Bedienungsanleitung Friedrich MS36Y3F

25 Seiten 2.26 mb
Download

Zur Seite of 25

Summary
  • Friedrich MS36Y3F - page 1

    CONTENTS SPECIFICATIONS .................. 1 OUTLINE AND DIMENSIONS ......... 2 REFRIGERANT SYSTEM DIAGRAM .... 4 CIRCUIT DIAGRAM ................. 5 INDOOR PCB CIRCUIT DIAGRAM ..... 7 OUTDOOR PCB CIRCUIT DIAGRAM ... 8 ERROR CONTENTS ............... 11 DISASSEMBLY ILLUSTRATION ...... 13 PARTS LIST ...................... 21 ACCESSORIES ............. ...

  • Friedrich MS36Y3F - page 2

    Pipe length 49 ft. (15 m) 4 lb 14 oz (2,200 g) 66 ft. (20 m) 5 lb 5 oz (2,400 g) 98 ft. (30 m) 6 lb 3 oz (2,800 g) 131 ft. (40 m) 7 lb 1 oz (3,200 g) 164 ft. (50 m) 7 lb 15 oz (3,600 g) ADDITIONAL CHARGE FULL CHARGE 0.43 oz / ft. (4 0g/m ) SPECIFICA TIONS TYPE COOLING & HEA TING INDOOR UNIT MS36Y3F OUTDOOR UNIT MR36Y3F COOLING CAP ACITY 34,100 ...

  • Friedrich MS36Y3F - page 3

    OUTLINE AND DIMENSIONS 65-1/2" (1,660) 9-1/2" (240) 27-5/8" (700) 63" (1,600) 5-1/8" (130) 11-7/8" (300) Unit : inch (mm) INDOOR UNIT 2006.02.28 2 ...

  • Friedrich MS36Y3F - page 4

    Unit : inch (mm) OUTDOOR UNIT 3"(77) 35-1/2" (900) 32-3/4" (830) 17-3/8" (440) 7/8" (21) 3/8" (9) 15-3/4" (400) 13" (330) 1-1/4" (31) 1/2" (12) 7-3/4" (196) 5-3/4" (147) 6-3/4" (170) 3-7/8" (99) 14-5/8" (370) 25-5/8" (650) Air Flow 2006.02.28 3 ...

  • Friedrich MS36Y3F - page 5

    Evaporator REFRIGERANT SYSTEM DIAGRAM OUTDOOR UNIT Pressure Check Valve Condenser 4-way Valve High Pressure Switch Accumulator Muffler Compressor Expansion Valve Refrigerant Pipe 9.52mm (3/8") Charging Valve Charging Valve Refrigerant Pipe 15.88mm (5/8") INDOOR UNIT Strainer Strainer : COOL : HEAT 2006.02.28 4 ...

  • Friedrich MS36Y3F - page 6

    CIRCUIT DIAGRAM INDOOR UNIT 2006.02.28 5 ORANGE YELLOW WHITE RED BROWN ORANGE YELLOW WHITE RED BROWN ORANGE YELLOW WHITE RED BROWN BLUE PURPLE GRAY GRAY PURPLE BLUE BLACK WHITE RED WHITE WHITE GREEN WHITE WHITE WHITE BLACK BLACK BLACK RED RED BLACK BLACK GRAY GRAY CN6 CN7 CN8 CN15 CN13 CN16 CN5 CN11 CN10 CN4 CN17 CN1 CN201 1 2 3 4 5 6 7 8 1 2 3 4 5 ...

  • Friedrich MS36Y3F - page 7

    OUTDOOR UNIT ORANGE YELLOW WHITE BLUE BROWN RED BLUE YELLOW WHITE BLACK RED BLACK BLACK RED RED BLUE BROWN BLACK BLACK BROWN RED GREEN BLACK BLACK WHITE WHITE WHITE BROWN BLACK BLACK RED BLACK WHITE ORANGE ORANGE BLACK RED YELLOW YELLOW BLUE ORANGE RED BROWN BROWN WHITE BLACK BLACK BLACK BLACK RED RED WHITE WHITE 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 1 ...

  • Friedrich MS36Y3F - page 8

    14V 5V R57 1.0K <1/10W> C39 0.1 <F> CR5 1000P <R> R50 10K <1/10W> R77 - R79 10K <1/10W> x 3 BZ1 PKM13EPY-4000 5V R21 - R24 10K <1/10W> x 4 5V 5V C22 - C25 0.01 <F> x 4 R25 - R28 1.0K <1/10W> x 4 I C6 (1/7) uPA2003GR R56 I C7 BR93LC46RF DO DI SK CS VCC NC NC GND 1 2 3 4 5 6 7 8 6 11 CN9-1 CN9-2 CN9-3 C ...

  • Friedrich MS36Y3F - page 9

    AC230V 60Hz TERMINAL HP-T3061-3 Model : MR36Y3F OUTDOOR PCB CIRCUIT DIAGRAM POWER SUPPL Y PCB K04BA-0501HUE-P0 CONTROLLER PCB ASSY K04A W-0504HUE-C1 INVERTER ASSY EZ-005HHUE 2006.03.13 8 ...

  • Friedrich MS36Y3F - page 10

    600/450V x 4 Model : MR36Y3F CONTROLLER PCB ASSEMBL Y ( MAIN PCB ) K04AW -0504HUE-C1 2006.02.28 9 ...

  • Friedrich MS36Y3F - page 11

    5V TM101 TM102 C1 12 0.015 <YE> C1 13 0.015 <YE> C1 1 1 3.3 <LE> L4 RCH4730-021PF07 C107 3.3 <LE> TM100 L2 N200500K1D7C CT1 CT -1B 5V D60 DAN217U C64 0.1 <F> R68 22K <1/10W> C65 0.1 <F> VR1 B2K + R61 3.74K <1/10W> (1%) C60 220/16V <PJ> R60 1.0K <1/10W> (1%) SA100 RA-302M C106 3.3 <LE> ...

  • Friedrich MS36Y3F - page 12

    ERROR CONTENTS (Indoor unit) Indoor EEPROM abnormal Outdoor EEPROM abnormal Indoor room temperature sensor open Indoor room temperature sensor shortcircuited Indoor heat exchanger temperature sensor open Indoor heat exchanger temperature sensor shortcircuited Float switch operated Indoor signal abnormal Outdoor signal abnormal Indoor fan abnormal O ...

  • Friedrich MS36Y3F - page 13

    SPECIAL INSTALLATION SETTING PUMP DOWN (Refrigerant collecting operation) ERROR CONTENTS (outdoor unit) 1. Make a TEST RUN in accordance with the in- stallation instruction sheet for the indoor unit. 2. OUTDOOR UNIT LEDS Error contents Communication error (Indoor unit - Outdoor unit) Discharg pipe temperature sensor Outdoor heat exchanger temperatu ...

  • Friedrich MS36Y3F - page 14

    DISASSEMBLY ILLUSTRATION INDOOR UNIT Model : MS36Y3F 345-2 240-2 240-1 876-1 345-1 338-1 338-2 8 403 122 286 174 386 138 752 735 329 321 69 684 435 434 228 229 580 506 407 505 408 361 396 160 63 868 743 240 146 383 762 74 448 472 223 755 56 388 164 403 181 761 174 387 12 382 379 109 126 122 286 384 2006.02.28 13 ...

  • Friedrich MS36Y3F - page 15

    407 434 435 408 505 506 69 876-1 387 160 91 91 91 321 386 361 Model : MS36Y3F 2006.02.28 14 ...

  • Friedrich MS36Y3F - page 16

    63 868 385 763 227 321 387 436 424 684 438 876-2 Model : MS36Y3F 2006.02.28 15 ...

  • Friedrich MS36Y3F - page 17

    253-3 34 195 253-4 253-5 253-6 253-7 236 234 380 185-1 625 187 472 448 223 381-4 253-2 253-1 875 815-1 195 Model : MS36Y3F 2006.02.28 16 ...

  • Friedrich MS36Y3F - page 18

    1 6 7 3 4 5 2 Model : MR36Y3F 2006.02.28 17 ...

  • Friedrich MS36Y3F - page 19

    17 18 10 13 9 15 14 8 Model : MR36Y3F 2006.02.28 18 ...

  • Friedrich MS36Y3F - page 20

    22 23 31 20 29 12 28 12 19 24 26 27 25 30 Model : MR36Y3F 2006.02.28 19 ...

  • Friedrich MS36Y3F - page 21

    37 38 33 34 36 35 Model : MR36Y3F 2006.02.28 20 ...

  • Friedrich MS36Y3F - page 22

    INDOOR UNIT 8 Air Filter 12 Base Assy Ref. Description Part No. Ref. Description Part No. 9359739005 9359680000 34 Capacitor 9900270216 56 Sirocco Fan Assy 63 Panel (Front) 69 Louver 74 Intake Grille 91 Hinge 109 Casing 122 Bearing-B Assy 126 Bracket (Motor) 138 Separate Wall 146 Evaporator Assy 160 Drain Pan Sub Assy 164 Fan Motor Assy-IN 174 Hang ...

  • Friedrich MS36Y3F - page 23

    OUTDOOR UNIT 1 T op Panel Sub Assy 2 Front Panel 3 Fan Guard 4 Grip Side 5 Service Panel Sub Assy 6 Right Panel Sub Assy 7 LABEL (FRIEDRICH) 8 Propeller Fan Assy 9 Motor , Induction 10 Condenser-A Assy 12 Strainer Assy 13 Separate Wall Assy 14 Cap Foot 15 Base Assy 17 3-W ay V alve Assy 18 3-W ay V alve Assy 19 Check Joint Assy 20 Compressor Assy 2 ...

  • Friedrich MS36Y3F - page 24

    ACCESSORIES Q'ty 1 2 1 2 1 1 Coupler heat insulator (large) Coupler heat insulator (small) Nylon fastener Special nut A (large flange) Special nut B (small flange) Installation template Auxiliary pipe assembly For indoor side pipe joint (Gas pipe) For indoor side pipe joint (Liquid pipe) For fixing the coupler heat insulator For installing ind ...

  • Friedrich MS36Y3F - page 25

    0602G3034 ...

Produzent Friedrich Kategorie Air Conditioner

Dokumente, die wir vom Produzenten des Geräts Friedrich MS36Y3F erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Friedrich
- Bedienungsanleitungen MS36Y3F
- Produktkarten Friedrich
- Informationsbroschüren
- oder Energieetiketten Friedrich MS36Y3F
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Friedrich MS36Y3F.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Friedrich MS36Y3F, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Friedrich MS36Y3F. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Friedrich MS36Y3F ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Friedrich MS36Y3F, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Friedrich MS36Y3F hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Friedrich MS36Y3F verständlich ist.

Eine gänzliche Bedienungsanleitung von Friedrich sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Friedrich MS36Y3F bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Friedrich MS36Y3F befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Friedrich MS36Y3F, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Friedrich MS36Y3F - die uns die ersten Schritte während der Nutzung von Friedrich MS36Y3F erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Friedrich MS36Y3F hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Friedrich MS36Y3F im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Friedrich MS36Y3F?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Friedrich MS36Y3F nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Friedrich MS36Y3F hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)