MATE TERMINAL FIGURE B.1 10 4 6 1 3 2 5 7 8 9 CASE FRONT LA YOUT POWER W A VE 355M POWER WAVE 355M – Semi-Automatic Operation Power ...

  • Lincoln Electric POWER WAVE IM845-A - page 20

    WELDING ADJUSTMENTS All adjustments are made on the system component known as the User Interface (Control Box), which con- tains the switches, knobs, and digital displays neces- sary to control both the Power Wave and a Power Feed wire feeder. Typically, the Control Box is sup- plied as part of the wire feeder. It can be mounted directly on the wir ...

  • Lincoln Electric POWER WAVE IM845-A - page 21

    Non Synergic CV: This type of CV mode behaves more like a conven- tional CV power source. Voltage and WFS are inde- pendent adjustments. Therefore to maintain the arc characteristics, the operator must adjust the voltage to compensate for any changes made to the WFS. All CV Modes: Arc Control, often referred to as wave control, adjusts the inductan ...

  • Lincoln Electric POWER WAVE IM845-A - page 22

    PULSE-ON-PULSE™ (GMA W -PP) Pulse on Pulse™ is a Lincoln process specifically designed for use in welding relatively thin, less than 1/4"(6.4mm) thick aluminum (See Table B.3). It gives weld beads with very consistent uniform ripple. In Pulse on Pulse modes, two distinct pulse types are used, instead of the single pulse type normally used ...

  • Lincoln Electric POWER WAVE IM845-A - page 23

    B-6 OPERA TION B-6 POWER WAVE 355M BENEFITS OF PULSE ON PULSE FROM LINCOLN ELECTRIC • Excellent appearance of the weld bead • Improved cleaning action • Reduced porosity Table B.2 shows WFS and Trim settings for common aluminum types and wire sizes when welding with Pulse-on-Pulse. The welds made to obtain the values in the table were fillet ...

  • Lincoln Electric POWER WAVE IM845-A - page 24

    B-7 OPERA TION B-7 POWER WAVE 355M POWER MODE™ The Power Mode™ process was developed by Lincoln to maintain a stable and smooth arc at low procedure settings which are needed to weld thin metal without pop-outs or burning-through. For alu- minum welding, it provides excellent control and the ability to maintain constant arc length. This results ...

  • Lincoln Electric POWER WAVE IM845-A - page 25

    C-1 ACCESSORIES C-1 OPTIONAL EQUIPMENT F ACT OR Y INST ALLED None Available. FIELD INST ALLED K940-Work Voltage Sense Lead Kit K1764-1-Undercarriage* K1838-1-Valet Style Undercarriage K1796-Coaxial Welding Cable- (Requires Adapter K2176-1) K2176-1 Twist-mate to Lug Adapters * Dual Cylinder Kit for K1764-1 is K1702-1 Welding Cable Connectors: K852-7 ...

  • Lincoln Electric POWER WAVE IM845-A - page 26

    D-1 MAINTENANCE D-1 POWER WAVE 355M SAFETY PRECAUTIONS CAP ACITOR DISCHARGE PROCEDURE 1. Obtain a power resistor (25 ohms, 25 watts). 2. Hold resistor body with electrically insulated glove. DO NOT TOUCH TERMINALS. Connect the resis- tor terminals across the two studs in the position shown. Hold in each position for 1 second. Repeat for all four ca ...

  • Lincoln Electric POWER WAVE IM845-A - page 27

    E-1 TROUBLESHOOTING E-1 POWER WAVE 355M If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION This Troubleshooting Guide is provided to help you locate and repair ...

  • Lincoln Electric POWER WAVE IM845-A - page 28

    E-2 TROUBLESHOOTING E-2 POWER WAVE 355M USING THE ST A TUS LED TO TROUBLESHOOT SYSTEM PROBLEMS The Power Wave / Power Feed are best diagnosed as a system. Each component (power source, user inter- face, and feedhead) has a status light, and when a problem occurs it is important to note the condition of each. In addition, errors displayed on the use ...

  • Lincoln Electric POWER WAVE IM845-A - page 29

    E-3 TROUBLESHOOTING E-3 POWER WAVE 355M Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION ERROR C ...

  • Lincoln Electric POWER WAVE IM845-A - page 30

    E-4 TROUBLESHOOTING E-4 POWER WAVE 355M Observe all Safety Guidelines detailed throughout this manual TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact your local authorized Lincoln Electri ...

  • Lincoln Electric POWER WAVE IM845-A - page 31

    E-5 TROUBLESHOOTING E-5 POWER WAVE 355M Observe all Safety Guidelines detailed throughout this manual TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact your local authorized Lincoln Electri ...

  • Lincoln Electric POWER WAVE IM845-A - page 32

    E-6 TROUBLESHOOTING E-6 POWER WAVE 355M Observe all Safety Guidelines detailed throughout this manual TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, con- tact your local authorized Lincoln Electri ...

  • Lincoln Electric POWER WAVE IM845-A - page 33

    E-7 TROUBLESHOOTING E-7 POWER WAVE 355M Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBLEM ...

  • Lincoln Electric POWER WAVE IM845-A - page 34

    F-1 WIRING DIAGRAMS F-1 POWER WAVE 355M NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment c ...

  • Lincoln Electric POWER WAVE IM845-A - page 35

    F-2 DIAGRAMS F-2 POWER WAVE 355M NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement. Give the equipment code num ...

  • Lincoln Electric POWER WAVE IM845-A - page 36

    F-3 CONNECTION DIAGRAM F-3 POWER WAVE 355M Connection Diagram Semi-automatic "Simple System" (Electrode Positive, CV/Pulse Configuration shown) POWER WAVE WIRE FEEDER CONTROL CABLE K1543 TO WORK ...

  • Lincoln Electric POWER WAVE IM845-A - page 37

    F-4 DIMENSION PRINT F-4 POWER WAVE 355M 1 4.7 9 1 2.4 4 3.44 21.60 27.82 5.50 10.0 0 MOUNTING HOLE LOCATIONS M19527 13.1 0 1/4- 20 NUT (4 PLAC ES) NOTE: MOUNTING SCREWS CA 10/01 N NOT PROTR UDE MORE THAN 0.5 IN CHES INSIDE THE MACHINE. 11.8 4 3.50 ...

  • Lincoln Electric POWER WAVE IM845-A - page 38

    NOTES POWER WAVE 355M ...

  • Lincoln Electric POWER WAVE IM845-A - page 39

    NOTES POWER WAVE 355M ...

  • Lincoln Electric POWER WAVE IM845-A - page 40

    W ARNING AV I S O D E PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES. SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL F ABRICANTE P ARA ...

  • Lincoln Electric POWER WAVE IM845-A - page 41

    W ARNING AV I S O D E PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIPAMENTO E AS P AR TES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR. ● Keep your head out of fumes. ● Use ventilation or exhaust to remove fumes ...

  • Lincoln Electric POWER WAVE IM845-A - page 42

    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • ...

Produzent Lincoln Electric Kategorie Welder

Dokumente, die wir vom Produzenten des Geräts Lincoln Electric POWER WAVE IM845-A erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Lincoln Electric
- Bedienungsanleitungen POWER WAVE IM845-A
- Produktkarten Lincoln Electric
- Informationsbroschüren
- oder Energieetiketten Lincoln Electric POWER WAVE IM845-A
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Lincoln Electric POWER WAVE IM845-A.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Lincoln Electric POWER WAVE IM845-A, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Lincoln Electric POWER WAVE IM845-A. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Lincoln Electric POWER WAVE IM845-A ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Lincoln Electric POWER WAVE IM845-A, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Lincoln Electric POWER WAVE IM845-A hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Lincoln Electric POWER WAVE IM845-A verständlich ist.

Eine gänzliche Bedienungsanleitung von Lincoln Electric sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Lincoln Electric POWER WAVE IM845-A bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Lincoln Electric POWER WAVE IM845-A befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Lincoln Electric POWER WAVE IM845-A, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Lincoln Electric POWER WAVE IM845-A - die uns die ersten Schritte während der Nutzung von Lincoln Electric POWER WAVE IM845-A erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Lincoln Electric POWER WAVE IM845-A hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Lincoln Electric POWER WAVE IM845-A im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Lincoln Electric POWER WAVE IM845-A?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Lincoln Electric POWER WAVE IM845-A nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Lincoln Electric POWER WAVE IM845-A hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)