    System Indoor Unit SERVICE MANUAL R410A MODEL : ARNU Series URNU Series CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel. Internal Use Only http://biz.lgservice.com R410A ...

  • Haier R410A - page 2

    - 2 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only Air Conditioner Ser vice Manual T ABLE OF CONTENTS Safety Precautions ............................................................................................................................3 P art 1 General Information . ...

  • Haier R410A - page 3

    - 3 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only P ar t 1 General Inf ormation 1. Model Names .............................................4 2. External Appearance .................................5 3. Nomenc lature .............................................6 ...

  • Haier R410A - page 4

    Model Names - 4 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 1. Model Names SE Wall Mounted (General) S5 SE Mirror S3 SF 1 Way TJ 2 Way TL TE 4 Way TP TN TM BH BG High Static BR B8 B1 Low Static B2 B3 B4 Ceiling & Floor VE Ceiling Suspended VJ CE With Case CF CE CF Capa ...

  • Haier R410A - page 5

    Exter nal Appear ance - 5 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 2. External Appearance Wall Mounted ART COOL Mirror Ceiling Cassette- 1Way Ceiling Cassette- 4Way Ceiling & Floor Ceiling Suspended ARNU07GTJ*2 ARNU09GTJ*2 ARNU12GTJ*2 Ceiling Cassette -2Way ARNU18GT ...

  • Haier R410A - page 6

    Nomenclature - 6 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 3. Nomenc lature ARN U G 07 A TJ 2 Serial Number Chassis Name Electrical Ratings 1:1Ø, 115V, 60Hz 2: 1Ø, 220V, 60Hz 6:1Ø, 220 ~ 240V, 50Hz 7: 1Ø, 100V, 50/60Hz G:1Ø, 220 ~ 240V, 50Hz / 220V 60Hz Total Coolin ...

  • Haier R410A - page 7

    - 7 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only P ar t 2 Indoor Units Ceiling Cassette 1 W a y .................................................................................8 2 W a y ...............................................................................13 4 W a ...

  • Haier R410A - page 8

    - 8 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 1. Functions ......................................................................................9 2. Operation Details ........................................................................10 3. Dimensions .............. ...

  • Haier R410A - page 9

    - 9 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only Specification 1. Functions Indoor Unit Operation ON/OFF by Remote controller Sensing the Room Temperature Room temperature control Starting Current Control Indoor Fan Speed Control Soft Dry Operation Mode Airflow Direction Co ...

  • Haier R410A - page 10

    - 10 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 2. Operation Detail ■ A uto Swing Control • This function is to swing the louver up and down automatically. ■ Soft-Dry Operation • The indoor fan speed is automatically set to the low, so the shift of the indoor fan ...

  • Haier R410A - page 11

    - 11 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only ■ Heating Mode Operation The unit will operate according to the setting by the remote controller and the operation diagram is shown as following. ■ Hot-star t Contr ol The indoor fan does no rotate until the evaporator p ...

  • Haier R410A - page 12

    - 12 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 3. Dimensions Dimensions 4 2 1 3 860 32.8 410 344.4 961.2 16.5 19.1 50 83 36 30 242.5 173 151 100 56 83 138 131 110 16.4 . 198.8 480 939 1070 76, Seongsan-dong, Changwon City , Gyeongnam, 641-713, K orea www .lgeaircon.com C ...

  • Haier R410A - page 13

    - 13 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 1. Functions ....................................................................................14 2. Operation Details ........................................................................15 3. Dimensions .............. ...

  • Haier R410A - page 14

    - 14 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 1. Functions Indoor Unit Operation ON/OFF by Remote controller Sensing the Room Temperature Room temperature control Starting Current Control Indoor Fan Speed Control Soft Dry Operation Mode Airflow Direction Control Deice ( ...

  • Haier R410A - page 15

    - 15 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 2. Operation Detail ■ A uto Swing Control • This function is to swing the louver up and down automatically. ■ Soft-Dry Operation • The indoor fan speed is automatically set to the low, so the shift of the indoor fan ...

  • Haier R410A - page 16

    - 16 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only ■ Heating Mode Operation The unit will operate according to the setting by the remote controller and the operation diagram is shown as following. ■ Hot-star t Contr ol The indoor fan does no rotate until the evaporator p ...

  • Haier R410A - page 17

    - 17 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 3. Dimensions Dimensions 830 A B 47.9 275 550 69.5 889.2 1050 640 28.5 4 2 1 3 TL A B 225 126.5 76, Seongsan-dong, Changwon City , Gyeongnam, 641-713, K orea www .lgeaircon.com CHASSIS CODE: TL Ceiling Cassette 2-wa y ARNU18 ...

  • Haier R410A - page 18

    - 18 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 1. Functions ....................................................................................19 2. Operation Details ........................................................................20 3. Dimensions .............. ...

  • Haier R410A - page 19

    - 19 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 1. Functions Indoor Unit Operation ON/OFF by Remote controller Sensing the Room Temperature Room temperature control Starting Current Control Indoor Fan Speed Control Soft Dry Operation Mode Airflow Direction Control Deice ( ...

  • Haier R410A - page 20

    - 20 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 2. Operation Detail ■ A uto Swing Control • This function is to swing the louver up and down automatically. ■ Soft-Dry Operation • The indoor fan speed is automatically set to the low, so the shift of the indoor fan ...

  • Haier R410A - page 21

    - 21 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only ■ Heating Mode Operation The unit will operate according to the setting by the remote controller and the operation diagram is shown as following. ■ Hot-star t Contr ol The indoor fan does no rotate until the evaporator p ...

  • Haier R410A - page 22

    - 22 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 3. Dimensions Dimensions 269 670 30 570 269 90 90 120.4 30 521 670 570 450 40 110 110 670 670 4 1 3 2 5 6 76, Seongsan-dong, Changwon City , Gyeongnam, 641-713, K orea www .lgeaircon.com CHASSIS CODE: TE Ceiling Cassette 4-w ...

  • Haier R410A - page 23

    - 23 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 1. Functions ....................................................................................24 2. Operation Details ........................................................................25 3. Dimensions .............. ...

  • Haier R410A - page 24

    - 24 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 1. Functions Indoor Unit Operation ON/OFF by Remote controller Sensing the Room Temperature Room temperature control Starting Current Control Indoor Fan Speed Control Soft Dry Operation Mode Airflow Direction Control Deice ( ...

  • Haier R410A - page 25

    - 25 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 2. Operation Detail ■ A uto Swing Control • This function is to swing the louver up and down automatically. ■ Soft-Dry Operation • The indoor fan speed is automatically set to the low, so the shift of the indoor fan ...

  • Haier R410A - page 26

    - 26 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only ■ Heating Mode Operation The unit will operate according to the setting by the remote controller and the operation diagram is shown as following. ■ Hot-star t Contr ol The indoor fan does no rotate until the evaporator p ...

  • Haier R410A - page 27

    - 27 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 3. Dimensions Dimensions 76, Seongsan-dong, Changwon City , Gyeongnam, 641-713, K orea www .lgeaircon.com CHASSIS CODE: TP Ceiling Cassette 4-wa y ARNU24GTP*2 ARNU28GTP*2 Note 1. Unit should be installed in compliance with t ...

  • Haier R410A - page 28

    - 28 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only Dimensions 840 126 62 R35 246 195 A direction View 76, Seongsan-dong, Changwon City , Gyeongnam, 641-713, K orea www .lgeaircon.com CHASSIS CODE: TN Ceiling Cassette 4-wa y ARNU36GTN*2 Note 1. Unit should be installed in com ...

  • Haier R410A - page 29

    - 29 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only Dimensions 76, Seongsan-dong, Changwon City , Gyeongnam, 641-713, K orea www .lgeaircon.com CHASSIS CODE: TM Ceiling Cassette 4-wa y ARNU42GTM*2 ARNU48GTM*2 Note 1. Unit should be installed in compliance with the installatio ...

  • Haier R410A - page 30

    - 30 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 1. Functions ....................................................................................31 2. Operation Details ........................................................................32 3. Dimensions .............. ...

  • Haier R410A - page 31

    - 31 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only Functions 1. Functions • Room temperature sensor. (THERMISTOR) • Maintains the room temperature in accordance with the Setting Temp. • Indoor fan is delayed for 5 sec at the starting. • High, Med, Low, CHAOS • Inte ...

  • Haier R410A - page 32

    Operation Details - 32 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 2. Operation Details DISPLA Y 1) High quality LCD remote controller supplied Operation Indicator • On while in appliance operation, off while in appliance pause Timer Indicator • On while in timer mode ...

  • Haier R410A - page 33

    Operation Details - 33 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only ■ Health y Dehumidification Mode • When the dehumidification operation input by the remote controller is received, the intake air temperature is detected and the setting temp is automatically set accord ...

  • Haier R410A - page 34

    Operation Details - 34 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only ■ Fuzzy Operation (Outdoor unit H/P Model) • When any of operation mode is not selected like the moment of the power on or when 3 hrs has passed since the operation off, the operation mode is selected. ...

  • Haier R410A - page 35

    Operation Details - 35 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only • At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the intake air temp at that time. 26 ° C ≤ Intake Air Temp => 25 ° C 24 ° C ≤ Intake Ai ...

  • Haier R410A - page 36

    Operation Details - 36 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only ■ Off-Timer <=> On-Timer Operation • When the set time is reached after the on/off time is input by the remote controller, the on/off-timer operation is carried out according to the set time. ■ ...

  • Haier R410A - page 37

    Operation Details - 37 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only - State of Operation ON/OFF - Operation Mode/Setting Temp/Selected Airflow Speed - Sleep Timer Mode/Remaining Time of Sleep Timer (unit of hour) ■ Forced Operation (Outdoor unit C/O Model) • To operate ...

  • Haier R410A - page 38

    Operation Details - 38 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only ■ Buzzer Sounding Operation • When the appliance-operation key is input by the remote controller, the short “ beep-beep- ” sounds. • When the appliance-pause key is input by the remote controller, ...

  • Haier R410A - page 39

    Dimensions - 39 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 3. Dimensions 76, Seongsan-dong, Changwon City , Gyeongnam, 641-713, K orea www .lgeaircon.com CHASSIS CODE: SE AR T COOL Mirror ARNU07GSE*2 ARNU09GSE*2 ARNU12GSE*2 ARNU15GSE*2 W Model ARNU07GSE*2 ARNU09GSE*2 ARNU ...

  • Haier R410A - page 40

    Dimensions - 40 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 76, Seongsan-dong, Changwon City , Gyeongnam, 641-713, K orea www .lgeaircon.com CHASSIS CODE: S3 AR T COOL Mirror ARNU18GS3*2 ARNU24GS3*2 W Model ARNU18GS3*2 ARNU24GS3*2 HD 1170 315 173 Note 1. Unit should be ins ...

  • Haier R410A - page 41

    - 41 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 1. Functions ....................................................................................42 2. Operation Details ........................................................................43 3. Dimensions .............. ...

  • Haier R410A - page 42

    Functions - 42 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 1. Functions • Room temperature sensor. (THERMISTOR) • Maintains the room temperature in accordance with the Setting Temp. • Indoor fan is delayed for 5 sec at the starting. • High, Med, Low, CHAOS • Inte ...

  • Haier R410A - page 43

    Operation Details - 43 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 2. Operation Details DISPLA Y 1) High quality LCD remote controller supplied Operation Indicator • On while in appliance operation, off while in appliance pause Timer Indicator • On while in timer mode ...

  • Haier R410A - page 44

    Operation Details - 44 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only ■ Health y Dehumidification Mode • When the dehumidification operation input by the remote controller is received, the intake air temperature is detected and the setting temp is automatically set accord ...

  • Haier R410A - page 45

    Operation Details - 45 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only ■ Fuzzy Operation (Outdoor unit H/P Model) • When any of operation mode is not selected like the moment of the power on or when 3 hrs has passed since the operation off, the operation mode is selected. ...

  • Haier R410A - page 46

    Operation Details - 46 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only • At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the intake air temp at that time. 26 ° C ≤ Intake Air Temp => 25 ° C 24 ° C ≤ Intake Ai ...

  • Haier R410A - page 47

    Operation Details - 47 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only ■ Off-Timer <=> On-Timer Operation • When the set time is reached after the on/off time is input by the remote controller, the on/off-timer operation is carried out according to the set time. ■ ...

  • Haier R410A - page 48

    Operation Details - 48 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only - State of Operation ON/OFF - Operation Mode/Setting Temp/Selected Airflow Speed - Sleep Timer Mode/Remaining Time of Sleep Timer (unit of hour) ■ Forced Operation (Outdoor unit C/O Model) • To operate ...

  • Haier R410A - page 49

    Operation Details - 49 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only ■ Buzzer Sounding Operation • When the appliance-operation key is input by the remote controller, the short “ beep-beep- ” sounds. • When the appliance-pause key is input by the remote controller, ...

  • Haier R410A - page 50

    - 50 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only Dimensions 3. Dimensions 76, Seongsan-dong, Changwon City , Gyeongnam, 641-713, K orea www .lgeaircon.com CHASSIS CODE: SF AR T COOL Galler y ARNU07GSF*2 ARNU09GSF*2 ARNU12GSF*2 W Model ARNU07GSF*2 ARNU09GSF*2 ARNU12GSF*2 HD ...

  • Haier R410A - page 51

    - 51 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 1. Funtions ......................................................................................52 2. Operation Details ........................................................................53 3. Dimensions ............. ...

  • Haier R410A - page 52

    - 52 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 1. Funtions Indoor Unit Operation ON/OFF by Remote controller Sensing the Room Temperature Room temperature control Starting Current Control Indoor Fan Speed Control Soft Dry Operation Mode Deice (defrost) control (Heating) ...

  • Haier R410A - page 53

    - 53 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 2. Operation Details ■ Soft-Dry Operation • The indoor fan speed is automatically set to the low, so the shift of the indoor fan speed is impossible because of already being set to the best speed for Dry Operation by mic ...

  • Haier R410A - page 54

    - 54 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only Operation Details ■ Heating Mode Operation The unit will operate according to the setting by the remote controller and the operation diagram is shown as following. Thermal Outdoor fan Indoor fan 4way valve Setting Temperat ...

  • Haier R410A - page 55

    - 55 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only ■ Hot-Star t Contr ol • The indoor fan does not rotate until the indoor unit Hex-Exchanger temperature reaches 30 ° C. • The operation diagram is as following. Operation Details ON ON Off Off Low Low 1 min Hotstart On ...

  • Haier R410A - page 56

    - 56 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 3. Dimensions Dimensions 76, Seongsan-dong, Changwon City , Gyeongnam, 641-713, K orea www .lgeaircon.com CHASSIS CODE: B1/B2 Ceiling Concealed Duct (Low Static) ARNU07GB1G2 ARNU09GB1G2 ARNU12GB1G2 ARNU15GB1G2 ARNU18GB2G2 AR ...

  • Haier R410A - page 57

    - 57 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 1. Funtions ......................................................................................58 2. Operation Details ........................................................................59 3. Dimensions ............. ...

  • Haier R410A - page 58

    - 58 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 1. Funtions Indoor Unit Operation ON/OFF by Remote controller Sensing the Room Temperature Room temperature control Starting Current Control Indoor Fan Speed Control Soft Dry Operation Mode Deice (defrost) control (Heating) ...

  • Haier R410A - page 59

    - 59 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 2. Operation Details ■ Soft-Dry Operation • The indoor fan speed is automatically set to the low, so the shift of the indoor fan speed is impossible because of already being set to the best speed for Dry Operation by mic ...

  • Haier R410A - page 60

    - 60 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only Operation Details ■ Heating Mode Operation The unit will operate according to the setting by the remote controller and the operation diagram is shown as following. Thermal Outdoor fan Indoor fan 4way valve Setting Temperat ...

  • Haier R410A - page 61

    - 61 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only ■ Hot-Star t Contr ol • The indoor fan does not rotate until the indoor unit Hex-Exchanger temperature reaches 30 ° C. • The operation diagram is as following. Operation Details ON ON Off Off Low Low 1 min Hotstart On ...

  • Haier R410A - page 62

    - 62 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 3. Dimensions Dimensions 76, Seongsan-dong, Changwon City , Gyeongnam, 641-713, K orea www .lgeaircon.com CHASSIS CODE: B3/B4 Ceiling Concealed Duct (Built in) ARNU07GB3G2+PBSGB30(Acc'y), PBSC30(Acc'y) ARNU09GB3G2+ ...

  • Haier R410A - page 63

    - 63 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 1. Funtions ......................................................................................64 2. Operation Details ........................................................................65 3. Dimensions ............. ...

  • Haier R410A - page 64

    Funtion - 64 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 1. Funtions Indoor Unit Operation ON/OFF by Remote controller Sensing the Room Temperature Room temperature control Starting Current Control Indoor Fan Speed Control Soft Dry Operation Mode Deice (defrost) control (H ...

  • Haier R410A - page 65

    Operation Details - 65 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only Intake Air Temperature SET TEMPERATURE +0.5 ° C (Thermo. ON) SET TEMPERATURE -0.5 ° C (Thermo. OFF) More than More than 3 minutes 3 minutes Selecting Selecting Selecting fan speed fan speed fan speed COMP ...

  • Haier R410A - page 66

    Operation Details - 66 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only ■ Heating Mode Operation The unit will operate according to the setting by the remote controller and the operation diagram is shown as following. Thermal Outdoor fan Indoor fan 4way valve Setting Temperat ...

  • Haier R410A - page 67

    Operation Details - 67 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only ■ Hot-Star t Contr ol • The indoor fan does not rotate until the indoor unit Hex-Exchanger temperature reaches 22 ° C. • The operation diagram is as following. ON ON Off Off Low Low 1 min Hotstart On ...

  • Haier R410A - page 68

    Dimensions - 68 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 3. Dimensions 76, Seongsan-dong, Changwon City , Gyeongnam, 641-713, K orea www .lgeaircon.com CHASSIS CODE: BH Ceiling Concealed Duct (High Static) ARNU07GBHA2 ARNU09GBHA2 ARNU12GBHA2 ARNU15GBHA2 ARNU18GBHA2 ARNU ...

  • Haier R410A - page 69

    Dimensions - 69 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 76, Seongsan-dong, Changwon City , Gyeongnam, 641-713, K orea www .lgeaircon.com CHASSIS CODE: BG Ceiling Concealed Duct (High Static) ARNU28GBGA2 ARNU36GBGA2 ARNU42GBGA2 Note 1. Unit should be installed in compli ...

  • Haier R410A - page 70

    Dimensions - 70 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 76, Seongsan-dong, Changwon City , Gyeongnam, 641-713, K orea www .lgeaircon.com CHASSIS CODE: BR Ceiling Concealed Duct (High Static) ARNU48GBRA2 Note 1. Unit should be installed in compliance with the installati ...

  • Haier R410A - page 71

    Dimensions - 71 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 76, Seongsan-dong, Changwon City , Gyeongnam, 641-713, K orea www .lgeaircon.com CHASSIS CODE: B8 Ceiling Concealed Duct (High Static) URNU76GB8A2 URNU96GB8A2 Note 1. Unit should be installed in compliance with th ...

  • Haier R410A - page 72

    - 72 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 1. Functions ....................................................................................73 2. Operation Details ........................................................................74 3. Dimensions .............. ...

  • Haier R410A - page 73

    - 73 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only Functions 1. Functions • Room temperature sensor. (THERMISTOR) • Maintains the room temperature in accordance with the Setting temperature • Indoor fan is delayed for 5 sec at the starting. • High, Med, Low, CHAOS ? ...

  • Haier R410A - page 74

    Operation Details - 74 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 2. Operation Details DISPLA Y (1) High quality LCD remote controller supplied Operation Indicator • On while in appliance operation, off while in appliance pause Timer(on/off) and Sleep timer Indicator ? ...

  • Haier R410A - page 75

    Operation Details - 75 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only ■ Healthy Dehumidification Mode • When the dehumidification operation input by the remote controller is received, the intake air temperature is detected and the setting temp is automatically set accordi ...

  • Haier R410A - page 76

    Operation Details - 76 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 26 ° C ≤ Intake Air Temp => 25 ° C 24 ° C ≤ Intake Air Temp<26 ° C => Intake Air Temp+1 ° C 22 ° C ≤ Intake Air Temp<24 ° C => Intake Air Temp+0.5 ° C 18 ° C ≤ Intake Air Tem ...

  • Haier R410A - page 77

    Operation Details - 77 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only • At the beginning of Fuzzy mode operation, the setting temperature is automatically selected according to the intake air temp at that time. 26 ° C ≤ Intake Air Temp => 25 ° C 24 ° C ≤ Intake Ai ...

  • Haier R410A - page 78

    Operation Details - 78 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only ■ Off-Timer <=> On-Timer Operation • When the set time is reached after the on/off time is input by the remote controller, the on/off-timer operation is carried out according to the set time. ■ ...

  • Haier R410A - page 79

    Operation Details - 79 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only - Operation Mode/Setting Temp/Selected Airflow Speed - Sleep Timer Mode/Remaining Time of Sleep Timer (unit of hour) ■ Forced Operation • Operation procedures when the remote control can't be used. ...

  • Haier R410A - page 80

    Operation Details - 80 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only ■ Air Cleaner Operation • When an air cleaner function is selected during Air Conditioner operation - Plasma air cleaner function will be operated while in any operation mode with selecting the function ...

  • Haier R410A - page 81

    Dimensions - 81 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 3. Dimensions 76, Seongsan-dong, Changwon City , Gyeongnam, 641-713, K orea www .lgeaircon.com CHASSIS CODE: SE W all Mounted ARNU07GSE*2 ARNU09GSE*2 ARNU12GSE*2 ARNU15GSE*2 W Model ARNU07GSE*2 ARNU09GSE*2 ARNU12G ...

  • Haier R410A - page 82

    Dimensions - 82 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 76, Seongsan-dong, Changwon City , Gyeongnam, 641-713, K orea www .lgeaircon.com CHASSIS CODE: S5 W all Mounted ARNU18GS5*2 ARNU24GS5*2 W Model ARNU18GS5*2 ARNU24GS5*2 HD 1090 300 178 Note 1. Unit should be instal ...

  • Haier R410A - page 83

    - 83 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 1. Funtions ......................................................................................84 2. Operation Details ........................................................................85 3. Dimensions ............. ...

  • Haier R410A - page 84

    - 84 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 1. Function Indoor Unit Operation ON/OFF by Remote controller Sensing the Room Temperature Room temperature control Starting Current Control Indoor Fan Speed Control Soft Dry Operation Mode Deice (defrost) control (Heating) ...

  • Haier R410A - page 85

    - 85 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 2. Operation Details Operation Details ■ Soft-Dry Operation • The indoor fan speed is automatically set to the low, so the shift of the indoor fan speed is impossible because of already being set to the best speed for Dr ...

  • Haier R410A - page 86

    - 86 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only Operation Details ■ Heating Mode Operation The unit will operate according to the setting by the remote controller and the operation diagram is shown as following. Thermal Outdoor fan Indoor fan 4way valve Setting Temperat ...

  • Haier R410A - page 87

    - 87 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only Operation Details ■ Hot-Star t Contr ol • The indoor fan does not rotate until the indoor unit Hex-Exchanger temperature reaches 30 ° C. • The operation diagram is as following. ON ON Off Off Low Low 1 min Hotstart On ...

  • Haier R410A - page 88

    - 88 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 3. Dimensions Dimensions 76, Seongsan-dong, Changwon City , Gyeongnam, 641-713, K orea www .lgeaircon.com CHASSIS CODE: VE Ceiling & Floor ARNU09GVEA2 ARNU12GVEA2 Note 1. Unit should be installed in compliance with the i ...

  • Haier R410A - page 89

    - 89 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only Dimensions 76, Seongsan-dong, Changwon City , Gyeongnam, 641-713, K orea www .lgeaircon.com CHASSIS CODE: VJ Ceiling Suspended ARNU18GVJA2 ARNU24GVJA2 Note 1. Unit should be installed in compliance with the installation manu ...

  • Haier R410A - page 90

    - 90 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 1. Function ......................................................................................91 2. Operation Details ........................................................................92 3. Dimensions ............. ...

  • Haier R410A - page 91

    - 91 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 1. Function Indoor Unit Operation ON/OFF by Remote controller Sensing the Room Temperature Room temperature control Starting Current Control Indoor Fan Speed Control Soft Dry Operation Mode Deice (defrost) control (Heating) ...

  • Haier R410A - page 92

    Operation Details - 92 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 2. Operation Details ■ Soft-Dry Operation • The indoor fan speed is automatically set to the low, so the shift of the indoor fan speed is impossible because of already being set to the best speed for Dr ...

  • Haier R410A - page 93

    Operation Details - 93 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only ■ Heating Mode Operation The unit will operate according to the setting by the remote controller and the operation diagram is shown as following. Thermal Outdoor fan Indoor fan 4way valve Setting Temperat ...

  • Haier R410A - page 94

    Operation Details - 94 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only ■ Hot-Star t Contr ol • The indoor fan does not rotate until the indoor unit Hex-Exchanger temperature reaches 30 ° C. • The operation diagram is as following. ON ON Off Off Low Low 1 min Hotstart On ...

  • Haier R410A - page 95

    - 95 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only Dimensions 3. Dimensions 76, Seongsan-dong, Changwon City , Gyeongnam, 641-713, K orea www .lgeaircon.com CHASSIS CODE: CE Floor Standing ARNU07GCEA2 ARNU09GCEA2 ARNU12GCEA2 ARNU15GCEA2 ARNU07GCEU2 ARNU09GCEU2 ARNU12GCEU2 AR ...

  • Haier R410A - page 96

    - 96 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only Dimensions 76, Seongsan-dong, Changwon City , Gyeongnam, 641-713, K orea www .lgeaircon.com CHASSIS CODE: CF Floor Standing ARNU18GCF A2 ARNU24GCF A2 ARNU18GCFU2 ARNU24GCFU2 Note 1. Unit should be installed in compliance wit ...

  • Haier R410A - page 97

    - 97 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only Pa r t 3 T r ouble shooting guide ...

  • Haier R410A - page 98

    - 98 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only Self-diagnosis function .....................................................................99 T r ouble shooting guide ...

  • Haier R410A - page 99

    - 99 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only Self-diagnosis function Self-diagnosis function Self-Diagnosis Function Error Indicator • This function indicates types of failure in self-diagnosis and occurrence of failure for air condition. • Error mark is displayed ...

  • Haier R410A - page 100

    Self-diagnosis function - 100 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 01 Indoor unit air sensor error 02 Indoor unit pipe inlet sensor error 06 Indoor unit pipe outlet sensor error Error No. Error Type Error Point Main Reasons Indoor unit sensor is open/short 1. Indoor ...

  • Haier R410A - page 101

    Self-diagnosis function - 101 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only * If there is no remote controller to replace : Use another unit ’ s remote controller doing well ** Check cable : Contact failure of connected portion or extension of cable are main cause Check an ...

  • Haier R410A - page 102

    Self-diagnosis function - 102 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 1. Drain pump/float switch fault 04 Drain pump error 2. Improper drain pipe location, clog- ging of drain pipe 3. Indoor unit PCB fault Error No. Error Type Error Point Main Reasons ■ Error dia gno ...

  • Haier R410A - page 103

    Self-diagnosis function - 103 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only *** Indoor PCB drain pump connector (Check input of 220V) (Marked as CN-DPUMP) float A:Point to check rotating Float switch Housing ( CN-FLOAT ) Float switch connector [***] Standard of drain pipe he ...

  • Haier R410A - page 104

    Self-diagnosis function - 104 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 1. Auto addressing is not done 2. transmission cable is not connected 3. Short circuit of transmission cable 4. Indoor unit transmission circuit fault 05 5. Outdoor unit transmission circuit fault 6. ...

  • Haier R410A - page 105

    Self-diagnosis function - 105 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 06 Refer to CH02 Error No. Error Type Error Point Main Reasons Indoor unit outlet pipe temperature sensor open or short Indoor unit outlet pipe temperature sensor error 07 1. Indoor units are in diff ...

  • Haier R410A - page 106

    Self-diagnosis function - 106 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 09 1. Error developed in transmission between the micro- processor and the EEPROM on the sur- face of the PCB. 2. ERROR due to the EEPROM damage Error No. Error Type Error Point Main Reasons Indoor u ...

  • Haier R410A - page 107

    Self-diagnosis function - 107 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 10 Indoor unit BLDC fan motor failure Error No. Error Type Error Point Main Reasons Indoor BLDC fan motor feedback signal is absent (for 50 sec.) 1. Motor connector connection fault 2. Indoor PCB fau ...

  • Haier R410A - page 108

    Self-diagnosis function - 108 - Copyright ©2008 LG Electronics. Inc. All right reserved. Only for training and service purposes LGE Internal Use Only 11 Indoor unit transmission error Error No. Error Type Error Point Main Reasons Indoor unit doesn ’ t get sig- nal from ODU for 3 minutes continuously 1. Indoor 485 transmission PCB fault 2. After ...

  • Haier R410A - page 109

    P/NO : MFL50459501 APRIL, 2008 ...

Produzent Haier Kategorie Air Conditioner

Dokumente, die wir vom Produzenten des Geräts Haier R410A erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Haier
- Bedienungsanleitungen R410A
- Produktkarten Haier
- Informationsbroschüren
- oder Energieetiketten Haier R410A
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Haier R410A.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Haier R410A, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Haier R410A. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Haier R410A ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Haier R410A, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Haier R410A hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Haier R410A verständlich ist.

Eine gänzliche Bedienungsanleitung von Haier sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Haier R410A bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Haier R410A befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Haier R410A, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Haier R410A - die uns die ersten Schritte während der Nutzung von Haier R410A erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Haier R410A hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Haier R410A im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Haier R410A?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Haier R410A nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Haier R410A hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)