    291627-YTG-B-0807 FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE TECHNICAL GUIDE AFFINITY™ SERIES SINGLE P ACKAGE GAS/ELEC TRIC AIR COOLED AIR CONDITIONERS 2-1/2 THROUGH 5 NOMINAL TON DNH030 THROUGH 060 UP TO 12.4 SEER ® FLEXIBLE LIGHT CO MMERCIAL UNIT GENERAL York ® Affinity™ Series packaged units are designed to han- dle ...

  • York 291627-YTG-B-0807 - page 2

    291627-YTG-B-0807 2 Unitary Products Group T ABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 STANDARD FEATURES/BENEFITS . . . . . . . . . . . . 3 FIELD-INSTALLED ACCESSORIES . . . . . . . . . . . . . 4 TYPICAL WIRING DI AGRAM NOTES . . . . . . . . . . 28 MECHANICAL SPECIFICATIONS . . . . . . . . . . . . . ...

  • York 291627-YTG-B-0807 - page 3

    291627-YTG-B-0807 Unitary Products Group 3 DESCRIPTION These packaged cooling/heating ai r conditioners are designed for outdoor i nstallation. Only utility and duct con- nections are required at the point of installation . The gas-fired heaters have al umin ized steel tubu lar heat exchangers and spark to pilot ignition . They are available in nat ...

  • York 291627-YTG-B-0807 - page 4

    291627-YTG-B-0807 4 Unitary Products Group FAN SYSTEM - All models operate over a wide range of design conditions with a 3-spee d direct-drive fan motor. These units easily match all ty pes of applications and pro- vides greater o n site flexibili ty to match comfort requirement. SIMPLE CONTROL CIRCUIT - A low voltage p rinted circuit board contain ...

  • York 291627-YTG-B-0807 - page 5

    291627-YTG-B-0807 Unitary Products Group 5 ANTI SHORT CYCLE TIMER - Automatically prevents the compressor from restarting for 5 minutes after cycled off.Not required if Thermostat 2E T07700224 a nd 2ET0470022 4 are used. MOTORIZED FRESH AIR DAMPER - Designed for duct mounted side supply/return and unit mounted down supply/ return applications. Damp ...

  • York 291627-YTG-B-0807 - page 6

    291627-YTG-B-0807 6 Unitary Products Group T A BLE 1: PHYSICAL DA T A MODEL DN H 030 036 042 048 060 EV APORA TOR BLOWER CENTRIFUGAL BLOWER (Dia. x W . in.) 10 X 8 1 1 x 10 1 1 x 10 12 x 1 1 12 x 11 F AN MOTOR HP (3 S peed) 1/2 3/4 3/4 3/4 1 EV APORA TOR COIL ROWS DEEP 3 3 3 3 3 FINS PER INCH 13 13 13 16 16 F ACE AREA (Sq. Ft.) 3.5 3.5 4. 5 4.5 4. ...

  • York 291627-YTG-B-0807 - page 7

    291627-YTG-B-0807 Unitary Products Group 7 T A BLE 2: RA TINGS COOLI NG/GAS HEA TING MODEL DNH NET COOLING CAP ACITY 1 SOUND RA TING (dbels) 2 GAS HEA T CAP ACITY / EFFICIENCIES MBH SEER 3 INPUT (MBH) OUTPUT (MBH) AFUE 4 (%) NUMBER OF BURNERS TEMP . RISE (°F) RANGE 030N03625 28.0 12.0 80 45 36 80.2 2 25 - 55 030N03646 28.0 12.0 80 45 36 80.2 2 25 ...

  • York 291627-YTG-B-0807 - page 8

    291627-YTG-B-0807 8 Unitary Products Group T A BLE 3: DNH030 COOLING CAP ACITIES - 2-1/2 TON TEMPERA TURE OF AIR ON CONDENSER COIL AIR ON EV APORA TOR COIL 750 CFM 875 CFM 1,000 CFM 1,125 CFM 1,250 CFM WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 62 57 72 67 6 2 57 72 67 62 57 72 67 62 5 7 85 °F NET CAP . MBH 27.2 26.8 24.1 24.0 28.5 28.1 ...

  • York 291627-YTG-B-0807 - page 9

    291627-YTG-B-0807 Unitary Products Group 9 T A BLE 4: DNH036 COOLING CAP ACITIES - 3 TON TEMPERA TURE OF AIR ON CONDENSER COIL AIR ON EV APORA TOR COIL 900 CFM 1,050 CFM 1,200 CFM 1,300 CFM 1,400 CFM WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 85 °F NET CAP . MBH 35.9 33.6 31 .7 31.6 38.4 35.9 33. ...

  • York 291627-YTG-B-0807 - page 10

    291627-YTG-B-0807 10 Unitary Products Group T A BLE 5: DNH042 COOLING CAP ACITIES - 3-1/2 TON TEMPERA TURE OF AIR ON CONDENSER COIL AIR ON EV APOR A TOR COIL 1,050 CFM 1,225 CFM 1,400 CFM 1,575 CFM 1,750 CFM WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 6 2 57 85 °F NET CAP . MBH 38.6 38.4 34.0 33.3 42.1 ...

  • York 291627-YTG-B-0807 - page 11

    291627-YTG-B-0807 Unitary Products Group 11 T A BLE 6: DNH048 COOLING CAP ACITIES - 4 TON TEMPERA TURE OF AIR ON CONDENSER COIL AIR ON EV APORA T OR COIL 1,200 CFM 1,400 CFM 1,600 CFM 1,800 CFM 2,000 CFM WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 85 °F NET CAP . MBH 50.8 47.4 43.1 42.8 52.8 49.3 ...

  • York 291627-YTG-B-0807 - page 12

    291627-YTG-B-0807 12 Unitary Products Group T A BLE 7: DNH060 COOLING CAP ACITIES - 5 TON TEMPERA TURE OF AIR ON CONDENSER COIL AIR ON EV APORA TOR COIL 1,700 CFM 1,800 CFM 1,900 CFM 2,000 CFM 2,100 CFM WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 85 °F NET CAP . MBH 66.8 63.1 58.2 57.0 68. 2 64.4 ...

  • York 291627-YTG-B-0807 - page 13

    291627-YTG-B-0807 Unitary Products Group 13 T A BLE 8: SIDE SUPPL Y AIR BL OWER PERFORMANCE - 208 VOL T 1 MODEL # DNH (Cooling/ Heating) MTR SPD EXTERNAL ST AIC PRESSURE - IWG .10 .20 .30 .40 .50 .6 0 .70 .80 .90 1.00 1.10 CFM WATT S CFM WATT S CFM WATT S CFM WATT S CFM WATT S CFM WATT S CFM WATT S CFM WATT S CFM WATT S CFM WATT S CFM WATT S 030 H ...

  • York 291627-YTG-B-0807 - page 14

    291627-YTG-B-0807 14 Unitary Products Group T A BLE 9: SIDE SUPPL Y AIR BLOWER PERFORMANCE - 230 & 460 VOL T 1 MODEL # DNH (Cooling/ Heating) MTR SPD EXTERNAL ST A TIC PRESSURE - IWG .10 .20 .30 .40 .50 .60 .7 0 .80 .90 1.00 1.10 CFM W A TTS CFM W A TTS CFM W A TTS CFM W A TTS CFM W A TTS CFM W A TTS CFM W A TTS CFM W A TTS CFM W A TTS CFM W A ...

  • York 291627-YTG-B-0807 - page 15

    291627-YTG-B-0807 Unitary Products Group 15 T AB LE 10: BOTTOM SUPPL Y AIR BLOWER PERFORMANCE - 208 VOL T 1 MODEL # DNH (Cooling/ Heating) MTR SPD EXTERNAL ST A TIC PRESSURE - IWG .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 1 .10 CFM W A TTS CFM W A TTS CFM W A TTS CFM W A TTS CFM W A TTS CFM W A TTS CFM W A TTS CFM W A TTS CFM W A TTS CFM W A TTS CFM ...

  • York 291627-YTG-B-0807 - page 16

    291627-YTG-B-0807 16 Unitary Products Group T ABLE 1 1: BOTTOM SUPPL Y AIR BLOW ER PERFORMANCE - 230 & 460 VOL TS 1 MODEL # DNH (Cooling/ Heating) MTR SPD EXTERNAL ST A TIC PRESSURE - IWG .10 .20 .30 .40 .50 .60 .70 .80 .90 1.00 1.10 CFM W A TTS CFM W A TTS CFM W A TTS CFM W A TTS CFM W A TTS CFM W A TTS CFM W A TTS CFM W A TTS CFM W A TTS CFM ...

  • York 291627-YTG-B-0807 - page 17

    291627-YTG-B-0807 Unitary Products Group 17 FIGURE 3 - TYPICAL FIEL D CONTROL WIRING DIAGRAM FIGURE 4 - TYPICAL FIEL D POWER WIRING DIAGRAM T A BLE 13: ADDITIONAL ST A TIC PRESSURE RESIST ANCE 3-1/2 - 5 TON (DNH042 - 060) 1 DESCRIPTION RESIST ANCE, IWG CFM 1,100 1,200 1,300 1, 400 1,500 1,600 1,700 1,80 0 1,900 2,000 WET EV APORA TOR COI L .02 .03 ...

  • York 291627-YTG-B-0807 - page 18

    291627-YTG-B-0807 18 Unitary Products Group T A BLE 14: ELECTRICAL DA T A MODEL DNH POWER SUPPL Y VOL T AGE LIMIT A TIONS 1 COMPR ESSOR COND. FA N MOTOR, FLA SUPPL Y AIR BLOWER MOT OR FLA MINIMUM CIRCUIT AMP A CITY MAX. FUSE SIZE, AMPS 2 MAX. HACR BREAKE R SIZE, AMPS UNIT POWER FA C T O R TRANSFORMER SIZE (V A) MIN. MAX. RLA LRA 030 208/230-3-60 18 ...

  • York 291627-YTG-B-0807 - page 19

    291627-YTG-B-0807 Unitary Products Group 19 FIGURE 5 - UNIT DIMENSI ONS - FRONT All dimensions are in inches. They are subject to change with- out notice. Certified dimensions will be provided upon request. T A BLE 15: UNIT DIMENSIONS FRONT UNIT SIZE DIMENSION “A” “B” 030 - 036 33-1/2 18-1/4 042 - 060 41-1/2 23-1/8 T A BLE 16: UNIT MINIMUM ...

  • York 291627-YTG-B-0807 - page 20

    291627-YTG-B-0807 20 Unitary Products Group FIGURE 6 - UNIT DIMENSIONS - FRONT & BO TTOM FIGURE 7 - UNIT DIMENSIONS - BACK & BOTTOM 2 6 - 3 / 4 6 4 - 5 / 8 8 - 7 / 8 1 1 - 7 / 8 1 9 - 1 / 4 H I G H V O L T A G E C O N N . 1 - 3 / 3 2 " D I A . K N O C K O U T F R O N T C O N D E N S A T E D R A I N 3 / 4 " ' N P T I G A S S U ...

  • York 291627-YTG-B-0807 - page 21

    291627-YTG-B-0807 Unitary Products Group 21 FIGURE 8 - TYPICAL SLAB O N GROUND INST ALLA TION FIGURE 9 - TYPICAL ROOF CURB INST ALLA TION F I E L D S U P P L I E D D I S C O N N E C T S W I T C H L O C A T E D T O R E A R O F U N I T T O G A S S U P P L Y L I N E M A N U A L G A S S H U T - O F F V A L V E R E T U R N A I R D U C T SU PPL Y AI R D ...

  • York 291627-YTG-B-0807 - page 22

    291627-YTG-B-0807 22 Unitary Products Group FIGURE 10 - TYPICAL DUCT APPLI CA T IONS FIGURE 1 1 - UNIT CENTER OF GRA VITY R O O F C U R B I N S T A L L A T I O N R E A R D U C T R O O F C U R B I N S T A L L A T I O N B O T T O M D U C T S L A B O N G R O U N D I N S T A L L A T I O N T A BLE 17: UNIT WEIGHTS AND CENTER OF GRA V ITY UNIT SIZE SHIPP ...

  • York 291627-YTG-B-0807 - page 23

    291627-YTG-B-0807 Unitary Products Group 23 FIGURE 12 - ROOF CURB DIME NSIONS 1 FIGURE 13 - ROOF CURB CR OSS SECTION O P E N I N G F O R R E T U R N A I R D U C T O P E N I N G F O R S U P P L Y A I R D U C T 1 4 3 - 1 / 2 1 7 - 5 / 8 4 0 - 3 / 4 4 2 - 2 / 3 4 5 - 1 / 8 4 3 - 1 / 4 1 7 - 1 / 4 2 2 1 R E C O M M E N D E D D U C T S I Z E 1 7 - 1 / 8 ...

  • York 291627-YTG-B-0807 - page 24

    291627-YTG-B-0807 24 Unitary Products Group FIGURE 14 - TYPICAL WIRING DIAGRAM DNH 03 0, 036, 042, 048 (208/230- 3-60 POWER SUPPL Y) ...

  • York 291627-YTG-B-0807 - page 25

    291627-YTG-B-0807 Unitary Products Group 25 FIGURE 15 - TYPICAL WIRING DIAGRAM DNH 03 0, 036, 042, 048 (460-3-60 POWER SUPPL Y) ...

  • York 291627-YTG-B-0807 - page 26

    291627-YTG-B-0807 26 Unitary Products Group FIGURE 16 - TYPICAL WIRING DIAGRAM DNH 060 (2 08-230-3-60 P OWER SUPPL Y) ...

  • York 291627-YTG-B-0807 - page 27

    291627-YTG-B-0807 Unitary Products Group 27 FIGURE 17 - TYPICAL WIRING DIAG RAM DNH 060 (460-3-60 POWER SUPPL Y) ...

  • York 291627-YTG-B-0807 - page 28

    291627-YTG-B-0807 28 Unitary Products Group TYPICAL WIRING DIAGRAM NOTES (SEE FIGURES 14 THRU 17) 1. All field wiring to be accomplished followin g city , local and/or national codes in effect at time of installation of this unit. 2. Caution: Label all wires prior to disconnection when ser- vicing controls. Wiring errors can cause improper and dang ...

  • York 291627-YTG-B-0807 - page 29

    291627-YTG-B-0807 Unitary Products Group 29 MECHANICAL SPECIFICA TIONS GENERAL Units shall be manufactured by York International Unitary Products Group in an ISO 9001 certified facility. YORK’s Affinity™ package units are designed to handle appli cati ons ranging from residential to light commercial and any in between. The Affinity™ is a unit ...

  • York 291627-YTG-B-0807 - page 30

    291627-YTG-B-0807 30 Unitary Products Group be totally enclosed with perman ently lubricated bearings an d internally protected again st overload conditions. REFRIGERANT COMPONENTS Compressors: a. Shall be fully hermetic type, direct drive, interna lly protected with internal hi gh-pre ssure relief and over temperature protection. The hermetic moto ...

  • York 291627-YTG-B-0807 - page 31

    291627-YTG-B-0807 Unitary Products Group 31 ...

  • York 291627-YTG-B-0807 - page 32

    Subject to change without notic e. Printed in U.S.A. 291627-YTG-B-0807 Copyright © 2007 by Unitary Products Group. All ri ghts reserved. Supersedes: 291627-YTG-A-0207 Unitary 5005 Norman Product s Y ork OK Group Drive 73069 ...

Produzent York Kategorie Air Conditioner

Dokumente, die wir vom Produzenten des Geräts York 291627-YTG-B-0807 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen York
- Bedienungsanleitungen 291627-YTG-B-0807
- Produktkarten York
- Informationsbroschüren
- oder Energieetiketten York 291627-YTG-B-0807
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung York 291627-YTG-B-0807.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen York 291627-YTG-B-0807, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen York 291627-YTG-B-0807. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts York 291627-YTG-B-0807 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts York 291627-YTG-B-0807, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von York 291627-YTG-B-0807 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von York 291627-YTG-B-0807 verständlich ist.

Eine gänzliche Bedienungsanleitung von York sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von York 291627-YTG-B-0807 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von York 291627-YTG-B-0807 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich York 291627-YTG-B-0807, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts York 291627-YTG-B-0807 - die uns die ersten Schritte während der Nutzung von York 291627-YTG-B-0807 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit York 291627-YTG-B-0807 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von York 291627-YTG-B-0807 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich York 291627-YTG-B-0807?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit York 291627-YTG-B-0807 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit York 291627-YTG-B-0807 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)