  • Kohler 12RESM1 - page 1

    Residential/Commercial Generator Sets Models: 12RESM1 12/17/18RESL 12/17/18RESNT 12/18RESHD Controller: DC-RET Digital Control TP-6516 4/09d Installation ...

  • Kohler 12RESM1 - page 2

    Engine exhaust from this product contains chemicals known to the State of California to cause cancer , birth defects, or other reproductive harm. W ARNING California Proposition 65 Product Identification Information Generator Set Ident ification Numbers Record the product identification numbers from the generator set nameplate(s). Model Designation ...

  • Kohler 12RESM1 - page 3

    T able of Contents TP-6516 4/09 T able of Contents 3 Product Identification Information 2 .......................................................... Safety Precautions and Instructions 5 ........................................................ Introduction 9 ............................................................................... Service Ass ...

  • Kohler 12RESM1 - page 4

    TP-6516 4/09 4 Notes ...

  • Kohler 12RESM1 - page 5

    TP-6516 4/09 5 Safet y Precautions and Instruct ions Safety Precautions and Instructions IMPORT ANT SAFETY INSTRUCTIONS. Electromechanical equipment, including generator sets, transfer switches, switchgear , and accessories, can cause bodily harm and pose life-threatening danger when improperly installed, operated, or maintained. T o prevent accide ...

  • Kohler 12RESM1 - page 6

    TP-6516 4/09 6 Safet y Precautions and Instruct ions Battery gases. Explosion can cause severe injury or death. Battery gases can cause an explosion. Do not smoke or permit flames or sparks to occur near a battery at any time, particularly when it is charging. Do not dispose of a battery in a fire. T o prevent burns and sparks that could cause an e ...

  • Kohler 12RESM1 - page 7

    TP-6516 4/09 7 Safet y Precautions and Instruct ions Hazardous Noise Hazardous noise. Can cause hearing loss. Never operate the generator set without a muffler or with a faulty exhaust system. CAUTION Engine noise. Hazardous noise can cause hearing loss. Generator sets not equipped with sound enclosures can produce noise levels greater than 105 dBA ...

  • Kohler 12RESM1 - page 8

    TP-6516 4/09 8 Safet y Precautions and Instruct ions Hot Parts Hot engine and exhaust system. Can cause severe injury or death. Do not work on the generator set until it cools. W ARNING Servicing the exhaust system. Hot parts can cause severe injury or death. Do not touch hot engine parts. The engine and exhaust system components become extremely h ...

  • Kohler 12RESM1 - page 9

    TP-6516 4/09 9 Introduction This manual provides installation instructions for 12, 17, and 18 kW residential/commercial generator sets equipped with the Kohler r DC-RET Digital Control. Refer to TP-6517, Operation Manual, for generator set operation and maintenance instructions. The generator set is approved for use in stationary applications in lo ...

  • Kohler 12RESM1 - page 10

    TP-6516 4/09 10 12 5 42 0 16 6 3 13 24 17 19 14 15 22 ADV-7341A-B 10 25 23 9 21 18 Control detail, top view 8 11 7 12 1. Muf fler 2. Oil check 3. Oil fill 4. Air cleaner 5. Spark plug locations (bot h sides) 6. Oil filter 7. Oil cooler location 8. DC-RET Digital Cont rol display 9. Generator set m aster switch (RUN-OFF/R ESET - AUTO) 10. Line circu ...

  • Kohler 12RESM1 - page 11

    TP-6516 4/09 11 Service Assistance For professional advice on generator set power requirements and conscientious service, please contact your nearest Kohler distributor or dealer . D Consult the Y ellow Pages under the heading Generators—Electric. D Visit the Kohler Power Systems website at KohlerPower .com. D Look at the labels and stickers on y ...

  • Kohler 12RESM1 - page 12

    TP-6516 4/09 12 Notes ...

  • Kohler 12RESM1 - page 13

    TP-6516 4/09 13 Section 1 I nstallation Section 1 Installation 1.1 General Have an authorized distributor/dealer install the generator set outdoors according to the instructions in this manual. The generator set installation must comply with the National Electrical Code (NEC) and local code requirements. Do not install this generator set indoors. U ...

  • Kohler 12RESM1 - page 14

    TP-6516 4/09 14 Section 1 Inst allation Note: Fuel system may differ from drawing. See Section 1.7. Figure 1-2 Generator Set Mounting Details and Dimensions, 12 kW Models, ADV -7466, Sheet 1 ...

  • Kohler 12RESM1 - page 15

    TP-6516 4/09 15 Section 1 I nstallation Figure 1-3 Generator Set Clearances, 12 kW Models, ADV -7466, Sheet 2 ...

  • Kohler 12RESM1 - page 16

    TP-6516 4/09 16 Section 1 Inst allation Figure 1-4 Generator Set Mounting Details and Dimensions, 17/18 kW Models, ADV -7341-B, Sheet 1 ...

  • Kohler 12RESM1 - page 17

    TP-6516 4/09 17 Section 1 I nstallation Figure 1-5 Generator Set Clearances, 17/18 kW Models, ADV -7341-B, Sheet 2 ...

  • Kohler 12RESM1 - page 18

    TP-6516 4/09 18 Section 1 Inst allation 1.4.1 Exhaust Requirements Carbon monoxide. Can cause severe nausea, fainting, or death. The exhaust system must be leakproof and routinely inspected. W ARNING Generator set operation. Carbon monoxide can cause severe nausea, fainting, or death. Carbon monoxide is an odorless, colorless, tasteless, nonirritat ...

  • Kohler 12RESM1 - page 19

    TP-6516 4/09 19 Section 1 I nstallation 1.6 Fuel Requirements The generator set operates using natural gas or LP vapor fuel. The generator set is EP A-certified for both natural gas and LP vapor fuels. The fuel system installation must comply with the NEC and local codes. 1.6.1 Fuel Supply Because of variable climates and geographical consideration ...

  • Kohler 12RESM1 - page 20

    TP-6516 4/09 20 Section 1 Inst allation 1.6.2 Fuel Pipe Size Ensure that the natural gas pipe size and length meet the specifications in Figure 1-13 or Figure 1-14. Measure the pipe length from the primary gas pressure regulator to the pipe connection on the generator set fuel inlet. Add 2.4 m (8 ft.) to the measured length for each 90 degree elbow ...

  • Kohler 12RESM1 - page 21

    TP-6516 4/09 21 Section 1 I nstallation Procedure to Convert from NG to LP 1. Place the generator set master switch in the OFF position. 2. Disconnect the power to the battery charger . 3. Disconnect the generator set engine starting battery , negative ( - - ) lead first. 4. T urn off the fuel supply . 5. Remove the hose clamp and fuel hose from th ...

  • Kohler 12RESM1 - page 22

    TP-6516 4/09 22 Section 1 Inst allation 9. Connect and turn on the new fuel supply . 10. Check that the generator set master switch is in the OFF position. 1 1. Reconnect the generator set engine starting battery leads, negative ( - -) lead last. 12. Reconnect power to the battery charger . 13. Start the generator set by moving the generator set ma ...

  • Kohler 12RESM1 - page 23

    TP-6516 4/09 23 Section 1 I nstallation 1. Junction box 2. Field connection term inal block location (see Figure 1-20) 3. Suggested elect rical inlet ADV-7341 2 1 3 12 kW 17/18 kW ADV-7466 1 2 3 Figure 1-19 Field Wiring Figure 1-20 Field-Connection T erminal Block 1.8.2 Remote Start Connection Connect engine start leads from terminals 3 and 4 to th ...

  • Kohler 12RESM1 - page 24

    TP-6516 4/09 24 Section 1 Inst allation 1.9 Battery Sulfuric acid in batteries. Can cause severe injury or death. Wear protective goggles and clothing. Battery acid may cause blindness and burn skin. W ARNING Explosion. Can cause severe injury or death. Relays in the battery charger cause arcs or sparks. Locate the battery in a well-ventilated area ...

  • Kohler 12RESM1 - page 25

    TP-6516 4/09 25 Section 1 I nstallation Note: The generator set will not start and circuit board damage may occur if the battery is connected in reverse. Figure 1-22 shows the location of the engine starting battery . Standard battery cables provide easy connection to the battery . Use the following procedure to install and connect the battery . AD ...

  • Kohler 12RESM1 - page 26

    TP-6516 4/09 26 Section 1 Inst allation 1.10 Carburetor Heater (optional) Have accessories installed by an authorized distributor/ dealer or a licensed electrician. F ollow the installation instructions provided with each kit. U se s eparate conduit for AC and DC leads to reduce the possibility of electrical interference. V erify that the leads and ...

  • Kohler 12RESM1 - page 27

    TP-6516 4/09 27 Section 1 I nstallation GM19463 1 1. Thermostat 2. Connector 3. Heater 3 12 kW Carburetor Heater 1 3 17/18 kW Carburetor Heater GM57968 2 Figure 1-26 Carburetor Heaters 1.1 1 Prestart Installation Check Review the entire installation section. Inspect all wiring and connections to verify that the generator set is ready for operation. ...

  • Kohler 12RESM1 - page 28

    TP-6516 4/09 28 Section 1 Inst allation Notes ...

  • Kohler 12RESM1 - page 29

    TP-6516 4/09 29 Section 2 Wiring Diagram s Section 2 Wiring Diagrams Figure 2-1 lists the wiring diagram drawing numbers and drawing references. Wiring Diagram Description Drawing Number Reference Page Schematic Diagram, 12 kW Models ADV -7351 Figure 2-2 30 Point-to-Point Wiring Diagram, 12 kW Models GM52471 Figure 2-3 31 Schematic Diagram, 17/18 k ...

  • Kohler 12RESM1 - page 30

    TP-6516 4/09 30 Section 2 Wiring Diagrams - Figure 2-2 Schematic Diagram, 12 kW Models, ADV -7351 ...

  • Kohler 12RESM1 - page 31

    TP-6516 4/09 31 Section 2 Wiring Diagram s - Figure 2-3 Point-to-Point Wiring Diagram, 12 kW Models, GM52471 ...

  • Kohler 12RESM1 - page 32

    TP-6516 4/09 32 Section 2 Wiring Diagrams - Figure 2-4 Schematic Diagram, Single Phase, 17/18 kW Models, ADV -7353 ...

  • Kohler 12RESM1 - page 33

    TP-6516 4/09 33 Section 2 Wiring Diagram s Figure 2-5 Point-to-Point Wiring Diagram, Single Phase, 17/18 kW Models, GM52541 ...

  • Kohler 12RESM1 - page 34

    TP-6516 4/09 34 Section 2 Wiring Diagrams Notes ...

  • Kohler 12RESM1 - page 35

    TP-6516 4/09 Appendix 35 Appendix A Abbreviations The following list contains abbreviations that may appear in this publication. A, amp ampere ABDC aft er bottom dead center AC alternating current A/D analog to digital ADC advanced digital control; analog to digital convert er adj. adjust, adjustm ent ADV advertising dimensional drawing Ah amp-hour ...

  • Kohler 12RESM1 - page 36

    TP-6516 4/09 36 Appendix k kilo (1000) K kelvin kA kiloampere KB kilobyte (2 10 bytes) KBus Kohler comm unication protocol kg kilogram kg/cm 2 kilogram s per square centimet er kgm kilogram-met er kg/m 3 kilogram s per cubic meter kHz kilohertz kJ kilojoule km ki lome ter kOhm, k Ω kilo-ohm kPa kilopascal kph kilometers per hour kV kilovolt kV A ...

  • Kohler 12RESM1 - page 37

    TP-6516 4/09 37 Notes ...

  • Kohler 12RESM1 - page 38

    TP-6516 4/09 38 Notes ...

  • Kohler 12RESM1 - page 39

    ...

  • Kohler 12RESM1 - page 40

    E 2007, 2008, 2009 by Kohler Co. A ll rights reserved. TP-6516 4/09d KOHLER CO. Kohler , Wisconsin 53044 Phone 920-565-3381, Fax 920-459-1646 For the nearest sales/service outlet in the US and Canada, phone 1-800-544-2444 KohlerPower .com Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65) 6264-6422, Fax (6 ...

Produzent Kohler Kategorie Portable Generator

Dokumente, die wir vom Produzenten des Geräts Kohler 12RESM1 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Kohler
- Bedienungsanleitungen 12RESM1
- Produktkarten Kohler
- Informationsbroschüren
- oder Energieetiketten Kohler 12RESM1
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Kohler 12RESM1.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Kohler 12RESM1, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Kohler 12RESM1. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Kohler 12RESM1 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Kohler 12RESM1, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Kohler 12RESM1 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Kohler 12RESM1 verständlich ist.

Eine gänzliche Bedienungsanleitung von Kohler sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Kohler 12RESM1 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Kohler 12RESM1 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Kohler 12RESM1, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Kohler 12RESM1 - die uns die ersten Schritte während der Nutzung von Kohler 12RESM1 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Kohler 12RESM1 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Kohler 12RESM1 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Kohler 12RESM1?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Kohler 12RESM1 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Kohler 12RESM1 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)