  • Health O Meter 2000KL - page 1

    PRO PLUS ® STRETCHER SCALE MODEL 2000KL OPERATION MANUAL AA0339-0 ...

  • Health O Meter 2000KL - page 2

    1 PRO PLUS ® STRETCHER SCALE MODEL 2000KL Thank you for your purchase of this product. Please read this manual carefully and keep it handy for ready reference. TABLE OF CONTENTS CAUTION AND WARNING .................................................................................................... 2 SPECIFICATIONS ................................. ...

  • Health O Meter 2000KL - page 3

    2 CAUTION AND WARNING To prevent injury and damage to your scale, pleas e follow these instructions very carefully. • To ensure proper operation of the ProPlus® Stretcher Scale, this operation manual should be reviewed carefully before operation. Keep this manual available for future reference, and also for use in the orientation of new personne ...

  • Health O Meter 2000KL - page 4

    3 SPECIFICATIONS GENERAL Health o meter’s ProPlus ® Stretcher Scale Model 2000KL uses highly sophisticated microprocessor technology. This scale is designed to provide accurate, reliable and repeatable weight measurements and features that make the weighing process simple, fast and convenient. The scale is set up to use motion-sensing weighing t ...

  • Health O Meter 2000KL - page 5

    4 ASSEMBLY INSTRUCTIONS Before Assembly The Model 2000KL ProPlus® Stretcher Scale is shipped disassembled in two (2) separate cartons. Carefully inspect all cartons for shipping damage before unpacking. If damage is found, contact your shipper or Healthometer Professional immediately. Claims must be filed with the shipper as soon as possible after ...

  • Health O Meter 2000KL - page 6

    5 ASSEMBLY INSTRUCTIONS Assembling the Patient Lifter 1. Place the Stretcher Storage Tray on the Lifter Base, as shown below, before attaching the Lifter Mast. Figure 2 2. Remove black plastic protective caps from Lifter Mast. Insert the bottom of the Lifter Mast and Hydraulic Pump assembly into the mast sleeve (through the Stretcher Tray Holder) o ...

  • Health O Meter 2000KL - page 7

    6 ASSEMBLY INSTRUCTIONS Attaching the Display and Scale to the Patient Lifter Figure 2 Figure 3 PHILLIPS PAN HEAD SCREW NC8-32x5/16 ...

  • Health O Meter 2000KL - page 8

    7 ASSEMBLY INSTRUCTIONS 4. Connect the Lifter Boom and the Display Support to the Lifter Mast using the NC ⅜ - 20x2 ½” hex screw and tighten the self lock nut on its other side. Note : This screw is the axis of the Lifter Boom, so it is imperative that the three parts – Lifter Boom, Lifter Mast and Display Support – be assembled in the pro ...

  • Health O Meter 2000KL - page 9

    8 ASSEMBLY INSTRUCTIONS Figure 4 10. Position the Display Assembly close to the Display Support. Connect the load cell cable connector to the load cell port on the rear of the Display Assembly and insert and secure the cable into the center channel in the display. Note : Do not attach the power cord at this point. 11. Slide the display assembly ont ...

  • Health O Meter 2000KL - page 10

    9 ASSEMBLY INSTRUCTIONS Figure 5 15. Hang the Load Cell Assembly on the two hooks at the end of the Lifter Boom, using the loops on top of the Load Cell Assembly. 16. Connect the end of the Load Cell Cable coming out of the center of the Load Cell Assembly to its port in the Lifter Boom. 17 Use the two washers and shoulder screws to connect the two ...

  • Health O Meter 2000KL - page 11

    10 SET UP Preparing the Scale for Use 1. Remove protective plastic film from keypad and display. 2. Place batteries in the battery holder (see “Replacing Batteries”). 3. Plug the scale’s AC adapter into the power source. 4. Press the ON/OFF button to turn the scale on. The display will show “Health o Meter Pro-Plus” and then ”000 Lb 00 ...

  • Health O Meter 2000KL - page 12

    11 OPERATION INSTRUCTIONS Preweighing the Stretcher 1. Make sure the scale is free of load (nothing is hanging from it), including the stretcher. 2. Press the ON/OFF button to turn the scale on. 3. Wait until ”000 Lb 00 oz ” and “ZERO” on the left side of the display will appear. The scale will remember the last amount that was tared, so if ...

  • Health O Meter 2000KL - page 13

    12 OPERATION INSTRUCTIONS 4. Release the hanging loops from the lifter. Note : The scale is programmed to save the last setting chosen as well as the weight of the stretcher as tare weight. This enables weighing a number of patients without having to re- set the scale. If a weight was added or reduced from the stretcher scale it is required to rese ...

  • Health O Meter 2000KL - page 14

    13 OPERATION INSTRUCTIONS Figure 7. Keypad ITEM DESCRIPTION FUNCTION POWER Turns scale ON and OFF. ZERO Zeros the scale prior to weighing. HOLD/RELEASE Holds the value of the weighed object on the display until the button is pressed again to clear the value. Also used to scroll down in the menu. REWEIGH Allows repeated weighing of the patient witho ...

  • Health O Meter 2000KL - page 15

    14 OPERATION INSTRUCTIONS MENU In the menu screen the user can set preferences and/or instruct the scale how to handle stored data. The menu can be navigated using the up and down keys ( cd ) or by entering the associated menu position number with the keypad. The menu has a “roll-over” way of working: when the user scrolls to the bottom of the ...

  • Health O Meter 2000KL - page 16

    15 OPERATION INSTRUCTIONS 02 TARE WEIGHT NOTE : Due to the scale’s sensitivity, we recommend using the REWEIGH function prior to setting the TARE weight, in order to eliminate any operator interference with the item to be tared out. There are two ways to manually enter a tare weight (such as the weight of a stretcher , shoes, etc): press MENU (1) ...

  • Health O Meter 2000KL - page 17

    16 OPERATION INSTRUCTIONS 3. The scale will prompt you to enter the patient’s height. Use the keypad to enter the height in 1/4" (1=1/4, 2=1/2, 3=3/4) or 1 cm increments (use inches for weight in lb, cm for kg). Press ENTER. 4. Display will read the patient’s BMI. The scale offers you two options to manage your in formation: to transfer/do ...

  • Health O Meter 2000KL - page 18

    17 OPERATION INSTRUCTIONS 04 Transfer now All the values stored in memory are transferred to the PC and the scale memory is cleared of all values. If the transfer was unsuccessful, the values are kept in memory until successfully transferred or cleared. 05 Clear memory All the values stored in memory will be cleared. 04 SCALE SETTINGS 01 Auto Hold ...

  • Health O Meter 2000KL - page 19

    18 OPERATION INSTRUCTIONS 03 Auto Off Time The user can determine how long the scale will operate before turning off automatically due to inactivity. Default time is 10 minutes. If the value is set to zero, the auto off function is disabled. 04 Tone Volume There is an option to adjust the beeping tone of the scale. This tone should sound when the s ...

  • Health O Meter 2000KL - page 20

    19 OPERATION INSTRUCTIONS 06 Display Backlight The user can set the brightness of the backlight. 07 Display Contrast The user can set the brightness of the LCD. 08 Live Weight By selecting “Yes” the user can set the Live Weight mode to deactivate the motion-sensing mode. In the Live Weight mode the weight displayed will fluctuate with the patie ...

  • Health O Meter 2000KL - page 21

    20 OPERATION INSTRUCTIONS Set the date using the up and down keys cd and enter the values on the keypad. 02 About This screen displays the software version of the scale. 06 SYSTEM TEST 01 Battery Test The scale will display the estimated amount of battery life remaining until the batteries will have to be replaced. NOTE : In order to complete the b ...

  • Health O Meter 2000KL - page 22

    21 OPERATION INSTRUCTIONS 03 UI Test The scale has a diagnostic routine where it tests the User Interface (UI) hardware functionality (LCD, keypad). In order to do this the user has to press all the keys according to the messages displayed on the screen. If the requested command was not received or wrong button was pressed, the following message wi ...

  • Health O Meter 2000KL - page 23

    22 OPERATION INSTRUCTIONS 02 Disp Height & ID When the user selects to display the height and ID of the user, it will be displayed at the bottom of the screen. We recommend the use of this function to ensure that the patient’s correct ID and height have been entered. 03 Prompt For Height When this option is activated, the user will be asked t ...

  • Health O Meter 2000KL - page 24

    23 MAINTENANCE GENERAL This section provides instructions for maintenance, cleaning, troubleshooting and operator replaceable parts for the ProPlus ® Stretcher Scale Model 2000KL. Maintenance operations other than those described in this section should be performed by qualified service personnel. MAINTENANCE Before first use and after periods of n ...

  • Health O Meter 2000KL - page 25

    24 TROUBLESHOOTING Refer to the following instructions to check and correct any failure before contacting service personnel. SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Scale does not turn on 1. Dead Battery 2. Faulty electrical outlet 3. Bad power supply 1. Replace batteries 2. Use a different outlet 3. Replace adapter Questionable weight or the scal ...

  • Health O Meter 2000KL - page 26

    25 CALIBRATION PATH The calibration is performed in Kg or Lb, according to the units of measure used upon entering into the calibration path. Operator Action Display 1. Press ON/OFF button and immediately press and hold HOLD/RELEASE button for 3-4 seconds Calibration Process 2. Press ENTER Enter load weight 400.0 3. Using cd keys and/or the keypad, ...

  • Health O Meter 2000KL - page 27

    26 EXPLODED VIEW OF SCALE (continue) ...

  • Health O Meter 2000KL - page 28

    27 PARTS LIST Key No. Part No . Description Qty. 1 1109403-0 DISPLAY ASSEMBLY 1 2 2268101-0 TILT MECH. ASSEMBLY 1 3 3848401-0 PLASTIC WASHER 2 4 401369 PLASTIC OVAL BAR COVER 3 5 HEX. HEAD SCREW NC 3/8-16*2 1/2 1 6 HEX. HEAD SCREW NC 3/8-16*1 3/4 1 7 2268001-0 LIFTER BOOM ASSEMBLY 1 8 2034701-0 MAIN BOARD TO CON. DIG CABLE 1 9 3809801-0 BEAM ASSEMB ...

  • Health O Meter 2000KL - page 29

    28 WARRANTY LIMITED WARRANTY What does the Warranty Cover? Pelstar LLC scales are warranted from date of purchase against defects of materials or in workmanship for a period of three (3) years. If product fails to function properly, return the product, freight prepaid and properly packed to Pelstar. See “To Get Warranty Service” below for instr ...

Produzent Health O Meter Kategorie Scale

Dokumente, die wir vom Produzenten des Geräts Health O Meter 2000KL erhalten, können wir in mehrere Gruppen teilen. Unteranderem in:
- technische Zeichnungen Health O Meter
- Bedienungsanleitungen 2000KL
- Produktkarten Health O Meter
- Informationsbroschüren
- oder Energieetiketten Health O Meter 2000KL
Jede von ihnen ist wichtig, jedoch finden wir die wichtigsten Informationen für den Nutzer des Geräts in der Bedienungsanleitung Health O Meter 2000KL.

Die Dokumentengruppe, die als Bedienungsanleitungen bezeichnet wird, wird ebenfalls in detaillierte Arten geteilt, solche wie: Montageanleitungen Health O Meter 2000KL, Wartungsanleitungen, Kurzanleitungen oder Benutzeranleitungen Health O Meter 2000KL. Abhängig vom Bedarf, sollten Sie das Dokument finden, das Sie brauchen. In unserem Service können Sie sich die populärste Bedienungsanleitung des Produkts Health O Meter 2000KL ansehen.

Ähnliche Bedienungsanleitungen

Die komplette Bedienungsanleitung des Geräts Health O Meter 2000KL, wie sollte sie aussehen?
Die Bedienungsanleitung, auch bezeichnet als Benutzerhandbuch, oder einfach nur „Anleitung”, ist ein technisches Dokument, das dem Benutzer bei der Nutzung von Health O Meter 2000KL hilfreich sein soll. Die Bedienungsanleitungen werden in der Regel von technischen Schriftstellern geschrieben, aber in einer Sprache, die für alle Nutzer von Health O Meter 2000KL verständlich ist.

Eine gänzliche Bedienungsanleitung von Health O Meter sollte einige Grundelemente enthalten. Ein Teil von ihnen ist nicht so wichtig, wie z.B.: die Titelseite oder Autorenseiten. Die restlichen von ihnen jedoch, sollten Informationen liefern, die für den Nutzer von enormer Wichtigkeit sind.

1. Einführung und Hinweise, wie man sich in einer Bedienungsanleitung von Health O Meter 2000KL bewegt - Am Anfang jeder Bedienungsanleitung sollten wir Hinweise bezüglich der Nutzungsart eines bestimmten Ratgebers finden. In ihr sollten sich Informationen über die Lokalisierung des Inhaltsverzeichnisses von Health O Meter 2000KL befinden, FAQ oder über oft auftretende Probleme – also Stellen, die von den Benutzern in jeder Bedienungsanleitung am meisten gesucht werden
2. Inhaltsverzeichnis - Index aller Ratschläge bezüglich Health O Meter 2000KL, die wir im aktuellen Dokument finden
3. Ratschläge zur Nutzung der Grundfunktionen des Geräts Health O Meter 2000KL - die uns die ersten Schritte während der Nutzung von Health O Meter 2000KL erleichtern sollten
4. Troubleshooting - geordneter Tätigkeitslauf, der uns bei der Diagnose und als nächstes bei der Lösung wichtiger Probleme mit Health O Meter 2000KL hilft
5. FAQ - häufig gestellte Fragen
6. Kontaktdaten Informationen darüber, wo man Kontakt zum Produzenten / Service von Health O Meter 2000KL im bestimmten Land suchen kann, wenn es nicht gelingt, das Problem selbst zu lösen.

Haben Sie eine Frage bezüglich Health O Meter 2000KL?

Nutzen Sie das untere Formular

Wenn Sie mit Hilfe der gefundenen Bedienungsanleitung Ihr Problem mit Health O Meter 2000KL nicht gelöst haben, stellen Sie eine Frage, indem Sie das untere Formular nutzen. Wenn einer der Nutzer ein ähnliches Problem mit Health O Meter 2000KL hatte, ist es möglich, dass er mit Ihnen die Lösung teilen möchte.

Text vom Bild übertragen

Kommentare (0)