Bedienungsanleitung Lincoln Electric SA-250

33 Seiten 0.46 mb
Download

Zur Seite of 33

Summary
  • Lincoln Electric SA-250 - page 1

    S A-250 OPERA TOR’S MANUAL For Machines with Code Numbers 10890 IM747 January, 2003 Safety Depends on You Lincoln arc welding equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thoughtful operation on your part. DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT WITHOUT ...

  • Lincoln Electric SA-250 - page 2

    FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. ________________________________________________ ...

  • Lincoln Electric SA-250 - page 3

    ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistant material to protect your skin ...

  • Lincoln Electric SA-250 - page 4

    FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations. 8.c. Ground the equipment in accordance with the U.S. National Electrical C ...

  • Lincoln Electric SA-250 - page 5

    iv SAFETY iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1. Protegez-vous contre la secousse électrique: a. Les circuits ? ...

  • Lincoln Electric SA-250 - page 6

    Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay par ...

  • Lincoln Electric SA-250 - page 7

    vi vi T ABLE OF CONTENTS Page ________________________________________________________________________ Installation .......................................................................................................Section A Technical Specifications ........................................................................................A-1 Pre- ...

  • Lincoln Electric SA-250 - page 8

    A-1 INST ALLA TION SA-250 A-1 Make/Model Description Horsepower Operating Displacement cu. in.(ltrs) Starting Capacities @ 1800RPM S PEED System 1. Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced. * ...

  • Lincoln Electric SA-250 - page 9

    A-2 INST ALLA TION SA-250 A-2 PRE-OPERA TION INST ALLA TION EXHAUST SP ARK ARRESTER Some federal, state or local laws may require that engines be equipped with exhaust spark arresters when they are operated in certain locations where unarrested sparks may present a fire hazard. The standard muffler included with this welder does not qualify as a sp ...

  • Lincoln Electric SA-250 - page 10

    PRE-OPERA TION SER VICE READ the engine operating and maintenance instruc- tions supplied with this machine. OIL This unit is supplied from the factory with the engine crankcase filled with a high quality SAE 10W/30 oil. This oil should be acceptable for most typical ambient temperatures. Consult the engine operation manual for specific engine manu ...

  • Lincoln Electric SA-250 - page 11

    A-4 INST ALLA TION SA-250 A-4 Battery Charging The SA-250 is equipped with a wet charged battery. The charging current is automatically regulated when the battery is low (after starting the engine) to a trickle current when the battery is fully charged. When replacing, jumping or otherwise connecting the battery to the battery cables, the proper po ...

  • Lincoln Electric SA-250 - page 12

    B-1 OPERA TION B-1 SAFETY PRECAUTIONS GENERAL DESCRIPTION The SA-250 is a heavy duty, engine driven, DC arc welding power source, capable of providing constant current output for stick welding or DC TIG welding. This welder is wound with all copper coils, rated at 300 amps/32 Volts. With the addition of the optional Wire Feed Module, the SA - 250 w ...

  • Lincoln Electric SA-250 - page 13

    B-2 OPERA TION B-2 ENGINE OPERA TION Operate the welder with the doors closed. Leaving the doors open changes the designed air flow and can cause overheating. STARTING the SA-250 PERKINS 104-22 DIESEL ENGINE 1. Turn the “IDLER” switch to “HIGH”. 2. Turn the “IGNITION” switch to “ON”. 3. Press the Glow Plug button for 20 to 30 second ...

  • Lincoln Electric SA-250 - page 14

    B-3 OPERA TION B-3 SA-250 WELDER OPERA TION DUTY CYCLE The NEMA output rating of the SA-250 is 300 amperes at 32 arc volts on a 60% duty cycle (consult Specifications in this manual for alternate ratings). Duty cycle is based on a ten minute period; thus, the welder can be loaded at rated output for six minutes out of every ten minute period. CONTR ...

  • Lincoln Electric SA-250 - page 15

    B-4 OPERA TION B-4 SA-250 AUXILIARY POWER The AC auxiliary power, supplied as a standard, has a rating of 3.0 kVA of 115/230 VAC (60 hertz). With the 3.0 kVA, 115/230 VAC auxiliary power, one 115V duplex and one 230V duplex, grounding type receptacle are provided. The circuit is protected with circuit breakers. The rating of 3.0 kVA permits a maxim ...

  • Lincoln Electric SA-250 - page 16

    C-1 ACCESSORIES C-1 SA-250 OPTIONAL FEA TURES (Field Installed) Accessory Set (K704) - Includes electrode and work cables, headshield, work clamp and electrode holder. TIG Module (K930-2) - Portable, high frequency unit with gas valve for TIG welding. Rated at 300 amps / 60% duty cycle. (Request Publication E3.205). Power Plug Kit (K802D) - A power ...

  • Lincoln Electric SA-250 - page 17

    D-1 MAINTENANCE D-1 MAINTENANCE GENERAL INSTRUCTIONS • Blow out the welder and controls with an air hose at least once every two months. In particularly dirty locations, this cleaning may be necessary once a week. Use low pressure air to avoid driving dirt into the insulation. • “Current Range Selector” contacts should not be greased. To ke ...

  • Lincoln Electric SA-250 - page 18

    D-2 MAINTENANCE D-2 Lincoln brushes have a curved face to fit the commu- tator. Have an experienced maintenance man seat these brushes by lightly stoning the commutator as the armature rotates at full speed until contact is made across the full face of the brushes. After stoning, blow out the dust with low pressure air. To seat slip ring brushes, p ...

  • Lincoln Electric SA-250 - page 19

    D-3 D-3 SA-250 MAINTENANCE I EVERY 400 HOURS OR 12 MONTHS EVERY 200 HOURS OR 6 MONTHS EVERY 100 HOURS OR 3 MONTHS FIRST SERVICE-(20 / 50 HOURS) EVERY DAY OR EVERY 8 HOURS If necessary use shorter periods. These preventive maintenance periods apply to average conditions of operation. Perkins #1300366020 TYPE OR QUANTITY Above operations to be carrie ...

  • Lincoln Electric SA-250 - page 20

    E-1 TROUBLESHOOTING E-1 SA-250 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION This Troubleshooting Guide is provided to help you locate and repair possible ...

  • Lincoln Electric SA-250 - page 21

    E-2 WELDER TROUBLESHOOTING E-2 SA 250 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBLEMS ...

  • Lincoln Electric SA-250 - page 22

    E-3 ENGINE TROUBLESHOOTING E-3 SA 250 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBLEMS ...

  • Lincoln Electric SA-250 - page 23

    E-4 ENGINE TROUBLESHOOTING E-4 SA-250 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed. CAUTION PROBLEMS ...

  • Lincoln Electric SA-250 - page 24

    E-5 TROUBLESHOOTING SA-250 E-5 ELECTRONIC IDLER TROUBLESHOOTING GUIDE With Idler Control Switch in the Auto Position, Engine Will Not Return to Low Idle in Approximately 15 Seconds After Welding and Auxiliary Loads are Removed Set Idler Control Switch to the Auto Position Check for Continuity through Idler Control Switch Open Closed Measure DC Volt ...

  • Lincoln Electric SA-250 - page 25

    E-6 TROUBLESHOOTING SA-250 E-6 ELECTRONIC IDLER TROUBLESHOOTING GUIDE With Idler Control Switch in the AUTO Position, Engine Will Not Pick Up Speed When: The Arc is Struck Reed Switch in Weld Circuit Defective -- Will Not Close To Check: Short the Red Lead on P.C. Board to Welder Frame. The Auxiliary Power Load is Turned ON Power Load Too Small Try ...

  • Lincoln Electric SA-250 - page 26

    F-1 DIAGRAMS F-1 SA-250 M20016 C + - + - R W B SLIP RINGS 346 A 54 3 2 1 CB3 CB1 115 VOLT RECEPTACLE 230 VOLT RECEPTACLE WELDER LEAD BL OCK AC AC 42 602A U CB2 CB4 1 2 3 4 5 6 600A 41 GENERAT O R N -W 48 START + 52 + IDLER SOLENOI D - P9 J8 POSIT IVE 400D 400E - 51 56 RHEOSTAT EXC ALTERNATOR + PUMP SOLENOID 50 50B (CC+) & (CV+ W ITH W.F.M.) S B ...

  • Lincoln Electric SA-250 - page 27

    F-2 DIMENSION PRINT F-2 SA-250 M8869-24 A 28.00 22.00 22.14 24.50 27.12 25.00 31.75 51.50 6.00 32.82 42.63 43.13 48.50 53.75 61.00 65.25 67.00 8.12 3.00 .88 16.30 33.75 N.B. N.A. N.A. N.A. N.B. N.C. NOTES: N.A. .81 HOLES N.B. .69 HOLES N.C. CENTER OF GRAVITY WI TH OIL AND COOLANT IN ENGI NE, BUT NOT F UEL. ...

  • Lincoln Electric SA-250 - page 28

    NOTES SA-250 ...

  • Lincoln Electric SA-250 - page 29

    NOTES SA-250 ...

  • Lincoln Electric SA-250 - page 30

    Now A vailable...12th Edition The Procedure Handbook of Arc Welding With over 500,000 copies of previous editions published since 1933, the Procedure Handbook is considered by many to be the “ Bible ” of the arc welding industry. This printing will go fast so don ’ t delay. Place your order now using the coupon below. The hardbound book conta ...

  • Lincoln Electric SA-250 - page 31

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES. SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL F ABRICANTE PARA EL ...

  • Lincoln Electric SA-250 - page 32

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE PARA ESTE EQUIP AMENTO E AS PAR TES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR. ● Keep your head out of fumes. ● Use ventilation or exhaust to remove fumes f ...

  • Lincoln Electric SA-250 - page 33

    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • ...

Produzent Lincoln Electric Kategorie Welding System

Dokumente, die wir vom Produzenten des Geräts Lincoln Electric SA-250 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Lincoln Electric
- Bedienungsanleitungen SA-250
- Produktkarten Lincoln Electric
- Informationsbroschüren
- oder Energieetiketten Lincoln Electric SA-250
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Lincoln Electric SA-250.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Lincoln Electric SA-250, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Lincoln Electric SA-250. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Lincoln Electric SA-250 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Lincoln Electric SA-250, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Lincoln Electric SA-250 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Lincoln Electric SA-250 verständlich ist.

Eine gänzliche Bedienungsanleitung von Lincoln Electric sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Lincoln Electric SA-250 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Lincoln Electric SA-250 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Lincoln Electric SA-250, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Lincoln Electric SA-250 - die uns die ersten Schritte während der Nutzung von Lincoln Electric SA-250 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Lincoln Electric SA-250 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Lincoln Electric SA-250 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Lincoln Electric SA-250?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Lincoln Electric SA-250 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Lincoln Electric SA-250 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)