Bedienungsanleitung Kenmore POWER MISER 153.330401

28 Seiten 1.66 mb
Download

Zur Seite of 28

Summary
  • Kenmore POWER MISER 153.330401 - page 1

    Owners Manual FOR POTABLE WATER HEATING ONLY NOT SUITABLE FOR SPACE HEATING NOT FOR USE IN MOBILE HONES Model No. 153.330401 40 Gal. High Altitude 153.330451 40 Gal. 153.330501 50 Gal. High Altitude 153.330551 50 Gal. 153.330701 75 Gal. High Altitude 153.330751 75 Gal Caution: Read and Follow All Safety Rules and Operating Instructions Before First ...

  • Kenmore POWER MISER 153.330401 - page 2

    Safety Precautions • _W,.ARNING . Impro.per installation, adjustment , alteration, service or maintenance can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. Refer to this manu- I al for assistance or consult your local Sears Service [ Center for further information. AWARNING WATER HEATERS EQUIPPED FOR ONE TYPE GAS ONLY: This water heater ...

  • Kenmore POWER MISER 153.330401 - page 3

    ? Safety Precautions _,WARNING A gas water beater cannot operate properly without the correct amount of air for combustion. Do not install in a confined area such a closet, unless you provide air as shown in the "Facts to Consider About the Location" sec- tion. Never obstruct the flow of ventilation air. If you have any doubts or question ...

  • Kenmore POWER MISER 153.330401 - page 4

    Safety Precautions ._,WARNING I The water heater with draft hood installed must be prep. [ erly vented to a chimney which termm.ates outdoors. I Never operate the water heater unless it is vented to the outdoors and has adequate air supply.to avoid risks of improper operation, explosion or asphyxiation. AWARNING Minimum clearances between the water ...

  • Kenmore POWER MISER 153.330401 - page 5

    Table of Contents _c__oarety Precautions ............................................................................................................................................ 2_ Table of Contents ................................................................................................................................................ 5 ...

  • Kenmore POWER MISER 153.330401 - page 6

    Customer Responsibilities Thank You for purchasinga Sears water heater. Properly installed and maintained, it should give you years of trouble free service. If you should decide that you want the new water heater professionally installed by Sears call the local Sears Service Center or any Sears store. They will arrange for prompt, quality installat ...

  • Kenmore POWER MISER 153.330401 - page 7

    Materials and Basic Tools Needed Materials Needed To simplify the installation Sears has available the installation parts shown below. You may or may not need all of these materi- als, depending on your type of installation. i Water Heater Installation Kit VENT ELBOW _. WATER HEATER INSTAL- LATION KIT WITH FLEXI- f BLE CONNECTORS FOR 314" OR 1 ...

  • Kenmore POWER MISER 153.330401 - page 8

    ? Installation Instructions Removing the Old Water Heater Turn "OFF" the gas supply to the water heater. AWARNING o If the main gas line shutoff serving all _ appliances is used, also shut "OFF" the gas at each appliance. Leave all gas appliances shut "OFF" until the water heater installa- t on s comp ete. Turn water t ...

  • Kenmore POWER MISER 153.330401 - page 9

    Installation Instructions (cont'd) Facts to Consider About the Location You should carefully choose an indoor location for the new water heater, because the placement is a very important consid- eration for the safety of the occupants in the building and for the most economical use of the appliance. This water heater is not for use in mobile h ...

  • Kenmore POWER MISER 153.330401 - page 10

    Installation InStructions (cont'd) Combustion Air and Ventilation for Appliances Located in Unconfined Spaces Uncon_qned Space is a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour of the aggregate input rating of all appliances installed in that space. Rooms comuiunicatin_ directly with the space in which the appliance ...

  • Kenmore POWER MISER 153.330401 - page 11

    Installation Instructions (cont'd) Water Piping AWARNING HOTTERWATER CAN SCALD:. Water heaters am intended to produce hot water. Water _ to a temperaturewhich will sat_fy clothes washing, dish washing, andother sanitizing needs can scald and permanently injure you upon contact. Some peo-I pie are more likely to be permanently injured by hot wa ...

  • Kenmore POWER MISER 153.330401 - page 12

    Installation InstruCtions (cont'd) Temperature-Pressure Relief Valve A WARNING At the time of manufacturethis water heater was provided with a combination temperature-pressures relief valve certified by a nationallyrecognized testing laboratorythat maintains periodic mspec_on of production of listed equipment or mate- rials, as meeting the req ...

  • Kenmore POWER MISER 153.330401 - page 13

    Installation Instructions (cont'd) Filling the Water Heater ACAUTION I Never use this water heat_' unless it mcompletelyfilledwith I wa_. To _ont dam_e to the tank, the tank must be elk_ I with water. Water must flow from the hot water faucet before turning "ON" gas to the water hea_. For proper venting in certain installations, ...

  • Kenmore POWER MISER 153.330401 - page 14

    Installation Instructions (cont'd) Venting (cont'd) All vent gases must be completdy vented to the outdoors of the structure (dwelling). InstaU only the draft hood provided with the new water heater and no other draft hood. Vent pipes must be secured at each joint with sheet metal screws. TO CHIMNEY VENT PIPE INSTALLATION Gas Piping AWARN ...

  • Kenmore POWER MISER 153.330401 - page 15

    Installation Instructions (cont'd) AWARNING • The appliance and its individual shutoff valve must be discon- nected from the gas supply piplng system during any pressure testing of the gas system at test pressures in excess of pound per square inch (3.SkPa). .. • The appiiance must be isulated from the gas suppiy Ixl_ngsys- tem by dosing i ...

  • Kenmore POWER MISER 153.330401 - page 16

    Installation Instructions (cont'd) Installation Checklist BEFORE LIGHTING THE PILOT: Check the gas lines for leaks. a. Use a soapy water solution. DO NOT test for gas leaks usinga match or open flame. b. Brush the soapy water solution on all gas pipes, joints and fittings. c. Check for bubbling soap. This means you have a leak. Turn OFF _ gas ...

  • Kenmore POWER MISER 153.330401 - page 17

    Operating Instructions Lighting AWARNING BEFORE LIGHTING PROPANE (L.R) GAS WATER HEATERS: Propane (LR) gas is beevier than air. Should ti_re be a le_k in the system, the gas will settle near the ground. Basements, crawl spaces, skirted areas under mobile homes (even when ventilated), closets and areas below groundlevelwill serve as pockets for the ...

  • Kenmore POWER MISER 153.330401 - page 18

    Operating Instructions (cont'd) Lighting label on the water heater as it appears above the thermostat FOR YOUR SAFETY READ BEFORE LIGHTING A. B. WARNING If you do not follow these Instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. This appliance has a pilot which must be lighted by ha ...

  • Kenmore POWER MISER 153.330401 - page 19

    Operating Instructions (cont'd) Temperature Regulation Due to the nature of the typical gas water heater, the water tem- Foerature in certain situations may vary up to 30°F higher or wet at the point of use such as, bathtubs, showers, sink, etc. Turn the water temperature dial clockwise Lff'_) to decrease the temperature, or counterclock ...

  • Kenmore POWER MISER 153.330401 - page 20

    Service and Adjustment Tank (Sediment) Cleaning Sediment build-up on the tank bottom may create varying amounts of noise, and if left in the tank will cause premature tank failure. In some water areas, you may not be able to drain all sediment deposits by simply draining the tank. In these cases Mag Erad (part no. 23600) can be used to help remove ...

  • Kenmore POWER MISER 153.330401 - page 21

    Service and Adjustment (cont'd) Draining The water heater should be drained if being shut down during freezing temperatures. Also periodic draining and cleaning of sediment from the tank may be necessary. Turn the gas control knob to the "OFF" position. CLOSE the cold water inlet valve to the water heater. • OPEN a nearby hot water ...

  • Kenmore POWER MISER 153.330401 - page 22

    Troubleshooting Guide Start Up Conditions CONDENSATION Whenever the water heater is filled with cold water, a certain amount of condensation will form while the burner is on. A water heater may appear to be leakin_when in fact the water is condensation. This usually happens wnen: • When a new water heater is filled with cold water for the first t ...

  • Kenmore POWER MISER 153.330401 - page 23

    Troubleshooting Guide (cont'd) Operational Conditions HOT COLD WATE_ HEAT_ O) COLD WATER pRESSURE INLET FITTING REDUCING VALVE BY-PASS (t) EXPANSION TANK _) PRESSURE GAUGE INLET C WATER SHUTOFF RECOMMENDED INSTALLATION (VERTICAL MOUNTING) SMELLY WATER In each glasslined water heater there is installed at least one anode rod (see parts section) ...

  • Kenmore POWER MISER 153.330401 - page 24

    Troubleshooting Guide (cont'd) Operational Conditions (cont'd) HIGH TEMPERATURE SHUT OFF SYSTEM WATER IS TOO HOT This water heater is equipped with an automatic gas shut offsys- tem. The high temperature shut off is built into the gas control valve. This system shuts off the gas supply to the water heater burners when high water temperatu ...

  • Kenmore POWER MISER 153.330401 - page 25

    Troubleshooting Guide (cont'd) Leakage Checkpoints Use this guide to check a "Leaking" water heater. Many suspect- - ed "Leakers" are not leaking tanks. Often the source of the water can be found and corrected. If you are not thoroughly familiar with your local gas codes, your water heater, and safety ptacdces, contact the ...

  • Kenmore POWER MISER 153.330401 - page 26

    Parts Order List POWER MISER TM 10 GAS WATER HEATERS MODEL NUMBERS: 153.330401 40 Gal. High Altitude 153.330451 40 Gal. 153.330501 50 Gal. High Altitude 153.330551 50 Gal. 153.330701 75 Gal. High Altitude 153.330751 75 Gal 2O 19 18 14 26 ...

  • Kenmore POWER MISER 153.330401 - page 27

    Parts Order List (cont'd) POWER MISER TM 10 GAS _rATER HEATERS MODEL NUMBERS: 153.330401 40 Gal. High Altitude 153.330451 40 Gal. 153.330501 50 Gal. High Altitude 153.330551 50 Gal. 153.330701 75 Gal. High Altitude 153.330751 75 Gal KEY NO. 1 2 3 4 5 153.330401 153.330451 153-330701 153-330751 PART DESCRIPTION Temperature-Pressure Relief Valve ...

  • Kenmore POWER MISER 153.330401 - page 28

    Warranty About Your Warranty THE PRICE OF YOUR WATER HEATER DOES NOT INCLUDE A FREE CHECKUP SERVICE CALL. On Water Heater Installations Arranged By Sears, Sears warrants the installation. ON INSTALLATIONS NOT MADE BY SEARS AUTHORIZED CONTRACTORS: 1. Your Sears warranty applies to the product only. 2. Sears does not warrant the installation. 3. A ch ...

Produzent Kenmore Kategorie Water Heater

Dokumente, die wir vom Produzenten des Geräts Kenmore POWER MISER 153.330401 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Kenmore
- Bedienungsanleitungen POWER MISER 153.330401
- Produktkarten Kenmore
- Informationsbroschüren
- oder Energieetiketten Kenmore POWER MISER 153.330401
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Kenmore POWER MISER 153.330401.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Kenmore POWER MISER 153.330401, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Kenmore POWER MISER 153.330401. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Kenmore POWER MISER 153.330401 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Kenmore POWER MISER 153.330401, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Kenmore POWER MISER 153.330401 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Kenmore POWER MISER 153.330401 verständlich ist.

Eine gänzliche Bedienungsanleitung von Kenmore sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Kenmore POWER MISER 153.330401 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Kenmore POWER MISER 153.330401 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Kenmore POWER MISER 153.330401, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Kenmore POWER MISER 153.330401 - die uns die ersten Schritte während der Nutzung von Kenmore POWER MISER 153.330401 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Kenmore POWER MISER 153.330401 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Kenmore POWER MISER 153.330401 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Kenmore POWER MISER 153.330401?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Kenmore POWER MISER 153.330401 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Kenmore POWER MISER 153.330401 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)