    INTELLIGENT LABEL SENSORS OPERA TIONS MANU AL CS2000 & CS2000-QD C S 2 0 0 0 & C S 2 0 0 0 - Q D CS2000 & CS2000-QD CONTROL TECHNOLOGIES 2617 Fremontia Drive San Bernardino, CA 92404 Phone: 877-880-5389 F ax: 877-880-5537 www .con-tech.com ...

  • Contec CS2000 - page 2

    Table of Contents General Information  Features  Diagram  CS2000 Quick Start  CS2000-QD Quick Start Installation  Mounting  CS2000 Wiring  CS2000-QD Wiring Operation  Label Placement  Push-Button Functions  LED Functions  Operation Features   Output Mode   Light/Dark Operation   Contrast Setting ? ...

  • Contec CS2000 - page 3

    - 1 - General Information Features: • 10 to 30 VDC input - reverse polarity protected • Fast RISC microprocessor controlled • Easy one touch setup - label sensitivity easily adjusted, to the optimal setting, by  the push of a button • Missing label compensation - outputs a stop pulse even when a label is missing • Level ...

  • Contec CS2000 - page 4

    - 2 - General Information Yellow LED: Indicates label backing (web) Push-button Red LED: Indicates output state Green LED: Indicates label + label backing Optional 6" Quick Disconnect 4 Pin Male Cable/Connector #8-32 Mounting Holes EASY SETUP WEB OUT LABEL 1. 2. 3. 4. Po si ti on we b und er sen sin g area and hold bu tt on do wn unt il y el l ...

  • Contec CS2000 - page 5

    - 3 - General Information CS2000 Quick Start: 1.  Connect red wire to supply voltage 2.  Connect black wire to supply common 3.  For NPN Output - connect orange wire to black wire  For PNP Output - connect orange wire to red wire 4.  Connect white wire to your controller - refer to page 6 for wiring diagrams 5.  Turn on power 6. ? ...

  • Contec CS2000 - page 6

    - 4 - General Information CS2000-QD Quick Start: 1.  Plug the CS2000-QD's male connector into a suitable 4 pin female connector 2.  Connect brown wire to supply voltage 3.  Connect blue wire to supply common 4.  For NPN Output - connect black wire to blue wire  For PNP Output - connect black wire to brown wire 5.  Connect whi ...

  • Contec CS2000 - page 7

    - 5 - Installation Mounting: The CS2000 comes with 8 mounting holes allowing for many different mounting options. The holes are tapped for #8-32 screws and are 0.31" deep. We suggest using #8-32 x 3/8" stainless steel screws. Some different options are shown below. * To avoid electro-static discharge and sensor malfunction, the CS2000 sho ...

  • Contec CS2000 - page 8

    - 6 - Installation CS2000 Wiring: The CS2000 comes with an 8' - 4 conductor cable. Refer below for wire designations. RED = 10-30 VDC BLK = Common WHT = Output ORN = NPN / PNP Output Selector Optoisolat or CS2000 RED 10-30V LOAD BLK WHT ORN WHT ORN WHT ORN WHT ORN WHT +5V 5V Logic 1K 1/4W Supply Voltage 12V = 1K 1/4W 24V = 2K 1/4W 12V = 1K 1/4 ...

  • Contec CS2000 - page 9

    - 7 - Installation CS2000-QD Wiring: The CS2000-QD comes with a 6" quick disconnect M12 - 4 pin male cable/connector (Turck P/N RS4.4T-2). Refer below for wire designations. Pin 1. BRN = 10-30 VDC Pin 2. WHT = Output Pin 3. BLU = Common Pin 4. BLK = NPN / PNP Output Selector Optoisolat or CS2000-QD BRN 10-30V LOAD BLU WHT BLK WHT BLK WHT BLK W ...

  • Contec CS2000 - page 10

    ACME LABELS ACME LABELS AC ACME LABELS ACME LABELS ACME LABELS ACME LABELS - 8 - Operation Label Placement: For best results, position straight edge of label under the sensing area. Try to avoid sensing on rounded corners or other curved areas. Refer to diagram below. Less than 1 second 1 to less than 5 seconds 5 to less than 10 seconds 30+ seconds ...

  • Contec CS2000 - page 11

    - 9 - Operation LED Functions:  Yellow - comes on when label backing (web) is under the sensing area  Red - comes on when output is active - NPN sinking or PNP sourcing  Green - comes on when label over label backing is under the sensing area Operation Features:  The CS2000 has 3 different operation features that can be changed to accom ...

  • Contec CS2000 - page 12

    - 10 - Adjusting Label Sensitivity Overview:  The CS2000 will automatically adjust its label sensitivity, to the optimal setting, by simply depressing a push-button. This adjustment process is referred to as "Easy Setup." It is recommended that the operator adjust the label sensitivity for each new roll of labels due to differences in ...

  • Contec CS2000 - page 13

    - 11 - Missing Label Compensation Overview:  The CS2000 has the capability to detect a single missing label and output a stop pulse as though the label were present. In order for Missing Label Compensation to function properly the operator must first: a) have Pulse Output selected - see Program Mode (page 12) for more information. b) adjust the ...

  • Contec CS2000 - page 14

    - 12 - Program Mode Entering Program Mode:  Program Mode is used to change any or all of the Operation Features. To enter Program Mode depress the push-button until the yellow and green LED's begin toggling (30 sec.), then release. The LED's will then output the current set-up configuration (and every 3 sec. thereafter). For example: a ...

  • Contec CS2000 - page 15

    - 13 - Specifications General: Power Supply..................................................... 10-30 VDC, reverse polarity protected Power Consumption............................................ 50mA max. Output.............................................................. NPN / PNP open collector Output Current.......................... ...

  • Contec CS2000 - page 16

    - 14 - Specifications Dimensions: CS2000 0.44 11.2 0.625 1.00 25.4 0.625 15.9 79.4 3.125 50.8 15 0.59 2.00 0.22 5.6 0.75 19.1 0.50 12.7 15.9 0.09 Sensing Area 15.9 0.625 76.2 3.00 EASY SETUP WEB OUT LABEL 13.5 0.53 1.00 88.9 3.50 25.4 9.5 0.38 2.4 1. 2. 3. 4. Po si t io n we b und er se nsi ng area and hold bu tt on do wn un ti l y e l lo w L E D c ...

  • Contec CS2000 - page 17

    - 15 - Cleaning Instructions Cleaning Instructions: 1.  Begin by removing the sensor lid's 4 screws with a 1/16" L wrench. 2.  Gently lift the sensor's circuit board out by grasping the switch and pulling upward. Do not  remove the insulation tape. 3.  Clean the lens of the sensor's photo eye with a clean soft cloth ...

  • Contec CS2000 - page 18

    - 16 - Warranty Terms & Conditions Warranty:  The CS2000 Label Sensor is warranteed for a period of two (2) years from the time of purchase. Control Technologies guarantees the CS2000 to be free from defects in materials or workmanship, and that, if used correctly will perform within specifications. The warranty covers normal wear and tear, ...

Produzent Contec Kategorie Stud Sensor

Dokumente, die wir vom Produzenten des Geräts Contec CS2000 erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Contec
- Bedienungsanleitungen CS2000
- Produktkarten Contec
- Informationsbroschüren
- oder Energieetiketten Contec CS2000
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Contec CS2000.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Contec CS2000, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Contec CS2000. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Contec CS2000 ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Contec CS2000, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Contec CS2000 hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Contec CS2000 verständlich ist.

Eine gänzliche Bedienungsanleitung von Contec sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Contec CS2000 bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Contec CS2000 befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Contec CS2000, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Contec CS2000 - die uns die ersten Schritte während der Nutzung von Contec CS2000 erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Contec CS2000 hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Contec CS2000 im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Contec CS2000?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Contec CS2000 nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Contec CS2000 hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)