    FieldPoint ™ Operating Instructions FP-AI-112 and cFP-AI-112 16-Channel, 16-Bit Anal og Input Modu les These operating instructions descri be ho w to install and use the FP-AI-112 and cFP-AI-112 analog input modules (referred to inclusiv ely as the [c]FP-A I-112). Fo r information about configuring and accessing the [c]F P- AI-112 ov er a network ...

  • National Instruments FP-AI-112 - page 2

    FP-AI-112 and cFP-AI-112 2 ni.com T o install the FP- AI-112, refer to Figure 1 and complete the follow ing steps: 1. Slide the terminal base key to either position X (used for an y module) or position 1 (used for the FP- AI-112). 2. Align the FP- AI-112 alignmen t sl ots with the guide rails on the terminal base. 3. Press firmly to seat the FP- AI ...

  • National Instruments FP-AI-112 - page 3

    © National Instruments Corp. 3 FP-AI-112 and cFP-AI-112 3. Using a number 2 Phillips scre wdriv er with a shank of at least 64 mm (2.5 in.) length, tighten the captiv e screws to 1. 1 N ⋅ m (10 lb ⋅ in.) of torque. The n ylon coating on the screws pre vents them from loosening. Figure 2. Installing the cFP-AI-112 Wiring the [c]FP-AI-112 The FP ...

  • National Instruments FP-AI-112 - page 4

    FP-AI-112 and cFP-AI-112 4 ni.com Y ou can use an external power supply to po wer field de vices. Connect the positi ve lead of the e xternal power supply to both V terminals and the negat ive lead to both C termina ls. Ensure that the current through both V terminals can nev er exceed 2 A. Install 2 A maximum, fast-acting fuses between the e xtern ...

  • National Instruments FP-AI-112 - page 5

    © National Instruments Corp. 5 FP-AI-112 and cFP-AI-112 Caution Cascading power between two modules defeats isolation between those modules. Cascading power from the network module defeats all isolation between modules in the FieldPoint bank. Measuring V oltage with the [c]FP-AI-112 Figure 3 sho ws how to connect a v oltage source without an exter ...

  • National Instruments FP-AI-112 - page 6

    FP-AI-112 and cFP-AI-112 6 ni.com Input Ranges The input ranges for voltage signals are 0 –1 V , 0 –5 V , 0 –10 V , ± 60 mV , ± 300 mV , ± 1V , ± 5 V , and ± 10 V . T o prevent inaccurate readings, choose an input range such that the signal you are measuring does not exceed either end of the rang e. Signals that greatly ex ceed the confi ...

  • National Instruments FP-AI-112 - page 7

    © National Instruments Corp. 7 FP-AI-112 and cFP-AI-112 ( number of input range s with 60 Hz filter ) × 0.10 s + ( number of channels with 500 Hz filter ) × 0.007 s + ( number of input ranges with 500 Hz filter ) × 0.012 s + 0.16 s = Update Period For the f astest performance, conf igure all unused channels for the 500 Hz f ilter setting and fo ...

  • National Instruments FP-AI-112 - page 8

    FP-AI-112 and cFP-AI-112 8 ni.com Isolation and Sa fety Guidelines Caution Read the following in formation before attempting to connect the [c]F P-AI-112 to an y circuits that may contain hazardous voltages. This section describes the isolat ion of the [c]FP-AI-112 and its compliance wit h international sa fety standards. The field wiring connectio ...

  • National Instruments FP-AI-112 - page 9

    © National Instruments Corp. 9 FP-AI-112 and cFP-AI-112 using 14 A WG (1.6 mm) wire with a ring lug. Use the 5/16 in. panhead screw shipped with the backplane to secure the ring lug to the backplane PE ground terminal. • As with any hazardous v oltage wiring, make sure that all wiring and connections meet appl icable electrical codes and commons ...

  • National Instruments FP-AI-112 - page 10

    FP-AI-112 and cFP-AI-112 10 ni.com Effecti ve resolution by inpu t range and filter setting Update period and input band width by filter setting Normal-mode rejection ............. ........ 95 dB Nonlinearity .......... ........... ......... ........ 0.0015% (monotonicity 1 warranted ov er the operating temperature range) Input impedance (with powe ...

  • National Instruments FP-AI-112 - page 11

    © National Instruments Corp. 11 FP-AI-112 and cFP-AI-112 T ypical and warranted accuracy b y input range and temperature range Note Full scale is the maximum value of the nominal input range. F or example, for the ± 10 V input range, full scale is 10 V and ± 0.01% of full scale is 1 mV . Gain error drift ...... ......... ........... ........ ± ...

  • National Instruments FP-AI-112 - page 12

    FP-AI-112 and cFP-AI-112 12 ni.com Physical Char acteristics Indicators ................... ......... ........... ... Green POWER and READY indicators W eight FP-AI-112..... ............. ............ ..... 142 g (5.0 oz) cFP-AI-112 ....... ............ .............. 113 g (4.0 oz) Power Requirements Power from network module ............ 350 mW I ...

  • National Instruments FP-AI-112 - page 13

    © National Instruments Corp. 13 FP-AI-112 and cFP-AI-112 Shock and Vibration These specifications apply only to the cFP-AI-112. NI recommends Compact FieldP oint if your application is subject to shock and vibration. Operating vibration, random (IEC 60068-2-64)....... ........... ............ 1 0 –500 Hz, 5 g rms Operating vibration, sinusoidal ...

  • National Instruments FP-AI-112 - page 14

    FP-AI-112 and cFP-AI-112 14 ni.com CE Compliance This product meets the essentia l requirements of applicable European Directi ves, as amended for CE ma rking, as follows: Lo w-V oltage Directi ve (s afety)...... ... 73/23/EEC Electromagnet ic Compatibility Directiv e (EMC) ... ........... ......... ........ 89/336/EEC Note Refer to the Declaration ...

  • National Instruments FP-AI-112 - page 15

    © National Instruments Corp. 15 FP-AI-112 and cFP-AI-112 Where to Go for Support For more information about settin g up the FieldPoint system, refer to these National Instruments documents: • FieldPoint network module user manual • Other FieldPo int I/O m odule operating instructions • FieldPoint terminal base and connector block operating i ...

  • National Instruments FP-AI-112 - page 16

    © 2004 National I nstruments Corp. All rights reser ved. 371330A-01 Jul04 *371330A-01* FieldPoint™, Nati onal Instruments™, NI™, and ni.com™ are trademarks of National Instruments Corporati on. Product and company names ment ioned herein are trademarks or trade names of thei r respective companies. For patents covering National Instruments ...

Produzent National Instruments Kategorie Welding System

Dokumente, die wir vom Produzenten des Geräts National Instruments FP-AI-112 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen National Instruments
- Bedienungsanleitungen FP-AI-112
- Produktkarten National Instruments
- Informationsbroschüren
- oder Energieetiketten National Instruments FP-AI-112
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung National Instruments FP-AI-112.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen National Instruments FP-AI-112, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen National Instruments FP-AI-112. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts National Instruments FP-AI-112 ansehen.

Die komplette Bedienungsanleitung des Geräts National Instruments FP-AI-112, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von National Instruments FP-AI-112 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von National Instruments FP-AI-112 verständlich ist.

Eine gänzliche Bedienungsanleitung von National Instruments sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von National Instruments FP-AI-112 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von National Instruments FP-AI-112 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich National Instruments FP-AI-112, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts National Instruments FP-AI-112 - die uns die ersten Schritte während der Nutzung von National Instruments FP-AI-112 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit National Instruments FP-AI-112 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von National Instruments FP-AI-112 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich National Instruments FP-AI-112?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit National Instruments FP-AI-112 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit National Instruments FP-AI-112 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)