Bedienungsanleitung GarrettCom Magnum 3000

59 Seiten 0.38 mb
Download

Zur Seite of 59

Summary
  • GarrettCom Magnum 3000 - page 1

    www Garre t t Com com .. www Garre t t Com com .. Corporate Headquarters GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http ://www.GarrettCom .com email support@garrettc om.com Magnum 3000 Stackable Hubs Installation and User Guide ...

  • GarrettCom Magnum 3000 - page 2

    Magnum 3000 Stackable Hubs I nstallation and User Guide ( 07/06) i www Garre t t C om c om .. Magnum  3000 Stackable Hubs Installation and User Guide Part #: 84-00060 (Rev. 04/02 ) Trademarks Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories Garret ...

  • GarrettCom Magnum 3000 - page 3

    Magnum 3000 Stackable Hubs I nstallation and User Guide ( 07/06) ii www Garre t t C om c om .. Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Dr. Fremont, CA 94539-7437 Phone (510) 438-9071 Fax (510) 438-9072 Website: http ://www.GarrettCom .com em ...

  • GarrettCom Magnum 3000 - page 4

    Magnum 3000 Stackable Hubs I nstallation and User Guide ( 07/06) iii www Garre t t C om c om .. PREFACE This user guide is divide d into six main sections: SECTION 1 covers the product specifications for Magnum 3000 Stackable Hubs family, and also provides ordering information. SECTION 2 covers the Magnum 3024 and 3012 Stackable Hubs. SECTION 3 d e ...

  • GarrettCom Magnum 3000 - page 5

    Magnum 3000 Stackable Hubs I nstallation and User Guide ( 07/06) iv www Garre t t C om c om .. Table of Contents Page 1.0 SPECIFICATIONS - MAGNUM 3024, MAGNUM 3012................ 1 1.1 Specifications - Repeater Port Modules (RPM s); Bonus Ports ........... 3 1.2 Specifications - Bridge Port Modules (BPMs); B onus Ports ............. 3 1.3 Ordering ...

  • GarrettCom Magnum 3000 - page 6

    Magnum 3000 Stackable Hubs I nstallation and User Guide ( 07/06) v www Garre t t C om c om .. 5.0 INTRO SIMPLE NTWRK MGMT PROTOCOL (SNMP) AGENTS32 5.1 SNMP Agents Description ................................................................. 32 5.1.1 Embedded SNMP Agent, M odel 3000-MB .............................. 32 5.1.2 Separate Agent Box, Mode ...

  • GarrettCom Magnum 3000 - page 7

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) www Garre t t C om c om .. The Magnum Line ETHERNET CONNECTIVITY PRODUCTS "DESIGNED AND M ANUFACTURED IN THE USA" OVERVIEW GarrettCom, Inc.offers the premium-quality Magnum  line of Ethernet LAN connectivity products with industry-sta ndard functionality and built-in fiber ...

  • GarrettCom Magnum 3000 - page 8

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 1 www Garre t t C om c om .. 1.0 Specifications - Magnum 3024, Magnum 3012 Performance Data Rate: 10 Mbps RPM Partitioning: Enforced after 32 consecutive collisions RPM Reconnect: Occurs af ter 512 bits error-free reception BPM Auto-Learning Address List: 256 nodes capacity BPM Filterin ...

  • GarrettCom Magnum 3000 - page 9

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 2 www Garre t t C om c om .. DC Power Suppl y (Options) -48VDC Power Input Voltage : 36 to 72 VDC 24VDC Power Input Voltage : 20 to 36VDC 125VDC Power Input Voltage : 120 to 300VDC Std. Terminal Bl oc k : “ -, GND, + ” Power Consumption: sam e as for AC models, see above For Dual So ...

  • GarrettCom Magnum 3000 - page 10

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 3 www Garre t t C om c om .. 1.1 Specifications - Repeater Port Modules (RPMs); Bonus Ports RPM Type : BNC AUI DTE Fiber-mm Fiber-sgl.m TP* Front Access yes yes yes yes yes y es Connector Type BNC-f DB-15 f DB-15 m Fiber-ST Fiber-ST RJ-45 Partition (PART)LED yes yes yes yes yes yes Rece ...

  • GarrettCom Magnum 3000 - page 11

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 4 www Garre t t C om c om .. 1.3 Ordering Information Magnum 3000 Stackable Hubs and Concentrators Magnum 3024 Base Chassis with 24 RJ-45 ports, shielded connectors Magnum 3012 Base Chassis with 12 RJ-45 ports, shielded connectors ETSI and NEBS-certified models, -48VDC powered Magnum 30 ...

  • GarrettCom Magnum 3000 - page 12

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 5 www Garre t t C om c om .. 2.0 Introduction - Mag num 3012 and 3024 Stackable Hubs This section describes the features and capabilities of the Magnum 3012 and 3024 Stackable Hubs, including bonus ports , applications, installation, and operation. 2.1 Inspecting the Package and Product ...

  • GarrettCom Magnum 3000 - page 13

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 6 www Garre t t C om c om .. 2.2 Product Description - Magnum 3000 Stackable Hubs Magnum 3000 Stackable Hubs are suita ble for small- to medium-size enterprises needing an Ethernet local area ne twork, either managed or unmanaged. They will operate, individually or combined in a st ack, ...

  • GarrettCom Magnum 3000 - page 14

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 7 www Garre t t C om c om .. 2.3 Magnum 3024 Hub - 24 RJ-45 Ports, One PM bonus port slot The Magnum 3024 Hub provides 24 RJ-45 por ts on the front of the unit plus a Bonus Port slot on the rear which may be configured with any Magnum Port Module (PM). User-segment wiring connections ar ...

  • GarrettCom Magnum 3000 - page 15

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 8 www Garre t t C om c om .. The IRB ribbon cables supplied with each Magnum 3000 base unit are slightly longer than the base unit height. Thus, an IRB cable segment has a small arc shape when it is properly installed. It is possible to have some long IRB ribbon cable segments, up to a ...

  • GarrettCom Magnum 3000 - page 16

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 9 www Garre t t C om c om .. into two logical repeaters with separate collision domains, while still passing SNMP management data through the SRC so that the agent can manage both repeaters. Then, a local bridge can be installed between the two repeaters using a port from each (for exam ...

  • GarrettCom Magnum 3000 - page 17

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 10 www Garre t t C om c om .. NOTE: To differentiate the SRC cable fro m the IRB cable, GC I uses colored ribbon cable for the SRC. The standard IRB cables are gray in color. 2.3.3 Group # Address Switch Settings, for Managed Units and Stacks The eight-position DIP switch on the rear pa ...

  • GarrettCom Magnum 3000 - page 18

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 11 www Garre t t C om c om .. The Group # switch settings must not be the same for any two Magnum 3000 units operating in one managed stack. Factory default switch settings cannot be relied upon, and the user must check and/or change the Group # address switch settings for each managed ...

  • GarrettCom Magnum 3000 - page 19

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 12 www Garre t t C om c om .. There is no upgrade from a Model 3012 to a Model 3024 since it would not provide an economical method of adding ports. Note that the high degree of stacking of Magnum 3000s - up to 20 units! - provides esse ntially unlimited expansion of the number of users ...

  • GarrettCom Magnum 3000 - page 20

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 13 www Garre t t C om c om .. The family of standard connector type s for BPMs is shown in Figure 2.5b. Figure 2.5b: Magnum BPM Modules for Bonus Ports (left to right above) BPM-BNC, BPM-AUI, BPM-FST, BPM-TP (Note: When an RPM-AUI type is conf igured as a bonus port, it is typically imp ...

  • GarrettCom Magnum 3000 - page 21

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 14 www Garre t t C om c om .. When installing a PM into the Bonus Port slot of the Magnum 3024, use the 16-pin header labeled P1 (also labeled RPM) on the circuit board corresponding to ports 13-24. The red stripe of the connector cable should connect to pin 1 of header P1. NOTE: The PM ...

  • GarrettCom Magnum 3000 - page 22

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 15 www Garre t t C om c om .. 2.6 Features and Benefits, Magnum 3024 and 3012 Hubs  24 Port and 12 Port "Building Block" Hub Models The 24 port units provide high density and low cost-per-port. The 12 port units provide minimum add-on and entry-level system cost. The two un ...

  • GarrettCom Magnum 3000 - page 23

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 16 www Garre t t C om c om .. 2.7 Applications The Magnum 3000 Stackable Hubs provi de a flexible and cost-effective solution to a variety of Ethernet networking applications. The combination of Stackable Hubs and Stackable Mixed-Media Concentr ators with optional SNMP is unique and pow ...

  • GarrettCom Magnum 3000 - page 24

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 17 www Garre t t C om c om .. 3.0 Installation and Operation Before installing the equipment, it is necessary to take the following precautions: 1) If the equipment is mounted in an enclosed or multiple rack assembly, the environmental temperature around the equipment must be less than ...

  • GarrettCom Magnum 3000 - page 25

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 18 www Garre t t C om c om .. 3.1.2 Connecting ThickNet 10BASE5 (AUI) Using the steps below as a guide, att ach a new or existing 10BASE5 ThickNet drop-cable directly to the AUI connector on the RPM-AUI or BPM-AUI port. 1. Plug the cable’s male end into the fem ale AUI connector on th ...

  • GarrettCom Magnum 3000 - page 26

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 19 www Garre t t C om c om .. 1. Before connecting the fiber optic cable, remove the protective dust caps from the tips of the connectors on the PM-ST. Save these dust caps for future use. 2. Wipe clean the ends of the dual connector s with a soft cloth or lint-free lens tissue dampened ...

  • GarrettCom Magnum 3000 - page 27

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 20 www Garre t t C om c om .. and the “Cable Loss” for 100/140 (Multi-mode) is 3.3 dB/km, and the “Cable Loss” for 9/125 (Single-mode) is 0.5 dB/km The following data has been collected from component manufacturer’s (HP’s and Siemens’) web sites and catalogs to provide gui ...

  • GarrettCom Magnum 3000 - page 28

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 21 www Garre t t C om c om .. The ETSI (European Telephone Standard ) brackets are similar to the 19” brackets but use metric dimensions. The optional 23” brackets and the ETSI brackets come as a pair in a package along with the necessary screws for attaching the brackets to the sid ...

  • GarrettCom Magnum 3000 - page 29

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 22 www Garre t t C om c om .. 4.0 Introduction - Magnum Port Modules This chapter describes each Port Module (PM), including appearance, functionality, and status displays. 4.1 Inspecting the Package and Product This section applies only to PMs shi pped as separate items, i.e., only to ...

  • GarrettCom Magnum 3000 - page 30

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 23 www Garre t t C om c om .. 4.2.1 RPM-BNC The Magnum RPM-BNC repeater modul e is equipped with a standard 10BASE2 coax connector. This RPM perfo rms full IEEE 802.3 repeater functionality and is used for 10BASE2 ThinNet (comm only referred to as BNC) connections. The RPM-BNC module is ...

  • GarrettCom Magnum 3000 - page 31

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 24 www Garre t t C om c om .. The RPM-AUI is equipped with a 15 pin female AUI connector and a slide- lock, and performs full IEEE 802.3 repeater functionality. It is used to provide connectivity with a 10BASE5 (ThickNet) backbone or to any AUI segments. A transceiver is required when c ...

  • GarrettCom Magnum 3000 - page 32

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 25 www Garre t t C om c om .. The RPM-AUI connector supports sta ndard IEEE signals, as follows: Table 3.2.2: AUI Pin Assignments Pin Fu nction Pin Function 1 Control In Circuit Shield 10 Data Out Circuit B 2 Control In Circuit A 11 Data Out Circuit S hield 3 Data Out Circuit A 12 Data ...

  • GarrettCom Magnum 3000 - page 33

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 26 www Garre t t C om c om .. 4.2.4 RPM-FST (Fiber ST, Twist-lock Connector) The Magnum RPM-FST is a multi-mode fiber optic module equipped with a dual ST-type connector. It functions as an IEEE 802.3 full repeater to support 10BASE-FL and FOIRL network segments. When used for 10BASE-FL ...

  • GarrettCom Magnum 3000 - page 34

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 27 www Garre t t C om c om .. 4.2.5 RPM-FSC (Fiber SC, Snap-in Connector) The Magnum RPM-FSC is also a multi-mode fiber optic repeater module, similar to the RPM-FST. It has the sam e LEDs indicating port partitioned (PART), receive activity (RX), and link operational (LINK). It has the ...

  • GarrettCom Magnum 3000 - page 35

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 28 www Garre t t C om c om .. NOTE: The RPM-SMF circuit board contains a six pin 3-position jumper, but the jumper is only to be placed across pins 5 & 6. The others are not used. JUMPER ACROSS DISTANCES SUPPORTED 1 - 2 not used 3 - 4 not used 5 - 6 0 - 10 Km 4.2.7 RPM-TP (Twisted P ...

  • GarrettCom Magnum 3000 - page 36

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 29 www Garre t t C om c om .. Important Note: For the RPM-TP MDI-X Crossover Switch - DOWN (or Right) for workstations and user connections. UP (or Left) for Up-Link connections to other hubs, etc. (To help recall the right TP switch position, remember "up for up-link" ! ) The ...

  • GarrettCom Magnum 3000 - page 37

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 30 www Garre t t C om c om .. 4.2.9 BPM-AUI This local-bridge module is equipped w ith a 15 pin female AUI connector and a slide-lock. It is self-learning and filters and forwards packets at full Ethernet wire speed. It is used to provide segment isolation from a 10BASE5 (ThickNet) back ...

  • GarrettCom Magnum 3000 - page 38

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 31 www Garre t t C om c om .. 4.2.11 BPM-TP The Magnum BPM-TP card is equipped with a single RJ-45 connector and supports Ethernet twisted pair segments of any standard lengt h. The RJ-45 connector is shielded to minimize emissions and will allow both unshielded tw isted pair (UTP) and ...

  • GarrettCom Magnum 3000 - page 39

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 32 www Garre t t C om c om .. 5.0 Introduction - Simple Netw ork Management Protocol (SNMP) Agents This chapter describes the Magnum 3000 SNMP agent products. 5.1 SNMP Agents Description There are two configuration opti ons (versions) of the Magnum SNMP hardware agent. Both versions fol ...

  • GarrettCom Magnum 3000 - page 40

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 33 www Garre t t C om c om .. extensions data are in this firmware. The firm ware in the EPROMs performs the data collection and execution functions, and operates as the local controller and interface to the network manager. 5.1.2 Separate Agent Box, Model 3000-AGT The Magnum 3000 SNMP ...

  • GarrettCom Magnum 3000 - page 41

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 34 www Garre t t C om c om .. Both the Magnum 3000-MB and 3000-AGT SNMP Agents are in compliance with MIB1, MIB2, and the RFC 1368 Standard Repeater MIB, and fully support all Repeater MIB functionality as defined by IEEE 802.3 specifications. In addition to the basic Standard Repeater ...

  • GarrettCom Magnum 3000 - page 42

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 35 www Garre t t C om c om .. Table 5.1.3: Magnum SNMP Agent Commands Variable Type Repeater ID ATTRIBUTE GET Repeater Group Capacity ATTRIBUTE GET Group Map ATTRIBUTE GET Repeater Health State ATTRIBU TE GET Repeater Health Te xt ATTRIBUTE GET Repeater Health Data ATTRIBUTE GET Transmi ...

  • GarrettCom Magnum 3000 - page 43

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 36 www Garre t t C om c om .. 5.2 Installation, General Information The Magnum SNMP agent is an option with the Magnum 3000 Stackable Hubs and Concentrators. The SNMP embedded agent, Model 3000-MB, will be configured and tested as part of a Magnum 3000 stack or single unit at the factor ...

  • GarrettCom Magnum 3000 - page 44

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 37 www Garre t t C om c om .. Step 1. Re move Chassis Cover of the hub The chassis cover is made in one piece, forming the top and the front of the unit. There are 7 screws located on top and 3 on the front of the unit as shown below. Remove these screws. O nce these are removed, the ch ...

  • GarrettCom Magnum 3000 - page 45

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 38 www Garre t t C om c om .. plugs into the main board and into the power supply with other assorted cables. The exact type and number of cables and connect ors for this installation varies depending upon the vintage of the hub unit being upgraded. Kits may sometimes be available from ...

  • GarrettCom Magnum 3000 - page 46

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 39 www Garre t t C om c om .. Table 5.3: Eight-Positi on DIP Switch Configur ation Table address s w i t c h 12345 6 1 on 2 on 3 on on 4 on 5 on on 6 on on 7 on on on 8 on 9 on on 10 on on 11 on on on 12 on on 13 on on on 14 on on on 15 on on on on 16 on 17 on on 18 on on 19 on on on ...

  • GarrettCom Magnum 3000 - page 47

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 40 www Garre t t C om c om .. operations: CPU test, EPROM CRC test, DRAM test, Network Interface Controller test and NVRAM test . During the configuration process, an ANSI com patible terminal or a PC running ANSI terminal emulation software should be connected (through a null modem cab ...

  • GarrettCom Magnum 3000 - page 48

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 41 www Garre t t C om c om .. From the top menu prompt > , type: C {Cr} . On the terminal, the prompt will appear: CFG> The agent configuration menu cons ists of the following commands: ADDRESS BOOTP COMMUNITY DISPLAY GATEWAY MANAGER NAMESERVER SUBNETMASK EXIT To see a command sel ...

  • GarrettCom Magnum 3000 - page 49

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 42 www Garre t t C om c om .. 3. COMMUNITY C[OMMUNITY] [# [NAME [S] [MANAGER....]]] Used to set the community string for GET and SET operations. # -- number of community. (Up to 10 different communities m ay be set) S -- allow SET operations. (If you do not "S" th is command, ...

  • GarrettCom Magnum 3000 - page 50

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 43 www Garre t t C om c om .. After new subnet configuration informati on is set in operation, it will reside in NVRAM. Powering down the Magnum 3000 will not destroy it, and at power up the agent will read the configuration information from NVRA M and start operations with it. 5.4.3 Ot ...

  • GarrettCom Magnum 3000 - page 51

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 44 www Garre t t C om c om .. 6.0 TROUBLESHOOTING All Magnum Ethernet products are designed to provide reliability and consistently high performance in all network environments. The installation of Magnum 3000 Stackable Hubs is a straightforward procedure (see INSTALLATION, Section 2.6) ...

  • GarrettCom Magnum 3000 - page 52

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 45 www Garre t t C om c om .. 6.2 When Calling for Assistance Please be prepared to provide the following information. 1. A complete description of the problem, including the following points: a. The nature and duration of the problem; b. Situations when the problem occurs; c. The compo ...

  • GarrettCom Magnum 3000 - page 53

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 46 www Garre t t C om c om .. GarrettCom reserves the right to ch arge for the testing of non-defective units under warranty. Testing and repair of product that is not under warranty will result in a customer (user) charge. 6.4 Shipping and Packaging Information Should you need to ship ...

  • GarrettCom Magnum 3000 - page 54

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 47 www Garre t t C om c om .. APPENDIX B : Internal DC Power Supply Option B1.0 SPECIFICATIONS - FOR MAGNUM 3000S Power Supply (Inte rnal -48VDC Option) DC Power Connector: 3 terminals: “ - “, “GND”, “+” Input Voltage: 36 - 70 VDC Power Consumption: Model 3024 NEBS : 18 watt ...

  • GarrettCom Magnum 3000 - page 55

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 48 www Garre t t C om c om .. The –48VDC solution is particularly us eful in the telecommunication industry, where it is common for facilities to operate on -48VDC power. Such companies include regular and wireless telephone service provide rs, Internet Service Providers (ISPs) and ot ...

  • GarrettCom Magnum 3000 - page 56

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 49 www Garre t t C om c om .. B4.1 UL Requirements 1. Minimum 14 AWG cable for connecti on to a Centralized DC power source. 2. Fastening torque of the lugs on the terminal block: 9 inch pound max. 3. Centralized DC Power Source cable secureme nt, use at least four cable ties to secure ...

  • GarrettCom Magnum 3000 - page 57

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 50 www Garre t t C om c om .. GND: Terminal for “earth” or ground wire connection to the hub chassis Input: Two separate sources, each at 120 - 160 VDC Power Consumption: Model 3024 NEBS : 18 watt typical, 30 watts max. Power Consumption: Model 3012 NEBS : 10 watt typical, 20 watts ...

  • GarrettCom Magnum 3000 - page 58

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 51 www Garre t t C om c om .. C5.0 INSTALLATION This section describes the proper connection of the -48VDC, 24VDC & 125VDC dual source leads to the –48 VDC, 24 VDC and 125VDC power terminal block on the Magnum 3000s (shown in Figure C5.0 ) The -48VDC terminal block on the Ma gnum ...

  • GarrettCom Magnum 3000 - page 59

    Magnum 3000 Stackable Hubs Installation and User Guide (07/06) 52 www Garre t t C om c om .. C6.0 ORDERING INFORMATION To order the optional Dual-Source -48VDC power supply factory installed, order “Dual-Src48V” as a separate line item following the product model. Example: Magnum 3012-48VDC Dual-Src-48V for the regular dual-source model or Dual ...

Produzent GarrettCom Kategorie Switch

Dokumente, die wir vom Produzenten des Geräts GarrettCom Magnum 3000 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen GarrettCom
- Bedienungsanleitungen Magnum 3000
- Produktkarten GarrettCom
- Informationsbroschüren
- oder Energieetiketten GarrettCom Magnum 3000
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung GarrettCom Magnum 3000.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen GarrettCom Magnum 3000, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen GarrettCom Magnum 3000. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts GarrettCom Magnum 3000 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts GarrettCom Magnum 3000, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von GarrettCom Magnum 3000 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von GarrettCom Magnum 3000 verständlich ist.

Eine gänzliche Bedienungsanleitung von GarrettCom sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von GarrettCom Magnum 3000 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von GarrettCom Magnum 3000 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich GarrettCom Magnum 3000, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts GarrettCom Magnum 3000 - die uns die ersten Schritte während der Nutzung von GarrettCom Magnum 3000 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit GarrettCom Magnum 3000 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von GarrettCom Magnum 3000 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich GarrettCom Magnum 3000?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit GarrettCom Magnum 3000 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit GarrettCom Magnum 3000 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen