Bedienungsanleitung Hoffman Media EDD-4C

29 Seiten 2.18 mb
Download

Zur Seite of 29

Summary
  • Hoffman Media EDD-4C - page 1

    Copyright © 2010 Hoffmann & Hoffmann Ltd. Rev. 04, May 2010 1 Dripmaster EDD-4C U.S. Patent No. 5,996,739 & other co untries User Guide Document filename: Dripmaster _EDD-4C_User_Gui de_18May10.doc Important notice: Hoffmann & Hoffmann reserves the righ t to change this docum ent without further notice due to design improvements, funct ...

  • Hoffman Media EDD-4C - page 2

    2 Revision History Revision Section Notes 01 – Initial document 02 Installation Kit on page 9 Deleted ¼-inch fuel hose as pa rt of installation kit Page 18 Third line of text: ...flow switch to the right ... Page 7 , 10 , 22 , Table 1 , Figure 9 Line power includes 2 20 VAC Table 6 Updated specifications 03 Last page Updated contact information ...

  • Hoffman Media EDD-4C - page 3

    3 Contents Section 1: In troduction ........................................................................................................ ....................... 5 Overview .......................................................................................................................................... 5 Section 2: In stalla tion ....... ...

  • Hoffman Media EDD-4C - page 4

    4 List of Figures Figure 1: Dripma ster EDD-4C .................................................................................................... ........... 5 Figure 2: Installa tion require ments ............................................................................................ ........... 8 Figure 3: Dripmaster—rear view showing mo ...

  • Hoffman Media EDD-4C - page 5

    5 Section 1: Intr oduction Overview The Dripmaster is an active ve rtical line-s haft lubrication control an d monitoring device. It automatically stabilizes the oil drip rate so as to comply with pu mp manufacturer's requirements. Figure 1: Dripmaster EDD-4C Constant drip rate is maintained reg ardless of am bient temperature or hydrostatic p ...

  • Hoffman Media EDD-4C - page 6

    6 End of section ...

  • Hoffman Media EDD-4C - page 7

    7 Section 2: Installation General The Dripmaster installation procedure is simple and does not require any special tools, but requires site preparation. Well Site Requirements • Line power (115 VAC or 22 0 VAC), or 24 V AC/DC must be available at the well pump. • An eight-wire control cable (c ontaini ng wires not smaller than 2 2 AWG) needs to ...

  • Hoffman Media EDD-4C - page 8

    8 Important: The rel ative spacing between the oil tank, t he Dripmaster, and the line-shaft inlet should be according to Figure 2. In order to maintain minimal oi l pressure on the needle valve (especially when the oil tank is al most empty), t he oil inlet should be in the range of 10 to 14 inches below the oil tank. 10 to 14 inches (25.4 to 35.6 ...

  • Hoffman Media EDD-4C - page 9

    9 Installation Kit The Dripmaster is sup plied with the following parts:  1 – oil filter (fuel filter for ¼-inch hose)  4 – mounting bolts  8 – nuts  8 – lock washers  2 – cable bushings (gland s) Make sure that all of the kit items are present. Y ou need to obtain ¼-inch fuel h ose to complete the installation. Mounting ...

  • Hoffman Media EDD-4C - page 10

    10 Wiring the Power and Control Cables Power and control cables a re routed through the bo ttom of the connection b ox through two strain relief bushings. Power cable e ntry Control cabl e entry Gr e en grou nd w ire connects here Figure 4: Connection box – cable routing Wire the connection box according to Fi gure 5. Connections are descri bed i ...

  • Hoffman Media EDD-4C - page 11

    11 Caution: External 24 VAC power source must be isolated from ground. 2. Route the power cable through a cabl e strain relief on the left side of the connection bo x (Figure 4) . 3. Connect the green ground wire to a cha ssis sc rew or bolt, preferably usi ng a ring terminal. See Figure 4. 4. Route the control cabl e through the right cable strain ...

  • Hoffman Media EDD-4C - page 12

    12 Table 2: Pump On/Off conditions Status OK LED on OK LED off Pump on • Drip rate greater than 15 dpm • O.K. relay contacts are closed • Drip rate less than 15 dpm • Total lack of oil ( OIL LED on) • O.K. relay contacts are open Pump off • Drip rate is equal to or greater than 2 dpm • O.K. relay contacts are closed • Total lack of ...

  • Hoffman Media EDD-4C - page 13

    13 Section 3: Operation Controls and Indicators Button and indicator locations o n the Drip master control panel are shown below. Open Va l ve Drip rate Contr o l Mode Close Va lve Drip Rate toggle switch es Tim i ng t ogg le switches 12-sec ond t im er Freeze Display switch Lack of oi l 5 5 6 6 7 7 12 12 13 13 14 14 15 15 16 16 1 1 4 4 Presenc e o ...

  • Hoffman Media EDD-4C - page 14

    14 Item number (Figure 6) Name Control or Indicator Function 2 OK Green LED Indicates that su fficient oil is delivered whether the well pump is on or off. In the Normal (pump on) mode, this corresponds to oil drip rates in excess of 15 dpm. In the Pre-lube (pump off) mode, the LED lights when the rate is between 1 and 15 dpm. The LED is off when a ...

  • Hoffman Media EDD-4C - page 15

    15 Item number (Figure 6) Name Control or Indicator Function 12 Drip Rate Toggle switches Sets the drip rate for the pump-on mode. Choose only one toggle switch, and push it up to the desired dpm value. 13 Timing Toggle switches These switches are set according to the section "Setting Normal (pump on) Mod e Drip Rates", starting on page 1 ...

  • Hoffman Media EDD-4C - page 16

    16 Automatic Control When the Control Mode toggle switch SW17 is in the lower AUTO position (item 8 in Figure 6), the Dripmaster automatically stabilizes the p reset drip rate. At the end of each 60 second interval, a short correction comman d is given only if there is a deviation from the desi red preset d rip rate. The valve closes if the actual ...

  • Hoffman Media EDD-4C - page 17

    17 35 dpm toggle switch setting 20 25 30 35 40 1248 1 0 40 dpm toggle switch setting 20 25 30 35 40 1248 1 0 The OPEN and CLOSE LEDs indicate whether the n eedle valv e is opening or cl osing. See items 5 and 11 in Figure 6 on page 13. Pre-lube (pump off) Mode To select the Pre-lube mod e, 24 V AC/DC must be ap plied to the S.B. terminals in the co ...

  • Hoffman Media EDD-4C - page 18

    18 Manua l oil f low sw itch Drip ver ification pe epho le Oil in let Oil outlet Interna l so leno id Figure 7: Dripmaster EDD- 4C Needle Valve Ass embly The internal solenoid is powered by the Dripmaster power source. When powered up, the sol enoid allows oil flow. When powered down, the solenoid bloc ks oil flow. To allow oil flow when the Dripma ...

  • Hoffman Media EDD-4C - page 19

    19 Section 4: Theory of Operation General The Dripmaster is a gravity-base d oil lubrication system. The common needle valve fed from an oi l tank does not provide an y regulation of the drip rate—the rate varies in response to variations in temper ature (day versus nig ht and time of year) and changes in the tank oil level (hydrostatic pressure) ...

  • Hoffman Media EDD-4C - page 20

    20 Mechanical Stage Optic Drop Dete cto r Needle Valve Oil Outlet to Shaft Oil In let from Reserv oir Lack of Oil O.K. state Drop Pulses Normal / Pre- lube Mode s Line voltage (115V or 23 0 V) or 2 4V Feed T o S C ADA I nt e rf a c e Control Circuitry Pow er Su pply Servo Mot o r Pr eset S elect ors & Displ ay Figure 9: Dripmaster functional di ...

  • Hoffman Media EDD-4C - page 21

    21 A built-in, SCADA-compatible report-back m echanism provides the status and alarm info rmation. This information is sent to the local PL C on site. The following si gnals are reported: • OK state – signals that the oil drip rate exceeds a factory-set thre shold. Whenever the oil drip rate falls below this threshold, the OK state is disabled ...

  • Hoffman Media EDD-4C - page 22

    22 lower limit and the OIL LED lights continuously. The LL relay outlet contact cl oses, transmitting a total lack of oil condition. At this stage, there is no vertical line-shaft lubricatio n which means that either the oil tank is empty or there is an oil flow blockage between the oil tank outlet and the Dripmaster inlet. In the case of oil flow ...

  • Hoffman Media EDD-4C - page 23

    23 Section 5: Maintenance and T roub leshooting Table 4: Routine Maintenance Task Frequency Check for oil leaks Monthly Oil filter change (the oil filter used can be an automotive fuel filter with ¼" fittings) Every six months Check for normal operation • The displayed drip rate is equal to the Norm al (pump on) mode drip rate setting, with ...

  • Hoffman Media EDD-4C - page 24

    24 Problem Possible Cause Solution The OIL LED is on. • Oil tank is empty • A shut-off valve at the outlet of the oil tank might be closed • Oil flow from the oil tank may be obstructed; the oil filter may be clogged • Oil blockage between the Dripmaster outlet pipe and the line-shaft—excessive oil briefly flows from a built-in overflow h ...

  • Hoffman Media EDD-4C - page 25

    25 Section 6: Specifications Table 6: Dripmaster EDD-4C specifica tions Power requirements 115 VAC, 10 VA, or 24 V AC/DC 220 VAC, 10 VA or 24 V AC/DC Normal (pump on) mode preset drip rates 20, 25, 30, 35, 40 dpm Pre-lube (pump off) mode drip rate 2 dpm Drip volume 50 drops per 1 cc PULSE relay contact 35 VDC – 0.5 A O.K. relay contact 250 VAC ? ...

  • Hoffman Media EDD-4C - page 26

    26 Overall Dimensions 3 . 5 8 i n c h e s ( 9 . 1 c m ) 1 0 . 3 5 i n c h e s ( 2 6 . 3 c m ) 3 . 1 9 i n c h e s ( 8 . 1 c m ) 4 . 8 8 i n c h e s ( 1 2 . 4 c m ) 6.38 inches (16.2 cm) 4.92 inches (12.5 cm) Drip verification peephole Oil outlet 1/4 inch BSP Display w indow Oil inlet 1/4 inch BSP Power cable entry Control cable entry Connection box ...

  • Hoffman Media EDD-4C - page 27

    27 Section 7: Dripmaster Service P olicy This policy has been establ ished to cover the servi cing of Hoffmann & Hoffmann prod ucts, regardless if it is within or beyond the warra nty period. Installation 1. The installation services requi red for th e Dripmaster inclu des the following: a. Infrastructure (trench diggi ng, cable laying) b. Oil ...

  • Hoffman Media EDD-4C - page 28

    28 Product within the Warranty Period 1. All Hoffmann & Hoffmann product s have a one year limited warrant y. 2. Hoffmann & Hoffmann Warranty will app ly only to units installed by authorized Rep/Di stributors or by the customer (if Hoffmann & Hoff mann au thorized installation by the customer). 3. Hoffmann & Hoffmann is not re spon ...

  • Hoffman Media EDD-4C - page 29

    29 2. Return properly packaged item to the address of your local Rep/Distributor o r to Hoffmann & Hoffmann lab. 3. This warranty is limited to the repair or repla c ement of the Hoffmann & Hoffmann product s only. Hoffmann & Hoffmann assumes no othe r responsibility or liability. 4. Hoffmann & Hoffmann reserves the righ t to make c ...

Produzent Hoffman Media Kategorie Water Pump

Dokumente, die wir vom Produzenten des Geräts Hoffman Media EDD-4C erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Hoffman Media
- Bedienungsanleitungen EDD-4C
- Produktkarten Hoffman Media
- Informationsbroschüren
- oder Energieetiketten Hoffman Media EDD-4C
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Hoffman Media EDD-4C.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Hoffman Media EDD-4C, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Hoffman Media EDD-4C. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Hoffman Media EDD-4C ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Hoffman Media EDD-4C, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Hoffman Media EDD-4C hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Hoffman Media EDD-4C verständlich ist.

Eine gänzliche Bedienungsanleitung von Hoffman Media sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Hoffman Media EDD-4C bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Hoffman Media EDD-4C befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Hoffman Media EDD-4C, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Hoffman Media EDD-4C - die uns die ersten Schritte während der Nutzung von Hoffman Media EDD-4C erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Hoffman Media EDD-4C hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Hoffman Media EDD-4C im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Hoffman Media EDD-4C?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Hoffman Media EDD-4C nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Hoffman Media EDD-4C hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)