Bedienungsanleitung Wasp Bar Code WLP 4170 CCD

40 Seiten 0.65 mb
Download

Zur Seite of 40

Summary
  • Wasp Bar Code WLP 4170 CCD - page 1

    Wasp WLP 4170 CCD Programming Guide Please Read Note: The W asp WLP 4170 CCD Scanner is ready to scan the most popular bar codes out of the box. This manual should only be used to make changes in the configuration of the scanner for specific applications. This scanner does not require software or drivers to operate . The scanner enters data as k e ...

  • Wasp Bar Code WLP 4170 CCD - page 2

    © Copyright W asp T echnologies 2002. All rights reser ved. V ersion 1.0 No part of this publication may be reproduced or transmitted in any for m or by any means without the written permission of W asp T echnologies . The information contained in this document is subject to change without notice. W asp is a trademark of W asp T echnologies. All o ...

  • Wasp Bar Code WLP 4170 CCD - page 3

    T able of Contents Chapter 1. Introduction.............................................................................. 1 Chapter 2. Installation................................................................................ 2 Chapter 3. Quick Star t ..............................................................................3 Chapter 4. Bar Co ...

  • Wasp Bar Code WLP 4170 CCD - page 4

    1 Chapter 1 Introduction Bar coding is the most common Automated Data Collection (ADC) technology providing timely, error-free information that can be used to increase productivity , accuracy, and efficiency in the workplace. Virtually ev ery type of industry is using bar codes to replace k eyboard data entr y . Studies have shown that a proficient ...

  • Wasp Bar Code WLP 4170 CCD - page 5

    2 1. T urn off your computer . 2. Unplug your PC k e yboard cable and plug the male end (Din 5) of the W asp WLP 4170 CCD Scanner directly into your PC k e yboard port. Plug your k e yboard cable into the other end (female Din 5) of the the W asp WLP 4170 CCD Scanner. If your ke yboard and PC support a Din 6 connection, use the enclosed Din 5 to Di ...

  • Wasp Bar Code WLP 4170 CCD - page 6

    3 Y our W asp WLP 4170 CCD Scanner is ready to go . The default settings of the W asp WLP 4170 CCD Scanner ha v e been pre-programmed for the most common bar code configurations . Use the "Setup & Configuration" sections only to customize the Wasp settings . Tip: Use the pre-printed "Bar Code T est Symbols" in Appendix A on ...

  • Wasp Bar Code WLP 4170 CCD - page 7

    4 Bar codes are symbols consisting of a series of bars and spaces which can be applied to packages, cartons, bottles, and other commercial products . The bars and spaces in each symbol are grouped in such a w a y to represent a specific ASCII character or function. The interpretation of these groups is based on a particular set of rules called symb ...

  • Wasp Bar Code WLP 4170 CCD - page 8

    5 In order to configure W asp WLP 4170 CCD Scanner, you must familiariz e y ourself with the setup procedures on the following pages . The default settings of W asp WLP 4170 CCD Scanner are identified on each page and clearly mar k ed using an asterisk (*). The default settings have been preprogrammed f or the most common bar code configurations. U ...

  • Wasp Bar Code WLP 4170 CCD - page 9

    NOTE: Scanning these bar codes returns the scanner to the factory default settings 1. Scan “Begin ” 2. Scan “Default” to restore scanner to default settings 6 Tip: Use this configuration to restore the factory default settings if you are unsure how your scanner has been configured. The 'Factory Default' configuration is very usefu ...

  • Wasp Bar Code WLP 4170 CCD - page 10

    7 Setup & Configuration —Beep and Dela y Beep V olume Settings 00 None 01 Lowest 02 Low 03 Medium (Default) 04 Medium-High 05 High 06 High-Medium 07 Highest The 'Beep V olume' configuration changes the volume of the audible indicator of the WLP 4170 CCD Scanner . NOTE: For help in configuring these settings, consult the programming ...

  • Wasp Bar Code WLP 4170 CCD - page 11

    8 Setup & Configuration —Interc haracter Delay Inter character Delay Settings 00 Slo west 01 Slo w 02 Default 50 Medium 75 F ast 99 F astest The 'Intercharacter Delay' configuration sets the speed at which the WLP 4170 CCD Scanner sends data. The intercharacter delay should be changed only if the transfer rate cannot be maintained b ...

  • Wasp Bar Code WLP 4170 CCD - page 12

    9 Setup & Configuration —Ke yboar d W edg e 00 K e yboard Present* 01 Laptop/No ke yboard The 'Ke yboard W edge' configuration supports options related to managing ke yboard operations . The 'Function Code' option enables/disables support for your ke yboard function k eys. The 'Caps Lock' option toggles the case ...

  • Wasp Bar Code WLP 4170 CCD - page 13

    *Default 00 Default* 04 Continuous 10 Setup & Configuration —Scanning Modes Begin Set Scanning Mode Exit The 'Scanning Mode' option controls the trigger and LED settings for the WLP 4170 CCD Scanner. NOTE: For help in configuring these settings, consult the programming steps on pa ge 5. Continuous Mode * T rig g er with 10 Sec. Dela ...

  • Wasp Bar Code WLP 4170 CCD - page 14

    Preamble Data P ostamble 11 Setup & Configuration —Preamble and Postamble *Default The 'Preamble' and 'Postamble' options are used to add prefix and suffix characters to the bar code value . Up to 22 characters may be added for each option separately . Note: T his e xam pl e ill ustr ates h ow d at a wi ll be f o r m atted ...

  • Wasp Bar Code WLP 4170 CCD - page 15

    12 Setup & Configuration —Code 39 Cod e 39 is v a ri a b l e length an d is the most freq u entl y use d sym bol o g y in ind us t r i a l ba r code sys tem s to da y and is e x t e n s i v e l y use d wit hi n t he De pa r tm ent of D ef e n s e ( D O D ) . T he prin ci pal f eatur e i s to en cod e m es sages u sin g the full alph a n u m e ...

  • Wasp Bar Code WLP 4170 CCD - page 16

    13 Setup & Configuration —Code 39 (cont.) St anda r d Cod e 39 con ta i ns only 4 3 cha ra ct er s (0- 9 , A-Z , $, /, % , +, -, ., SP A C E ) an d ca n be e xtend e d to a 12 8 cha r act er symb o logy ( f ull ASCII ) by co mbini ng one of th e speci al ch ara c ters ( $, / , %, +) wi th a let te r ( A- Z) to f o r m t he ch a rac ters th a ...

  • Wasp Bar Code WLP 4170 CCD - page 17

    14 (continued on next page) *Default Setup & Configuration —Code128 On/Off V erify Check Digit Begin T ransmit Check Digit Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00 Enable 01* Disable 00 Enable 01* Disable 00* Enable 01 NOTE: For help in configuring these settings, consult the programming steps on pa ge 5. Cod e 12 8 is v a ri a ...

  • Wasp Bar Code WLP 4170 CCD - page 18

    15 Setup & Configuration —Code128 (cont.) Set Maximum Length Set Minimum Length Begin Format Exit Option Alpha/Numeric Entr y (Back Flap) 64 - Minimum 00 - 64 00* 64 - Maximum 00 - 64 00* Standard 00* UCC/EAN-128 01 NOTE: For help in configuring these settings, consult the programming steps on pa ge 5. Cod e 128 is t he mos t fle x i b l e of ...

  • Wasp Bar Code WLP 4170 CCD - page 19

    16 Setup & Configuration —UPC-A On/Off V erify Check Digit Begin T ransmit Check Digit Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00 Enable 01* Disable 00 Enable (two digits) 01* Disable 00 Enable 01* NOTE: For help in configuring these settings, consult the programming steps on pa ge 5. UPC-A (Universal Product Code-A) is fixed len ...

  • Wasp Bar Code WLP 4170 CCD - page 20

    17 Setup & Configuration —UPC-A (cont.) Begin Supplement Digits T r uncate Leading Zero Exit NOTE: For help in configuring these settings, consult the programming steps on pa ge 5. The first six digits of the UPC-A bar code are assigned from the Uniform Code Council (UCC).The next five digits are assigned by the manufacturer, and the final di ...

  • Wasp Bar Code WLP 4170 CCD - page 21

    18 (continued on next page) *Default Setup & Configuration —UPC-E On/Off V erify Check Digit Begin T ransmit Check Digit Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00 Enable 01* Disable 00 Enable 01* Disable 00 Enable 01* NOTE: For help in configuring these settings, consult the programming steps on pa ge 5. UPC-E (Universal Product ...

  • Wasp Bar Code WLP 4170 CCD - page 22

    19 *Default Setup & Configuration —UPC-E (cont.) Supplement Digits T runcate Leading Zero Begin Expansion Exit NOTE: For help in configuring these settings, consult the programming steps on pa ge 5. The printed value of the UPC-E code is a twelve digit code . The nominal height for the UPC- E bar code is one inch.The reduced size is 80% of th ...

  • Wasp Bar Code WLP 4170 CCD - page 23

    20 (continued on next page) *Default Setup & Configuration —EAN-13 On/Off V erify Check Digit Begin T ransmit Check Digit Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00 Enable 01* Disable 00 Enable 01* Disable 00 Enable 01* NOTE: For help in configuring these settings, consult the programming steps on pa ge 5. The EAN/JAN-13 (Europea ...

  • Wasp Bar Code WLP 4170 CCD - page 24

    21 Setup & Configuration —EAN-13 (cont.) NOTE: For help in configuring these settings, consult the programming steps on pa ge 5. The EAN/JAN-13 (European Article Number/Japanese Article Number) is fixed length and is similar to the UPC-A symbology, but encodes a 13th digit. The nominal height for the EAN/JAN-8 bar code is one inch.The reduced ...

  • Wasp Bar Code WLP 4170 CCD - page 25

    22 (continued on next page) *Default Setup & Configuration —EAN-8 On/Off V erify Check Digit Begin T ransmit Check Digit Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00 Enable 01* Disable 00 Enable 01* Disable 00 Enable 01* NOTE: For help in configuring these settings, consult the programming steps on pa ge 5. The EAN/JAN-8 is fixed l ...

  • Wasp Bar Code WLP 4170 CCD - page 26

    23 *Default Setup & Configuration —EAN-8 (cont.) Supplement Digits T r uncate Leading Zero Begin Expansion Exit Option Alpha/Numeric Entr y (Back Flap) None 00* 2 digits 01 5 digits 02 2 / 5 digits 03 or None Disable 00* Enable 01 Disable 00* Enable 01 NOTE: For help in configuring these settings, consult the programming steps on pa ge 5. The ...

  • Wasp Bar Code WLP 4170 CCD - page 27

    24 Setup & Configuration —Code 93 On/Off V erify Check Digit Begin T ransmit Check Digit Set Maximum Length Set Minimum Length Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00* Enable 01 Disable 00 Enable (two digits) 01* Disable 00* Enable 01 64 - Minimum 64 - 00 00* 00 - Maximum 00 - 64 00* NOTE: For help in configuring these setting ...

  • Wasp Bar Code WLP 4170 CCD - page 28

    25 Setup & Configuration —Interleaved 2 of 5 *Default Begin On/Off V erify Check Digit T ransmit Check Digit Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00 Enable 01* Disable 00 Enable 01* Disable 00* Enable 01 NOTE: For help in configuring these settings, consult the programming steps on pa ge 5. I n t e rl e a ved 2 o f 5 i s a v a ...

  • Wasp Bar Code WLP 4170 CCD - page 29

    26 Setup & Configuration —Codabar *Default On/Off V erify Check Digit Begin T ransmit Check Digit Set Maximum Length Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00 Enable 01* Disable 00* Enable 01 Disable 00* Enable 01 64 - minimum 64 - 00 00* NOTE: For help in configuring these settings, consult the programming steps on pa ge 5. Cod ...

  • Wasp Bar Code WLP 4170 CCD - page 30

    27 *Default Setup & Configuration —Codabar (cont.) Set Minimum Length Start/Stop T ype Begin Start/Stop T ransmission Exit Option Alpha/Numeric Entr y (Back Flap) 00 - Maximum 00 - 64 00* ABCD/ABCD 00* abcd/abcd 01 ABCD/TN*E 02 Abcd/tn*e 03 Disable 00* Enable 01 NOTE: For help in configuring these settings, consult the programming steps on pa ...

  • Wasp Bar Code WLP 4170 CCD - page 31

    28 Setup & Configuration —MSI Plesse y On/Off V erify Check Digit Begin T ransmit Check Digit Set Maximum Length Set Minimum Length Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00* Enable 01 Disable 00* Mod 10 01 Mod 10/10 02 Mod 11/10 03 Disable 00* Enable 01 64 - Minimum 64 - 00 00* 00 - Maximum 00 - 64 00* NOTE: For help in configu ...

  • Wasp Bar Code WLP 4170 CCD - page 32

    29 Setup & Configuration —PDF417 On/Off Begin Exit Option Alpha/Numeric Entr y (Back Flap) Disable 00* Enable 01 NOTE: For help in configuring these settings, consult the programming steps on pa ge 5. PDF417 is a 2D variable length symbology that can encode virtually any letter, number, or character . Each character consists of 4 bars and 4 s ...

  • Wasp Bar Code WLP 4170 CCD - page 33

    30 Code 39* Interleav ed 2 of 5 Codabar* Code 128* MSI/Plessey Code 93* Setup & Configuration —Bar Code T est Symbols—Appendix A Note: Make sure that the appropriate bar code symbology is configured properly and enabled before trying to scan. Use the 'Bar Code Symbologies' configuration beginning on page 14 to enable specific symb ...

  • Wasp Bar Code WLP 4170 CCD - page 34

    31 UPC-A* UPC-E* UPC-E w/5 digit supplement UPC-E w/2 digit supplement UPC-A w/2 digit supplement UPC-A w/5 digit supplement Setup & Configuration —Bar Code T est Symbols—Appendix A (cont.) *Default ...

  • Wasp Bar Code WLP 4170 CCD - page 35

    EAN/JAN 13* EAN/JAN 13 w/2 digit supplement EAN/JAN 13 w/5 digit supplement 3 Setup & Configuration —Bar Code T est Symbols—Appendix A (cont.) *Def ault ...

  • Wasp Bar Code WLP 4170 CCD - page 36

    EAN/JAN 8* EAN/JAN 8+5 w/5 digit supplement EAN/JAN 8 w/2 digit supplement PDF417 33 Setup & Configuration —Bar Code T est Symbols—Appendix A (cont.) *Default ...

  • Wasp Bar Code WLP 4170 CCD - page 37

    34 Setup & Configuration —WLP 4170 CCD Specifications MODEL WLP 4170 OPTICAL Scanning Width 3.2 in (120 mil) Depth of Field 0 to 3 in (0 to 200 mil) Scan Rate 200 scans / second ELECTRICAL Light Source 660 nm red visible LED Sensor 2,048 pixel CCD arr ay Operating V oltage +5 VDC ± 0.25V Current Consumption Standby 100 mA @ 5 VDC / Sleep 25 ...

  • Wasp Bar Code WLP 4170 CCD - page 38

    35 W asp Bar Code products are warranted against defects in workmanship and materials for a period of one year from the date of shipment, provided that the product remains unmodified and is operated under normal and proper conditions. This warranty is limited to repair or replacement at W asp Bar Code's option, with reasonable promptness after ...

  • Wasp Bar Code WLP 4170 CCD - page 39

    43 C 44 D 45 E 46 F 47 G 48 H 49 I 4A J 4B K 4C L 4D M 4E N 4F O 50 P 51 Q 52 R 53 S 54 T 55 U 56 V 57 W 58 X 59 Y 5A Z 5B [ 5C 5D ] 5E ^ 5F _ 60 ` 61 a 62 b 23 # 24 $ 25 % 26 & 27 ‘ 28 ( 29 ) 2A ★ 2B + 2C 2D - 2E . 2F / 30 0 31 1 32 2 33 3 34 4 35 5 36 6 37 7 38 8 39 9 3A : 3B ; 3C < 3D = 3E > 3F ? 40 @ 41 A 42 B 36 ASCII Code T able ...

  • Wasp Bar Code WLP 4170 CCD - page 40

    0 1 2 3 4 5 6 7 8 9 A B C D E F FINISH BACK COVER BAR CODES ...

Produzent Wasp Bar Code Kategorie Scanner

Dokumente, die wir vom Produzenten des Geräts Wasp Bar Code WLP 4170 CCD erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Wasp Bar Code
- Bedienungsanleitungen WLP 4170 CCD
- Produktkarten Wasp Bar Code
- Informationsbroschüren
- oder Energieetiketten Wasp Bar Code WLP 4170 CCD
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Wasp Bar Code WLP 4170 CCD.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Wasp Bar Code WLP 4170 CCD, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Wasp Bar Code WLP 4170 CCD. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Wasp Bar Code WLP 4170 CCD ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Wasp Bar Code WLP 4170 CCD, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Wasp Bar Code WLP 4170 CCD hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Wasp Bar Code WLP 4170 CCD verständlich ist.

Eine gänzliche Bedienungsanleitung von Wasp Bar Code sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Wasp Bar Code WLP 4170 CCD bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Wasp Bar Code WLP 4170 CCD befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Wasp Bar Code WLP 4170 CCD, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Wasp Bar Code WLP 4170 CCD - die uns die ersten Schritte während der Nutzung von Wasp Bar Code WLP 4170 CCD erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Wasp Bar Code WLP 4170 CCD hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Wasp Bar Code WLP 4170 CCD im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Wasp Bar Code WLP 4170 CCD?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Wasp Bar Code WLP 4170 CCD nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Wasp Bar Code WLP 4170 CCD hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)